FRNETSERV-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
6
Rows
6
Columns
88

frLportTable

table
.1.3.6.1.2.1.10.44.1.1 · 1 row entry · 12 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk frLportTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FRNETSERV-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FRNETSERV-MIB::frLportTable'
The Frame Relay Logical Port Information table is
an interface-specific addendum to the generic
ifTable of the Interface MIB.
frLportEntry row .1.3.6.1.2.1.10.44.1.1.1
An entry in the Frame Relay Logical Port
Information table.
Indexes
Column Syntax OID
The value of this object identifies the network
address numbering plan for this UNI/NNI logical
port. The network address is the object
ifPhysAddress. The value none(4) implies that
there is no ifPhysAddress. The FRS a…
Enumeration
Enumerated Values:
1other
2e164
3x121
4none
.1.3.6.1.2.1.10.44.1.1.1.1
The value of this object identifies the network
contact for this UNI/NNI logical port.
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.2.1.10.44.1.1.1.2
The value of this object identifies the frame
relay network location for this UNI/NNI logical
port.
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.2.1.10.44.1.1.1.3
The value of this object identifies the type of
network interface for this logical port.
Enumeration
Enumerated Values:
1uni
2nni
.1.3.6.1.2.1.10.44.1.1.1.4
The value of this object identifies the Q.922
Address field length and DLCI length for this
UNI/NNI logical port.
OctetsEnumeration
Enumerated Values:
1twoOctets10Bits
2threeOctets10Bits
3threeOctets16Bits
4fourOctets17Bits
5fourOctets23Bits
.1.3.6.1.2.1.10.44.1.1.1.5
The value of this object identifies the Local
In-Channel Signaling Protocol that is used for
this frame relay UNI/NNI logical port.

none(1): Interface does not use a PVC
signaling p…
Enumeration
Enumerated Values:
1none
2lmi
3ansiT1617D
4ansiT1617B
5ccittQ933A
.1.3.6.1.2.1.10.44.1.1.1.6
The value of this object is used as a pointer to
the table that contains the Local In-Channel
Signaling Protocol parameters and errors for this
UNI/NNI logical port.

This object has been deprecated to ref…
ObjectIdentifier .1.3.6.1.2.1.10.44.1.1.1.7
This object contains a hint to be used for
frPVCEndptDLCIIndex when creating entries in the
frPVCEndptTable. The SYNTAX of this object
matches the SYNTAX of the frPVCEndptDLCIIndex - an
object that is restricted to leg…
Integer32
Constraints:
range: 16-4194303
.1.3.6.1.2.1.10.44.1.1.1.8
The value of this object desired identifies the
type of network interface for this logical port.
Enumerationr/w
Enumerated Values:
1uni
2nni
.1.3.6.1.2.1.10.44.1.1.1.9
The value of this object identifies the desired
Local In-Channel Signaling Protocol that is used
for this frame relay UNI/NNI logical port. This
value must be made the active protocol as soon as
possible on the device.…
Enumerationr/w
Enumerated Values:
1none
2lmi
3ansiT1617D
4ansiT1617B
5ccittQ933A
.1.3.6.1.2.1.10.44.1.1.1.10
This object controls the transmission and
reception of fragmentation frames for this UNI or
NNI interface.

