RFC1382-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
7
Rows
7
Columns
144

x25AdmnTable

table mandatory
.1.3.6.1.2.1.10.5.1 · 1 row entry · 24 columns
This table contains the administratively
set configuration parameters for an X.25
Packet Level Entity (PLE).
          
Most of the objects in this table have
corresponding objects in the x25OperTable.
This table contains the values as last set
by the administrator.  The x25OperTable
contains the values actually in use by an
X.25 PLE.
          
Changing an administrative value may or may
not change a current operating value.  The
operating value may not change until the
interface is restarted.  Some
implementations may change the values
immediately upon changing the administrative
table.  All implementations are required to
load the values from the administrative
table when initializing a PLE.
x25AdmnEntry entry .1.3.6.1.2.1.10.5.1.1
Entries of x25AdmnTable.
Indexes
x25AdmnIndex
Column Syntax OID
x25AdmnIndex mandatory
The ifIndex value for the X.25 Interface.
RFC1381-MIBIfIndexType
Textual Convention: RFC1381-MIBIfIndexType Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.2.1.10.5.1.1.1
x25AdmnInterfaceMode mandatory
Identifies DCE/DTE mode in which the
interface operates. A value of dxe
indicates the mode will be determined by XID
negotiation.
Enumerationr/w
Enumerated Values:
1dte
2dce
3dxe
.1.3.6.1.2.1.10.5.1.1.2
x25AdmnMaxActiveCircuits mandatory
The maximum number of circuits this PLE can
support; including PVCs.
Integer32r/w
Constraints:
range: 0-4096
.1.3.6.1.2.1.10.5.1.1.3
x25AdmnPacketSequencing mandatory
The modulus of the packet sequence number
space.
Enumerationr/w
Enumerated Values:
1modulo8
2modulo128
.1.3.6.1.2.1.10.5.1.1.4
x25AdmnRestartTimer mandatory
The T20 restart timer in milliseconds.
RFC1381-MIBPositiveIntegerr/w
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.1.1.5
x25AdmnCallTimer mandatory
The T21 Call timer in milliseconds.
RFC1381-MIBPositiveIntegerr/w
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.1.1.6
x25AdmnResetTimer mandatory
The T22 Reset timer in milliseconds.
RFC1381-MIBPositiveIntegerr/w
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.1.1.7
x25AdmnClearTimer mandatory
The T23 Clear timer in milliseconds.
RFC1381-MIBPositiveIntegerr/w
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.1.1.8
x25AdmnWindowTimer mandatory
The T24 window status transmission timer in
milliseconds. A value of 2147483647
indicates no window timer in use.
RFC1381-MIBPositiveIntegerr/w
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.1.1.9
x25AdmnDataRxmtTimer mandatory
The T25 data retransmission timer in

milliseconds. A value of 2147483647
indicates no data retransmission timer in
use.
RFC1381-MIBPositiveIntegerr/w
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.1.1.10
x25AdmnInterruptTimer mandatory
The T26 interrupt timer in milliseconds. A
value of 2147483647 indicates no interrupt
timer in use.
RFC1381-MIBPositiveIntegerr/w
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.1.1.11
x25AdmnRejectTimer mandatory
The T27 Reject retransmission timer in
milliseconds. A value of 2147483647
indicates no reject timer in use.
RFC1381-MIBPositiveIntegerr/w
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.1.1.12
x25AdmnRegistrationRequestTimer mandatory
The T28 registration timer in milliseconds.
A value of 2147483647 indicates no
registration timer in use.
RFC1381-MIBPositiveIntegerr/w
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.1.1.13
x25AdmnMinimumRecallTimer mandatory
Minimum time interval between unsuccessful
call attempts in milliseconds.
RFC1381-MIBPositiveIntegerr/w
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.1.1.14
x25AdmnRestartCount mandatory
The R20 restart retransmission count.
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.2.1.10.5.1.1.15
x25AdmnResetCount mandatory
The r22 Reset retransmission count.
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.2.1.10.5.1.1.16
x25AdmnClearCount mandatory
The r23 Clear retransmission count.
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.2.1.10.5.1.1.17
x25AdmnDataRxmtCount mandatory
The R25 Data retransmission count. This
value is irrelevant if the
x25AdmnDataRxmtTimer indicates no timer in
use.
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.2.1.10.5.1.1.18
x25AdmnRejectCount mandatory
The R27 reject retransmission count. This
value is irrelevant if the
x25AdmnRejectTimer indicates no timer in
use.
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.2.1.10.5.1.1.19
x25AdmnRegistrationRequestCount mandatory
The R28 Registration retransmission Count.
This value is irrelevant if the
x25AdmnRegistrationRequestTimer indicates no
timer in use.
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.2.1.10.5.1.1.20
x25AdmnNumberPVCs mandatory
The number of PVC configured for this PLE.
The PVCs use channel numbers from 1 to this
number.
Integer32r/w
Constraints:
range: 0-4096
.1.3.6.1.2.1.10.5.1.1.21
x25AdmnDefCallParamId mandatory
This identifies the instance of the
x25CallParmIndex for the entry in the
x25CallParmTable which contains the default
call parameters for this PLE.
ObjectIdentifierr/w .1.3.6.1.2.1.10.5.1.1.22
x25AdmnLocalAddress mandatory
The local address for this PLE subnetwork.
A zero length address maybe returned by PLEs
that only support PVCs.
X121Addressr/w
Textual Convention: X121Address OctetString
Type Constraints:
range: 0..17
.1.3.6.1.2.1.10.5.1.1.23
x25AdmnProtocolVersionSupported mandatory
Identifies the version of the X.25 protocol
this interface should support. Object
identifiers for common versions are defined
below in the x25ProtocolVersion subtree.
ObjectIdentifierr/w .1.3.6.1.2.1.10.5.1.1.24

