frPVCEndptInCIR

FRNETSERV-MIB · .1.3.6.1.2.1.10.44.1.3.1.5

Object

column r/w Bits per SecondInteger32
The value of this object is equal to the
committed information rate (CIR) parameter
(measured in bits per second) for this PVC end-
point in the ingress direction (into the frame
relay network).
              
Note that the max value of this range is lower
than the max value allowed by Q.933 (2047 *
10**6).

Context

MIB
FRNETSERV-MIB
OID
.1.3.6.1.2.1.10.44.1.3.1.5
Type
column
Access
readwrite
Status
current
Units
Bits per Second
Parent
frPVCEndptEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FRNETSERV-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FRNETSERV-MIB::frPVCEndptInCIR'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'FRNETSERV-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FRNETSERV-MIB::frPVCEndptInCIR.<ifIndex>.<frPVCEndptDLCIIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'FRNETSERV-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'FRNETSERV-MIB::frPVCEndptInCIR'

Syntax

Bits per SecondInteger32

Values & Constraints

Object Constraints
range: 1-2147483647

Conformance

Member of
Compliance refinements
Write access is not required.
Write access is not required.