PowerNet-Inova Table View

Table-centric layout grouping table, row, and column objects.

Tables
28
Rows
28
Columns
252

rPDU2IdentTable

table mandatory
.1.3.6.1.4.1.63131.1.1.26.2 · 1 row entry · 13 columns
A table of Rack PDU identification data
rPDU2IdentEntry entry .1.3.6.1.4.1.63131.1.1.26.2.1
Identification data from Rack PDU being queried
Indexes
No indexes recorded
Column Syntax OID
rPDU2IdentIndex mandatory
The index to the Rack PDU identification table
entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.2.1.1
rPDU2IdentModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.2.1.2
rPDU2IdentName mandatory
A user-defined string identifying the Rack PDU
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.2.1.3
rPDU2IdentLocation mandatory
A user-defined string identifying the location
of the Rack PDU
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.2.1.4
rPDU2IdentHardwareRev mandatory
The Rack PDU hardware version
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.2.1.5
rPDU2IdentFirmwareRev mandatory
The Rack PDU firmware version
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.2.1.6
rPDU2IdentDateOfManufacture mandatory
The date the Rack PDU was manufactured
in mm/dd/yyyy format
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.2.1.7
rPDU2IdentModelNumber mandatory
The Rack PDU model number
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.2.1.8
rPDU2IdentSerialNumber mandatory
The Rack PDU serial number
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.2.1.9
rPDU2IdentContact mandatory
A user-defined string identifying the
person to contact regarding the Rack PDU
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.2.1.10
rPDU2IdentBootMonitorRev mandatory
The Rack PDU Boot Monitor version
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.2.1.11
rPDU2IdentLongDescription mandatory
The Rack PDU Long Description name
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.2.1.12
rPDU2IdentNMCSerialNumber mandatory
The Rack PDU Network Management Card (NMC) serial number
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.2.1.13

rPDU2DeviceConfigTable

table mandatory
.1.3.6.1.4.1.63131.1.1.26.4.1 · 1 row entry · 14 columns
A table of Rack PDU configuration data
rPDU2DeviceConfigEntry entry .1.3.6.1.4.1.63131.1.1.26.4.1.1
Configuration data from Rack PDU being queried
Indexes
No indexes recorded
Column Syntax OID
rPDU2DeviceConfigIndex mandatory
The index to the Rack PDU table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.1.1.1
rPDU2DeviceConfigModule mandatory
The user-defined Rack PDU numeric ID
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.1.1.2
rPDU2DeviceConfigName mandatory
A user-defined string identifying the Rack PDU
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.4.1.1.3
rPDU2DeviceConfigLocation mandatory
A user-defined string identifying the location
of the Rack PDU
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.4.1.1.4
rPDU2DeviceConfigDisplayOrientation mandatory
Indicates the intended physical orientation
of the display.

displayNormal(1) indicates normal orientation
displayReverse(2) indicates upside down orientation
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.4.1.1.5
rPDU2DeviceConfigColdstartDelay mandatory
The amount of delay, measured in seconds, between
when power is provided to the Rack PDU and when
the Rack PDU provides basic master power to the
outlets.
Allowed values are:
-1 - never apply power automatically.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.1.1.6
rPDU2DeviceConfigLowLoadPowerThreshold mandatory
User-defined low power draw alarm threshold,
measured in tenths of kilowatts. Models that do
not support this feature will respond to this OID
with a value of -1.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.1.1.7
rPDU2DeviceConfigNearOverloadPowerThreshold mandatory
User-defined near power overload threshold,
measured in tenths of kilowatts. Models that do
not support this feature will respond to this OID
with a value of -1.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.1.1.8
rPDU2DeviceConfigOverloadPowerThreshold mandatory
User-defined power overload threshold,
measured in tenths of kilowatts. Models that do
not support this feature will respond to this OID
with a value of -1.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.1.1.9
rPDU2DeviceConfigDevicePeakPowerReset mandatory
Setting this OID to reset (2) will cause the existing peak power value
to be replaced by the current load power value.

Getting this OID will do nothing and return the noOperation(1) value.
Models that do …
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.4.1.1.10
rPDU2DeviceConfigDeviceEnergyReset mandatory
Setting this OID to reset (2) will cause the device energy meter value
to be reset to zero.

Getting this OID in models that support this feature will do nothing
and return the noOperation(1) value.
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.4.1.1.11
rPDU2DeviceConfigOutletsEnergyReset mandatory
Setting this OID to reset (2) will cause the all outlet energy meter values
to be reset to zero.

Getting this OID will do nothing and return the noOperation(1) value.

Models that do not sup…
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.4.1.1.12
rPDU2DeviceConfigOutletsPeakLoadReset mandatory
Setting this OID to reset (2) will cause the all outlet peak load values
to be reset to zero.

Getting this OID will do nothing and return the noOperation(1) value.

Models that do not suppor…
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.4.1.1.13
rPDU2DeviceConfigContact mandatory
A user-defined string identifying the
person to contact regarding the Rack PDU
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.4.1.1.14
.1.3.6.1.4.1.63131.1.1.26.4.2 · 1 row entry · 13 columns
A table of Rack PDU properties
rPDU2DevicePropertiesEntry entry .1.3.6.1.4.1.63131.1.1.26.4.2.1
Properties of the Rack PDU being queried
Indexes
No indexes recorded
Column Syntax OID
rPDU2DevicePropertiesIndex mandatory
The index to the Rack PDU properties table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.2.1.1
rPDU2DevicePropertiesModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.2.1.2
rPDU2DevicePropertiesName mandatory
A user-defined string identifying the Rack PDU
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.4.2.1.3
rPDU2DevicePropertiesNumOutlets mandatory
The number of outlets on the Rack PDU
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.2.1.4
rPDU2DevicePropertiesNumSwitchedOutlets mandatory
The number of switched outlets on the Rack PDU
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.2.1.5
rPDU2DevicePropertiesNumMeteredOutlets mandatory
The number of metered outlets on the Rack PDU
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.2.1.6
rPDU2DevicePropertiesNumPhases mandatory
The number of phases present in the Rack PDU
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.2.1.7
rPDU2DevicePropertiesNumMeteredBanks mandatory
The number of metered banks present in the Rack PDU
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.2.1.8
rPDU2DevicePropertiesMaxCurrentRating mandatory
The maximum current rating, measured in Amps, for
the Rack PDU
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.2.1.9
rPDU2DevicePropertiesOrientation mandatory
Rack PDU orientation
Enumeration .1.3.6.1.4.1.63131.1.1.26.4.2.1.10
rPDU2DevicePropertiesOutletLayout mandatory
Getting this OID will return outlet layout for the device.

