PM-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
8
Rows
8
Columns
242
.1.3.6.1.4.1.10418.17.2.2.2 · 1 row entry · 8 columns
This table contains the list of active sessions.
pmActiveSessionsTableEntry entry .1.3.6.1.4.1.10418.17.2.2.2.1
each entry has the information about the active session
Indexes
pmActiveSessionsTableIndex
Column Syntax OID
pmActiveSessionsTableIndex
A unique index representing an entry in this table.
IF-MIBInterfaceIndexOrZero
Textual Convention: IF-MIBInterfaceIndexOrZero Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.10418.17.2.2.2.1.1
pmActiveSessionsTableUser
The name of the user that opens this session.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.17.2.2.2.1.2
pmActiveSessionsTableGroup
The name of the group that the user belongs to.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.17.2.2.2.1.3
pmActiveSessionsTableType
The session type.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.17.2.2.2.1.4
pmActiveSessionsTableConnection
Connection type.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.17.2.2.2.1.5
pmActiveSessionsTableSessionTime
Time of the session
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.17.2.2.2.1.6
pmActiveSessionsTableFrom
The source IP address of the session.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.17.2.2.2.1.7
pmActiveSessionsTableKill
A set value of killSession(2) will kill the session.
noAction(1) = always returned in a GET. Does nothing if SET.
killSession(2)= when SET the appliance immediately kills the session.
Enumerationr/w
Enumerated Values:
1noAction
2killSession
.1.3.6.1.4.1.10418.17.2.2.2.1.8
.1.3.6.1.4.1.10418.17.2.5.2 · 1 row entry · 12 columns
Information about each serial port thas has PDU connect.
pmPowerMgmtSerialTableEntry entry .1.3.6.1.4.1.10418.17.2.5.2.1
Information about each serial port thas has PDU connect.
Indexes
pmPowerMgmtSerialTableIndex
Column Syntax OID
pmPowerMgmtSerialTableIndex
The index of the register.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.17.2.5.2.1.1
pmPowerMgmtSerialTablePortNumber
The number of the serial port when the PDU is connected.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.2.1.2
pmPowerMgmtSerialTableDeviceName
The device name of this serial port.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.2.1.3
pmPowerMgmtSerialTableNumberPDUs
Total number of units connected in this serial port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.2.1.4
pmPowerMgmtSerialTableBuzzer
set/get buzzer(s) on or off for the chain.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.2.1.10
pmPowerMgmtSerialTableSyslog
set/get syslog on or off for the chain.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.2.1.11
pmPowerMgmtSerialTableOverCurrent
set/get over current proctection on or off for the chain.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.2.1.12
pmPowerMgmtSerialTableCycleInterval
set/get cycle interval for the chain in whole seconds.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.2.1.13
pmPowerMgmtSerialTablePollRate
set/get the poll rate for the chain in whole seconds.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.2.1.14
pmPowerMgmtSerialTablePassWord
set the global password for admin user
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.2.1.15
pmPowerMgmtSerialTableSave
noAction(1) = always returned in a GET. Does nothing if SET.
save(2) = when SET the save command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2save
.1.3.6.1.4.1.10418.17.2.5.2.1.20
pmPowerMgmtSerialTableRestore
noAction(1) = always returned in a GET. Does nothing if SET.
restore(2) = when SET the restore command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2restore
.1.3.6.1.4.1.10418.17.2.5.2.1.21
.1.3.6.1.4.1.10418.17.2.5.3 · 1 row entry · 76 columns
This table contains the list of detected PDUs.
pmPowerMgmtPDUTableEntry entry .1.3.6.1.4.1.10418.17.2.5.3.1
each entry has the information about the PDU.
Indexes
pmPowerMgmtPDUTablePortNumber pmPowerMgmtPDUTablePduIndex
Column Syntax OID
pmPowerMgmtPDUTablePortNumber
Number of serial port when the PDU is connected.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.1
pmPowerMgmtPDUTablePduIndex
A PDU position in the chain.
IF-MIBInterfaceIndexOrZero
Textual Convention: IF-MIBInterfaceIndexOrZero Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.2
pmPowerMgmtPDUTablePduId
PDU identification.
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.3.1.3
pmPowerMgmtPDUTablePortName
Name of serial port when the PDU is connected.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.3.1.4
pmPowerMgmtPDUTableModel
Model of the PDU.
Returns N/A if not applicable.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.3.1.5
pmPowerMgmtPDUTableVendor
Vendor of the PDU.
Returns N/A if not applicable.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.3.1.6
pmPowerMgmtPDUTableFirmwareVersion
Version of the PDU firmware.