x25OperTable

table mandatory
.1.3.6.1.2.1.10.5.2 · 1 row entry · 25 columns
The operation parameters in use by the X.25
PLE.
x25OperEntry entry .1.3.6.1.2.1.10.5.2.1
Entries of x25OperTable.
Indexes
x25OperIndex
Column Syntax OID
x25OperIndex mandatory
The ifIndex value for the X.25 interface.
RFC1381-MIBIfIndexType
Textual Convention: RFC1381-MIBIfIndexType Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.2.1.10.5.2.1.1
x25OperInterfaceMode mandatory
Identifies DCE/DTE mode in which the
interface operates. A value of dxe
indicates the role will be determined by XID
negotiation at the Link Layer and that
negotiation has not yet taken place.
Enumeration
Enumerated Values:
1dte
2dce
3dxe
.1.3.6.1.2.1.10.5.2.1.2
x25OperMaxActiveCircuits mandatory
Maximum number of circuits this PLE can
support.
Integer32
Constraints:
range: 0-4096
.1.3.6.1.2.1.10.5.2.1.3
x25OperPacketSequencing mandatory
The modulus of the packet sequence number
space.
Enumeration
Enumerated Values:
1modulo8
2modulo128
.1.3.6.1.2.1.10.5.2.1.4
x25OperRestartTimer mandatory
The T20 restart timer in milliseconds.
RFC1381-MIBPositiveInteger
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.2.1.5
x25OperCallTimer mandatory
The T21 Call timer in milliseconds.
RFC1381-MIBPositiveInteger
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.2.1.6
x25OperResetTimer mandatory
The T22 Reset timer in milliseconds.
RFC1381-MIBPositiveInteger
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.2.1.7
x25OperClearTimer mandatory
The T23 Clear timer in milliseconds.
RFC1381-MIBPositiveInteger
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.2.1.8
x25OperWindowTimer mandatory
The T24 window status transmission timer