seqPhaseToNeutral(1) indicates outlet layout as follows:
1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...
or for single phase SKUs, all outlets 1-N
Enumeration .1.3.6.1.4.1.63131.1.1.26.4.2.1.11
rPDU2DevicePropertiesMaxPhaseCurrentRating mandatory
The maximum current rating, measured in Amps, for
the Rack PDU
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.2.1.12
rPDU2DevicePropertiesDevicePowerRating mandatory
The maximum power rating, measured in tenths of kilowatts, for
the Rack PDU
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.2.1.13

rPDU2DeviceStatusTable

table mandatory
.1.3.6.1.4.1.63131.1.1.26.4.3 · 1 row entry · 20 columns
A table of Rack PDU status information
rPDU2DeviceStatusEntry entry .1.3.6.1.4.1.63131.1.1.26.4.3.1
Status information from the Rack PDU being queried
Indexes
No indexes recorded
Column Syntax OID
rPDU2DeviceStatusIndex mandatory
The index to the Rack PDU status table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.3.1.1
rPDU2DeviceStatusModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.3.1.2
rPDU2DeviceStatusName mandatory
A user-defined string identifying the Rack PDU
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.4.3.1.3
rPDU2DeviceStatusLoadState mandatory
Indicates the present load status of the Rack PDU.
Models that do not support this feature will respond to this OID
with a value of notsupported (5).
Enumeration .1.3.6.1.4.1.63131.1.1.26.4.3.1.4
rPDU2DeviceStatusPower mandatory
The power consumption of the Rack PDU load in hundredths of kilowatts.
Models that do not support this feature will respond to this OID
with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.3.1.5
rPDU2DeviceStatusPeakPower mandatory
The peak power consumption of the Rack PDU load in hundredths of kilowatts.
Models that do not support this feature will respond to this OID with a value
of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.3.1.6
rPDU2DeviceStatusPeakPowerTimestamp mandatory
Indicates the date and time that peak power consumption occurred.
Models that do not support this feature will respond to this OID with string
'notsupported'.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.4.3.1.7
rPDU2DeviceStatusPeakPowerStartTime mandatory
Indicates the date and time of the last device peak power reset.
Models that do not support this feature will respond to this OID with string
'notsupported'.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.4.3.1.8
rPDU2DeviceStatusEnergy mandatory
A user resettable energy meter measuring Rack PDU load
energy consumption in tenths of kilowatt-hours. Models that do not
support this feature will respond to this OID
with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.3.1.9
rPDU2DeviceStatusEnergyStartTime mandatory
Indicates the date and time of the last device energy
meter reset. Models that do not support this feature will
respond to this OID with string 'notsupported'.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.4.3.1.10
rPDU2DeviceStatusCommandPending mandatory
Indicates whether or not the device
is processing a pending command. If
the commandPendingUnknown (3) value is
returned, all devices powered by the
Rack PDU should be shut down. The
Rack PDU's power should then be cyc…
Enumeration .1.3.6.1.4.1.63131.1.1.26.4.3.1.11
rPDU2DeviceStatusPowerSupplyAlarm mandatory
Indicates a power supply alarm is active when value
equals alarm (2)
Enumeration .1.3.6.1.4.1.63131.1.1.26.4.3.1.12
rPDU2DeviceStatusPowerSupply1Status mandatory
Indicates whether or not an alarm is active in Power
Supply 1
Enumeration .1.3.6.1.4.1.63131.1.1.26.4.3.1.13
rPDU2DeviceStatusPowerSupply2Status mandatory
Indicates whether or not an alarm is active in Power
Supply 2
Enumeration .1.3.6.1.4.1.63131.1.1.26.4.3.1.14
rPDU2DeviceStatusOutletsEnergyStartTime mandatory
Indicates the date and time of the last outlets energy
meter reset. Models that do not support this feature will
respond to this OID with string 'notsupported'.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.4.3.1.15
rPDU2DeviceStatusApparentPower mandatory
The apparent power consumption of the Rack PDU load in hundredths of kiloVoltAmps (kVA).
Models that do not support this feature will respond to this OID
with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.3.1.16
rPDU2DeviceStatusPowerFactor mandatory
The power factor of the Rack PDU load in hundredths. Models that do not support this feature
will respond to this OID with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.3.1.17
rPDU2DeviceStatusNPSType mandatory
The device NPS status:
notNPS (1) indicates the Rack PDU is not in an NPS group.
host (2) indicates the Rack PDU has been designated as a host in an NPS group.
Only one Rack PDU in an NPS group is allowed to be the ho…
Enumeration .1.3.6.1.4.1.63131.1.1.26.4.3.1.18
rPDU2DeviceStatusResidualPower mandatory
The measured device residual power from the PDU meters in hundredths of kiloVoltAmps.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.3.1.19
rPDU2DeviceStatusFrequency mandatory
The measured device frequency from the PDU meters in tenths of Hz.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.3.1.20
.1.3.6.1.4.1.63131.1.1.26.4.4 · 1 row entry · 4 columns
A table of Rack PDU control data
rPDU2DeviceControlEntry entry .1.3.6.1.4.1.63131.1.1.26.4.4.1
Control data from Rack PDU being queried
Indexes
No indexes recorded
Column Syntax OID
rPDU2DeviceControlIndex mandatory
The index to the Rack PDU control table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.4.1.1
rPDU2DeviceControlModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.4.4.1.2
rPDU2DeviceControlName mandatory
A user-defined string identifying the Rack PDU
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.4.4.1.3
rPDU2DeviceControlCommand mandatory
Setting this OID to immediateAllOn (1) will turn all outlets
on immediately.

Setting this OID to delayedAllOn (2) will turn all outlets on as
defined by each outlet's rPDU2OutletSwitchedConfigPowerOnTime
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.4.4.1.4

rPDU2PhaseConfigTable

table mandatory
.1.3.6.1.4.1.63131.1.1.26.6.1 · 1 row entry · 8 columns
A table of Rack PDU phase configuration data
rPDU2PhaseConfigEntry entry .1.3.6.1.4.1.63131.1.1.26.6.1.1
Configuration data from currently queried Rack
PDU phase
Indexes
No indexes recorded
Column Syntax OID
rPDU2PhaseConfigIndex mandatory
The index to the Rack PDU phase configuration
table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.1.1.1
rPDU2PhaseConfigModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.1.1.2
rPDU2PhaseConfigNumber mandatory
The numeric phase ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.1.1.3
rPDU2PhaseConfigOverloadRestriction mandatory
This OID controls the behavior of a Switched Rack PDU
phase when an overload condition is possible and
additional outlets are requested to be turned on.