Returns N/A if not applicable.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.3.1.7
pmPowerMgmtPDUTableNumberOfOutlets
Number of outlets of the PDU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.8
pmPowerMgmtPDUTableCurrentNOS obsolete
Number of current sensors in the PDU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.9
pmPowerMgmtPDUTableCurrent1Value obsolete
Current of the sensor 1 in this PDU unit in AMP.
The value of this object is the actual current in
AMP * 10. You need to translate the readed value
(Ex. : value is 5, the current is 0.5 AMP.).
This OID is obsoleted. Th…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.10
pmPowerMgmtPDUTableCurrent1Max obsolete
Maximum current of the sensor 1 in this PDU unit in AMP.
When the PDU does not have support for maximum value,
the value will be 0.
The value of this object is the actual current in
AMP * 10. You need to translate the …
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.11
pmPowerMgmtPDUTableCurrent2Value obsolete
Current of the sensor 2 in this PDU unit in AMP.
The value of this object is the actual current in
AMP * 10. You need to translate the readed value
(Ex. : value is 5, the current is 0.5 AMP.).
This OID is obsoleted. T…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.12
pmPowerMgmtPDUTableCurrent2Max obsolete
Maximum current of the sensor 2 in this PDU unit in AMP.
When the PDU does not have support for maximum value,
the value will be 0.
The value of this object is the actual current in
AMP * 10. You need to translate the …
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.13
pmPowerMgmtPDUTableCurrent3Value obsolete
Current of the sensor 3 in this PDU unit in AMP.
The value of this object is the actual current in
AMP * 10. You need to translate the readed value
(Ex. : value is 5, the current is 0.5 AMP.)
This OID is obsoleted. Th…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.14
pmPowerMgmtPDUTableCurrent3Max obsolete
Maximum current of the sensor 3 in this PDU unit in AMP.
When the PDU does not have support for maximum value,
the value will be 0.
The value of this object is the actual current in
AMP * 10. You need to translate the …
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.15
pmPowerMgmtPDUTableTemperatureNOS obsolete
Number of temperature sensors in the PDU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.16
pmPowerMgmtPDUTableTemperature1Value obsolete
Temperature of this PM unit in Celsius degrees.
The value of this object is the actual temperature in
degrees C * 10. You need to translate the readed value
(Ex. : value is 240, the temperature is 24 Celsius.)
If the …
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.17
pmPowerMgmtPDUTableTemperature1Max obsolete
Maximum temperature detected in this PM unit in Celsius degrees.
The value will be Zero when the PDU does not have support for maximum value.
The value of this object is the actual temperature in
degrees C * 10. You …
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.18
pmPowerMgmtPDUTableTemperature2Value obsolete
Temperature of this PM unit in Celsius degrees.
The value of this object is the actual temperature in
degrees C * 10. You need to translate the readed value
(Ex. : value is 240, the temperature is 24 Celsius.)
If the …
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.19
pmPowerMgmtPDUTableTemperature2Max obsolete
Maximum temperature detected in this PM unit in Celsius degrees.
The value will be Zero when the PDU does not have support for maximum value.
The value of this object is the actual temperature in
degrees C * 10. You ne…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.20
pmPowerMgmtPDUTableTemperature3Value obsolete
Temperature of this PM unit in Celsius degrees.
The value of this object is the actual temperature in
degrees C * 10. You need to translate the readed value
(Ex. : value is 240, the temperature is 24 Celsius.)
If the …
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.21
pmPowerMgmtPDUTableTemperature3Max obsolete
Maximum temperature detected in this PM unit in Celsius degrees.
The value will be Zero when the PDU does not have support for maximum value.
The value of this object is the actual temperature in
degrees C * 10. You …
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.22
pmPowerMgmtPDUTableHumidityNOS obsolete
Number of humidity sensors in the PDU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.23
pmPowerMgmtPDUTableHumidity1Value obsolete
Humidity of this PM unit .
If the humidity measurement is not installed this
value will be 0.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.24
pmPowerMgmtPDUTableHumidity1Max obsolete
Maximum humidity detected in this PM unit.
If the humidity measurement is not installed or the PDU does not have support for maximum value this
value will be 0.
Set with Zero value to clear the max. temperature.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.25
pmPowerMgmtPDUTableHumidity2Value obsolete
Humidity of this PM unit .
If the humidity measurement is not installed this
value will be 0.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.26
pmPowerMgmtPDUTableHumidity2Max obsolete
Maximum humidity detected in this PM unit.
If the humidity measurement is not installed or the PDU does not have support for maximum value this
value will be 0.
Set with Zero value to clear the max. temperature.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.27
pmPowerMgmtPDUTableHumidity3Value obsolete
Humidity of this PM unit .