milliseconds. A value of 2147483647
indicates no window timer in use.
RFC1381-MIBPositiveInteger
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.2.1.9
x25OperDataRxmtTimer mandatory
The T25 Data Retransmission timer in
milliseconds. A value of 2147483647
indicates no data retransmission timer in
use.
RFC1381-MIBPositiveInteger
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.2.1.10
x25OperInterruptTimer mandatory
The T26 Interrupt timer in milliseconds. A
value of 2147483647 indicates interrupts are
not being used.
RFC1381-MIBPositiveInteger
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.2.1.11
x25OperRejectTimer mandatory
The T27 Reject retransmission timer in
milliseconds. A value of 2147483647
indicates no reject timer in use.
RFC1381-MIBPositiveInteger
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.2.1.12
x25OperRegistrationRequestTimer mandatory
The T28 registration timer in milliseconds.
A value of 2147483647 indicates no
registration timer in use.
RFC1381-MIBPositiveInteger
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.2.1.13
x25OperMinimumRecallTimer mandatory
Minimum time interval between unsuccessful
call attempts in milliseconds.
RFC1381-MIBPositiveInteger
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.2.1.14
x25OperRestartCount mandatory
The R20 restart retransmission count.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.2.1.10.5.2.1.15
x25OperResetCount mandatory
The r22 Reset retransmission count.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.2.1.10.5.2.1.16
x25OperClearCount mandatory
The r23 Clear retransmission count.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.2.1.10.5.2.1.17
x25OperDataRxmtCount mandatory
The R25 Data retransmission count. This
value is undefined if the
x25OperDataRxmtTimer indicates no timer in
use.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.2.1.10.5.2.1.18
x25OperRejectCount mandatory
The R27 reject retransmission count. This
value is undefined if the x25OperRejectTimer
indicates no timer in use.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.2.1.10.5.2.1.19
x25OperRegistrationRequestCount mandatory
The R28 Registration retransmission Count.
This value is undefined if the
x25OperREgistrationRequestTimer indicates no
timer in use.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.2.1.10.5.2.1.20
x25OperNumberPVCs mandatory
The number of PVC configured for this PLE.
The PVCs use channel numbers from 1 to this
number.
Integer32
Constraints:
range: 0-4096
.1.3.6.1.2.1.10.5.2.1.21
x25OperDefCallParamId mandatory
This identifies the instance of the
x25CallParmIndex for the entry in the
x25CallParmTable that contains the default
call parameters for this PLE.
ObjectIdentifier .1.3.6.1.2.1.10.5.2.1.22
x25OperLocalAddress mandatory
The local address for this PLE subnetwork.
A zero length address maybe returned by PLEs
that only support PVCs.
X121Address
Textual Convention: X121Address OctetString
Type Constraints:
range: 0..17
.1.3.6.1.2.1.10.5.2.1.23
x25OperDataLinkId mandatory
This identifies the instance of the index
object in the first table of the most device
specific MIB for the interface used by this
PLE.
ObjectIdentifier .1.3.6.1.2.1.10.5.2.1.24
x25OperProtocolVersionSupported mandatory
Identifies the version of the X.25 protocol
this interface supports. Object identifiers
for common versions are defined below in the
x25ProtocolVersion subtree.
ObjectIdentifier .1.3.6.1.2.1.10.5.2.1.25

x25StatTable

table mandatory
.1.3.6.1.2.1.10.5.3 · 1 row entry · 25 columns
Statistics information about this X.25
PLE.
x25StatEntry entry .1.3.6.1.2.1.10.5.3.1
Entries of the x25StatTable.
Indexes
x25StatIndex
Column Syntax OID
x25StatIndex mandatory
The ifIndex value for the X.25 interface.
RFC1381-MIBIfIndexType
Textual Convention: RFC1381-MIBIfIndexType Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.2.1.10.5.3.1.1
x25StatInCalls mandatory
The number of incoming calls received.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.2
x25StatInCallRefusals mandatory
The number of incoming calls refused. This
includes calls refused by the PLE and by
higher layers. This also includes calls
cleared because of restricted fast select.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.3
x25StatInProviderInitiatedClears mandatory
The number of clear requests with a cause
code other than DTE initiated.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.4
x25StatInRemotelyInitiatedResets mandatory
The number of reset requests received with

cause code DTE initiated.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.5
x25StatInProviderInitiatedResets mandatory
The number of reset requests received with
cause code other than DTE initiated.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.6
x25StatInRestarts mandatory
The number of remotely initiated (including
provider initiated) restarts experienced by
the PLE excluding the restart associated
with bringing up the PLE interface. This
only counts restarts received when the PLE
alrea…
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.7
x25StatInDataPackets mandatory
The number of data packets received.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.8
x25StatInAccusedOfProtocolErrors mandatory
The number of packets received containing a
procedure error cause code. These include
clear, reset, restart, or diagnostic
packets.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.9
x25StatInInterrupts mandatory
The number of interrupt packets received by
the PLE or over the PVC/VC.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.10
x25StatOutCallAttempts mandatory
The number of calls attempted.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.11
x25StatOutCallFailures mandatory
The number of call attempts which failed.
This includes calls that were cleared
because of restrictive fast select.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.12
x25StatOutInterrupts mandatory
The number of interrupt packets send by the
PLE or over the PVC/VC.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.13
x25StatOutDataPackets mandatory
The number of data packets sent by this
PLE.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.14
x25StatOutgoingCircuits mandatory
The number of active outgoing circuits.
This includes call requests sent but not yet
confirmed. This does not count PVCs.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.15
x25StatIncomingCircuits mandatory
The number of active Incoming Circuits.
This includes call indications received but
not yet acknowledged. This does not count
PVCs.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.16
x25StatTwowayCircuits mandatory
The number of active two-way Circuits.
This includes call requests sent but not yet
confirmed. This does not count PVCs.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.17
x25StatRestartTimeouts mandatory
The number of times the T20 restart timer
expired.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.18
x25StatCallTimeouts mandatory
The number of times the T21 call timer
expired.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.19
x25StatResetTimeouts mandatory
The number of times the T22 reset timer
expired.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.20
x25StatClearTimeouts mandatory
The number of times the T23 clear timer
expired.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.21
x25StatDataRxmtTimeouts mandatory
The number of times the T25 data timer
expired.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.22
x25StatInterruptTimeouts mandatory
The number of times the T26 interrupt timer
expired.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.23
x25StatRetryCountExceededs mandatory
The number of times a retry counter was
exhausted.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.24
x25StatClearCountExceededs mandatory
The number of times the R23 clear count was
exceeded.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.3.1.25