Setting this OID to alwaysAllowTurnON (1) will alwa…
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.6.1.1.4
rPDU2PhaseConfigLowLoadCurrentThreshold mandatory
User-defined low load phase current
threshold in Amps
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.1.1.5
rPDU2PhaseConfigNearOverloadCurrentThreshold mandatory
User-defined near phase overload warning
threshold in Amps
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.1.1.6
rPDU2PhaseConfigOverloadCurrentThreshold mandatory
User-defined phase overload current
threshold in Amps
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.1.1.7
rPDU2PhaseConfigPhasePeakCurrentReset mandatory
Setting this OID to reset (2) will cause the existing peak current value
to be replaced by the present load current value.

Getting this OID will do nothing and return the noOperation(1) value.
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.6.1.1.8
.1.3.6.1.4.1.63131.1.1.26.6.2 · 1 row entry · 3 columns
A table of Rack PDU phase properties
rPDU2PhasePropertiesEntry entry .1.3.6.1.4.1.63131.1.1.26.6.2.1
Properties of the currently queried Rack
PDU phase
Indexes
No indexes recorded
Column Syntax OID
rPDU2PhasePropertiesIndex mandatory
The index to the Rack PDU phase properties
table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.2.1.1
rPDU2PhasePropertiesModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.2.1.2
rPDU2PhasePropertiesNumber mandatory
The numeric phase ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.2.1.3

rPDU2PhaseStatusTable

table mandatory
.1.3.6.1.4.1.63131.1.1.26.6.3 · 1 row entry · 14 columns
A table of Rack PDU phase status data
rPDU2PhaseStatusEntry entry .1.3.6.1.4.1.63131.1.1.26.6.3.1
Status data from currently queried Rack PDU
phase
Indexes
No indexes recorded
Column Syntax OID
rPDU2PhaseStatusIndex mandatory
The index to the Rack PDU phase status table
entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.3.1.1
rPDU2PhaseStatusModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.3.1.2
rPDU2PhaseStatusNumber mandatory
The numeric phase ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.3.1.3
rPDU2PhaseStatusLoadState mandatory
Indicates the present load status of the Rack PDU
phase being queried
Enumeration .1.3.6.1.4.1.63131.1.1.26.6.3.1.4
rPDU2PhaseStatusCurrent mandatory
Indicates the current draw, in tenths of Amps, of the load
on the Rack PDU phase being queried
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.3.1.5
rPDU2PhaseStatusVoltage mandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase being queried. Models that do not support this
feature will respond to this OID with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.3.1.6
rPDU2PhaseStatusPower mandatory
Indicates the load power, in hundredths of kilowatts (kW),
consumed on the Rack PDU phase being queried.
Models that do not support this feature will respond to this
OID with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.3.1.7
rPDU2PhaseStatusApparentPower mandatory
Indicates the load apparent power, in hundredths of kiloVoltAmps (kVA),
consumed on the Rack PDU phase being queried.
Models that do not support this feature will respond to this
OID with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.3.1.8
rPDU2PhaseStatusPowerFactor mandatory
Indicates the load power factor, in hundredths,
of the Rack PDU phase being queried.
Models that do not support this feature will respond to
this OID with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.3.1.9
rPDU2PhaseStatusPeakCurrent mandatory
The peak current of the Rack PDU phase load in tenths of Amps
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.3.1.10
rPDU2PhaseStatusPeakCurrentTimestamp mandatory
Indicates the date and time that the peak current occurred
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.6.3.1.11
rPDU2PhaseStatusPeakCurrentStartTime mandatory
Indicates the date and time of the last phase peak current reset
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.6.3.1.12
rPDU2PhaseStatusEnergy mandatory
A user resettable energy meter measuring Rack PDU phase load
energy consumption in tenths of kilowatt-hours. Models that do not
support this feature will respond to this OID
with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.6.3.1.13
rPDU2PhaseStatusBreaker mandatory
Phase breaker status.
Enumeration .1.3.6.1.4.1.63131.1.1.26.6.3.1.14

rPDU2BankConfigTable

table mandatory
.1.3.6.1.4.1.63131.1.1.26.8.1 · 1 row entry · 8 columns
A table of Rack PDU bank configuration data
rPDU2BankConfigEntry entry .1.3.6.1.4.1.63131.1.1.26.8.1.1
Configuration data from currently queried
Rack PDU bank
Indexes
No indexes recorded
Column Syntax OID
rPDU2BankConfigIndex mandatory
The index to the Rack PDU bank configuration
table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.1.1.1
rPDU2BankConfigModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.1.1.2
rPDU2BankConfigNumber mandatory
The numeric bank ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.1.1.3
rPDU2BankConfigOverloadRestriction mandatory
This OID controls the behavior of a Switched Rack PDU
bank when an overload condition is possible and
additional outlets are requested to be turned on.

Setting this OID to alwaysAllowTurnON (1) will alway…
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.8.1.1.4
rPDU2BankConfigLowLoadCurrentThreshold mandatory
User-defined low load bank current
threshold in Amps
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.1.1.5
rPDU2BankConfigNearOverloadCurrentThreshold mandatory
User-defined near bank overload current warning
threshold in Amps
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.1.1.6
rPDU2BankConfigOverloadCurrentThreshold mandatory
User-defined bank overload current threshold
in Amps
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.1.1.7
rPDU2BankConfigBankPeakCurrentReset mandatory
Setting this OID to reset (2) will cause the existing peak current value
to be replaced by the present load current value.

