PowerNet-Inova Table View
Table-centric layout grouping table, row, and column objects.
Tables
28
Rows
28
Columns
252
.1.3.6.1.4.1.63131.1.1.26.2
·
1 row entry
·
13 columns
A table of Rack PDU identification data
Identification data from Rack PDU being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2IdentIndex
mandatory
The index to the Rack PDU identification table
entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.2.1.1 |
|
rPDU2IdentModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.2.1.2 |
|
rPDU2IdentName
mandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.2.1.3 |
|
rPDU2IdentLocation
mandatory
A user-defined string identifying the location
of the Rack PDU |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.2.1.4 |
|
rPDU2IdentHardwareRev
mandatory
The Rack PDU hardware version
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.2.1.5 |
|
rPDU2IdentFirmwareRev
mandatory
The Rack PDU firmware version
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.2.1.6 |
|
rPDU2IdentDateOfManufacture
mandatory
The date the Rack PDU was manufactured
in mm/dd/yyyy format |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.2.1.7 |
|
rPDU2IdentModelNumber
mandatory
The Rack PDU model number
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.2.1.8 |
|
rPDU2IdentSerialNumber
mandatory
The Rack PDU serial number
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.2.1.9 |
|
rPDU2IdentContact
mandatory
A user-defined string identifying the
person to contact regarding the Rack PDU |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.2.1.10 |
|
rPDU2IdentBootMonitorRev
mandatory
The Rack PDU Boot Monitor version
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.2.1.11 |
|
rPDU2IdentLongDescription
mandatory
The Rack PDU Long Description name
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.2.1.12 |
|
rPDU2IdentNMCSerialNumber
mandatory
The Rack PDU Network Management Card (NMC) serial number
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.2.1.13 |
.1.3.6.1.4.1.63131.1.1.26.4.1
·
1 row entry
·
14 columns
A table of Rack PDU configuration data
Configuration data from Rack PDU being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2DeviceConfigIndex
mandatory
The index to the Rack PDU table entry
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.1 |
|
rPDU2DeviceConfigModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.2 |
|
rPDU2DeviceConfigName
mandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.3 |
|
rPDU2DeviceConfigLocation
mandatory
A user-defined string identifying the location
of the Rack PDU |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.4 |
|
rPDU2DeviceConfigDisplayOrientation
mandatory
Indicates the intended physical orientation
of the display. displayNormal(1) indicates normal orientation displayReverse(2) indicates upside down orientation |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.4.1.1.5 |
|
rPDU2DeviceConfigColdstartDelay
mandatory
The amount of delay, measured in seconds, between
when power is provided to the Rack PDU and when the Rack PDU provides basic master power to the outlets. Allowed values are: -1 - never apply power automatically. … |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.6 |
|
rPDU2DeviceConfigLowLoadPowerThreshold
mandatory
User-defined low power draw alarm threshold,
measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.7 |
|
rPDU2DeviceConfigNearOverloadPowerThreshold
mandatory
User-defined near power overload threshold,
measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.8 |
|
rPDU2DeviceConfigOverloadPowerThreshold
mandatory
User-defined power overload threshold,
measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.9 |
|
rPDU2DeviceConfigDevicePeakPowerReset
mandatory
Setting this OID to reset (2) will cause the existing peak power value
to be replaced by the current load power value. Getting this OID will do nothing and return the noOperation(1) value. Models that do … |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.4.1.1.10 |
|
rPDU2DeviceConfigDeviceEnergyReset
mandatory
Setting this OID to reset (2) will cause the device energy meter value
to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. … |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.4.1.1.11 |
|
rPDU2DeviceConfigOutletsEnergyReset
mandatory
Setting this OID to reset (2) will cause the all outlet energy meter values
to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value. Models that do not sup… |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.4.1.1.12 |
|
rPDU2DeviceConfigOutletsPeakLoadReset
mandatory
Setting this OID to reset (2) will cause the all outlet peak load values
to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value. Models that do not suppor… |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.4.1.1.13 |
|
rPDU2DeviceConfigContact
mandatory
A user-defined string identifying the
person to contact regarding the Rack PDU |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.14 |
.1.3.6.1.4.1.63131.1.1.26.4.2
·
1 row entry
·
13 columns
A table of Rack PDU properties
Properties of the Rack PDU being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2DevicePropertiesIndex
mandatory
The index to the Rack PDU properties table entry
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.1 |
|
rPDU2DevicePropertiesModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.2 |
|
rPDU2DevicePropertiesName
mandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.3 |
|
rPDU2DevicePropertiesNumOutlets
mandatory
The number of outlets on the Rack PDU
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.4 |
|
rPDU2DevicePropertiesNumSwitchedOutlets
mandatory
The number of switched outlets on the Rack PDU
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.5 |
|
rPDU2DevicePropertiesNumMeteredOutlets
mandatory
The number of metered outlets on the Rack PDU
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.6 |
|
rPDU2DevicePropertiesNumPhases
mandatory
The number of phases present in the Rack PDU
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.7 |
|
rPDU2DevicePropertiesNumMeteredBanks
mandatory
The number of metered banks present in the Rack PDU
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.8 |
|
rPDU2DevicePropertiesMaxCurrentRating
mandatory
The maximum current rating, measured in Amps, for
the Rack PDU |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.9 |
|
rPDU2DevicePropertiesOrientation
mandatory
Rack PDU orientation
|
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.2.1.10 |
|
rPDU2DevicePropertiesOutletLayout
mandatory
Getting this OID will return outlet layout for the device.
seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... or for single phase SKUs, all outlets 1-N … |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.2.1.11 |
|
rPDU2DevicePropertiesMaxPhaseCurrentRating
mandatory
The maximum current rating, measured in Amps, for
the Rack PDU |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.12 |
|
rPDU2DevicePropertiesDevicePowerRating
mandatory
The maximum power rating, measured in tenths of kilowatts, for
the Rack PDU |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.13 |
.1.3.6.1.4.1.63131.1.1.26.4.3
·
1 row entry
·
20 columns
A table of Rack PDU status information
Status information from the Rack PDU being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2DeviceStatusIndex
mandatory
The index to the Rack PDU status table entry
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.1 |
|
rPDU2DeviceStatusModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.2 |
|
rPDU2DeviceStatusName
mandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.3 |
|
rPDU2DeviceStatusLoadState
mandatory
Indicates the present load status of the Rack PDU.
Models that do not support this feature will respond to this OID with a value of notsupported (5). |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.3.1.4 |
|
rPDU2DeviceStatusPower
mandatory
The power consumption of the Rack PDU load in hundredths of kilowatts.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.5 |
|
rPDU2DeviceStatusPeakPower
mandatory
The peak power consumption of the Rack PDU load in hundredths of kilowatts.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.6 |
|
rPDU2DeviceStatusPeakPowerTimestamp
mandatory
Indicates the date and time that peak power consumption occurred.
Models that do not support this feature will respond to this OID with string 'notsupported'. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.7 |
|
rPDU2DeviceStatusPeakPowerStartTime
mandatory
Indicates the date and time of the last device peak power reset.
Models that do not support this feature will respond to this OID with string 'notsupported'. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.8 |
|
rPDU2DeviceStatusEnergy
mandatory
A user resettable energy meter measuring Rack PDU load
energy consumption in tenths of kilowatt-hours. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.9 |
|
rPDU2DeviceStatusEnergyStartTime
mandatory
Indicates the date and time of the last device energy
meter reset. Models that do not support this feature will respond to this OID with string 'notsupported'. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.10 |
|
rPDU2DeviceStatusCommandPending
mandatory
Indicates whether or not the device
is processing a pending command. If the commandPendingUnknown (3) value is returned, all devices powered by the Rack PDU should be shut down. The Rack PDU's power should then be cyc… |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.3.1.11 |
|
rPDU2DeviceStatusPowerSupplyAlarm
mandatory
Indicates a power supply alarm is active when value
equals alarm (2) |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.3.1.12 |
|
rPDU2DeviceStatusPowerSupply1Status
mandatory
Indicates whether or not an alarm is active in Power
Supply 1 |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.3.1.13 |
|
rPDU2DeviceStatusPowerSupply2Status
mandatory
Indicates whether or not an alarm is active in Power
Supply 2 |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.3.1.14 |
|
rPDU2DeviceStatusOutletsEnergyStartTime
mandatory
Indicates the date and time of the last outlets energy
meter reset. Models that do not support this feature will respond to this OID with string 'notsupported'. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.15 |
|
rPDU2DeviceStatusApparentPower
mandatory
The apparent power consumption of the Rack PDU load in hundredths of kiloVoltAmps (kVA).
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.16 |
|
rPDU2DeviceStatusPowerFactor
mandatory
The power factor of the Rack PDU load in hundredths. Models that do not support this feature
will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.17 |
|
rPDU2DeviceStatusNPSType
mandatory
The device NPS status:
notNPS (1) indicates the Rack PDU is not in an NPS group. host (2) indicates the Rack PDU has been designated as a host in an NPS group. Only one Rack PDU in an NPS group is allowed to be the ho… |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.3.1.18 |
|
rPDU2DeviceStatusResidualPower
mandatory
The measured device residual power from the PDU meters in hundredths of kiloVoltAmps.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.19 |
|
rPDU2DeviceStatusFrequency
mandatory
The measured device frequency from the PDU meters in tenths of Hz.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.20 |
.1.3.6.1.4.1.63131.1.1.26.4.4
·
1 row entry
·
4 columns
A table of Rack PDU control data
Control data from Rack PDU being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2DeviceControlIndex
mandatory
The index to the Rack PDU control table entry
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.4.1.1 |
|
rPDU2DeviceControlModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.4.1.2 |
|
rPDU2DeviceControlName
mandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.4.4.1.3 |
|
rPDU2DeviceControlCommand
mandatory
Setting this OID to immediateAllOn (1) will turn all outlets
on immediately. Setting this OID to delayedAllOn (2) will turn all outlets on as defined by each outlet's rPDU2OutletSwitchedConfigPowerOnTime … |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.4.4.1.4 |
.1.3.6.1.4.1.63131.1.1.26.6.1
·
1 row entry
·
8 columns
A table of Rack PDU phase configuration data
Configuration data from currently queried Rack
PDU phase
PDU phase
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2PhaseConfigIndex
mandatory
The index to the Rack PDU phase configuration
table entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.1.1.1 |
|
rPDU2PhaseConfigModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.1.1.2 |
|
rPDU2PhaseConfigNumber
mandatory
The numeric phase ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.1.1.3 |
|
rPDU2PhaseConfigOverloadRestriction
mandatory
This OID controls the behavior of a Switched Rack PDU
phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will alwa… |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.6.1.1.4 |
|
rPDU2PhaseConfigLowLoadCurrentThreshold
mandatory