x25ChannelTable

table mandatory
.1.3.6.1.2.1.10.5.4 · 1 row entry · 7 columns
These objects contain information about the
channel number configuration in an X.25 PLE.
These values are the configured values.
changes in these values after the interfaces
has started may not be reflected in the
operating PLE.
x25ChannelEntry entry .1.3.6.1.2.1.10.5.4.1
Entries of x25ChannelTable.
Indexes
x25ChannelIndex
Column Syntax OID
x25ChannelIndex mandatory
The ifIndex value for the X.25 Interface.
RFC1381-MIBIfIndexType
Textual Convention: RFC1381-MIBIfIndexType Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.2.1.10.5.4.1.1
x25ChannelLIC mandatory
Lowest Incoming channel.
Integer32r/w
Constraints:
range: 0-4095
.1.3.6.1.2.1.10.5.4.1.2
x25ChannelHIC mandatory
Highest Incoming channel. A value of zero
indicates no channels in this range.
Integer32r/w
Constraints:
range: 0-4095
.1.3.6.1.2.1.10.5.4.1.3
x25ChannelLTC mandatory
Lowest Two-way channel.
Integer32r/w
Constraints:
range: 0-4095
.1.3.6.1.2.1.10.5.4.1.4
x25ChannelHTC mandatory
Highest Two-way channel. A value of zero
indicates no channels in this range.
Integer32r/w
Constraints:
range: 0-4095
.1.3.6.1.2.1.10.5.4.1.5
x25ChannelLOC mandatory
Lowest outgoing channel.
Integer32r/w
Constraints:
range: 0-4095
.1.3.6.1.2.1.10.5.4.1.6
x25ChannelHOC mandatory
Highest outgoing channel. A value of zero

indicates no channels in this range.
Integer32r/w
Constraints:
range: 0-4095
.1.3.6.1.2.1.10.5.4.1.7

x25CircuitTable

table mandatory
.1.3.6.1.2.1.10.5.5 · 1 row entry · 21 columns
These objects contain general information
about a specific circuit of an X.25 PLE.
x25CircuitEntry entry .1.3.6.1.2.1.10.5.5.1
Entries of x25CircuitTable.
Indexes
x25CircuitIndex x25CircuitChannel
Column Syntax OID
x25CircuitIndex mandatory
The ifIndex value for the X.25 Interface.
RFC1381-MIBIfIndexType
Textual Convention: RFC1381-MIBIfIndexType Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.2.1.10.5.5.1.1
x25CircuitChannel mandatory
The channel number for this circuit.
Integer32
Constraints:
range: 0-4095
.1.3.6.1.2.1.10.5.5.1.2
x25CircuitStatus mandatory
This object reports the current status of
the circuit.

