frMgtVCSigNetLinkRelErrors
FRNETSERV-MIB ·
.1.3.6.1.2.1.10.44.1.2.1.14
Object
The number of network-side local in-channel signaling link reliability errors (i.e., non- receipt of Status/Status Enquiry messages or invalid sequence numbers in a Link Integrity Verification Information Element) for this UNI/NNI logical port.
Context
- MIB
- FRNETSERV-MIB
- OID
.1.3.6.1.2.1.10.44.1.2.1.14- Type
- column
- Access
- readonly
- Status
- current
- Units
- Errors
- Parent
- frMgtVCSigEntry
- Table
- frMgtVCSigTable
- Siblings
- 24
Syntax
Errors SNMPv2-SMICounter32
- Source
- SNMPv2-SMICounter32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| frMgtVCSigProced The value of this object identifies the local
in-channel signaling procedural role that is used
for this UNI/NNI logical port. Bidirectional
procedures implies that both user-sid… | column | Enumeration | .1.3.6.1.2.1.10.44.1.2.1.1 |
| frMgtVCSigNetnT3 The value of this object identifies the Network-
side nT3 timer (for nN4 status enquires received)
value for this UNI/NNI logical port. If the
logical port is not performing netw… | column | Seconds Integer32 | .1.3.6.1.2.1.10.44.1.2.1.10 |
| frMgtVCSigUserLinkRelErrors The number of user-side local in-channel
signaling link reliability errors (i.e., non-
receipt of Status/Status Enquiry messages or
invalid sequence numbers in a Link Integrity
Ve… | column | Errors SNMPv2-SMICounter32 | .1.3.6.1.2.1.10.44.1.2.1.11 |
| frMgtVCSigUserProtErrors The number of user-side local in-channel
signaling protocol errors (i.e., protocol
discriminator, unnumbered information, message
type, call reference, and mandatory information
e… | column | Errors SNMPv2-SMICounter32 | .1.3.6.1.2.1.10.44.1.2.1.12 |
| frMgtVCSigUserChanInactive The number of times the user-side channel was
declared inactive (i.e., N392 errors in N393
events) for this UNI/NNI logical port. If the
logical port is not performing user-side
p… | column | Events SNMPv2-SMICounter32 | .1.3.6.1.2.1.10.44.1.2.1.13 |
| frMgtVCSigNetProtErrors The number of network-side local in-channel
signaling protocol errors (i.e., protocol
discriminator, message type, call reference, and
mandatory information element errors) for th… | column | Errors SNMPv2-SMICounter32 | .1.3.6.1.2.1.10.44.1.2.1.15 |
| frMgtVCSigNetChanInactive The number of times the network-side channel was
declared inactive (i.e., N392 errors in N393
events) for this UNI/NNI logical port. | column | Events SNMPv2-SMICounter32 | .1.3.6.1.2.1.10.44.1.2.1.16 |
| frMgtVCSigProcedAdmin The value of this object identifies the local
in-channel signaling procedural role that is used
for this UNI/NNI logical port. Bidirectional
procedures implies that both user-sid… | column | Enumeration | .1.3.6.1.2.1.10.44.1.2.1.17 |
| frMgtVCSigUserN391Admin The value of this object identifies the desired
User-side N391 full status polling cycle value for
this UNI/NNI logical port. If the logical port is
not performing user-side (bid… | column | Polls Integer32 | .1.3.6.1.2.1.10.44.1.2.1.18 |
| frMgtVCSigUserN392Admin The value of this object identifies the desired
User-side N392 error threshold value for this
UNI/NNI logical port. If the logical port is not
performing user-side (bidirectional… | column | Events Integer32 | .1.3.6.1.2.1.10.44.1.2.1.19 |
| frMgtVCSigUserN391 The value of this object identifies the User-side
N391 full status polling cycle value for this
UNI/NNI logical port. If the logical port is not
performing user-side (bidirection… | column | Polls Integer32 | .1.3.6.1.2.1.10.44.1.2.1.2 |
| frMgtVCSigUserN393Admin The value of this object identifies the desired
User-side N393 monitored events count value for
this UNI/NNI logical port. If the logical port is
not performing user-side (bidire… | column | Events Integer32 | .1.3.6.1.2.1.10.44.1.2.1.20 |
| frMgtVCSigUserT391Admin The value of this object identifies the desired
User-side T391 link integrity verification polling
timer value for this UNI/NNI logical port. If the
logical port is not performin… | column | Seconds Integer32 | .1.3.6.1.2.1.10.44.1.2.1.21 |
| frMgtVCSigNetN392Admin The value of this object identifies the desired
Network-side N392 error threshold value (nN2 for
LMI) for this UNI/NNI logical port. If the
logical port is not performing network… | column | Events Integer32 | .1.3.6.1.2.1.10.44.1.2.1.22 |
| frMgtVCSigNetN393Admin The value of this object identifies the desired
Network-side N393 monitored events count value
(nN3 for LMI) for this UNI/NNI logical port. If
the logical port is not performing … | column | Events Integer32 | .1.3.6.1.2.1.10.44.1.2.1.23 |
| frMgtVCSigNetT392Admin The value of this object identifies the desired
Network-side T392 polling verification timer value
(nT2 for LMI) for this UNI/NNI logical port. If
the logical port is not perform… | column | Seconds Integer32 | .1.3.6.1.2.1.10.44.1.2.1.24 |
| frMgtVCSigNetnT3Admin The value of this object identifies the desired
Network-side nT3 timer (for nN4 status enquires
received) value for this UNI/NNI logical port. If
the logical port is not performin… | column | Seconds Integer32 | .1.3.6.1.2.1.10.44.1.2.1.25 |
| frMgtVCSigUserN392 The value of this object identifies the User-side
N392 error threshold value for this UNI/NNI
logical port. If the logical port is not
performing user-side (bidirectional) proced… | column | Events Integer32 | .1.3.6.1.2.1.10.44.1.2.1.3 |
| frMgtVCSigUserN393 The value of this object identifies the User-side
N393 monitored events count value for this UNI/NNI
logical port. If the logical port is not
performing user-side (bidirectional)… | column | Events Integer32 | .1.3.6.1.2.1.10.44.1.2.1.4 |
| frMgtVCSigUserT391 The value of this object identifies the User-side
T391 link integrity verification polling timer
value for this UNI/NNI logical port. If the
logical port is not performing user-s… | column | Seconds Integer32 | .1.3.6.1.2.1.10.44.1.2.1.5 |
| frMgtVCSigNetN392 The value of this object identifies the Network-
side N392 error threshold value (nN2 for LMI) for
this UNI/NNI logical port. If the logical port is
not performing network-side p… | column | Events Integer32 | .1.3.6.1.2.1.10.44.1.2.1.6 |
| frMgtVCSigNetN393 The value of this object identifies the Network-
side N393 monitored events count value (nN3 for
LMI) for this UNI/NNI logical port. If the
logical port is not performing network… | column | Events Integer32 | .1.3.6.1.2.1.10.44.1.2.1.7 |
| frMgtVCSigNetT392 The value of this object identifies the Network-
side T392 polling verification timer value (nT2
for LMI) for this UNI/NNI logical port. If the
logical port is not performing ne… | column | Seconds Integer32 | .1.3.6.1.2.1.10.44.1.2.1.8 |
| frMgtVCSigNetnN4 The value of this object identifies the Network-
side nN4 maximum status enquires received value
for this UNI/NNI logical port. If the logical
port is not performing network-side… | column | Events Integer32 | .1.3.6.1.2.1.10.44.1.2.1.9 |