User-defined low load phase current
threshold in Amps |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.1.1.5 |
|
rPDU2PhaseConfigNearOverloadCurrentThreshold
mandatory
User-defined near phase overload warning
threshold in Amps |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.1.1.6 |
|
rPDU2PhaseConfigOverloadCurrentThreshold
mandatory
User-defined phase overload current
threshold in Amps |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.1.1.7 |
|
rPDU2PhaseConfigPhasePeakCurrentReset
mandatory
Setting this OID to reset (2) will cause the existing peak current value
to be replaced by the present load current value. Getting this OID will do nothing and return the noOperation(1) value. |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.6.1.1.8 |
.1.3.6.1.4.1.63131.1.1.26.6.2
·
1 row entry
·
3 columns
A table of Rack PDU phase properties
Properties of the currently queried Rack
PDU phase
PDU phase
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2PhasePropertiesIndex
mandatory
The index to the Rack PDU phase properties
table entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.2.1.1 |
|
rPDU2PhasePropertiesModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.2.1.2 |
|
rPDU2PhasePropertiesNumber
mandatory
The numeric phase ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.2.1.3 |
.1.3.6.1.4.1.63131.1.1.26.6.3
·
1 row entry
·
14 columns
A table of Rack PDU phase status data
Status data from currently queried Rack PDU
phase
phase
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2PhaseStatusIndex
mandatory
The index to the Rack PDU phase status table
entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.1 |
|
rPDU2PhaseStatusModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.2 |
|
rPDU2PhaseStatusNumber
mandatory
The numeric phase ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.3 |
|
rPDU2PhaseStatusLoadState
mandatory
Indicates the present load status of the Rack PDU
phase being queried |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.6.3.1.4 |
|
rPDU2PhaseStatusCurrent
mandatory
Indicates the current draw, in tenths of Amps, of the load
on the Rack PDU phase being queried |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.5 |
|
rPDU2PhaseStatusVoltage
mandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.6 |
|
rPDU2PhaseStatusPower
mandatory
Indicates the load power, in hundredths of kilowatts (kW),
consumed on the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.7 |
|
rPDU2PhaseStatusApparentPower
mandatory
Indicates the load apparent power, in hundredths of kiloVoltAmps (kVA),
consumed on the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.8 |
|
rPDU2PhaseStatusPowerFactor
mandatory
Indicates the load power factor, in hundredths,
of the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.9 |
|
rPDU2PhaseStatusPeakCurrent
mandatory
The peak current of the Rack PDU phase load in tenths of Amps
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.10 |
|
rPDU2PhaseStatusPeakCurrentTimestamp
mandatory
Indicates the date and time that the peak current occurred
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.11 |
|
rPDU2PhaseStatusPeakCurrentStartTime
mandatory
Indicates the date and time of the last phase peak current reset
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.12 |
|
rPDU2PhaseStatusEnergy
mandatory
A user resettable energy meter measuring Rack PDU phase load
energy consumption in tenths of kilowatt-hours. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.13 |
|
rPDU2PhaseStatusBreaker
mandatory
Phase breaker status.
|
Enumeration | .1.3.6.1.4.1.63131.1.1.26.6.3.1.14 |
.1.3.6.1.4.1.63131.1.1.26.8.1
·
1 row entry
·
8 columns
A table of Rack PDU bank configuration data
Configuration data from currently queried
Rack PDU bank
Rack PDU bank
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2BankConfigIndex
mandatory
The index to the Rack PDU bank configuration
table entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.1.1.1 |
|
rPDU2BankConfigModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.1.1.2 |
|
rPDU2BankConfigNumber
mandatory
The numeric bank ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.1.1.3 |
|
rPDU2BankConfigOverloadRestriction
mandatory
This OID controls the behavior of a Switched Rack PDU
bank when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will alway… |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.8.1.1.4 |
|
rPDU2BankConfigLowLoadCurrentThreshold
mandatory
User-defined low load bank current
threshold in Amps |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.1.1.5 |
|
rPDU2BankConfigNearOverloadCurrentThreshold
mandatory
User-defined near bank overload current warning
threshold in Amps |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.1.1.6 |
|
rPDU2BankConfigOverloadCurrentThreshold
mandatory
User-defined bank overload current threshold
in Amps |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.1.1.7 |
|
rPDU2BankConfigBankPeakCurrentReset
mandatory
Setting this OID to reset (2) will cause the existing peak current value
to be replaced by the present load current value. Getting this OID will do nothing and return the noOperation(1) value. |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.8.1.1.8 |
.1.3.6.1.4.1.63131.1.1.26.8.2
·
1 row entry
·
5 columns
A table of Rack PDU bank properties
Properties of the currently queried
Rack PDU bank
Rack PDU bank
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2BankPropertiesIndex
mandatory
The index to the Rack PDU bank properties
table entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.2.1.1 |
||||||||||||
|
rPDU2BankPropertiesModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.2.1.2 |
||||||||||||
|
rPDU2BankPropertiesNumber
mandatory
The numeric bank ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.2.1.3 |
||||||||||||
|
rPDU2BankPropertiesPhaseLayout
mandatory
This OID describes the outlet phase connections on
the referenced bank as follows: seqPhase1ToNeutral(1) indicates that bank outlets are wired from Phase 1 to Neutral. seqPhase2ToNeutral(2)… |
Rpdu2OutletPhaseLayoutType Textual Convention: Rpdu2OutletPhaseLayoutType EnumerationType Values:
|
.1.3.6.1.4.1.63131.1.1.26.8.2.1.4 |
||||||||||||
|
rPDU2BankPropertiesBreakerRating
mandatory
If bank circuit breakers are present on the device, this OID will return
the rating of the breaker in Amps. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.2.1.5 |