Getting this OID will do nothing and return the noOperation(1) value.
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.8.1.1.8
.1.3.6.1.4.1.63131.1.1.26.8.2 · 1 row entry · 5 columns
A table of Rack PDU bank properties
rPDU2BankPropertiesEntry entry .1.3.6.1.4.1.63131.1.1.26.8.2.1
Properties of the currently queried
Rack PDU bank
Indexes
No indexes recorded
Column Syntax OID
rPDU2BankPropertiesIndex mandatory
The index to the Rack PDU bank properties
table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.2.1.1
rPDU2BankPropertiesModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.2.1.2
rPDU2BankPropertiesNumber mandatory
The numeric bank ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.2.1.3
rPDU2BankPropertiesPhaseLayout mandatory
This OID describes the outlet phase connections on
the referenced bank as follows:

seqPhase1ToNeutral(1) indicates that bank outlets are
wired from Phase 1 to Neutral.

seqPhase2ToNeutral(2)…
Rpdu2OutletPhaseLayoutType
Textual Convention: Rpdu2OutletPhaseLayoutType Enumeration
Type Values:
1seqPhase1ToNeutral
2seqPhase2ToNeutral
3seqPhase3ToNeutral
4seqPhase1ToPhase2
5seqPhase2ToPhase3
6seqPhase3ToPhase1
.1.3.6.1.4.1.63131.1.1.26.8.2.1.4
rPDU2BankPropertiesBreakerRating mandatory
If bank circuit breakers are present on the device, this OID will return
the rating of the breaker in Amps.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.2.1.5

rPDU2BankStatusTable

table mandatory
.1.3.6.1.4.1.63131.1.1.26.8.3 · 1 row entry · 11 columns
A table of Rack PDU bank status data
rPDU2BankStatusEntry entry .1.3.6.1.4.1.63131.1.1.26.8.3.1
Status data from currently queried Rack PDU
bank
Indexes
No indexes recorded
Column Syntax OID
rPDU2BankStatusIndex mandatory
The index to the Rack PDU bank status
table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.3.1.1
rPDU2BankStatusModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.3.1.2
rPDU2BankStatusNumber mandatory
The numeric bank ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.3.1.3
rPDU2BankStatusLoadState mandatory
Indicates the present load status of the Rack PDU
bank being queried
Enumeration .1.3.6.1.4.1.63131.1.1.26.8.3.1.4
rPDU2BankStatusCurrent mandatory
Indicates the current draw, in tenths of Amps, of the load
on the Rack PDU bank being queried
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.3.1.5
rPDU2BankStatusPeakCurrent mandatory
The peak current of the Rack PDU bank load in tenths of Amps
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.3.1.6
rPDU2BankStatusPeakCurrentTimestamp mandatory
Indicates the date and time the bank peak current occurred
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.8.3.1.7
rPDU2BankStatusPeakCurrentStartTime mandatory
Indicates the date and time of the last bank peak current reset
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.8.3.1.8
rPDU2BankStatusVoltage mandatory
Indicates the Voltage, in Volts, of the Rack PDU bank being queried.
Models that do not support this feature will respond to this OID
with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.3.1.9
rPDU2BankStatusPower mandatory
Indicates the load power, in hundredths of kilowatts (kW),
consumed on the RackPDU phase being queried.
Models that do not support this feature will respond to this OID
with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.3.1.10
rPDU2BankStatusEnergy mandatory
A user resettable energy meter measuring Rack PDU phase load
energy consumption in tenths of kilowatt-hours.
Models that do not support this feature will respond to this OID
with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.8.3.1.11
.1.3.6.1.4.1.63131.1.1.26.9.2.1 · 1 row entry · 8 columns
A table of Rack PDU switched outlet configuration data
rPDU2OutletSwitchedConfigEntry entry .1.3.6.1.4.1.63131.1.1.26.9.2.1.1
Configuration data from currently queried
Rack PDU switched outlet
Indexes
No indexes recorded
Column Syntax OID
rPDU2OutletSwitchedConfigIndex mandatory
The index to the Rack PDU switched outlet
configuration table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.1
rPDU2OutletSwitchedConfigModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.2
rPDU2OutletSwitchedConfigName mandatory
The user-defined switched outlet ID string
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.3
rPDU2OutletSwitchedConfigNumber mandatory
The numeric switched outlet ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.4
rPDU2OutletSwitchedConfigPowerOnTime mandatory
The amount of delay, in seconds, between when
power is provided to the Rack PDU and when
this switched outlet starts providing power.
Range -1...7200 where -1 = Never power on,
0 = immediate power on, and 1-7200 = secon…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.5
rPDU2OutletSwitchedConfigPowerOffTime mandatory
The amount of time, in seconds, this outlet will
delay powering off.
Range -1...7200 where -1 = Never power off,
0 = immediate power off, and 1-7200 = seconds to
delay.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.6
rPDU2OutletSwitchedConfigRebootDuration mandatory
After turning power off during a reboot sequence,
the amount of time to wait before turning power
to this outlet back on.
Range 5-60 seconds delay.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.7
rPDU2OutletSwitchedConfigExternalLink mandatory
User-defined external device web link.
Possible use cases could be the IP address of the external device
plugged into the outlet or its manufacturer web page for convenient
support such as user manuals, specifications…
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.8
.1.3.6.1.4.1.63131.1.1.26.9.2.2 · 1 row entry · 6 columns
A table of Rack PDU switched outlet properties
rPDU2OutletSwitchedPropertiesEntry entry .1.3.6.1.4.1.63131.1.1.26.9.2.2.1
Properties of the currently queried Rack PDU
switched outlet
Indexes
No indexes recorded
Column Syntax OID
rPDU2OutletSwitchedPropertiesIndex mandatory
The index to the Rack PDU switched outlet
properties table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.1
rPDU2OutletSwitchedPropertiesModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.2
rPDU2OutletSwitchedPropertiesName mandatory
The user-defined switched outlet ID string
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.3
rPDU2OutletSwitchedPropertiesNumber mandatory
The numeric switched outlet ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.4
rPDU2OutletSwitchedPropertiesPhaseLayout mandatory
This OID describes the phase connections of
the referenced outlet as follows:

seqPhase1ToNeutral(1) indicates that the outlet is
wired from Phase 1 to Neutral.