If the humidity measurement is not installed this
value will be 0.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.28
pmPowerMgmtPDUTableHumidity3Max obsolete
Maximum humidity detected in this PM unit.
If the humidity measurement is not installed or the PDU does not have support for maximum value this
value will be 0.
Set with Zero value to clear the max. temperature.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.29
pmPowerMgmtPDUTableVoltageNOS obsolete
Number of voltage sensors in the PDU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.30
pmPowerMgmtPDUTableVoltage1Value obsolete
Voltage of this sensor in this PDU unit.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableVoltageValue,
pmPowerMgmtPhasesTableVoltageValue, or
pmPowerMgmtOutletsTableVoltageValue
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.31
pmPowerMgmtPDUTableVoltage1Max obsolete
Maximum voltage of this sensor in this PDU unit.
Set with Zero value to clear the maximum voltage.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableVoltageMax,
pmPowerMgmtPhasesTableVoltageMax…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.32
pmPowerMgmtPDUTableVoltage2Value obsolete
Voltage of this sensor in this PDU unit.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableVoltageValue,
pmPowerMgmtPhasesTableVoltageValue, or
pmPowerMgmtOutletsTableVoltageValue
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.33
pmPowerMgmtPDUTableVoltage2Max obsolete
Maximum voltage of this sensor in this PDU unit.
Set with Zero value to clear the maximum voltage.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableVoltageMax,
pmPowerMgmtPhasesTableVoltageMax…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.34
pmPowerMgmtPDUTableVoltage3Value obsolete
Voltage of this sensor in this PDU unit.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableVoltageValue,
pmPowerMgmtPhasesTableVoltageValue, or
pmPowerMgmtOutletsTableVoltageValue
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.35
pmPowerMgmtPDUTableVoltage3Max obsolete
Maximum voltage of this sensor in this PDU unit.
Set with Zero value to clear the maximum voltage.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableVoltageMax,
pmPowerMgmtPhasesTableVoltageMax…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.36
pmPowerMgmtPDUTableNumberOfPhases
Number of phases of the PDU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.37
pmPowerMgmtPDUTableNumberOfBanks
Number of banks in the PDU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.38
pmPowerMgmtPDUTableNumberOfSensors
Number of sensors in the PDU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.40
pmPowerMgmtPDUTableFactoryDefault
A set value of 2 will set the PDU to factory default settings.
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the factory default command is sent to the PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.3.1.41
pmPowerMgmtPDUTableColdStartDelay
PDUs cold start delay in whole seconds (0-60).
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.42
pmPowerMgmtPDUTableReboot
A set value of power*(2) will send command to PDU.
noAction(1) = always returned in a GET. Does nothing if SET.
reboot(2) = when SET the reboot command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reboot
.1.3.6.1.4.1.10418.17.2.5.3.1.43
pmPowerMgmtPDUTableMaxCurrent
Maximum value of current allowed in the PDU (A x 10).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.44
pmPowerMgmtPDUTableAlarm
Show the PDU alarm status.
Returns 0 if not supported.
Enumeration
Enumerated Values:
1normal
2blow-fuse
3hw-ocp
4high-critical
5high-warning
6low-warning
7low-critical
.1.3.6.1.4.1.10418.17.2.5.3.1.45
pmPowerMgmtPDUTableCurrentValue
Actual value of current in the PDU (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.50
pmPowerMgmtPDUTableCurrentMax
Maximum value of current in the PDU (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.51
pmPowerMgmtPDUTableCurrentMin
Minimum value of current in the PDU (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.52
pmPowerMgmtPDUTableCurrentAvg
Average value of current in the PDU (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.53
pmPowerMgmtPDUTableCurrentReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.3.1.54
pmPowerMgmtPDUTablePowerValue
Actual value of power in the PDU (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.60
pmPowerMgmtPDUTablePowerMax
Maximum value of power in the PDU (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.61
pmPowerMgmtPDUTablePowerMin
Minimum value of power in the PDU (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.62
pmPowerMgmtPDUTablePowerAvg
Average value of power in the PDU (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.63
pmPowerMgmtPDUTablePowerReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.3.1.64
pmPowerMgmtPDUTablePowerType
Type of power values.
Returns 0 if not supported.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2measured
.1.3.6.1.4.1.10418.17.2.5.3.1.65
pmPowerMgmtPDUTableVoltageValue
Actual value of voltage in the PDU (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.70
pmPowerMgmtPDUTableVoltageMax
Maximum value of voltage in the PDU (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.71
pmPowerMgmtPDUTableVoltageMin
Minimum value of voltage in the PDU (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.72
pmPowerMgmtPDUTableVoltageAvg
Average value of voltage in the PDU (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.73
pmPowerMgmtPDUTableVoltageReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.3.1.74
pmPowerMgmtPDUTableVoltageType
Type of voltage values.