on(1) Frames are fragmented using the interface
fragmentation format
Note: The…
Enumerationr/w
Enumerated Values:
1on
2off
.1.3.6.1.2.1.10.44.1.1.1.11
The value of this object is the size in octets of
the maximum size of each fragment to be sent when
fragmenting. This object is only used by the
fragmentation transmitter, and the two sides of
the interface may differ.…
OctetsInteger32r/w
Constraints:
range: 0-4096
.1.3.6.1.2.1.10.44.1.1.1.12
.1.3.6.1.2.1.10.44.1.2 · 1 row entry · 25 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk frMgtVCSigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FRNETSERV-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FRNETSERV-MIB::frMgtVCSigTable'
The Frame Relay Management VC Signaling
Parameters and Errors table.
frMgtVCSigEntry row .1.3.6.1.2.1.10.44.1.2.1
An entry in the Frame Relay Management VC
Signaling Parameters Errors table.
Indexes
Column Syntax OID
The value of this object identifies the local
in-channel signaling procedural role that is used
for this UNI/NNI logical port. Bidirectional
procedures implies that both user-side and
network-side procedural roles are …
Enumeration
Enumerated Values:
1u2nnet
2bidirect
3u2nuser
.1.3.6.1.2.1.10.44.1.2.1.1
The value of this object identifies the User-side
N391 full status polling cycle value for this
UNI/NNI logical port. If the logical port is not
performing user-side (bidirectional) procedures,
then this object is not …
PollsInteger32
Constraints:
range: 1-255
.1.3.6.1.2.1.10.44.1.2.1.2
The value of this object identifies the User-side
N392 error threshold value for this UNI/NNI
logical port. If the logical port is not
performing user-side (bidirectional) procedures,
then this object is not instantiat…
EventsInteger32
Constraints:
range: 1-10
.1.3.6.1.2.1.10.44.1.2.1.3
The value of this object identifies the User-side
N393 monitored events count value for this UNI/NNI
logical port. If the logical port is not
performing user-side (bidirectional) procedures,
then this object is not ins…
EventsInteger32
Constraints:
range: 1-10
.1.3.6.1.2.1.10.44.1.2.1.4
The value of this object identifies the User-side
T391 link integrity verification polling timer
value for this UNI/NNI logical port. If the
logical port is not performing user-side
procedures, then this object is not …
SecondsInteger32
Constraints:
range: 5-30
.1.3.6.1.2.1.10.44.1.2.1.5
The value of this object identifies the Network-
side N392 error threshold value (nN2 for LMI) for
this UNI/NNI logical port. If the logical port is
not performing network-side procedures, then this
object is not insta…
EventsInteger32
Constraints:
range: 1-10
.1.3.6.1.2.1.10.44.1.2.1.6
The value of this object identifies the Network-
side N393 monitored events count value (nN3 for
LMI) for this UNI/NNI logical port. If the
logical port is not performing network-side
procedures, then this object is no…
EventsInteger32
Constraints:
range: 1-10
.1.3.6.1.2.1.10.44.1.2.1.7
The value of this object identifies the Network-
side T392 polling verification timer value (nT2
for LMI) for this UNI/NNI logical port. If the
logical port is not performing network-side
procedures, then this object …
SecondsInteger32
Constraints:
range: 5-30
.1.3.6.1.2.1.10.44.1.2.1.8
The value of this object identifies the Network-
side nN4 maximum status enquires received value
for this UNI/NNI logical port. If the logical
port is not performing network-side procedures or
is not performing LMI pro…
EventsInteger32
Constraints:
range: 5-5
.1.3.6.1.2.1.10.44.1.2.1.9
The value of this object identifies the Network-
side nT3 timer (for nN4 status enquires received)
value for this UNI/NNI logical port. If the
logical port is not performing network-side
procedures or is not performing…
SecondsInteger32
Constraints:
range: 10-10
range: 5-5
range: 15-15
range: 20-20
range: 25-25
range: 30-30
.1.3.6.1.2.1.10.44.1.2.1.10
The number of user-side local in-channel
signaling link reliability errors (i.e., non-
receipt of Status/Status Enquiry messages or
invalid sequence numbers in a Link Integrity
Verification Information Element) for this…
ErrorsSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.2.1.11
The number of user-side local in-channel
signaling protocol errors (i.e., protocol
discriminator, unnumbered information, message
type, call reference, and mandatory information