An existing instance of this object can only
be set to startClear, startPvcResetting, or
invalid. An instance with the value calling
or open can onl…
Enumerationr/w
Enumerated Values:
1invalid
2closed
3calling
4open
5clearing
6pvc
7pvcResetting
8startClear
9startPvcResetting
10other
.1.3.6.1.2.1.10.5.5.1.3
x25CircuitEstablishTime mandatory
The value of sysUpTime when the channel was
associated with this circuit. For outgoing
SVCs, this is the time the first call packet
was sent. For incoming SVCs, this is the
time the call indication was received. For
RFC1155-SMITimeTicks
Textual Convention: RFC1155-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.5.1.4
x25CircuitDirection mandatory
The direction of the call that established
this circuit.
Enumerationr/w
Enumerated Values:
1incoming
2outgoing
3pvc
.1.3.6.1.2.1.10.5.5.1.5
x25CircuitInOctets mandatory
The number of octets of user data delivered
to upper layer.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.5.1.6
x25CircuitInPdus mandatory
The number of PDUs received for this
circuit.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.5.1.7
x25CircuitInRemotelyInitiatedResets mandatory
The number of Resets received for this
circuit with cause code of DTE initiated.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.5.1.8
x25CircuitInProviderInitiatedResets mandatory
The number of Resets received for this
circuit with cause code other than DTE
initiated.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.5.1.9
x25CircuitInInterrupts mandatory
The number of interrupt packets received
for this circuit.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.5.1.10
x25CircuitOutOctets mandatory
The number of octets of user data sent for
this circuit.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.5.1.11
x25CircuitOutPdus mandatory
The number of PDUs sent for this circuit.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.5.1.12
x25CircuitOutInterrupts mandatory
The number of interrupt packets sent on
this circuit.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.5.1.13
x25CircuitDataRetransmissionTimeouts mandatory
The number of times the T25 data
retransmission timer expired for this
circuit.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.5.1.14
x25CircuitResetTimeouts mandatory
The number of times the T22 reset timer
expired for this circuit.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.5.1.15
x25CircuitInterruptTimeouts mandatory
The number of times the T26 Interrupt timer
expired for this circuit.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.5.1.16
x25CircuitCallParamId mandatory
This identifies the instance of the
x25CallParmIndex for the entry in the
x25CallParmTable which contains the call
parameters in use with this circuit. The
entry referenced must contain the values
that are currently in…
ObjectIdentifierr/w .1.3.6.1.2.1.10.5.5.1.17
x25CircuitCalledDteAddress mandatory
For incoming calls, this is the called
address from the call indication packet.
For outgoing calls, this is the called

address from the call confirmation packet.
This will be zero length for PVCs.
X121Addressr/w
Textual Convention: X121Address OctetString
Type Constraints:
range: 0..17
.1.3.6.1.2.1.10.5.5.1.18
x25CircuitCallingDteAddress mandatory
For incoming calls, this is the calling
address from the call indication packet.
For outgoing calls, this is the calling
address from the call confirmation packet.
This will be zero length for PVCs.
X121Addressr/w
Textual Convention: X121Address OctetString
Type Constraints:
range: 0..17
.1.3.6.1.2.1.10.5.5.1.19
x25CircuitOriginallyCalledAddress mandatory
For incoming calls, this is the address in
the call Redirection or Call Deflection
Notification facility if the call was
deflected or redirected, otherwise it will
be called address from the call indication
packet. For…
X121Addressr/w
Textual Convention: X121Address OctetString
Type Constraints:
range: 0..17
.1.3.6.1.2.1.10.5.5.1.20
x25CircuitDescr mandatory
A descriptive string associated with this
circuit. This provides a place for the
agent to supply any descriptive information
it knows about the use or owner of the
circuit. The agent may return the process
identifier …
OctetStringr/w
Constraints:
range: 0-255
.1.3.6.1.2.1.10.5.5.1.21

x25ClearedCircuitTable

table mandatory
.1.3.6.1.2.1.10.5.8 · 1 row entry · 12 columns
A table of entries about closed circuits.
Entries must be made in this table whenever
circuits are closed and the close request or
close indication packet contains a clearing
cause other than DTE Originated or a
Diagnostic code field other than Higher
Layer Initiated disconnection-normal.  An
agent may optionally make entries for normal
closes (to record closing facilities or
          
other information).
          
Agents will delete the oldest entry in the
table when adding a new entry would exceed
agent resources.  Agents are required to
keep the last entry put in the table and may
keep more entries.  The object
x25OperClearEntriesGranted returns the
maximum number of entries kept in the
table.
x25ClearedCircuitEntry entry .1.3.6.1.2.1.10.5.8.1
Information about a cleared circuit.
Indexes
x25ClearedCircuitIndex
Column Syntax OID
x25ClearedCircuitIndex mandatory
An index that uniquely distinguishes one
entry in the clearedCircuitTable from
another. This index will start at
2147483647 and will decrease by one for each
new entry added to the table. Upon reaching
one, the index …
RFC1381-MIBPositiveInteger
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.8.1.1
x25ClearedCircuitPleIndex mandatory
The value of ifIndex for the PLE which
cleared the circuit that created the entry.
RFC1381-MIBIfIndexType
Textual Convention: RFC1381-MIBIfIndexType Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.2.1.10.5.8.1.2
x25ClearedCircuitTimeEstablished mandatory
The value of sysUpTime when the circuit was
established. This will be the same value
that was in the x25CircuitEstablishTime for
the circuit.
RFC1155-SMITimeTicks
Textual Convention: RFC1155-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.8.1.3
x25ClearedCircuitTimeCleared mandatory
The value of sysUpTime when the circuit was
cleared. For locally initiated clears, this