seqPhase2ToNeutral(2) indicat…
Rpdu2OutletPhaseLayoutType
Textual Convention: Rpdu2OutletPhaseLayoutType Enumeration
Type Values:
1seqPhase1ToNeutral
2seqPhase2ToNeutral
3seqPhase3ToNeutral
4seqPhase1ToPhase2
5seqPhase2ToPhase3
6seqPhase3ToPhase1
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.5
rPDU2OutletSwitchedPropertiesBank mandatory
The numeric bank ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.6
.1.3.6.1.4.1.63131.1.1.26.9.2.3 · 1 row entry · 7 columns
A table of Rack PDU switched outlet status
information
rPDU2OutletSwitchedStatusEntry entry .1.3.6.1.4.1.63131.1.1.26.9.2.3.1
Status information for currently queried
Rack PDU switched outlet
Indexes
No indexes recorded
Column Syntax OID
rPDU2OutletSwitchedStatusIndex mandatory
The index to the Rack PDU switched outlet
status information table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.3.1.1
rPDU2OutletSwitchedStatusModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.3.1.2
rPDU2OutletSwitchedStatusName mandatory
The user-defined switched outlet ID string
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.9.2.3.1.3
rPDU2OutletSwitchedStatusNumber mandatory
The numeric switched outlet ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.3.1.4
rPDU2OutletSwitchedStatusState mandatory
Indicates the present switch state of the Rack
PDU switched outlet being queried
Enumeration .1.3.6.1.4.1.63131.1.1.26.9.2.3.1.5
rPDU2OutletSwitchedStatusCommandPending mandatory
Indicates whether or not the device is
processing a command for this outlet.

If the commandPendingUnknown (3) value is
returned, all devices powered by the Rack PDU
should be shut down. The Rack PDU's po…
Enumeration .1.3.6.1.4.1.63131.1.1.26.9.2.3.1.6
rPDU2OutletSwitchedStatusExternalLink mandatory
Each RPDU outlet can have its own external web URL link.
This can be configured in the rPDU2OutletSwitchedConfigExternalLink OID.
When this link is clicked in the web interface, the linked URL will
open in the web b…
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.9.2.3.1.7
.1.3.6.1.4.1.63131.1.1.26.9.2.4 · 1 row entry · 5 columns
A table of Rack PDU switched outlet control
data
rPDU2OutletSwitchedControlEntry entry .1.3.6.1.4.1.63131.1.1.26.9.2.4.1
Control data for currently queried Rack
PDU switched outlet
Indexes
BLADE-MIBbladecKVMVpdIndex
Column Syntax OID
rPDU2OutletSwitchedControlIndex mandatory
The index to the Rack PDU switched outlet
control data table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.4.1.1
rPDU2OutletSwitchedControlModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.4.1.2
rPDU2OutletSwitchedControlName mandatory
The user-defined switched outlet ID string
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.9.2.4.1.3
rPDU2OutletSwitchedControlNumber mandatory
The numeric switched outlet ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.2.4.1.4
rPDU2OutletSwitchedControlCommand mandatory
Getting this variable will return the outlet state. If
the outlet is on, the immediateOn (1) value will be returned.
If the outlet is off, the immediateOff (2) value will be
returned. If the state of the outlet cannot b…
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.9.2.4.1.5
.1.3.6.1.4.1.63131.1.1.26.9.4.1 · 1 row entry · 8 columns
A table of Rack PDU metered outlet configuration data
rPDU2OutletMeteredConfigEntry entry .1.3.6.1.4.1.63131.1.1.26.9.4.1.1
Configuration data from currently queried
Rack PDU metered outlet
Indexes
No indexes recorded
Column Syntax OID
rPDU2OutletMeteredConfigIndex mandatory
The index to the Rack PDU metered outlet
configuration table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.1
rPDU2OutletMeteredConfigModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.2
rPDU2OutletMeteredConfigName mandatory
The user-defined metered outlet ID string
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.3
rPDU2OutletMeteredConfigNumber mandatory
The numeric switched outlet ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.4
rPDU2OutletMeteredConfigLowLoadCurrentThreshold mandatory
User-defined low load outlet current threshold in in tenths of Amps
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.5
rPDU2OutletMeteredConfigNearOverloadCurrentThreshold mandatory
User-defined near outlet overload warning threshold
in in tenths of Amps
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.6
rPDU2OutletMeteredConfigOverloadCurrentThreshold mandatory
User-defined outlet overload current threshold in in tenths of Amps
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.7
rPDU2OutletMeteredConfigExternalLink mandatory
User-defined external device web link.
Possible use cases could be the IP address of the external device
plugged into the outlet or its manufacturer web page for convenient
support such as user manuals, specifications…
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.8
.1.3.6.1.4.1.63131.1.1.26.9.4.2 · 1 row entry · 7 columns
A table of Rack PDU metered outlet properties
rPDU2OutletMeteredPropertiesEntry entry .1.3.6.1.4.1.63131.1.1.26.9.4.2.1
Properties of currently queried Rack PDU
metered outlet
Indexes
No indexes recorded
Column Syntax OID
rPDU2OutletMeteredPropertiesIndex mandatory
The index to the Rack PDU metered properties table
entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.1
rPDU2OutletMeteredPropertiesModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.2
rPDU2OutletMeteredPropertiesName mandatory
The user-defined metered outlet ID string
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.3
rPDU2OutletMeteredPropertiesNumber mandatory
The numeric metered outlet ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.4
rPDU2OutletMeteredPropertiesLayout mandatory
This OID describes the phase connections of
the referenced outlet as follows:

seqPhase1ToNeutral(1) indicates that the outlet is
wired from Phase 1 to Neutral.