Returns 0 if not supported.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2measured
.1.3.6.1.4.1.10418.17.2.5.3.1.75
pmPowerMgmtPDUTablePowerFactorValue
Actual value of power factor in the PDU (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.80
pmPowerMgmtPDUTablePowerFactorMax
Maximum value of power factor in the PDU (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.81
pmPowerMgmtPDUTablePowerFactorMin
Minimum value of power factor in the PDU (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.82
pmPowerMgmtPDUTablePowerFactorAvg
Average value of power factor in the PDU (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.83
pmPowerMgmtPDUTablePowerFactorReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.3.1.84
pmPowerMgmtPDUTablePowerFactorType
Type of power values.
Returns 0 if not supported.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2measured
.1.3.6.1.4.1.10418.17.2.5.3.1.85
pmPowerMgmtPDUTablePowerControl
A set value of power*(2-4) will send command to PDU.
noAction(1) = always returned in a GET. Does nothing if SET.
powerOn(2) = when SET the power On command is sent to PDU.
powerOff(3) = when SET the power Off command …
Enumerationr/w
Enumerated Values:
1noAction
2powerOn
3powerOff
4powerCycle
.1.3.6.1.4.1.10418.17.2.5.3.1.90
pmPowerMgmtPDUTableResetOCP
A set value of power*(2) will send command to PDU.
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Returns 0 if not supported.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.3.1.91
pmPowerMgmtPDUTableCurrentHighCritical
outlet high critical (alarm) current threshold (A x 10).
Set fails if value is lower that CurrentHighWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.100
pmPowerMgmtPDUTableCurrentHighWarning
outlet high warning current threshold (A x 10).
Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.101
pmPowerMgmtPDUTableCurrentLowWarning
outlet low warning current threshold (A x 10).
Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.102
pmPowerMgmtPDUTableCurrentLowCritical
outlet low critical current threshold (A x 10).
Set fails if value is higher than CurrentLowWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.103
pmPowerMgmtPDUTableEnergyValue
pdu energy value (Wh).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.3.1.105
pmPowerMgmtPDUTableEnergyStartTime
time at which energy calculation commenced (ISO8601 format).
Returns N/A if not applicable.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.3.1.106
pmPowerMgmtPDUTableEnergyReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.3.1.107
.1.3.6.1.4.1.10418.17.2.5.5 · 1 row entry · 41 columns
This table contains the information about outlets.
pmPowerMgmtOutletsTableEntry entry .1.3.6.1.4.1.10418.17.2.5.5.1
each entry has the information about the outlet.
Indexes
pmPowerMgmtOutletsTablePortNumber pmPowerMgmtOutletsTablePduNumber pmPowerMgmtOutletsTableNumber
Column Syntax OID
pmPowerMgmtOutletsTablePortNumber
Serial Port number.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.1
pmPowerMgmtOutletsTablePduNumber
Index.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.2
pmPowerMgmtOutletsTableNumber
Number of the outlet in the PDU.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.3
pmPowerMgmtOutletsTableName
Name of the outlet.
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.5.1.4
pmPowerMgmtOutletsTableStatus
Status of the outlet.
Returns 0 if not supported.
Enumeration
Enumerated Values:
1off
2on
3offLocked
4onLocked
5offCycle
6onPendingOff
7offPendingOn
8onPendingCycle
9notSet
10onFixed
11offShutdown
12tripped
.1.3.6.1.4.1.10418.17.2.5.5.1.5
pmPowerMgmtOutletsTablePowerControl
A set value of power*(2-6) will send command to PDU.
noAction(1) = always returned in a GET. Does nothing if SET.
powerOn(2) = when SET the power On command is sent to PDU.
powerOff(3) = when SET the power Off command …
Enumerationr/w
Enumerated Values:
1noAction
2powerOn
3powerOff
4powerCycle
5powerLock
6powerUnlock
.1.3.6.1.4.1.10418.17.2.5.5.1.6
pmPowerMgmtOutletsTablePortName
Serial Port Name where the PDU is connected.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.5.1.7
pmPowerMgmtOutletsTablePduId
PDU identification.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.5.1.8
pmPowerMgmtOutletsTablePostOnDelay
post on delay for the outlet (seconds x 10)
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.9
pmPowerMgmtOutletsTablePostOffDelay
post off delay for the outlet (seconds x 10)
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.10
pmPowerMgmtOutletsTableAlarm
Show the outlet alarm status.
Returns 0 if not supported.