will be the time when the clear confirmation
was received. For remotely initiated
clears, this will be the time wh…
RFC1155-SMITimeTicks
Textual Convention: RFC1155-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.8.1.4
x25ClearedCircuitChannel mandatory
The channel number for the circuit that was
cleared.
Integer32
Constraints:
range: 0-4095
.1.3.6.1.2.1.10.5.8.1.5
x25ClearedCircuitClearingCause mandatory
The Clearing Cause from the clear request
or clear indication packet that cleared the
circuit.
Integer32
Constraints:
range: 0-255
.1.3.6.1.2.1.10.5.8.1.6
x25ClearedCircuitDiagnosticCode mandatory
The Diagnostic Code from the clear request
or clear indication packet that cleared the
circuit.
Integer32
Constraints:
range: 0-255
.1.3.6.1.2.1.10.5.8.1.7
x25ClearedCircuitInPdus mandatory
The number of PDUs received on the
circuit.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.8.1.8
x25ClearedCircuitOutPdus mandatory
The number of PDUs transmitted on the
circuit.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.5.8.1.9
x25ClearedCircuitCalledAddress mandatory
The called address from the cleared
circuit.
X121Address
Textual Convention: X121Address OctetString
Type Constraints:
range: 0..17
.1.3.6.1.2.1.10.5.8.1.10
x25ClearedCircuitCallingAddress mandatory
The calling address from the cleared
circuit.
X121Address
Textual Convention: X121Address OctetString
Type Constraints:
range: 0..17
.1.3.6.1.2.1.10.5.8.1.11
x25ClearedCircuitClearFacilities mandatory
The facilities field from the clear request
or clear indication packet that cleared the
circuit. A size of zero indicates no
facilities were present.
OctetString
Constraints:
range: 0-109
.1.3.6.1.2.1.10.5.8.1.12

x25CallParmTable

table mandatory
.1.3.6.1.2.1.10.5.9 · 1 row entry · 30 columns
These objects contain the parameters that
can be varied between X.25 calls.  The
entries in this table are independent of the
PLE.  There exists only one of these tables
for the entire system.  The indexes for the
entries are independent of any PLE or any
circuit.  Other tables reference entries in
this table.  Entries in this table can be
used for default PLE parameters, for
parameters to use to place/answer a call,
for the parameters currently in use for a
circuit, or parameters that were used by a
circuit.
          
The number of references to a given set of
parameters can be found in the
x25CallParmRefCount object sharing the same
instance identifier with the parameters.
The value of this reference count also
affects the access of the objects in this
table.  An object in this table with the
same instance identifier as the instance
identifier of an x25CallParmRefCount must be
consider associated with that reference
count.  An object with an associated
reference count of zero can be written (if
its ACCESS clause allows it).  An object
with an associated reference count greater
than zero can not be written (regardless of
the ACCESS clause).  This ensures that a set
of call parameters being referenced from
another table can not be modified or changed
in a ways inappropriate for continued use by
that table.
x25CallParmEntry entry .1.3.6.1.2.1.10.5.9.1
Entries of x25CallParmTable.
Indexes
x25CallParmIndex
Column Syntax OID
x25CallParmIndex mandatory
A value that distinguishes this entry from
another entry. Entries in this table are
referenced from other objects which identify
call parameters.