.1.3.6.1.4.1.63131.1.1.26.8.3
·
1 row entry
·
11 columns
A table of Rack PDU bank status data
Status data from currently queried Rack PDU
bank
bank
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2BankStatusIndex
mandatory
The index to the Rack PDU bank status
table entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.1 |
|
rPDU2BankStatusModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.2 |
|
rPDU2BankStatusNumber
mandatory
The numeric bank ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.3 |
|
rPDU2BankStatusLoadState
mandatory
Indicates the present load status of the Rack PDU
bank being queried |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.8.3.1.4 |
|
rPDU2BankStatusCurrent
mandatory
Indicates the current draw, in tenths of Amps, of the load
on the Rack PDU bank being queried |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.5 |
|
rPDU2BankStatusPeakCurrent
mandatory
The peak current of the Rack PDU bank load in tenths of Amps
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.6 |
|
rPDU2BankStatusPeakCurrentTimestamp
mandatory
Indicates the date and time the bank peak current occurred
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.7 |
|
rPDU2BankStatusPeakCurrentStartTime
mandatory
Indicates the date and time of the last bank peak current reset
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.8 |
|
rPDU2BankStatusVoltage
mandatory
Indicates the Voltage, in Volts, of the Rack PDU bank being queried.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.9 |
|
rPDU2BankStatusPower
mandatory
Indicates the load power, in hundredths of kilowatts (kW),
consumed on the RackPDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.10 |
|
rPDU2BankStatusEnergy
mandatory
A user resettable energy meter measuring Rack PDU phase load
energy consumption in tenths of kilowatt-hours. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.11 |
.1.3.6.1.4.1.63131.1.1.26.9.2.1
·
1 row entry
·
8 columns
A table of Rack PDU switched outlet configuration data
Configuration data from currently queried
Rack PDU switched outlet
Rack PDU switched outlet
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2OutletSwitchedConfigIndex
mandatory
The index to the Rack PDU switched outlet
configuration table entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.1 |
|
rPDU2OutletSwitchedConfigModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.2 |
|
rPDU2OutletSwitchedConfigName
mandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.3 |
|
rPDU2OutletSwitchedConfigNumber
mandatory
The numeric switched outlet ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.4 |
|
rPDU2OutletSwitchedConfigPowerOnTime
mandatory
The amount of delay, in seconds, between when
power is provided to the Rack PDU and when this switched outlet starts providing power. Range -1...7200 where -1 = Never power on, 0 = immediate power on, and 1-7200 = secon… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.5 |
|
rPDU2OutletSwitchedConfigPowerOffTime
mandatory
The amount of time, in seconds, this outlet will
delay powering off. Range -1...7200 where -1 = Never power off, 0 = immediate power off, and 1-7200 = seconds to delay. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.6 |
|
rPDU2OutletSwitchedConfigRebootDuration
mandatory
After turning power off during a reboot sequence,
the amount of time to wait before turning power to this outlet back on. Range 5-60 seconds delay. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.7 |
|
rPDU2OutletSwitchedConfigExternalLink
mandatory
User-defined external device web link.
Possible use cases could be the IP address of the external device plugged into the outlet or its manufacturer web page for convenient support such as user manuals, specifications… |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.8 |
.1.3.6.1.4.1.63131.1.1.26.9.2.2
·
1 row entry
·
6 columns
A table of Rack PDU switched outlet properties
Properties of the currently queried Rack PDU
switched outlet
switched outlet
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2OutletSwitchedPropertiesIndex
mandatory
The index to the Rack PDU switched outlet
properties table entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.1 |
||||||||||||
|
rPDU2OutletSwitchedPropertiesModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.2 |
||||||||||||
|
rPDU2OutletSwitchedPropertiesName
mandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.3 |
||||||||||||
|
rPDU2OutletSwitchedPropertiesNumber
mandatory
The numeric switched outlet ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.4 |
||||||||||||
|
rPDU2OutletSwitchedPropertiesPhaseLayout
mandatory
This OID describes the phase connections of
the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicat… |
Rpdu2OutletPhaseLayoutType Textual Convention: Rpdu2OutletPhaseLayoutType EnumerationType Values:
|
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.5 |
||||||||||||
|
rPDU2OutletSwitchedPropertiesBank
mandatory
The numeric bank ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.6 |
.1.3.6.1.4.1.63131.1.1.26.9.2.3
·
1 row entry
·
7 columns
A table of Rack PDU switched outlet status information
Status information for currently queried
Rack PDU switched outlet
Rack PDU switched outlet
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2OutletSwitchedStatusIndex
mandatory
The index to the Rack PDU switched outlet
status information table entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.3.1.1 |
|
rPDU2OutletSwitchedStatusModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.3.1.2 |
|
rPDU2OutletSwitchedStatusName
mandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.9.2.3.1.3 |
|
rPDU2OutletSwitchedStatusNumber
mandatory
The numeric switched outlet ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.3.1.4 |
|
rPDU2OutletSwitchedStatusState
mandatory
Indicates the present switch state of the Rack
PDU switched outlet being queried |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.9.2.3.1.5 |
|
rPDU2OutletSwitchedStatusCommandPending
mandatory
Indicates whether or not the device is
processing a command for this outlet. If the commandPendingUnknown (3) value is returned, all devices powered by the Rack PDU should be shut down. The Rack PDU's po… |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.9.2.3.1.6 |
|
rPDU2OutletSwitchedStatusExternalLink
mandatory
Each RPDU outlet can have its own external web URL link.