seqPhase2ToNeutral(2) indicat…
Rpdu2OutletPhaseLayoutType
Textual Convention: Rpdu2OutletPhaseLayoutType Enumeration
Type Values:
1seqPhase1ToNeutral
2seqPhase2ToNeutral
3seqPhase3ToNeutral
4seqPhase1ToPhase2
5seqPhase2ToPhase3
6seqPhase3ToPhase1
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.5
rPDU2OutletMeteredPropertiesPowerRating mandatory
Maximum power rating of Rack PDU metered outlet
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.6
rPDU2OutletMeteredPropertiesBank mandatory
This outlet's numeric bank ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.7
.1.3.6.1.4.1.63131.1.1.26.9.4.3 · 1 row entry · 16 columns
A table of Rack PDU metered outlet status data
rPDU2OutletMeteredStatusEntry entry .1.3.6.1.4.1.63131.1.1.26.9.4.3.1
Status data from currently queried Rack PDU
metered outlet
Indexes
No indexes recorded
Column Syntax OID
rPDU2OutletMeteredStatusIndex mandatory
The index to the Rack PDU metered status table
entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.1
rPDU2OutletMeteredStatusModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.2
rPDU2OutletMeteredStatusName mandatory
The user-defined metered outlet ID string
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.3
rPDU2OutletMeteredStatusNumber mandatory
The numeric metered outlet ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.4
rPDU2OutletMeteredStatusState mandatory
Indicates the present load status of the Rack
PDU metered outlet being queried
Enumeration .1.3.6.1.4.1.63131.1.1.26.9.4.3.1.5
rPDU2OutletMeteredStatusCurrent mandatory
Indicates the current draw, in tenths
of Amps, of the load on the Rack PDU
outlet being queried
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.6
rPDU2OutletMeteredStatusPower mandatory
Indicates the power draw of the load
on the Rack PDU outlet being queried
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.7
rPDU2OutletMeteredStatusPeakPower mandatory
Indicates the peak power load draw
on the Rack PDU outlet being queried
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.8
rPDU2OutletMeteredStatusPeakPowerTimestamp mandatory
Indicates the date and time that this metered
outlet's peak power consumption occurred
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.9
rPDU2OutletMeteredStatusPeakPowerStartTime mandatory
Indicates the start date and time that this metered
outlet began recording peak power observations
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.10
rPDU2OutletMeteredStatusEnergy mandatory
A user resettable energy meter measuring Rack PDU load
energy consumption in tenths of kilowatt-hours
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.11
rPDU2OutletMeteredStatusReceptacleType mandatory
Indicates receptacle type for the outlet.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.12
rPDU2OutletMeteredStatusExternalLink mandatory
Each RPDU outlet can have its own external web URL link.
This can be configured in the rPDU2OutletMeteredConfigExternalLink OID.
When this link is clicked in the web interface, the linked URL will
open in the web br…
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.13
rPDU2OutletMeteredStatusPowerFactor mandatory
The power factor of the Rack PDU outlet in hundredths. Models that do not support this feature
will respond to this OID with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.14
rPDU2OutletMeteredStatusApparentPower mandatory
The apparent power consumption of the Rack PDU outlet load in hundredths of kiloVoltAmps (kVA).
Models that do not support this feature will respond to this OID
with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.15
rPDU2OutletMeteredStatusVoltage mandatory
Indicates the Voltage, in Volts, of the Rack PDU outlet being queried.
Models that do not support this feature will respond to this OID
with a value of -1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.16
.1.3.6.1.4.1.63131.1.1.26.10.2.1 · 1 row entry · 16 columns
A table of temperature-humidity sensor
configuration data
rPDU2SensorTempHumidityConfigEntry entry .1.3.6.1.4.1.63131.1.1.26.10.2.1.1
Configuration data from temperature-humidity sensor
being queried
Indexes
No indexes recorded
Column Syntax OID
rPDU2SensorTempHumidityConfigIndex mandatory
The index to the temperature-humidity sensor
configuration data table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.1
rPDU2SensorTempHumidityConfigModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.2
rPDU2SensorTempHumidityConfigName mandatory
The user-defined temperature-humidity
sensor ID string
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.3
rPDU2SensorTempHumidityConfigNumber mandatory
The temperature-humidity sensor numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.4
rPDU2SensorTempHumidityConfigTemperatureAlarmEnable mandatory
Setting this OID enables or disables generation
of sensor temperature alarm.

Getting this OID returns the current value of
the temperature alarm enable.
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.10.2.1.1.5
rPDU2SensorTempHumidityConfigHumidityAlarmEnable mandatory
Setting this OID enables or disables generation
of sensor humidity alarm.

Getting this OID returns the current value of
the humidity alarm enable.
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.10.2.1.1.6
rPDU2SensorTempHumidityConfigTempMaxThreshF mandatory
Sensor maximum temperature alarm threshold in
Fahrenheit. Attempting to set this OID to a
value less than or equal to that of
rPDU2SensorTempHumidityConfigTempHighThreshF
will result in an error.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.7
rPDU2SensorTempHumidityConfigTempHighThreshF mandatory
Sensor high temperature warning alarm threshold
in Fahrenheit. Attempting to set this OID to a
value greater than or equal to that of
rPDU2SensorTempHumidityConfigTempMaxThreshF
will result in an error.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.8
rPDU2SensorTempHumidityConfigTempHysteresisF mandatory
Sensor temperature hysteresis setting in Fahrenheit
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.9
rPDU2SensorTempHumidityConfigTempMaxThreshC mandatory
Sensor maximum temperature alarm threshold
in Celsius. Attempting to set this OID to a
value less than or equal to that of
rPDU2SensorTempHumidityConfigTempHighThreshC
will result in an error.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.10
rPDU2SensorTempHumidityConfigTempHighThreshC mandatory
Sensor high temperature warning alarm threshold
in Celsius. Attempting to set this OID to a
value greater than or equal to that of
rPDU2SensorTempHumidityConfigTempMaxThreshC
will result in an error.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.11
rPDU2SensorTempHumidityConfigTempHysteresisC mandatory
Sensor temperature hysteresis setting in Celsius
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.12
rPDU2SensorTempHumidityConfigHumidityLowThresh mandatory
Sensor low humidity warning alarm threshold in percent
relative humidity. Attempting to set this OID to a
value less than or equal to that of
rPDU2SensorTempHumidityConfigHumidityMinThresh
will result in an error. Must …
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.13
rPDU2SensorTempHumidityConfigHumidityMinThresh mandatory
Sensor minimum humidity alarm threshold in percent
relative humidity. Attempting to set this OID to a
value greater than or equal to that of
rPDU2SensorTempHumidityConfigHumidityLowThresh
will result in an error. Must b…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.14
rPDU2SensorTempHumidityConfigHumidityHysteresis mandatory
Sensor humidity hysteresis setting in percent relative
humidity
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.15
rPDU2SensorTempHumidityConfigTempPeakReset mandatory
Setting this OID to reset (2) will cause the existing peak temperature
to be replaced by the present temperature reading.

