frPVCEndptTable
FRNETSERV-MIB ·
.1.3.6.1.2.1.10.44.1.3
Object
table
The Frame Relay PVC End-Point table. This table
is used to model a PVC end-point. This table
contains the traffic parameters and statistics for
a PVC end-point.
This table is used to identify the traffic
parameters for a bi-directional PVC segment end-
point, and it also provides statistics for a PVC
segment end-point.
A PVC segment end-point is identified by a UNI/NNI
logical port index value and DLCI index value.
If the frame relay service provider allows the
frame relay CNM subscriber to create, modify or
delete PVCs using SNMP, then this table is used to
identify and reserve the requested traffic
parameters of each PVC segment end-point. The
Connection table is used to 'connect' the end-
points together. Not all implementations will
support the capability of
creating/modifying/deleting PVCs using SNMP as a
feature of frame relay CNM service.
Uni-directional PVCs are modeled with zero valued
traffic parameters in one of the directions (In or
Out direction) in this table.
To create a PVC, the following procedures shall be
followed:
1) Create the entries for the PVC segment
endpoints in the frPVCEndptTable by specifying
the traffic parameters for the bi-directional
PVC segment endpoints. As shown in figure 2, a
point-to-point PVC has two endpoints, thus two
entries in this table. Uni-directional PVCs
are modeled with zero valued traffic
parameters in one direction; all the `In'
direction parameters for one frame relay PVC
End-point or all the `Out' direction
parameters for the other frame relay PVC
Endpoint.
In _____________________________ Out
>>>>>>| |>>>>>>>>
______| Frame Relay Network |________
Out | | In
<<<<<<|_____________________________|<<<<<<<<
Frame Relay Frame Relay
PVC PVC
Endpoint Endpoint
Figure 2, PVC Terminology
2) Go to the Frame Relay Connection Group.
Context
- MIB
- FRNETSERV-MIB
- OID
.1.3.6.1.2.1.10.44.1.3- Type
- table
- Status
- current
- Parent
- frnetservObjects
- Siblings
- 6
- Children
- 1
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| frLportTable The Frame Relay Logical Port Information table is
an interface-specific addendum to the generic
ifTable of the Interface MIB. | table | - | .1.3.6.1.2.1.10.44.1.1 |
| frMgtVCSigTable The Frame Relay Management VC Signaling
Parameters and Errors table. | table | - | .1.3.6.1.2.1.10.44.1.2 |
| frPVCConnectIndexValue This object returns a hint to be used for
frPVCConnectIndex when creating entries in the
frPVCConnectTable.
The value 0 indicates that no unassigned entries
are availab… | scalar | Integer32 | .1.3.6.1.2.1.10.44.1.4 |
| frPVCConnectTable The Frame Relay PVC Connect Table is used to
model the bi-directional PVC segment flows
including: point-to-point PVCs, point-to-
multipoint PVCs, and multipoint-to-multipoint
PV… | table | - | .1.3.6.1.2.1.10.44.1.5 |
| frAccountPVCTable The Frame Relay Accounting PVC table. This table
is used to perform accounting on a PVC segment
end-point basis. | table | - | .1.3.6.1.2.1.10.44.1.6 |
| frAccountLportTable The Frame Relay Accounting Logical Port table.
This table is used to perform accounting on a
UNI/NNI Logical Port basis. | table | - | .1.3.6.1.2.1.10.44.1.7 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| frPVCEndptEntry An entry in the Frame Relay PVC Endpoint table. | row | - | .1.3.6.1.2.1.10.44.1.3.1 |