This can be configured in the rPDU2OutletSwitchedConfigExternalLink OID. When this link is clicked in the web interface, the linked URL will open in the web b… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.9.2.3.1.7 |
.1.3.6.1.4.1.63131.1.1.26.9.2.4
·
1 row entry
·
5 columns
A table of Rack PDU switched outlet control data
Control data for currently queried Rack
PDU switched outlet
PDU switched outlet
Indexes
BLADE-MIBbladecKVMVpdIndex
| Column | Syntax | OID |
|---|---|---|
|
rPDU2OutletSwitchedControlIndex
mandatory
The index to the Rack PDU switched outlet
control data table entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.4.1.1 |
|
rPDU2OutletSwitchedControlModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.4.1.2 |
|
rPDU2OutletSwitchedControlName
mandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.9.2.4.1.3 |
|
rPDU2OutletSwitchedControlNumber
mandatory
The numeric switched outlet ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.4.1.4 |
|
rPDU2OutletSwitchedControlCommand
mandatory
Getting this variable will return the outlet state. If
the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. If the state of the outlet cannot b… |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.9.2.4.1.5 |
.1.3.6.1.4.1.63131.1.1.26.9.4.1
·
1 row entry
·
8 columns
A table of Rack PDU metered outlet configuration data
Configuration data from currently queried
Rack PDU metered outlet
Rack PDU metered outlet
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2OutletMeteredConfigIndex
mandatory
The index to the Rack PDU metered outlet
configuration table entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.1 |
|
rPDU2OutletMeteredConfigModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.2 |
|
rPDU2OutletMeteredConfigName
mandatory
The user-defined metered outlet ID string
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.3 |
|
rPDU2OutletMeteredConfigNumber
mandatory
The numeric switched outlet ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.4 |
|
rPDU2OutletMeteredConfigLowLoadCurrentThreshold
mandatory
User-defined low load outlet current threshold in in tenths of Amps
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.5 |
|
rPDU2OutletMeteredConfigNearOverloadCurrentThreshold
mandatory
User-defined near outlet overload warning threshold
in in tenths of Amps |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.6 |
|
rPDU2OutletMeteredConfigOverloadCurrentThreshold
mandatory
User-defined outlet overload current threshold in in tenths of Amps
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.7 |
|
rPDU2OutletMeteredConfigExternalLink
mandatory
User-defined external device web link.
Possible use cases could be the IP address of the external device plugged into the outlet or its manufacturer web page for convenient support such as user manuals, specifications… |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.8 |
.1.3.6.1.4.1.63131.1.1.26.9.4.2
·
1 row entry
·
7 columns
A table of Rack PDU metered outlet properties
Properties of currently queried Rack PDU
metered outlet
metered outlet
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2OutletMeteredPropertiesIndex
mandatory
The index to the Rack PDU metered properties table
entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.1 |
||||||||||||
|
rPDU2OutletMeteredPropertiesModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.2 |
||||||||||||
|
rPDU2OutletMeteredPropertiesName
mandatory
The user-defined metered outlet ID string
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.3 |
||||||||||||
|
rPDU2OutletMeteredPropertiesNumber
mandatory
The numeric metered outlet ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.4 |
||||||||||||
|
rPDU2OutletMeteredPropertiesLayout
mandatory
This OID describes the phase connections of
the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicat… |
Rpdu2OutletPhaseLayoutType Textual Convention: Rpdu2OutletPhaseLayoutType EnumerationType Values:
|
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.5 |
||||||||||||
|
rPDU2OutletMeteredPropertiesPowerRating
mandatory
Maximum power rating of Rack PDU metered outlet
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.6 |
||||||||||||
|
rPDU2OutletMeteredPropertiesBank
mandatory
This outlet's numeric bank ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.7 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3
·
1 row entry
·
16 columns
A table of Rack PDU metered outlet status data
Status data from currently queried Rack PDU
metered outlet
metered outlet
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2OutletMeteredStatusIndex
mandatory
The index to the Rack PDU metered status table
entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.1 |
|
rPDU2OutletMeteredStatusModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.2 |
|
rPDU2OutletMeteredStatusName
mandatory
The user-defined metered outlet ID string
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.3 |
|
rPDU2OutletMeteredStatusNumber
mandatory
The numeric metered outlet ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.4 |
|
rPDU2OutletMeteredStatusState
mandatory
Indicates the present load status of the Rack
PDU metered outlet being queried |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.9.4.3.1.5 |
|
rPDU2OutletMeteredStatusCurrent
mandatory
Indicates the current draw, in tenths
of Amps, of the load on the Rack PDU outlet being queried |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.6 |
|
rPDU2OutletMeteredStatusPower
mandatory
Indicates the power draw of the load
on the Rack PDU outlet being queried |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.7 |
|
rPDU2OutletMeteredStatusPeakPower
mandatory
Indicates the peak power load draw
on the Rack PDU outlet being queried |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.8 |
|
rPDU2OutletMeteredStatusPeakPowerTimestamp
mandatory
Indicates the date and time that this metered
outlet's peak power consumption occurred |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.9 |
|
rPDU2OutletMeteredStatusPeakPowerStartTime
mandatory
Indicates the start date and time that this metered
outlet began recording peak power observations |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.10 |
|
rPDU2OutletMeteredStatusEnergy
mandatory
A user resettable energy meter measuring Rack PDU load
energy consumption in tenths of kilowatt-hours |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.11 |
|
rPDU2OutletMeteredStatusReceptacleType
mandatory
Indicates receptacle type for the outlet.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.12 |
|
rPDU2OutletMeteredStatusExternalLink
mandatory
Each RPDU outlet can have its own external web URL link.
