acsPowerMgmtUPSOutputTablePowerFactorL2
ACS8000-MIB ·
.1.3.6.1.4.1.10418.26.2.5.16.1.31
Object
column
SNMPv2-TCDisplayString
The system output power factor on line 2.
Context
- MIB
- ACS8000-MIB
- OID
.1.3.6.1.4.1.10418.26.2.5.16.1.31- Type
- column
- Access
- readonly
- Status
- current
- Parent
- acsPowerMgmtUPSOutputTableEntry
- Table
- acsPowerMgmtUPSOutputTable
- Siblings
- 30
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| acsPowerMgmtUPSOutputTablePortNumber Serial Port number. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.10418.26.2.5.16.1.1 |
| acsPowerMgmtUPSOutputTableRMSCurrentL2 System output RMS current for line L2. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.10 |
| acsPowerMgmtUPSOutputTableRMSVoltageL1N The system output RMS voltage. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.11 |
| acsPowerMgmtUPSOutputTableRMSVoltageL2N The system output RMS voltage. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.12 |
| acsPowerMgmtUPSOutputTableRMSVoltageL1L2 The system output RMS voltage. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.13 |
| acsPowerMgmtUPSOutputOffDelay Turns the UPS output off after the number of seconds specified.
When a value is written to this object the output will be turned
off after the specified time has elapsed and the o… | column | Integer32 | .1.3.6.1.4.1.10418.26.2.5.16.1.14 |
| acsPowerMgmtUPSOutputOnDelay Turns the UPS output on after the number of seconds specified.
When a value is written to this object the output will be turned
on after the specified time has elapsed. | column | Integer32 | .1.3.6.1.4.1.10418.26.2.5.16.1.15 |
| acsPowerMgmtUPSOutputCycleDelay Turns the UPS off and then back on after the number of seconds specified.
When a value is written to this object the output will turned off immediately
and then turned back on aft… | column | Integer32 | .1.3.6.1.4.1.10418.26.2.5.16.1.16 |
| acsPowerMgmtUPSOutputTableMaxVoltageL1 The maximum system output voltage measurement for line 1 since the last reset. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.17 |
| acsPowerMgmtUPSOutputTableMinVoltageL1 The minimum system output voltage measurement for line 1 since the last reset. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.18 |
| acsPowerMgmtUPSOutputTableMaxVoltageL2 The maximum system output voltage measurement for line 21 since the last reset. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.19 |
| acsPowerMgmtUPSOutputTableUpsIndex Index. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.10418.26.2.5.16.1.2 |
| acsPowerMgmtUPSOutputTableMinVoltageL2 The minimum system output voltage measurement for line 2 since the last reset. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.20 |
| acsPowerMgmtUPSOutputTableNominalVoltage The nominal (or rated) system output voltage. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.21 |
| acsPowerMgmtUPSOutputTablePowerNominalFrequency The nominal (or rated) system output frequency. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.22 |
| acsPowerMgmtUPSOutputTablePowerApparentPowerRating Output apparent power rating. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.23 |
| acsPowerMgmtUPSOutputTablePowerNominalPowerFactor The nominal (or rated) system power factor. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.24 |
| acsPowerMgmtUPSOutputTablePowerPowerFactorCorrection The state of the power factor correction circuitry of the system. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.25 |
| acsPowerMgmtUPSOutputTablePowerL1 The system output power on line 1. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.26 |
| acsPowerMgmtUPSOutputTablePowerL2 The system output power on line 2. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.27 |
| acsPowerMgmtUPSOutputTableApparentPowerL1 The system output apparent power on line 1. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.28 |
| acsPowerMgmtUPSOutputTableApparentPowerL2 The system output apparent power on line 2. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.29 |
| acsPowerMgmtUPSOutputTableApparentPower DC Bus Voltage | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.3 |
| acsPowerMgmtUPSOutputTablePowerFactorL1 The system output power factor on line 1. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.30 |
| acsPowerMgmtUPSOutputTableFrequency Output frequency. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.4 |
| acsPowerMgmtUPSOutputTablePercentPower The system output power as a percentage of the rated capacity. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.5 |
| acsPowerMgmtUPSOutputTablePercentPowerL1 The system output power on line L1 as a percentage of the rated capacity. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.6 |
| acsPowerMgmtUPSOutputTablePercentPowerL2 The system output power on line L2 as a percentage of the rated capacity. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.7 |
| acsPowerMgmtUPSOutputTablePower The sum total power of all system output phases. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.8 |
| acsPowerMgmtUPSOutputTableRMSCurrentL1 System output RMS current for line L1. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.5.16.1.9 |