acsSensors1WireTableValueAvg
ACS8000-MIB ·
.1.3.6.1.4.1.10418.26.2.7.20.1.10
Object
column
SNMPv2-SMIInteger32
Average sensor reading detected. Unit is specified in acsSensors1WireTableUnit.
Context
- MIB
- ACS8000-MIB
- OID
.1.3.6.1.4.1.10418.26.2.7.20.1.10- Type
- column
- Access
- readonly
- Status
- current
- Parent
- acsSensors1WireTableEntry
- Table
- acsSensors1WireTable
- Siblings
- 21
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| acsSensors1WireTableIndex Index of detected 1-wire sensor. | column | Integer32 | .1.3.6.1.4.1.10418.26.2.7.20.1.1 |
| acsSensors1WireTableValueLowWarning If the sensor value falls below this value, an event notification
will be generated. Unit is specified in acsSensors1WireTableUnit. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.26.2.7.20.1.11 |
| acsSensors1WireTableValueLowCritical If the sensor value falls below this value, an event notification
will be generated. Unit is specified in acsSensors1WireTableUnit. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.26.2.7.20.1.12 |
| acsSensors1WireTableValueHighWarning If the sensor value rises above this value, an event notification
will be generated. Unit is specified in acsSensors1WireTableUnit. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.26.2.7.20.1.13 |
| acsSensors1WireTableValueHighCritical If the sensor value rises above this value, an event notification
will be generated. Unit is specified in acsSensors1WireTableUnit. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.26.2.7.20.1.14 |
| acsSensors1WireTableReset A set value of update(2) will reset the 1-wire sensor min/max/avg values. | column | Enumeration | .1.3.6.1.4.1.10418.26.2.7.20.1.15 |
| acsSensors1WireTableAnalogAlarm Status of the 1-wire analog sensor alarm.
Used for temperature, humidity, and differential pressure sensors only.
For all other sensor types the value notApplicable(0) will be ret… | column | Enumeration | .1.3.6.1.4.1.10418.26.2.7.20.1.16 |
| acsSensors1WireTableContactAlarm1 Status of the 1-wire contact sensor alarm.
Used for door and dry contact sensors only.
For all other sensor types the value notApplicable(0) will be returned. | column | Enumeration | .1.3.6.1.4.1.10418.26.2.7.20.1.17 |
| acsSensors1WireTableContactAlarm2 Status of the 1-wire contact sensor alarm.
Used for door and dry contact sensors only.
For all other sensor types the value notApplicable(0) will be returned. | column | Enumeration | .1.3.6.1.4.1.10418.26.2.7.20.1.18 |
| acsSensors1WireTableContactAlarm3 Status of the 1-wire contact sensor alarm.
Used for door and dry contact sensors only.
For all other sensor types the value notApplicable(0) will be returned. | column | Enumeration | .1.3.6.1.4.1.10418.26.2.7.20.1.19 |
| acsSensors1WireTableName Name of the 1-wire sensor. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.7.20.1.2 |
| acsSensors1WireTableLeakFilterTime Leak filter time in seconds. | column | Enumeration | .1.3.6.1.4.1.10418.26.2.7.20.1.20 |
| acsSensors1WireTableLeakAlarm Status of the leak alarm for the leak sensor.
Used for leak sensors only.
For all other sensor types the value notApplicable(0) will be returned. | column | Enumeration | .1.3.6.1.4.1.10418.26.2.7.20.1.21 |
| acsSensors1WireTableLeakCableFailAlarm Status of the cable fail alarm for the leak sensor.
Used for leak sensors only.
For all other sensor types the value notApplicable(0) will be returned. | column | Enumeration | .1.3.6.1.4.1.10418.26.2.7.20.1.22 |
| acsSensors1WireTableLocation Location of the 1-wire sensor. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.7.20.1.3 |
| acsSensors1WireTableAddress Address of the 1-wire sensor. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.7.20.1.4 |
| acsSensors1WireTableType Type of 1-wire sensor. | column | Enumeration | .1.3.6.1.4.1.10418.26.2.7.20.1.5 |
| acsSensors1WireTableUnit The unit of the 1-wire sensor.
notApplicable(0) = used for contact or leak sensor
celsius(1) = used for temperature sensor
fahrenheit(2) = used for temperature sensor
per… | column | Enumeration | .1.3.6.1.4.1.10418.26.2.7.20.1.6 |
| acsSensors1WireTableValue Current sensor reading. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.26.2.7.20.1.7 |
| acsSensors1WireTableValueMax Maximum sensor reading detected. Unit is specified in acsSensors1WireTableUnit. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.26.2.7.20.1.8 |
| acsSensors1WireTableValueMin Minimum sensor reading detected. Unit is specified in acsSensors1WireTableUnit. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.26.2.7.20.1.9 |