This can be configured in the rPDU2OutletMeteredConfigExternalLink OID. When this link is clicked in the web interface, the linked URL will open in the web br… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.13 |
|
rPDU2OutletMeteredStatusPowerFactor
mandatory
The power factor of the Rack PDU outlet in hundredths. Models that do not support this feature
will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.14 |
|
rPDU2OutletMeteredStatusApparentPower
mandatory
The apparent power consumption of the Rack PDU outlet load in hundredths of kiloVoltAmps (kVA).
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.15 |
|
rPDU2OutletMeteredStatusVoltage
mandatory
Indicates the Voltage, in Volts, of the Rack PDU outlet being queried.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.16 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1
·
1 row entry
·
16 columns
A table of temperature-humidity sensor configuration data
Configuration data from temperature-humidity sensor
being queried
being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2SensorTempHumidityConfigIndex
mandatory
The index to the temperature-humidity sensor
configuration data table entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.1 |
|
rPDU2SensorTempHumidityConfigModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.2 |
|
rPDU2SensorTempHumidityConfigName
mandatory
The user-defined temperature-humidity
sensor ID string |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.3 |
|
rPDU2SensorTempHumidityConfigNumber
mandatory
The temperature-humidity sensor numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.4 |
|
rPDU2SensorTempHumidityConfigTemperatureAlarmEnable
mandatory
Setting this OID enables or disables generation
of sensor temperature alarm. Getting this OID returns the current value of the temperature alarm enable. |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.10.2.1.1.5 |
|
rPDU2SensorTempHumidityConfigHumidityAlarmEnable
mandatory
Setting this OID enables or disables generation
of sensor humidity alarm. Getting this OID returns the current value of the humidity alarm enable. |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.10.2.1.1.6 |
|
rPDU2SensorTempHumidityConfigTempMaxThreshF
mandatory
Sensor maximum temperature alarm threshold in
Fahrenheit. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigTempHighThreshF will result in an error. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.7 |
|
rPDU2SensorTempHumidityConfigTempHighThreshF
mandatory
Sensor high temperature warning alarm threshold
in Fahrenheit. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigTempMaxThreshF will result in an error. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.8 |
|
rPDU2SensorTempHumidityConfigTempHysteresisF
mandatory
Sensor temperature hysteresis setting in Fahrenheit
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.9 |
|
rPDU2SensorTempHumidityConfigTempMaxThreshC
mandatory
Sensor maximum temperature alarm threshold
in Celsius. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigTempHighThreshC will result in an error. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.10 |
|
rPDU2SensorTempHumidityConfigTempHighThreshC
mandatory
Sensor high temperature warning alarm threshold
in Celsius. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigTempMaxThreshC will result in an error. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.11 |
|
rPDU2SensorTempHumidityConfigTempHysteresisC
mandatory
Sensor temperature hysteresis setting in Celsius
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.12 |
|
rPDU2SensorTempHumidityConfigHumidityLowThresh
mandatory
Sensor low humidity warning alarm threshold in percent
relative humidity. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigHumidityMinThresh will result in an error. Must … |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.13 |
|
rPDU2SensorTempHumidityConfigHumidityMinThresh
mandatory
Sensor minimum humidity alarm threshold in percent
relative humidity. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigHumidityLowThresh will result in an error. Must b… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.14 |
|
rPDU2SensorTempHumidityConfigHumidityHysteresis
mandatory
Sensor humidity hysteresis setting in percent relative
humidity |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.15 |
|
rPDU2SensorTempHumidityConfigTempPeakReset
mandatory
Setting this OID to reset (2) will cause the existing peak temperature
to be replaced by the present temperature reading. Getting this OID will do nothing and return the noOperation(1) value. |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.10.2.1.1.16 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2
·
1 row entry
·
15 columns
A table of temperature-humidity sensor status data
Status information from temperature-humidity sensor
being queried
being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2SensorTempHumidityStatusIndex
mandatory
The index to the temperature-humidity
status data table entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.1 |
|
rPDU2SensorTempHumidityStatusModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.2 |
|
rPDU2SensorTempHumidityStatusName
mandatory
The user-defined temperature-humidity
sensor ID string |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.3 |
|
rPDU2SensorTempHumidityStatusNumber
mandatory
The temperature-humidity sensor numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.4 |
|
rPDU2SensorTempHumidityStatusType
mandatory
The type of the sensor
|
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.5 |
|
rPDU2SensorTempHumidityStatusCommStatus
mandatory
The communications status of the sensor
|
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.6 |
|
rPDU2SensorTempHumidityStatusTempF
mandatory
Sensor temperature reading in tenths of degrees Fahrenheit
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.7 |
|
rPDU2SensorTempHumidityStatusTempC
mandatory
Sensor temperature reading in tenths of degrees Celsius
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.8 |
|
rPDU2SensorTempHumidityStatusTempStatus
mandatory
This OID reports the current state of the temperature probe.
A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that the probe is present and its measured tem… |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.9 |
|
rPDU2SensorTempHumidityStatusRelativeHumidity
mandatory
Sensor humidity reading in percent relative humidity
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.10 |
|
rPDU2SensorTempHumidityStatusHumidityStatus
mandatory
This OID reports the current state of the humidity probe.