element errors) for this UNI/NNI logical …
ErrorsSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.2.1.12
The number of times the user-side channel was
declared inactive (i.e., N392 errors in N393
events) for this UNI/NNI logical port. If the
logical port is not performing user-side
procedures, then this object is not insta…
EventsSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.2.1.13
The number of network-side local in-channel
signaling link reliability errors (i.e., non-
receipt of Status/Status Enquiry messages or
invalid sequence numbers in a Link Integrity
Verification Information Element) for t…
ErrorsSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.2.1.14
The number of network-side local in-channel
signaling protocol errors (i.e., protocol
discriminator, message type, call reference, and
mandatory information element errors) for this
UNI/NNI logical port.
ErrorsSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.2.1.15
The number of times the network-side channel was
declared inactive (i.e., N392 errors in N393
events) for this UNI/NNI logical port.
EventsSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.2.1.16
The value of this object identifies the local
in-channel signaling procedural role that is used
for this UNI/NNI logical port. Bidirectional
procedures implies that both user-side and
network-side procedural roles are …
Enumerationr/w
Enumerated Values:
1u2nnet
2bidirect
3u2nuser
.1.3.6.1.2.1.10.44.1.2.1.17
The value of this object identifies the desired
User-side N391 full status polling cycle value for
this UNI/NNI logical port. If the logical port is
not performing user-side (bidirectional)
procedures, then this object…
PollsInteger32r/w
Constraints:
range: 1-255
.1.3.6.1.2.1.10.44.1.2.1.18
The value of this object identifies the desired
User-side N392 error threshold value for this
UNI/NNI logical port. If the logical port is not
performing user-side (bidirectional) procedures,
then this object is not in…
EventsInteger32r/w
Constraints:
range: 1-10
.1.3.6.1.2.1.10.44.1.2.1.19
The value of this object identifies the desired
User-side N393 monitored events count value for
this UNI/NNI logical port. If the logical port is
not performing user-side (bidirectional)
procedures, then this object is…
EventsInteger32r/w
Constraints:
range: 1-10
.1.3.6.1.2.1.10.44.1.2.1.20
The value of this object identifies the desired
User-side T391 link integrity verification polling
timer value for this UNI/NNI logical port. If the
logical port is not performing user-side
procedures, then this object…
SecondsInteger32r/w
Constraints:
range: 5-30
.1.3.6.1.2.1.10.44.1.2.1.21
The value of this object identifies the desired
Network-side N392 error threshold value (nN2 for
LMI) for this UNI/NNI logical port. If the
logical port is not performing network-side
procedures, then this object is no…
EventsInteger32r/w
Constraints:
range: 1-10
.1.3.6.1.2.1.10.44.1.2.1.22
The value of this object identifies the desired
Network-side N393 monitored events count value
(nN3 for LMI) for this UNI/NNI logical port. If
the logical port is not performing network-side
procedures, then this objec…
EventsInteger32r/w
Constraints:
range: 1-10
.1.3.6.1.2.1.10.44.1.2.1.23
The value of this object identifies the desired
Network-side T392 polling verification timer value
(nT2 for LMI) for this UNI/NNI logical port. If
the logical port is not performing network-side
procedures, then this o…
SecondsInteger32r/w
Constraints:
range: 5-30
.1.3.6.1.2.1.10.44.1.2.1.24
The value of this object identifies the desired
Network-side nT3 timer (for nN4 status enquires
received) value for this UNI/NNI logical port. If
the logical port is not performing network-side
procedures or is not perf…
SecondsInteger32r/w
Constraints:
range: 5-5
range: 10-10
range: 15-15
range: 20-20
range: 25-25
range: 30-30
.1.3.6.1.2.1.10.44.1.2.1.25
.1.3.6.1.2.1.10.44.1.3 · 1 row entry · 31 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk frPVCEndptTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FRNETSERV-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FRNETSERV-MIB::frPVCEndptTable'
The Frame Relay PVC End-Point table.  This table
is used to model a PVC end-point.  This table
contains the traffic parameters and statistics for
a PVC end-point.
          