Getting this OID will do nothing and return the noOperation(1) value.
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.10.2.1.1.16
.1.3.6.1.4.1.63131.1.1.26.10.2.2 · 1 row entry · 15 columns
A table of temperature-humidity sensor status data
rPDU2SensorTempHumidityStatusEntry entry .1.3.6.1.4.1.63131.1.1.26.10.2.2.1
Status information from temperature-humidity sensor
being queried
Indexes
No indexes recorded
Column Syntax OID
rPDU2SensorTempHumidityStatusIndex mandatory
The index to the temperature-humidity
status data table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.1
rPDU2SensorTempHumidityStatusModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.2
rPDU2SensorTempHumidityStatusName mandatory
The user-defined temperature-humidity
sensor ID string
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.3
rPDU2SensorTempHumidityStatusNumber mandatory
The temperature-humidity sensor numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.4
rPDU2SensorTempHumidityStatusType mandatory
The type of the sensor
Enumeration .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.5
rPDU2SensorTempHumidityStatusCommStatus mandatory
The communications status of the sensor
Enumeration .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.6
rPDU2SensorTempHumidityStatusTempF mandatory
Sensor temperature reading in tenths of degrees Fahrenheit
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.7
rPDU2SensorTempHumidityStatusTempC mandatory
Sensor temperature reading in tenths of degrees Celsius
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.8
rPDU2SensorTempHumidityStatusTempStatus mandatory
This OID reports the current state of the temperature probe.

A notPresent (1) response indicates that no probe is attached.
A belowMin (2) response indicates that the probe is present and
its measured tem…
Enumeration .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.9
rPDU2SensorTempHumidityStatusRelativeHumidity mandatory
Sensor humidity reading in percent relative humidity
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.10
rPDU2SensorTempHumidityStatusHumidityStatus mandatory
This OID reports the current state of the humidity probe.

A notPresent (1) response indicates that no probe is attached.
A belowMin (2) response indicates that the probe is present and
its measured humidi…
Enumeration .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.11
rPDU2SensorTempHumidityStatusTempPeakF mandatory
Sensor peak temperature in tenths of degrees Fahrenheit
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.12
rPDU2SensorTempHumidityStatusTempPeakC mandatory
Sensor peak temperature in tenths of degrees Celsius
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.13
rPDU2SensorTempHumidityStatusTempPeakTimestamp mandatory
Indicates the date and time that the peak temperature occurred
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.14
rPDU2SensorTempHumidityStatusTempPeakStartTime mandatory
Indicates the date and time of the last temperature peak reset
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.15
.1.3.6.1.4.1.63131.1.1.26.10.4.1 · 1 row entry · 6 columns
A table of discrete sensor configuration
data
rPDU2SensorDiscreteConfigEntry entry .1.3.6.1.4.1.63131.1.1.26.10.4.1.1
Configuration data from discreste sensor
being queried
Indexes
No indexes recorded
Column Syntax OID
rPDU2SensorDiscreteConfigIndex mandatory
The index to the discrete sensor configuration
data table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.4.1.1.1
rPDU2SensorDiscreteConfigModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.4.1.1.2
rPDU2SensorDiscreteConfigName mandatory
The user-defined discrete sensor ID string
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.10.4.1.1.3
rPDU2SensorDiscreteConfigNumber mandatory
The discrete sensor numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.4.1.1.4
rPDU2SensorDiscreteConfigNormalState mandatory
Indicates the normal state of the discrete input
contact
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.10.4.1.1.5
rPDU2SensorDiscreteConfigAbnormalSeverity mandatory
Indicates the severity of alarm triggered by
abnormal discrete input contact state
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.10.4.1.1.6
.1.3.6.1.4.1.63131.1.1.26.10.4.2 · 1 row entry · 8 columns
A table of discrete sensor status data
rPDU2SensorDiscreteStatusEntry entry .1.3.6.1.4.1.63131.1.1.26.10.4.2.1
Status information from discrete sensor
being queried
Indexes
No indexes recorded
Column Syntax OID
rPDU2SensorDiscreteStatusIndex mandatory
The index to the discrete sensor status data
table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.4.2.1.1
rPDU2SensorDiscreteStatusModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.4.2.1.2
rPDU2SensorDiscreteStatusName mandatory
The user-defined discrete sensor ID string
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.1.26.10.4.2.1.3
rPDU2SensorDiscreteStatusNumber mandatory
The discrete sensor numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.10.4.2.1.4
rPDU2SensorDiscreteStatusType mandatory
The type of discrete sensor currently being queried
Enumeration .1.3.6.1.4.1.63131.1.1.26.10.4.2.1.5
rPDU2SensorDiscreteStatusCommStatus mandatory
The communications status of the sensor
Enumeration .1.3.6.1.4.1.63131.1.1.26.10.4.2.1.6
rPDU2SensorDiscreteStatusCurrentState mandatory
The current open/close state of the discrete
sensor
Enumeration .1.3.6.1.4.1.63131.1.1.26.10.4.2.1.7
rPDU2SensorDiscreteStatusAlarmState mandatory
Indicates alarm status of discrete sensor input
Enumeration .1.3.6.1.4.1.63131.1.1.26.10.4.2.1.8
.1.3.6.1.4.1.63131.1.1.26.13.1 · 1 row entry · 5 columns
A table of Rack PDU phase to phase status data.
This table is only applicable to SKUs that have
phase to phase outputs.
rPDU2PhaseToPhaseStatusEntry entry .1.3.6.1.4.1.63131.1.1.26.13.1.1
Status data from currently queried Rack PDU
phase to phase outputs
Indexes
BLADE-MIBblowerControllerVpdIndex
Column Syntax OID
rPDU2PhaseToPhaseStatusIndex mandatory
The index to the Rack PDU phase to phase status table
entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.13.1.1.1
rPDU2PhaseToPhaseStatusModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.13.1.1.2
rPDU2PhaseToPhaseStatusVoltage1to2 mandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase 1 to phase 2 output being queried
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.13.1.1.3
rPDU2PhaseToPhaseStatusVoltage2to3 mandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase 2 to phase 3 output being queried
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.13.1.1.4
rPDU2PhaseToPhaseStatusVoltage3to1 mandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase 3 to phase 2 output being queried
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.13.1.1.5