Enumeration
Enumerated Values:
1normal
2blow-fuse
3hw-ocp
4high-critical
5high-warning
6low-warning
7low-critical
.1.3.6.1.4.1.10418.17.2.5.5.1.45
pmPowerMgmtOutletsTableCurrentValue
Actual value of current in the outlet (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.50
pmPowerMgmtOutletsTableCurrentMax
Maximum value of current in the outlet (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.51
pmPowerMgmtOutletsTableCurrentMin
Minimum value of current in the outlet (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.52
pmPowerMgmtOutletsTableCurrentAvg
Average value of current in the outlet (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.53
pmPowerMgmtOutletsTableCurrentReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.5.1.54
pmPowerMgmtOutletsTablePowerValue
Actual value of power in the outlet (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.60
pmPowerMgmtOutletsTablePowerMax
Maximum value of power in the outlet (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.61
pmPowerMgmtOutletsTablePowerMin
Minimum value of power in the outlet (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.62
pmPowerMgmtOutletsTablePowerAvg
Average value of power in the outlet (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.63
pmPowerMgmtOutletsTablePowerReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.5.1.64
pmPowerMgmtOutletsTablePowerType
Type of power values.
Returns 0 if not supported.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2measured
.1.3.6.1.4.1.10418.17.2.5.5.1.65
pmPowerMgmtOutletsTableVoltageValue
Actual value of voltage in the outlet (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.70
pmPowerMgmtOutletsTableVoltageMax
Maximum value of voltage in the outlet (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.71
pmPowerMgmtOutletsTableVoltageMin
Minimum value of voltage in the outlet (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.72
pmPowerMgmtOutletsTableVoltageAvg
Average value of voltage in the outlet (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.73
pmPowerMgmtOutletsTableVoltageReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.5.1.74
pmPowerMgmtOutletsTableVoltageType
Type of voltage values.
Returns 0 if not supported.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2measured
.1.3.6.1.4.1.10418.17.2.5.5.1.75
pmPowerMgmtOutletsTablePowerFactorValue
Actual value of power factor in the outlet (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.80
pmPowerMgmtOutletsTablePowerFactorMax
Maximum value of power factor in the outlet (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.81
pmPowerMgmtOutletsTablePowerFactorMin
Minimum value of power factor in the outlet (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.82
pmPowerMgmtOutletsTablePowerFactorAvg
Average value of power factor in the outlet (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.83
pmPowerMgmtOutletsTablePowerFactorReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.5.1.84
pmPowerMgmtOutletsTablePowerFactorType
Type of power factor values.
Returns 0 if not supported.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2measured
.1.3.6.1.4.1.10418.17.2.5.5.1.85
pmPowerMgmtOutletsTableCurrentHighCritical
outlet high critical (alarm) current threshold (A x 10).
Set fails if value is lower that CurrentHighWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.100
pmPowerMgmtOutletsTableCurrentHighWarning
outlet high warning current threshold (A x 10).
Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.101
pmPowerMgmtOutletsTableCurrentLowWarning
outlet low warning current threshold (A x 10).
Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.102
pmPowerMgmtOutletsTableCurrentLowCritical
outlet low critical current threshold (A x 10).
Set fails if value is higher than CurrentLowWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.103
pmPowerMgmtOutletsTableEnergyValue
outlet energy value (Wh).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.5.1.105
pmPowerMgmtOutletsTableEnergyStartTime
time at which energy calculation commenced (ISO8601 format).
Returns N/A if not applicable.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.5.1.106
pmPowerMgmtOutletsTableEnergyReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.5.1.107
.1.3.6.1.4.1.10418.17.2.5.7 · 1 row entry · 4 columns
This table contains the information about group of outlets.
pmPowerMgmtGroupTableEntry entry .1.3.6.1.4.1.10418.17.2.5.7.1
each entry has the information about group of outlets.
Indexes
pmPowerMgmtGroupTableIndex
Column Syntax OID
pmPowerMgmtGroupTableIndex
Index of the group.
IF-MIBInterfaceIndexOrZero
Textual Convention: IF-MIBInterfaceIndexOrZero Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.10418.17.2.5.7.1.1
pmPowerMgmtGroupTableName
Name of the group of outlets.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.7.1.2
pmPowerMgmtGroupTableStatus
Status of the group of outlet.
Enumeration
Enumerated Values:
1off
2on
.1.3.6.1.4.1.10418.17.2.5.7.1.3
pmPowerMgmtGroupTablePowerControl
A set value of power*(2-4) will send command to PDU.
noAction(1) = always returned in a GET. Does nothing if SET.
powerOn(2) = when SET the power On command is sent to PDU.
powerOff(3) = when SET the power Off command …
Enumerationr/w
Enumerated Values:
1noAction
2powerOn
3powerOff
4powerCycle
.1.3.6.1.4.1.10418.17.2.5.7.1.4
.1.3.6.1.4.1.10418.17.2.5.9 · 1 row entry · 34 columns
This table contains the information about phases.
pmPowerMgmtPhasesTableEntry entry .1.3.6.1.4.1.10418.17.2.5.9.1
each entry has the information about the phases.