A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that the probe is present and its measured humidi… |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.11 |
|
rPDU2SensorTempHumidityStatusTempPeakF
mandatory
Sensor peak temperature in tenths of degrees Fahrenheit
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.12 |
|
rPDU2SensorTempHumidityStatusTempPeakC
mandatory
Sensor peak temperature in tenths of degrees Celsius
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.13 |
|
rPDU2SensorTempHumidityStatusTempPeakTimestamp
mandatory
Indicates the date and time that the peak temperature occurred
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.14 |
|
rPDU2SensorTempHumidityStatusTempPeakStartTime
mandatory
Indicates the date and time of the last temperature peak reset
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.15 |
.1.3.6.1.4.1.63131.1.1.26.10.4.1
·
1 row entry
·
6 columns
A table of discrete sensor configuration data
Configuration data from discreste sensor
being queried
being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2SensorDiscreteConfigIndex
mandatory
The index to the discrete sensor configuration
data table entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.4.1.1.1 |
|
rPDU2SensorDiscreteConfigModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.4.1.1.2 |
|
rPDU2SensorDiscreteConfigName
mandatory
The user-defined discrete sensor ID string
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.10.4.1.1.3 |
|
rPDU2SensorDiscreteConfigNumber
mandatory
The discrete sensor numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.4.1.1.4 |
|
rPDU2SensorDiscreteConfigNormalState
mandatory
Indicates the normal state of the discrete input
contact |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.10.4.1.1.5 |
|
rPDU2SensorDiscreteConfigAbnormalSeverity
mandatory
Indicates the severity of alarm triggered by
abnormal discrete input contact state |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.10.4.1.1.6 |
.1.3.6.1.4.1.63131.1.1.26.10.4.2
·
1 row entry
·
8 columns
A table of discrete sensor status data
Status information from discrete sensor
being queried
being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2SensorDiscreteStatusIndex
mandatory
The index to the discrete sensor status data
table entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.4.2.1.1 |
|
rPDU2SensorDiscreteStatusModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.4.2.1.2 |
|
rPDU2SensorDiscreteStatusName
mandatory
The user-defined discrete sensor ID string
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.1.26.10.4.2.1.3 |
|
rPDU2SensorDiscreteStatusNumber
mandatory
The discrete sensor numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.4.2.1.4 |
|
rPDU2SensorDiscreteStatusType
mandatory
The type of discrete sensor currently being queried
|
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.4.2.1.5 |
|
rPDU2SensorDiscreteStatusCommStatus
mandatory
The communications status of the sensor
|
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.4.2.1.6 |
|
rPDU2SensorDiscreteStatusCurrentState
mandatory
The current open/close state of the discrete
sensor |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.4.2.1.7 |
|
rPDU2SensorDiscreteStatusAlarmState
mandatory
Indicates alarm status of discrete sensor input
|
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.4.2.1.8 |
.1.3.6.1.4.1.63131.1.1.26.13.1
·
1 row entry
·
5 columns
A table of Rack PDU phase to phase status data. This table is only applicable to SKUs that have phase to phase outputs.
Status data from currently queried Rack PDU
phase to phase outputs
phase to phase outputs
Indexes
BLADE-MIBblowerControllerVpdIndex
| Column | Syntax | OID |
|---|---|---|
|
rPDU2PhaseToPhaseStatusIndex
mandatory
The index to the Rack PDU phase to phase status table
entry |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.13.1.1.1 |
|
rPDU2PhaseToPhaseStatusModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.13.1.1.2 |
|
rPDU2PhaseToPhaseStatusVoltage1to2
mandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase 1 to phase 2 output being queried |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.13.1.1.3 |
|
rPDU2PhaseToPhaseStatusVoltage2to3
mandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase 2 to phase 3 output being queried |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.13.1.1.4 |
|
rPDU2PhaseToPhaseStatusVoltage3to1
mandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase 3 to phase 2 output being queried |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.13.1.1.5 |
.1.3.6.1.4.1.63131.1.1.26.15.1
·
1 row entry
·
8 columns
A table of Rack PDU RCM.
RCM data from currently queried Rack PDU
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2RCMIndex
mandatory
The index to the Rack PDU RCM table entry
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.15.1.1.1 |
|
rPDU2RCMModule
mandatory
The user-defined Rack PDU numeric ID
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.15.1.1.2 |
|
rPDU2RCMCurrent
mandatory
RCM RMS current. (mA)
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.15.1.1.3 |
|
rPDU2RCMAlarmStatus
mandatory
RCM alarm status.
Setting the selected variable to 1, will clear the over alarm. |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.15.1.1.4 |
|
rPDU2RCMSelfCheckCommand
mandatory
Getting this variable will return the RCM self checking status,
1: featureNotAvailable(-1) 2: success(1) 3: failed(2) 4: pending(3). Setting any of the selected pdu's rcm's variable to 1, will immediately start RCM Sel… |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.15.1.1.5 |
|
rPDU2RCMWarningThreshold
mandatory
Over Warning threshold of RCM current. (mA),
threshold can be set in the range of 15-300mA, and must be lower or equal than Alarm threshold. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.15.1.1.6 |
|
rPDU2RCMAlarmThreshold
mandatory
Over Alarm threshold of RCM current. (mA),
threshold can be set in the range of 15~300 mA, and must be higher or equal than Warning threshold. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.15.1.1.7 |
|
rPDU2RCMSelfCheckPeriod
mandatory
RCM Self-Checking Period. (day)
period can be set in the range of 1~365 days, the rcm period on a single pdu is the same, setting one of the selected pdu's rcm's period, will change all rcm's period of this pdu. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.15.1.1.8 |
.1.3.6.1.4.1.63131.1.2.1.2.2
·
1 row entry
·
4 columns
A list of the software monitoring the UPS.