This table is used to identify the traffic
parameters for a bi-directional PVC segment end-
          
point, and it also provides statistics for a PVC
segment end-point.
          
A PVC segment end-point is identified by a UNI/NNI
logical port index value and DLCI index value.
          
If the frame relay service provider allows the
frame relay CNM subscriber to create, modify or
delete PVCs using SNMP, then this table is used to
identify and reserve the requested traffic
parameters of each PVC segment end-point.  The
Connection table is used to 'connect' the end-
points together.  Not all implementations will
support the capability of
creating/modifying/deleting PVCs using SNMP as a
feature of frame relay CNM service.
          
Uni-directional PVCs are modeled with zero valued
traffic parameters in one of the directions (In or
 Out direction) in this table.
          
To create a PVC, the following procedures shall be
followed:
          
1)  Create the entries for the PVC segment
    endpoints in the frPVCEndptTable by specifying
    the traffic parameters for the bi-directional
    PVC segment endpoints. As shown in figure 2, a
    point-to-point PVC has two endpoints, thus two
    entries in this table.  Uni-directional PVCs
    are modeled with zero valued traffic
    parameters in one direction; all the `In'
    direction parameters for one frame relay PVC
    End-point or all the `Out' direction
    parameters for the other frame relay PVC
    Endpoint.
          
    In    _____________________________  Out
   >>>>>>|                             |>>>>>>>>
   ______|    Frame Relay Network      |________
    Out  |                             |  In
   <<<<<<|_____________________________|<<<<<<<<
 Frame Relay                         Frame Relay
     PVC                                 PVC
   Endpoint                            Endpoint
          
            Figure 2, PVC Terminology
          
2)  Go to the Frame Relay Connection Group.
frPVCEndptEntry row .1.3.6.1.2.1.10.44.1.3.1
An entry in the Frame Relay PVC Endpoint table.
Column Syntax OID
The value of this object is equal to the DLCI
value for this PVC end-point.

The values are restricted to the legal range for
the size of address field supported by the logical
port (frLportAddrDLCILen).
Integer32
Constraints:
range: 16-4194303
.1.3.6.1.2.1.10.44.1.3.1.1
The value of this object is the size in octets of
the largest frame relay information field for this
PVC end-point in the ingress direction (into the
frame relay network). The value of
frPVCEndptInMaxFrameSize must be …
OctetsInteger32r/w
Constraints:
range: 1-4096
.1.3.6.1.2.1.10.44.1.3.1.2
The value of this object is equal to the
committed burst size (Bc) parameter (measured in
bits) for this PVC end-point in the ingress
direction (into the frame relay network).

Note that the max value of t…
BitsInteger32r/w
Constraints:
range: 1-2147483647
.1.3.6.1.2.1.10.44.1.3.1.3
The value of this object is equal to the excess
burst size (Be) parameter (measured in bits) for
this PVC end-point in the ingress direction (into
the frame relay network).

Note that the max value of this…
BitsInteger32r/w
Constraints:
range: 1-2147483647
.1.3.6.1.2.1.10.44.1.3.1.4
The value of this object is equal to the
committed information rate (CIR) parameter
(measured in bits per second) for this PVC end-
point in the ingress direction (into the frame
relay network).

Note that…
Bits per SecondInteger32r/w
Constraints:
range: 1-2147483647
.1.3.6.1.2.1.10.44.1.3.1.5
The value of this object is the size in octets of
the largest frame relay information field for this
PVC end-point in the egress direction (out of the
frame relay network). The value of
frPVCEndptOutMaxFrameSize must b…
OctetsInteger32r/w
Constraints:
range: 1-4096
.1.3.6.1.2.1.10.44.1.3.1.6
The value of this object is equal to the
committed burst size (Bc) parameter (measured in
bits) for this PVC end-point in the egress
direction (out of the frame relay network).

Note that the max value of …
BitsInteger32r/w
Constraints:
range: 1-2147483647
.1.3.6.1.2.1.10.44.1.3.1.7
The value of this object is equal to the excess
burst size (Be) parameter (measured in bits) for

this PVC end-point in the egress direction (out of
the frame relay network).

