x25CircuitStatus
RFC1382-MIB ·
.1.3.6.1.2.1.10.5.5.1.3
Object
column
mandatory
r/w
Enumeration
This object reports the current status of
the circuit.
An existing instance of this object can only
be set to startClear, startPvcResetting, or
invalid. An instance with the value calling
or open can only be set to startClear and
that action will start clearing the circuit.
An instance with the value PVC can only be
set to startPvcResetting or invalid and that
action resets the PVC or deletes the circuit
respectively. The values startClear or
startPvcResetting will never be returned by
an agent. An attempt to set the status of
an existing instance to a value other than
one of these values will result in an error.
A non-existing instance can be set to PVC to
create a PVC if the implementation supports
dynamic creation of PVCs. Some
implementations may only allow creation and
deletion of PVCs if the interface is down.
Since the instance identifier will supply
the PLE index and the channel number,
setting this object alone supplies
sufficient information to create the
instance. All the DEFVAL clauses for the
other objects of this table are appropriate
for creating a PVC; PLEs creating entries
for placed or accepted calls will use values
appropriate for the call rather than the
value of the DEFVAL clause. Two managers
trying to create the same PVC can determine
from the return code which manager succeeded
and which failed (the failing manager fails
because it can not set a value of PVC for an
existing object).
An entry in the closed or invalid state may
be deleted or reused at the agent's
convence. If the entry is kept in the
closed state, the values of the parameters
associated with the entry must be correct.
Closed implies the values in the circuit
table are correct.
The value of invalid indicates the other
values in the table are invalid. Many
agents may never return a value of invalid
because they dynamically allocate and free
unused table entries. An agent for a
statically configured systems can return
invalid to indicate the entry has not yet
been used so the counters contain no
information.
Context
- MIB
- RFC1382-MIB
- OID
.1.3.6.1.2.1.10.5.5.1.3- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- x25CircuitEntry
- Table
- x25CircuitTable
- Siblings
- 20
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | invalid |
2 | closed |
3 | calling |
4 | open |
5 | clearing |
6 | pvc |
7 | pvcResetting |
8 | startClear |
9 | startPvcResetting |
10 | other |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| x25CircuitIndex mandatory The ifIndex value for the X.25 Interface. | column | RFC1381-MIBIfIndexType | .1.3.6.1.2.1.10.5.5.1.1 |
| x25CircuitInInterrupts mandatory The number of interrupt packets received
for this circuit. | column | RFC1155-SMICounter | .1.3.6.1.2.1.10.5.5.1.10 |
| x25CircuitOutOctets mandatory The number of octets of user data sent for
this circuit. | column | RFC1155-SMICounter | .1.3.6.1.2.1.10.5.5.1.11 |
| x25CircuitOutPdus mandatory The number of PDUs sent for this circuit. | column | RFC1155-SMICounter | .1.3.6.1.2.1.10.5.5.1.12 |
| x25CircuitOutInterrupts mandatory The number of interrupt packets sent on
this circuit. | column | RFC1155-SMICounter | .1.3.6.1.2.1.10.5.5.1.13 |
| x25CircuitDataRetransmissionTimeouts mandatory The number of times the T25 data
retransmission timer expired for this
circuit. | column | RFC1155-SMICounter | .1.3.6.1.2.1.10.5.5.1.14 |
| x25CircuitResetTimeouts mandatory The number of times the T22 reset timer
expired for this circuit. | column | RFC1155-SMICounter | .1.3.6.1.2.1.10.5.5.1.15 |
| x25CircuitInterruptTimeouts mandatory The number of times the T26 Interrupt timer
expired for this circuit. | column | RFC1155-SMICounter | .1.3.6.1.2.1.10.5.5.1.16 |
| x25CircuitCallParamId mandatory This identifies the instance of the
x25CallParmIndex for the entry in the
x25CallParmTable which contains the call
parameters in use with this circuit. The
entry referenced must … | column | ObjectIdentifier | .1.3.6.1.2.1.10.5.5.1.17 |
| x25CircuitCalledDteAddress mandatory For incoming calls, this is the called
address from the call indication packet.
For outgoing calls, this is the called
address from the call confirmation packet.
Th… | column | X121Address | .1.3.6.1.2.1.10.5.5.1.18 |
| x25CircuitCallingDteAddress mandatory For incoming calls, this is the calling
address from the call indication packet.
For outgoing calls, this is the calling
address from the call confirmation packet.
This will be ze… | column | X121Address | .1.3.6.1.2.1.10.5.5.1.19 |
| x25CircuitChannel mandatory The channel number for this circuit. | column | Integer32 | .1.3.6.1.2.1.10.5.5.1.2 |
| x25CircuitOriginallyCalledAddress mandatory For incoming calls, this is the address in
the call Redirection or Call Deflection
Notification facility if the call was
deflected or redirected, otherwise it will
be called addre… | column | X121Address | .1.3.6.1.2.1.10.5.5.1.20 |
| x25CircuitDescr mandatory A descriptive string associated with this
circuit. This provides a place for the
agent to supply any descriptive information
it knows about the use or owner of the
circuit. The … | column | OctetString | .1.3.6.1.2.1.10.5.5.1.21 |
| x25CircuitEstablishTime mandatory The value of sysUpTime when the channel was
associated with this circuit. For outgoing
SVCs, this is the time the first call packet
was sent. For incoming SVCs, this is the
time… | column | RFC1155-SMITimeTicks | .1.3.6.1.2.1.10.5.5.1.4 |
| x25CircuitDirection mandatory The direction of the call that established
this circuit. | column | Enumeration | .1.3.6.1.2.1.10.5.5.1.5 |
| x25CircuitInOctets mandatory The number of octets of user data delivered
to upper layer. | column | RFC1155-SMICounter | .1.3.6.1.2.1.10.5.5.1.6 |
| x25CircuitInPdus mandatory The number of PDUs received for this
circuit. | column | RFC1155-SMICounter | .1.3.6.1.2.1.10.5.5.1.7 |
| x25CircuitInRemotelyInitiatedResets mandatory The number of Resets received for this
circuit with cause code of DTE initiated. | column | RFC1155-SMICounter | .1.3.6.1.2.1.10.5.5.1.8 |
| x25CircuitInProviderInitiatedResets mandatory The number of Resets received for this
circuit with cause code other than DTE
initiated. | column | RFC1155-SMICounter | .1.3.6.1.2.1.10.5.5.1.9 |