Indexes
pmPowerMgmtPhasesTablePortNumber pmPowerMgmtPhasesTablePduNumber pmPowerMgmtPhasesTableNumber
Column Syntax OID
pmPowerMgmtPhasesTablePortNumber
Serial Port number.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.1
pmPowerMgmtPhasesTablePduNumber
Index.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.2
pmPowerMgmtPhasesTableNumber
Number of the phase in the PDU.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.3
pmPowerMgmtPhasesTableName
Name of the phase.
Returns N/A if not applicable.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.9.1.4
pmPowerMgmtPhasesTablePortName
Serial Port Name where the PDU is connected.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.9.1.5
pmPowerMgmtPhasesTablePduId
PDU identification.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.9.1.6
pmPowerMgmtPhasesTableAlarm
Show the phase alarm status.
Returns 0 if not supported.
Enumeration
Enumerated Values:
1normal
2blow-fuse
3hw-ocp
4high-critical
5high-warning
6low-warning
7low-critical
.1.3.6.1.4.1.10418.17.2.5.9.1.45
pmPowerMgmtPhasesTableCurrentValue
Actual value of current in the phase (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.50
pmPowerMgmtPhasesTableCurrentMax
Maximum value of current in the phase (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.51
pmPowerMgmtPhasesTableCurrentMin
Minimum value of current in the phase (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.52
pmPowerMgmtPhasesTableCurrentAvg
Average value of current in the phase (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.53
pmPowerMgmtPhasesTableCurrentReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.9.1.54
pmPowerMgmtPhasesTablePowerValue
Actual value of power in the phase (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.60
pmPowerMgmtPhasesTablePowerMax
Maximum value of power in the phase (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.61
pmPowerMgmtPhasesTablePowerMin
Minimum value of power in the phase (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.62
pmPowerMgmtPhasesTablePowerAvg
Average value of power in the phase (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.63
pmPowerMgmtPhasesTablePowerReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.9.1.64
pmPowerMgmtPhasesTablePowerType
Type of power values.
Returns 0 if not supported.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2measured
.1.3.6.1.4.1.10418.17.2.5.9.1.65
pmPowerMgmtPhasesTableVoltageValue
Actual value of voltage in the phase (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.70
pmPowerMgmtPhasesTableVoltageMax
Maximum value of voltage in the phase (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.71
pmPowerMgmtPhasesTableVoltageMin
Minimum value of voltage in the phase (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.72
pmPowerMgmtPhasesTableVoltageAvg
Average value of voltage in the phase (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.73
pmPowerMgmtPhasesTableVoltageReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.9.1.74
pmPowerMgmtPhasesTableVoltageType
Type of voltage values.
Returns 0 if not supported.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2measured
.1.3.6.1.4.1.10418.17.2.5.9.1.75
pmPowerMgmtPhasesTablePowerFactorValue
Actual value of power factor in the phase (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.80
pmPowerMgmtPhasesTablePowerFactorMax
Maximum value of power factor in the phase (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.81
pmPowerMgmtPhasesTablePowerFactorMin
Minimum value of power factor in the phase (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.82
pmPowerMgmtPhasesTablePowerFactorAvg
Average value of power factor in the phase (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.83
pmPowerMgmtPhasesTablePowerFactorReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.9.1.84
pmPowerMgmtPhasesTablePowerFactorType
Type of power factor values.
Returns 0 if not supported.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2measured
.1.3.6.1.4.1.10418.17.2.5.9.1.85
pmPowerMgmtPhasesTableCurrentHighCritical
phase high critical (alarm) current threshold (A x 10).
Set fails if value is lower that CurrentHighWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.100
pmPowerMgmtPhasesTableCurrentHighWarning
phase high warning current threshold (A x 10).
Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.101
pmPowerMgmtPhasesTableCurrentLowWarning
phase low warning current threshold (A x 10).
Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.102
pmPowerMgmtPhasesTableCurrentLowCritical
phase low critical current threshold (A x 10).
Set fails if value is higher than CurrentLowWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.9.1.103
.1.3.6.1.4.1.10418.17.2.5.11 · 1 row entry · 37 columns
This table contains the information about banks.
pmPowerMgmtBanksTableEntry entry .1.3.6.1.4.1.10418.17.2.5.11.1
each entry has the information about the banks.