Note that the m…
BitsInteger32r/w
Constraints:
range: 1-2147483647
.1.3.6.1.2.1.10.44.1.3.1.8
The value of this object is equal to the
committed information rate (CIR) parameter
(measured in bits per second) for this PVC end-
point in the egress direction (out of the frame
relay network).

Note tha…
Bits per SecondInteger32r/w
Constraints:
range: 1-2147483647
.1.3.6.1.2.1.10.44.1.3.1.9
This object is used to associate PVC end-points
as being part of one PVC segment connection. This
value of this object is equal to the value of
frPVCConnectIndex, which is used as one of the
indices into the frPVCConnec…
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.2.1.10.44.1.3.1.10
This object is used to create new rows in this
table, modify existing rows, and to delete
existing rows. To create a new PVC, the entries
for the PVC segment end-points in the
frPVCEndptTable must first be created. Ne…
SNMPv2-TCRowStatusr/w
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.2.1.10.44.1.3.1.11
The value of this object identifies the PVC
status received via the local in-channel signaling

procedures for this PVC end-point. This object is
only pertinent for interfaces that perform the
bidirection…
Enumeration
Enumerated Values:
1deleted
2active
3inactive
4none
.1.3.6.1.2.1.10.44.1.3.1.12
The number of frames received by the network
(ingress) for this PVC end-point. This includes
any frames discarded by the network due to
submitting more than Bc + Be data or due to any
network congestion recovery procedu…
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.13
The number of frames sent by the network (egress)
regardless of whether they are Bc or Be frames for
this PVC end-point.
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.14
The number of frames received by the network
(ingress) with the DE bit set to (1) for this PVC
end-point.
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.15
The number of frames received by the network
(ingress) for this PVC end-point which were
treated as excess traffic. Frames which are sent
to the network with DE set to zero are treated as
excess when more than Bc bits …
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.16
The number of frames sent by the network (egress)
for this PVC end-point which were treated as
excess traffic. (The DE bit may be set to one.)
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.17
The number of frames received by the network
(ingress) that were discarded due to traffic
enforcement for this PVC end-point. Congestion
discards are not counted in this object.
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.18
The number of octets received by the network
(ingress) for this PVC end-point. This counter
should only count octets from the beginning of the
frame relay header field to the end of user data.
If the network supporting…
OctetsSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.19
The number of octets sent by the network (egress)
for this PVC end-point. This counter should only
count octets from the beginning of the frame relay
header field to the end of user data. If the
network supporting fra…
OctetsSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.20
The number of frames received by the network
(ingress) that were discarded with the DE bit set
due to traffic enforcement for this PVC end-point.
Congestion discards are not counted in this
object.
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.21
The number of frames received by the network
(ingress) that have the FECN bit set for this PVC
end-point.
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.22
The number of frames sent by the network (egress)
that have the FECN bit set for this PVC end-
point.
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.23
The number of frames received by the network
(ingress) that have the BECN bit set for this PVC
end-point.
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.24
The number of frames sent by the network (egress)
that have the BECN bit set for this PVC end-
point.
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.25
The number of frames received by the network
(ingress) that were discarded due to input buffer
congestion, rather than traffic enforcement, for
this PVC end-point.
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.26
The number of frames counted by
frPVCEndptInCongDiscards with the DE bit set to
(1).
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.27
The number of frames sent by the network (egress)
that were discarded due to output buffer
congestion for this PVC end-point.
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.28
The number of frames counted by
frPVCEndptOutCongDiscards with the DE bit set to
(1).
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.29
The number of frames sent by the network (egress)
with the DE bit set to (1) for this PVC end-
point.
FramesSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.3.1.30
This object contains the index value of the
FR/ATM cross-connect table entry used to link the
frame relay PVC with an ATM PVC.

Each row of the frPVCEndptTable that is not
cross-connected with an ATM PVC m…
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.2.1.10.44.1.3.1.31
.1.3.6.1.2.1.10.44.1.5 · 1 row entry · 13 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk frPVCConnectTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FRNETSERV-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FRNETSERV-MIB::frPVCConnectTable'
The Frame Relay PVC Connect Table is used to
model the bi-directional PVC segment flows
including:  point-to-point PVCs, point-to-
multipoint PVCs, and multipoint-to-multipoint
PVCs.
          