It is impossible to know which other objects
in the MIB r…
RFC1381-MIBPositiveInteger
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.9.1.1
x25CallParmStatus mandatory
The status of this call parameter entry.
See RFC 1271 for details of usage.
RFC1271-MIBEntryStatusr/w
Textual Convention: RFC1271-MIBEntryStatus Enumeration
Type Values:
1valid
2createRequest
3underCreation
4invalid
.1.3.6.1.2.1.10.5.9.1.2
x25CallParmRefCount mandatory
The number of references know by a
management station to exist to this set of
call parameters. This is the number of
other objects that have returned a value of,
and will return a value of, the index for
this set of ca…
RFC1381-MIBPositiveInteger
Textual Convention: RFC1381-MIBPositiveInteger Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.10.5.9.1.3
x25CallParmInPacketSize mandatory
The maximum receive packet size in octets
for a circuit. A size of zero for a circuit
means use the PLE default size. A size of
zero for the PLE means use a default size of
128.
Integer32r/w
Constraints:
range: 0-4096
.1.3.6.1.2.1.10.5.9.1.4
x25CallParmOutPacketSize mandatory
The maximum transmit packet size in octets
for a circuit. A size of zero for a circuit
means use the PLE default size. A size of
zero for the PLE default means use a default
size of 128.
Integer32r/w
Constraints:
range: 0-4096
.1.3.6.1.2.1.10.5.9.1.5
x25CallParmInWindowSize mandatory
The receive window size for a circuit. A
size of zero for a circuit means use the PLE
default size. A size of zero for the PLE
default means use 2.
Integer32r/w
Constraints:
range: 0-127
.1.3.6.1.2.1.10.5.9.1.6
x25CallParmOutWindowSize mandatory
The transmit window size for a circuit. A
size of zero for a circuit means use the PLE
default size. A size of zero for the PLE
default means use 2.
Integer32r/w
Constraints:
range: 0-127
.1.3.6.1.2.1.10.5.9.1.7
x25CallParmAcceptReverseCharging mandatory
An enumeration defining if the PLE will
accept or refuse charges. A value of
default for a circuit means use the PLE
default value. A value of neverAccept is
only used for the PLE default and indicates
the PLE will ne…
Enumerationr/w
Enumerated Values:
1default
2accept
3refuse
4neverAccept
.1.3.6.1.2.1.10.5.9.1.8
x25CallParmProposeReverseCharging mandatory
An enumeration defining if the PLE should
propose reverse or local charging. The
value of default for a circuit means use the
PLE default. The value of default for the
PLE default means use local.
Enumerationr/w
Enumerated Values:
1default
2reverse
3local
.1.3.6.1.2.1.10.5.9.1.9
x25CallParmFastSelect mandatory
Expresses preference for use of fast select
facility. The value of default for a
circuit is the PLE default. A value of

default for the PLE means noFastSelect. A
value of noFastSelect or
noRestrictedFa…
Enumerationr/w
Enumerated Values:
1default
2notSpecified
3fastSelect
4restrictedFastResponse
5noFastSelect
6noRestrictedFastResponse
.1.3.6.1.2.1.10.5.9.1.10
x25CallParmInThruPutClasSize mandatory
The incoming throughput class to negotiate.
A value of tcDefault for a circuit means use
the PLE default. A value of tcDefault for
the PLE default means tcNone. A value of
tcNone means do not negotiate throughtput
cla…
Enumerationr/w
Enumerated Values:
1tcReserved1
2tcReserved2
3tc75
4tc150
5tc300
6tc600
7tc1200
8tc2400
9tc4800
10tc9600
11tc19200
12tc48000
13tc64000
14tcReserved14
15tcReserved15
16tcReserved0
17tcNone
18tcDefault
.1.3.6.1.2.1.10.5.9.1.11
x25CallParmOutThruPutClasSize mandatory
The outgoing throughput class to negotiate.
A value of tcDefault for a circuit means use
the PLE default. A value of tcDefault for
the PLE default means use tcNone. A value
of tcNone means do not negotiate throughtput…
Enumerationr/w
Enumerated Values:
1tcReserved1
2tcReserved2
3tc75
4tc150
5tc300
6tc600
7tc1200
8tc2400
9tc4800
10tc9600
11tc19200
12tc48000
13tc64000
14tcReserved14
15tcReserved15
16tcReserved0
17tcNone
18tcDefault
.1.3.6.1.2.1.10.5.9.1.12
x25CallParmCug mandatory
The Closed User Group to specify. This
consists of two or four octets containing
the characters 0 through 9. A zero length
string indicates no facility requested. A
string length of three containing the
characters DE…
OctetStringr/w
Constraints:
range: 0-4
.1.3.6.1.2.1.10.5.9.1.13
x25CallParmCugoa mandatory
The Closed User Group with Outgoing Access
to specify. This consists of two or four
octets containing the characters 0 through
9. A string length of three containing the
characters DEF for a circuit means use the
PLE …
OctetStringr/w
Constraints:
range: 0-4
.1.3.6.1.2.1.10.5.9.1.14
x25CallParmBcug mandatory
The Bilateral Closed User Group to specify.
This consists of two octets containing the
characters 0 through 9. A string length of
three containing the characters DEF for a
circuit means use the PLE default (the PLE
def…
OctetStringr/w
Constraints:
range: 0-3
.1.3.6.1.2.1.10.5.9.1.15
x25CallParmNui mandatory
The Network User Identifier facility. This
is binary value to be included immediately
after the length field. The PLE will supply
the length octet. A zero length string
indicates no facility requested. This value
is…
OctetStringr/w
Constraints:
range: 0-108
.1.3.6.1.2.1.10.5.9.1.16
x25CallParmChargingInfo mandatory
The charging Information facility. A value
of default for a circuit means use the PLE
default. The value of default for the
default PLE parameters means use noFacility.
The value of noFacility means do not include
a f…
Enumerationr/w
Enumerated Values:
1default
2noFacility
3noChargingInfo
4chargingInfo
.1.3.6.1.2.1.10.5.9.1.17
x25CallParmRpoa mandatory
The RPOA facility. The octet string
contains n * 4 sequences of the characters
0-9 to specify a facility with n entries.
The octet string containing the 3 characters
DEF for a circuit specifies use of the PLE
default (…
OctetStringr/w
Constraints:
range: 0-108
.1.3.6.1.2.1.10.5.9.1.18
x25CallParmTrnstDly mandatory
The Transit Delay Selection and Indication
value. A value of 65536 indicates no
facility requested. A value of 65537 for a
circuit means use the PLE default (the PLE