rPDU2RCMTable

table mandatory
.1.3.6.1.4.1.63131.1.1.26.15.1 · 1 row entry · 8 columns
A table of Rack PDU RCM.
rPDU2RCMEntry entry .1.3.6.1.4.1.63131.1.1.26.15.1.1
RCM data from currently queried Rack PDU
Indexes
No indexes recorded
Column Syntax OID
rPDU2RCMIndex mandatory
The index to the Rack PDU RCM table entry
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.15.1.1.1
rPDU2RCMModule mandatory
The user-defined Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.15.1.1.2
rPDU2RCMCurrent mandatory
RCM RMS current. (mA)
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.15.1.1.3
rPDU2RCMAlarmStatus mandatory
RCM alarm status.
Setting the selected variable to 1,
will clear the over alarm.
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.15.1.1.4
rPDU2RCMSelfCheckCommand mandatory
Getting this variable will return the RCM self checking status,
1: featureNotAvailable(-1) 2: success(1) 3: failed(2) 4: pending(3).
Setting any of the selected pdu's rcm's variable to 1,
will immediately start RCM Sel…
Enumerationr/w .1.3.6.1.4.1.63131.1.1.26.15.1.1.5
rPDU2RCMWarningThreshold mandatory
Over Warning threshold of RCM current. (mA),
threshold can be set in the range of 15-300mA,
and must be lower or equal than Alarm threshold.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.15.1.1.6
rPDU2RCMAlarmThreshold mandatory
Over Alarm threshold of RCM current. (mA),
threshold can be set in the range of 15~300 mA,
and must be higher or equal than Warning threshold.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.15.1.1.7
rPDU2RCMSelfCheckPeriod mandatory
RCM Self-Checking Period. (day)
period can be set in the range of 1~365 days,
the rcm period on a single pdu is the same,
setting one of the selected pdu's rcm's period,
will change all rcm's period of this pdu.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.1.26.15.1.1.8

powerNetSoftwareTable

table mandatory
.1.3.6.1.4.1.63131.1.2.1.2.2 · 1 row entry · 4 columns
A list of the software monitoring the UPS.
powerNetSoftwareEntry entry .1.3.6.1.4.1.63131.1.2.1.2.2.1
An entry containing information on a software module.
Indexes
No indexes recorded
Column Syntax OID
moduleNumber mandatory
The index into the Software Entry Table
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.2.1.2.2.1.1
moduleName mandatory
The name of the software module.
OctetString .1.3.6.1.4.1.63131.1.2.1.2.2.1.2
moduleVersion mandatory
The version of the software module.
OctetString .1.3.6.1.4.1.63131.1.2.1.2.2.1.3
moduleDate mandatory
The date of the software module represented as mm-dd-yy.
OctetString .1.3.6.1.4.1.63131.1.2.1.2.2.1.4

pcnsNmcTable

table mandatory
.1.3.6.1.4.1.63131.1.2.3.3.4 · 1 row entry · 3 columns
The Network Management Cards in the UPS's which PCNS is monitoring to provide safe shutdown.
pcnsNmcEntry entry .1.3.6.1.4.1.63131.1.2.3.3.4.1
Details of the NMC.
Indexes
No indexes recorded
Column Syntax OID
pcnsNmcIndex mandatory
Index of the NMC within PCNS setup.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.63131.1.2.3.3.4.1.1
pcnsNmcAddr mandatory
The IP address of the NMC.
RFC1155-SMIIpAddress
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.63131.1.2.3.3.4.1.2
pcnsNmcOutlet mandatory
The Outlet Group which PCNS is enrolled with on the NMC.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.63131.1.2.3.3.4.1.3
.1.3.6.1.4.1.63131.1.2.3.5.9 · 1 row entry · 11 columns
The Network Management Cards in the UPS's which PCNS is monitoring to provide safe shutdown.
pcnsAdvancedShutdownEntry entry .1.3.6.1.4.1.63131.1.2.3.5.9.1
Details of the NMC.
Indexes
BLADE-MIBncHardwareVpdIndex
Column Syntax OID
pcnsAdvancedGroupNo mandatory
Index of the Advanced Shutdown Group.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.63131.1.2.3.5.9.1.1
pcnsAdvancedGroupName mandatory
Name of the Advanced Shutdown Group.
OctetStringr/w .1.3.6.1.4.1.63131.1.2.3.5.9.1.2
pcnsAdvancedGroupNMC mandatory
List of NMCs in the Advanced Shutdown Group.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.2.3.5.9.1.3
pcnsAdvancedShutdownUPSRequiredForLoad mandatory
Number of UPS's required to power load.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.2.3.5.9.1.4
pcnsAdvancedShutdownCommandFileEnabled mandatory
Run a shutdown command file before performing graceful shutdown.
Enumerationr/w .1.3.6.1.4.1.63131.1.2.3.5.9.1.5
pcnsAdvancedShutdownCommandFile mandatory
Full name of the shutdown command file to run before graceful shutdown.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.1.2.3.5.9.1.6
pcnsAdvancedShutdownCommandFileDuration mandatory
How long in seconds shutdown command file takes to run.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.1.2.3.5.9.1.7
pcnsAdvancedShutdownPowerchuteServer mandatory
Shut down PowerChute Server.
Enumerationr/w .1.3.6.1.4.1.63131.1.2.3.5.9.1.8
pcnsAdvancedShutdownOnLostRedundancy mandatory
Shut down if Redundancy lost.
Enumerationr/w .1.3.6.1.4.1.63131.1.2.3.5.9.1.9
pcnsAdvancedTurnOffUps mandatory
Turn off the UPS when performing a graceful shutdown.
Enumerationr/w .1.3.6.1.4.1.63131.1.2.3.5.9.1.10
pcnsAdvancedTurnOffSOG mandatory
Turn off the Outlet Group on the UPS when performing a graceful shutdown.
Enumerationr/w .1.3.6.1.4.1.63131.1.2.3.5.9.1.11
.1.3.6.1.4.1.63131.2.1.2 · 1 row entry · 6 columns
A list of managers to send traps to.  The number of
entries is given by the value of mconfigNumTrapReceivers.
mconfigTrapReceiverEntry entry .1.3.6.1.4.1.63131.2.1.2.1
The managers to send traps to.
Indexes
No indexes recorded
Column Syntax OID
trapIndex mandatory
The index to a trap receiver entry.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.63131.2.1.2.1.1
receiverAddr mandatory
The IP address of the manager to send a trap to.
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.63131.2.1.2.1.2
communityString mandatory
The community name to use in the trap when
sent to the manager.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.63131.2.1.2.1.3
severity obsolete
The severity threshold of traps to send to the manager.
traps are labeled in severity as informational(1), warning(2),
severe(3). Only traps of equal or greater severity than
this value are sent to the manager.
Enumeration .1.3.6.1.4.1.63131.2.1.2.1.4
acceptThisReceiver mandatory
The value of yes(1) indicates that trap generation for this manager is enabled.
The value of no(2) indicates that trap generation for this manager is disabled
Enumerationr/w .1.3.6.1.4.1.63131.2.1.2.1.5
receiveTrapType obsolete
Type of trap.
Enumeration .1.3.6.1.4.1.63131.2.1.2.1.6