This table has read-create access and is used to
associate PVC end-points together as belonging to
one connection.  The frPVCConnectIndex is used to
associate all the bi-directional flows.  Not all
implementations will support the capability of
creating/modifying/deleting PVCs using SNMP as a
feature of frame relay CNM service.
          
Once the entries in the frPVCEndptTable are
created, the following step are used to associate
the PVC end-points as belonging to one PVC
connection:
          
1)  Obtain a unique frPVCConnectIndex
    using the frPVCConnectIndexValue object.
          
2)  Connect the PVC segment endpoints together
    with the applicable frPVCConnectIndex value
    obtained via  frPVCConnectIndexValue.  The
    entries in this table are created by using
    the frPVCConnectRowStatus object.
          
3)  The agent will provide the value of the
    corresponding instances of
    frPVCEndptConnectIdentifier with the
    frPVCConnectIndex value.
          
4)  Set frPVCConnectAdminStatus to `active(1)' in
          
    all rows for this PVC segment to turn the
    PVC on.
          
For example, the Frame Relay PVC Connection Group
models a bi-directional, point-to-point PVC
segment as one entry in this table.
          
Frame Relay                           Frame Relay
 Network                                 Network
 Low Port                               High Port
         __________________________________
        |                                  |
   _____| >> from low to high PVC flow  >> |_____
        | << from high to low PVC flow  << |
        |__________________________________|
          
The terms low and high are chosen to represent
numerical ordering of a PVC segment's endpoints
for representation in this table.  That is, the
endpoint with the lower value of ifIndex is termed
'low', while the opposite endpoint of the segment
is termed 'high'.  This terminology is to provide
directional information; for example the
frPVCConnectL2hOperStatus and
frPVCConnectH2lOperStatus as illustrated above.
          
If the Frame Relay Connection table is used to
model a unidirectional PVC, then one direction
(either from low to high or from high to low) has
 its Operational Status equal to down.
          
 A PVC segment is a portion of a PVC that traverses
one Frame Relay Network, and a PVC segment is
identified by its two end-points (UNI/NNI logical
port index value and DLCI index value) through one
Frame Relay Network.
frPVCConnectEntry row .1.3.6.1.2.1.10.44.1.5.1
An entry in the Frame Relay PVC Connect table.
This entry is used to model a PVC segment in two
directions.
Column Syntax OID
The value of this object is equal to the
frPVCConnectIndexValue obtained to uniquely
identify this PVC segment connection.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.2.1.10.44.1.5.1.1
The value of this object is equal to IF-MIB
ifIndex value of the UNI/NNI logical port for this
PVC segment. The term low implies that this PVC
segment end-point has the numerically lower
ifIndex value than the connecte…
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.2.1.10.44.1.5.1.2
The value of this object is equal to the DLCI
value for this end-point of the PVC segment.
Integer32
Constraints:
range: 16-4194303
.1.3.6.1.2.1.10.44.1.5.1.3
The value of this object is equal to IF-MIB
ifIndex value for the UNI/NNI logical port for
this PVC segment. The term high implies that this
PVC segment end-point has the numerically higher
ifIndex value than the conne…
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.2.1.10.44.1.5.1.4
The value of this object is equal to the egress
DLCI value for this end-point of the PVC segment.
Integer32
Constraints:
range: 16-4194303
.1.3.6.1.2.1.10.44.1.5.1.5
The value of this object identifies the desired
administrative status of this bi-directional PVC