default parameters entry may not use…
Integer32r/w
Constraints:
range: 0-65537
.1.3.6.1.2.1.10.5.9.1.19
x25CallParmCallingExt mandatory
The Calling Extension facility. This
contains one of the following:

A sequence of hex digits with the value to
be put in the facility. These digits will be
converted to binary by the agent and put in
the…
OctetStringr/w
Constraints:
range: 0-40
.1.3.6.1.2.1.10.5.9.1.20
x25CallParmCalledExt mandatory
The Called Extension facility. This
contains one of the following:

A sequence of hex digits with the value to
be put in the facility. These digits will be
converted to binary by the agent and put in
the…
OctetStringr/w
Constraints:
range: 0-40
.1.3.6.1.2.1.10.5.9.1.21
x25CallParmInMinThuPutCls mandatory
The minimum input throughput Class. A
value of 16 for a circuit means use the PLE
default (the PLE parameters entry may not
use this value). A value of 17 indicates no
facility requested.
Integer32r/w
Constraints:
range: 0-17
.1.3.6.1.2.1.10.5.9.1.22
x25CallParmOutMinThuPutCls mandatory
The minimum output throughput Class. A
value of 16 for a circuit means use the PLE
default (the PLE parameters entry may not
use this value). A value of 17 indicates no
facility requested.
Integer32r/w
Constraints:
range: 0-17
.1.3.6.1.2.1.10.5.9.1.23
x25CallParmEndTrnsDly mandatory
The End-to-End Transit Delay to negotiate.
An octet string of length 2, 4, or 6

contains the facility encoded as specified
in ISO/IEC 8208 section 15.3.2.4. An octet
string of length 3 containing the thr…
OctetStringr/w
Constraints:
range: 0-6
.1.3.6.1.2.1.10.5.9.1.24
x25CallParmPriority mandatory
The priority facility to negotiate. The
octet string encoded as specified in ISO/IEC
8208 section 15.3.2.5. A zero length string
indicates no facility requested. The entry
for the PLE default parameters must be zero
OctetStringr/w
Constraints:
range: 0-6
.1.3.6.1.2.1.10.5.9.1.25
x25CallParmProtection mandatory
A string contains the following:
A hex string containing the value for the
protection facility. This will be converted
from hex to the octets actually in the
packet by the agent. The agent will supply
the length field…
OctetStringr/w
Constraints:
range: 0-108
.1.3.6.1.2.1.10.5.9.1.26
x25CallParmExptData mandatory
The Expedited Data facility to negotiate.
A value of default for a circuit means use
the PLE default value. The entry for the
PLE default parameters may not have the
value default.
Enumerationr/w
Enumerated Values:
1default
2noExpeditedData
3expeditedData
.1.3.6.1.2.1.10.5.9.1.27
x25CallParmUserData mandatory
The call user data as placed in the packet.
A zero length string indicates no call user
data. If both the circuit call parameters
and the PLE default have call user data
defined, the data from the circuit call
paramete…
OctetStringr/w
Constraints:
range: 0-128
.1.3.6.1.2.1.10.5.9.1.28
x25CallParmCallingNetworkFacilities mandatory
The calling network facilities. The
facilities are encoded here exactly as
encoded in the call packet. These

facilities do not include the marker
facility code.

A zero length string in th…
OctetStringr/w
Constraints:
range: 0-108
.1.3.6.1.2.1.10.5.9.1.29
x25CallParmCalledNetworkFacilities mandatory
The called network facilities. The
facilities are encoded here exactly as
encoded in the call packet. These
facilities do not include the marker
facility code.

A zero length string in the entry for the
OctetStringr/w
Constraints:
range: 0-108