Indexes
pmPowerMgmtBanksTablePortNumber pmPowerMgmtBanksTablePduNumber pmPowerMgmtBanksTableNumber
Column Syntax OID
pmPowerMgmtBanksTablePortNumber
Serial Port number.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.1
pmPowerMgmtBanksTablePduNumber
Index.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.2
pmPowerMgmtBanksTableNumber
Number of the bank in the PDU.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.3
pmPowerMgmtBanksTableName
Name of the bank.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.11.1.4
pmPowerMgmtBanksTablePortName
Serial Port Name where the PDU is connected.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.11.1.5
pmPowerMgmtBanksTablePduId
PDU identification.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.11.1.6
pmPowerMgmtBanksTableAlarm
Show the bank alarm status.
Returns 0 if not supported.
Enumeration
Enumerated Values:
1normal
2blow-fuse
3hw-ocp
4high-critical
5high-warning
6low-warning
7low-critical
.1.3.6.1.4.1.10418.17.2.5.11.1.45
pmPowerMgmtBanksTableCurrentValue
Actual value of current in the bank (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.50
pmPowerMgmtBanksTableCurrentMax
Maximum value of current in the bank (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.51
pmPowerMgmtBanksTableCurrentMin
Minimum value of current in the bank (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.52
pmPowerMgmtBanksTableCurrentAvg
Average value of current in the bank (A x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.53
pmPowerMgmtBanksTableCurrentReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.11.1.54
pmPowerMgmtBanksTablePowerValue
Actual value of power in the bank (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.60
pmPowerMgmtBanksTablePowerMax
Maximum value of power in the bank (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.61
pmPowerMgmtBanksTablePowerMin
Minimum value of power in the bank (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.62
pmPowerMgmtBanksTablePowerAvg
Average value of power in the bank (W x 10).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.63
pmPowerMgmtBanksTablePowerReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.11.1.64
pmPowerMgmtBanksTablePowerType
Type of power values.
Returns 0 if not supported.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2measured
.1.3.6.1.4.1.10418.17.2.5.11.1.65
pmPowerMgmtBanksTableVoltageValue
Actual value of voltage in the bank (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.70
pmPowerMgmtBanksTableVoltageMax
Maximum value of voltage in the bank (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.71
pmPowerMgmtBanksTableVoltageMin
Minimum value of voltage in the bank (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.72
pmPowerMgmtBanksTableVoltageAvg
Average value of voltage in the bank (V).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.73
pmPowerMgmtBanksTableVoltageReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.11.1.74
pmPowerMgmtBanksTableVoltageType
Type of voltage values.
Returns 0 if not supported.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2measured
.1.3.6.1.4.1.10418.17.2.5.11.1.75
pmPowerMgmtBanksTablePowerFactorValue
Actual value of power factor in the bank (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.80
pmPowerMgmtBanksTablePowerFactorMax
Maximum value of power factor in the bank (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.81
pmPowerMgmtBanksTablePowerFactorMin
Minimum value of power factor in the bank (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.82
pmPowerMgmtBanksTablePowerFactorAvg
Average value of power factor in the bank (Pf x 100).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.83
pmPowerMgmtBanksTablePowerFactorReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.11.1.84
pmPowerMgmtBanksTablePowerFactorType
Type of power factor values.
Returns 0 if not supported.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2measured
.1.3.6.1.4.1.10418.17.2.5.11.1.85
pmPowerMgmtBanksTableCurrentHighCritical
bank high critical (alarm) current threshold (A x 10).
Set fails if value is lower that CurrentHighWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.100
pmPowerMgmtBanksTableCurrentHighWarning
bank high warning current threshold (A x 10).
Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.101
pmPowerMgmtBanksTableCurrentLowWarning
bank low warning current threshold (A x 10).
Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.102
pmPowerMgmtBanksTableCurrentLowCritical
bank low critical current threshold (A x 10).
Set fails if value is higher than CurrentLowWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.103
pmPowerMgmtBanksTableEnergyValue
bank energy value (Wh).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.11.1.105
pmPowerMgmtBanksTableEnergyStartTime
time at which energy calculation commenced (ISO8601 format).
Returns N/A if not applicable.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.11.1.106
pmPowerMgmtBanksTableEnergyReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.11.1.107
.1.3.6.1.4.1.10418.17.2.5.13 · 1 row entry · 30 columns
This table contains the information about sensors.
pmPowerMgmtSensorsTableEntry entry .1.3.6.1.4.1.10418.17.2.5.13.1
each entry has the information about the sensors.