An entry containing information on a software module.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
moduleNumber
mandatory
The index into the Software Entry Table
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.2.1.2.2.1.1 |
|
moduleName
mandatory
The name of the software module.
|
OctetString | .1.3.6.1.4.1.63131.1.2.1.2.2.1.2 |
|
moduleVersion
mandatory
The version of the software module.
|
OctetString | .1.3.6.1.4.1.63131.1.2.1.2.2.1.3 |
|
moduleDate
mandatory
The date of the software module represented as mm-dd-yy.
|
OctetString | .1.3.6.1.4.1.63131.1.2.1.2.2.1.4 |
.1.3.6.1.4.1.63131.1.2.3.3.4
·
1 row entry
·
3 columns
The Network Management Cards in the UPS's which PCNS is monitoring to provide safe shutdown.
Details of the NMC.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
pcnsNmcIndex
mandatory
Index of the NMC within PCNS setup.
|
RFC1155-SMIGauge Textual Convention: RFC1155-SMIGauge Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.63131.1.2.3.3.4.1.1 |
|
pcnsNmcAddr
mandatory
The IP address of the NMC.
|
RFC1155-SMIIpAddress Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.63131.1.2.3.3.4.1.2 |
|
pcnsNmcOutlet
mandatory
The Outlet Group which PCNS is enrolled with on the NMC.
|
RFC1155-SMIGauge Textual Convention: RFC1155-SMIGauge Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.63131.1.2.3.3.4.1.3 |
.1.3.6.1.4.1.63131.1.2.3.5.9
·
1 row entry
·
11 columns
The Network Management Cards in the UPS's which PCNS is monitoring to provide safe shutdown.
Details of the NMC.
Indexes
BLADE-MIBncHardwareVpdIndex
| Column | Syntax | OID |
|---|---|---|
|
pcnsAdvancedGroupNo
mandatory
Index of the Advanced Shutdown Group.
|
RFC1155-SMIGauge Textual Convention: RFC1155-SMIGauge Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.63131.1.2.3.5.9.1.1 |
|
pcnsAdvancedGroupName
mandatory
Name of the Advanced Shutdown Group.
|
OctetStringr/w | .1.3.6.1.4.1.63131.1.2.3.5.9.1.2 |
|
pcnsAdvancedGroupNMC
mandatory
List of NMCs in the Advanced Shutdown Group.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.2.3.5.9.1.3 |
|
pcnsAdvancedShutdownUPSRequiredForLoad
mandatory
Number of UPS's required to power load.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.2.3.5.9.1.4 |
|
pcnsAdvancedShutdownCommandFileEnabled
mandatory
Run a shutdown command file before performing graceful shutdown.
|
Enumerationr/w | .1.3.6.1.4.1.63131.1.2.3.5.9.1.5 |
|
pcnsAdvancedShutdownCommandFile
mandatory
Full name of the shutdown command file to run before graceful shutdown.
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.1.2.3.5.9.1.6 |
|
pcnsAdvancedShutdownCommandFileDuration
mandatory
How long in seconds shutdown command file takes to run.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.2.3.5.9.1.7 |
|
pcnsAdvancedShutdownPowerchuteServer
mandatory
Shut down PowerChute Server.
|
Enumerationr/w | .1.3.6.1.4.1.63131.1.2.3.5.9.1.8 |
|
pcnsAdvancedShutdownOnLostRedundancy
mandatory
Shut down if Redundancy lost.
|
Enumerationr/w | .1.3.6.1.4.1.63131.1.2.3.5.9.1.9 |
|
pcnsAdvancedTurnOffUps
mandatory
Turn off the UPS when performing a graceful shutdown.
|
Enumerationr/w | .1.3.6.1.4.1.63131.1.2.3.5.9.1.10 |
|
pcnsAdvancedTurnOffSOG
mandatory
Turn off the Outlet Group on the UPS when performing a graceful shutdown.
|
Enumerationr/w | .1.3.6.1.4.1.63131.1.2.3.5.9.1.11 |
.1.3.6.1.4.1.63131.2.1.2
·
1 row entry
·
6 columns
A list of managers to send traps to. The number of entries is given by the value of mconfigNumTrapReceivers.
The managers to send traps to.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
trapIndex
mandatory
The index to a trap receiver entry.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.2.1.2.1.1 |
|
receiverAddr
mandatory
The IP address of the manager to send a trap to.
|
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.63131.2.1.2.1.2 |
|
communityString
mandatory
The community name to use in the trap when
sent to the manager. |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.63131.2.1.2.1.3 |
|
severity
obsolete
The severity threshold of traps to send to the manager.
traps are labeled in severity as informational(1), warning(2), severe(3). Only traps of equal or greater severity than this value are sent to the manager. |
Enumeration | .1.3.6.1.4.1.63131.2.1.2.1.4 |
|
acceptThisReceiver
mandatory
The value of yes(1) indicates that trap generation for this manager is enabled.
The value of no(2) indicates that trap generation for this manager is disabled |
Enumerationr/w | .1.3.6.1.4.1.63131.2.1.2.1.5 |
|
receiveTrapType
obsolete
Type of trap.
|
Enumeration | .1.3.6.1.4.1.63131.2.1.2.1.6 |