segment. The active(1) state means the PVC
segment is currently operational; the inactive(2)
state means t…
Enumerationr/w
Enumerated Values:
1active
2inactive
3testing
.1.3.6.1.2.1.10.44.1.5.1.6
The value of this object identifies the current
operational status of the PVC segment connection
in one direction; (i.e., in the low to high
direction). This value affects the PVC status
indicated across the ingress NNI…
Enumeration
Enumerated Values:
1active
2inactive
3testing
4unknown
.1.3.6.1.2.1.10.44.1.5.1.7
The value of this object identifies the current
operational status of the PVC segment connection
in one direction; (i.e., in the high to low
direction).. This value affects the PVC status
indicated across the ingress N…
Enumeration
Enumerated Values:
1active
2inactive
3testing
4unknown
.1.3.6.1.2.1.10.44.1.5.1.8
The value of the Interface MIB's sysUpTime object
at the time this PVC segment entered its current
operational state in the low to high direction.
If the current state was entered prior to the last
re-initialization of …
SNMPv2-TCTimeStamp
Based On: SNMPv2-SMITimeTicks
Description:
The value of the sysUpTime object at which a specific
occurrence happened. The specific occurrence must be

defined in the description of any object defined using this
type.

If sysUpTime is reset t…
.1.3.6.1.2.1.10.44.1.5.1.9
The value of the Interface MIB's sysUpTime object
at the time this PVC segment entered its current
operational state in the high to low direction.
If the current state was entered prior to the last
re-initialization of …
SNMPv2-TCTimeStamp
Based On: SNMPv2-SMITimeTicks
Description:
The value of the sysUpTime object at which a specific
occurrence happened. The specific occurrence must be

defined in the description of any object defined using this
type.

If sysUpTime is reset t…
.1.3.6.1.2.1.10.44.1.5.1.10
The status of this entry in the
frPVCConnectTable. This variable is used to
create new connections for the PVC end-points and
to change existing connections of the PVC end-
points. This object must be initially set to…
SNMPv2-TCRowStatusr/w
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.2.1.10.44.1.5.1.11
This is a service user assigned textual
representation of a PVC.
SNMP-FRAMEWORK-MIBSnmpAdminStringr/w
Type Constraints:
range: 0..255
.1.3.6.1.2.1.10.44.1.5.1.12
This is a system supplied textual representation
of PVC. It is assigned by the service provider.
SNMP-FRAMEWORK-MIBSnmpAdminStringr/w
Type Constraints:
range: 0..255
.1.3.6.1.2.1.10.44.1.5.1.13
.1.3.6.1.2.1.10.44.1.6 · 1 row entry · 4 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk frAccountPVCTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FRNETSERV-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FRNETSERV-MIB::frAccountPVCTable'
The Frame Relay Accounting PVC table.  This table
is used to perform accounting on a PVC segment
end-point basis.
frAccountPVCEntry row .1.3.6.1.2.1.10.44.1.6.1
An entry in the Frame Relay Accounting PVC
table.
Column Syntax OID
The value of this object is equal to the DLCI

value for this PVC segment end-point.
Integer32
Constraints:
range: 16-4194303
.1.3.6.1.2.1.10.44.1.6.1.1
The value of this object is equal to the Segment
Size for this PVC segment end-point.
OctetsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.2.1.10.44.1.6.1.2
The value of this object is equal to the number
of segments received by this PVC segment end-
point.
SegmentsSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.6.1.3
The value of this object is equal to the number
of segments sent by this PVC segment end-point.
SegmentsSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.6.1.4
.1.3.6.1.2.1.10.44.1.7 · 1 row entry · 3 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk frAccountLportTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FRNETSERV-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FRNETSERV-MIB::frAccountLportTable'
The Frame Relay Accounting Logical Port table.
This table is used to perform accounting on a
UNI/NNI Logical Port basis.
frAccountLportEntry row .1.3.6.1.2.1.10.44.1.7.1
An entry in the Frame Relay Accounting Logical
Port table.
Indexes
Column Syntax OID
The value of this object is equal to the Segment
Size for this UNI/NNI logical port.
OctetsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.2.1.10.44.1.7.1.1
The value of this object is equal to the number
of segments received by this UNI/NNI logical
port.
SegmentsSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.7.1.2
The value of this object is equal to the number

of segments sent by this UNI/NNI logical port.
SegmentsSNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.44.1.7.1.3