Indexes
pmPowerMgmtSensorsTablePortNumber pmPowerMgmtSensorsTablePduNumber pmPowerMgmtSensorsTableNumber
Column Syntax OID
pmPowerMgmtSensorsTablePortNumber
Serial Port number.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.1
pmPowerMgmtSensorsTablePduNumber
Index.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.2
pmPowerMgmtSensorsTableNumber
Number of the sensor in the PDU.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.3
pmPowerMgmtSensorsTableName
Name of the sensor.
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.13.1.4
pmPowerMgmtSensorsTablePortName
Serial Port Name where the PDU is connected.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.13.1.5
pmPowerMgmtSensorsTablePduId
PDU identification.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.13.1.6
pmPowerMgmtSensorsTableType
The type of environmental monitor.
Returns 0 if not supported.
Enumeration
Enumerated Values:
1temp-internal
2temperature
3humidity
4air-flow
5smoke
6dry-concact
7water-level
8motion
9unplugged
10unknown
.1.3.6.1.4.1.10418.17.2.5.13.1.7
pmPowerMgmtSensorsTableStatus
Status of digital sensors: Dry-Contact, Water level, Smoke sensor, Motion sensor.
Returns 0 if not supported.
Enumeration
Enumerated Values:
1normal
2triggered
3not-applicable
4opened
5closed
.1.3.6.1.4.1.10418.17.2.5.13.1.8
pmPowerMgmtSensorsTableValue
Actual value of the sensor.
Returns N/A if not applicable.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.13.1.20
pmPowerMgmtSensorsTableValueMax
Maximum value of the sensor.
Returns N/A if not applicable.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.13.1.21
pmPowerMgmtSensorsTableValueMin
Minimum value of the sensor.
Returns N/A if not applicable.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.13.1.22
pmPowerMgmtSensorsTableValueAvg
Average value of the sensor.
Returns N/A if not applicable.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.17.2.5.13.1.23
pmPowerMgmtSensorsTableValueInt
Actual value of the sensor.
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.25
pmPowerMgmtSensorsTableValueMaxInt
Maximum value of the sensor.
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.26
pmPowerMgmtSensorsTableValueMinInt
Minimum value of the sensor.
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.27
pmPowerMgmtSensorsTableValueAvgInt
Average value of the sensor.
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.28
pmPowerMgmtSensorsTableValueReset
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to sensor.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.17.2.5.13.1.30
pmPowerMgmtSensorsTableHighCritical
sensor high critical (alarm) threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
Set fails if value is lower that CurrentHighWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.40
pmPowerMgmtSensorsTableHighWarning
sensor high warning threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
Set fails if value is higher than HighCritical or lower than LowWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.41
pmPowerMgmtSensorsTableLowWarning
sensor low warning threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
Set fails if value is higher than HighWarning or lower than LowCritical.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.42
pmPowerMgmtSensorsTableLowCritical
sensor low critical threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
Set fails if value is higher than LowWarning.
Returns 0 if not supported.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.43
pmPowerMgmtSensorsTableUnit
sensor unit.
Returns 0 if not supported.
Enumerationr/w
Enumerated Values:
1undefined
2fahrenheit
3celsius
4percent
5afu
.1.3.6.1.4.1.10418.17.2.5.13.1.45
pmPowerMgmtSensorsTableHighCriticalC
sensor high critical (alarm) threshold (Celcius x 10).
to SET: use pmPowerMgmtSensorsTableHighCritical in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.50
pmPowerMgmtSensorsTableHighWarningC
sensor high warning threshold (Celcius x 10).
to SET: use pmPowerMgmtSensorsTableHighWarning in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.51
pmPowerMgmtSensorsTableLowWarningC
sensor low warning threshold (Celcius x 10).
to SET: use pmPowerMgmtSensorsTableLowWarning in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.52
pmPowerMgmtSensorsTableLowCriticalC
sensor low critical threshold (Celcius x 10).
to SET: use pmPowerMgmtSensorsTableLowCritical in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.53
pmPowerMgmtSensorsTableHighCriticalF
sensor high critical (alarm) threshold (Fahrenheit x 10).
to SET: use pmPowerMgmtSensorsTableHighCritical in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.60
pmPowerMgmtSensorsTableHighWarningF
sensor high warning threshold (Fahrenheit x 10).
to SET: use pmPowerMgmtSensorsTableHighWarning in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.61
pmPowerMgmtSensorsTableLowWarningF
sensor low warning threshold (Fahrenheit x 10).
to SET: use pmPowerMgmtSensorsTableLowWarning in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.62
pmPowerMgmtSensorsTableLowCriticalF
sensor low critical threshold (Fahrenheit x 10).
to SET: use pmPowerMgmtSensorsTableLowCritical in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.17.2.5.13.1.63