pmPowerMgmtOutletsTableCurrentHighWarning
PM-MIB ·
.1.3.6.1.4.1.10418.17.2.5.5.1.101
Object
outlet high warning current threshold (A x 10). Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning. Returns 0 if not supported.
Context
- MIB
- PM-MIB
- OID
.1.3.6.1.4.1.10418.17.2.5.5.1.101- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- pmPowerMgmtOutletsTableEntry
- Table
- pmPowerMgmtOutletsTable
- Siblings
- 40
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pmPowerMgmtOutletsTablePortNumber Serial Port number. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.10418.17.2.5.5.1.1 |
| pmPowerMgmtOutletsTablePostOffDelay post off delay for the outlet (seconds x 10)
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.10 |
| pmPowerMgmtOutletsTableCurrentHighCritical outlet high critical (alarm) current threshold (A x 10).
Set fails if value is lower that CurrentHighWarning.
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.100 |
| pmPowerMgmtOutletsTableCurrentLowWarning outlet low warning current threshold (A x 10).
Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.102 |
| pmPowerMgmtOutletsTableCurrentLowCritical outlet low critical current threshold (A x 10).
Set fails if value is higher than CurrentLowWarning.
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.103 |
| pmPowerMgmtOutletsTableEnergyValue outlet energy value (Wh).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.105 |
| pmPowerMgmtOutletsTableEnergyStartTime time at which energy calculation commenced (ISO8601 format).
Returns N/A if not applicable. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.17.2.5.5.1.106 |
| pmPowerMgmtOutletsTableEnergyReset noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU. | column | Enumeration | .1.3.6.1.4.1.10418.17.2.5.5.1.107 |
| pmPowerMgmtOutletsTablePduNumber Index. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.10418.17.2.5.5.1.2 |
| pmPowerMgmtOutletsTableNumber Number of the outlet in the PDU. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.10418.17.2.5.5.1.3 |
| pmPowerMgmtOutletsTableName Name of the outlet. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.17.2.5.5.1.4 |
| pmPowerMgmtOutletsTableAlarm Show the outlet alarm status.
Returns 0 if not supported. | column | Enumeration | .1.3.6.1.4.1.10418.17.2.5.5.1.45 |
| pmPowerMgmtOutletsTableStatus Status of the outlet.
Returns 0 if not supported. | column | Enumeration | .1.3.6.1.4.1.10418.17.2.5.5.1.5 |
| pmPowerMgmtOutletsTableCurrentValue Actual value of current in the outlet (A x 10).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.50 |
| pmPowerMgmtOutletsTableCurrentMax Maximum value of current in the outlet (A x 10).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.51 |
| pmPowerMgmtOutletsTableCurrentMin Minimum value of current in the outlet (A x 10).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.52 |
| pmPowerMgmtOutletsTableCurrentAvg Average value of current in the outlet (A x 10).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.53 |
| pmPowerMgmtOutletsTableCurrentReset noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU. | column | Enumeration | .1.3.6.1.4.1.10418.17.2.5.5.1.54 |
| pmPowerMgmtOutletsTablePowerControl A set value of power*(2-6) will send command to PDU.
noAction(1) = always returned in a GET. Does nothing if SET.
powerOn(2) = when SET the power On command is sent to PDU.
power… | column | Enumeration | .1.3.6.1.4.1.10418.17.2.5.5.1.6 |
| pmPowerMgmtOutletsTablePowerValue Actual value of power in the outlet (W x 10).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.60 |
| pmPowerMgmtOutletsTablePowerMax Maximum value of power in the outlet (W x 10).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.61 |
| pmPowerMgmtOutletsTablePowerMin Minimum value of power in the outlet (W x 10).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.62 |
| pmPowerMgmtOutletsTablePowerAvg Average value of power in the outlet (W x 10).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.63 |
| pmPowerMgmtOutletsTablePowerReset noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU. | column | Enumeration | .1.3.6.1.4.1.10418.17.2.5.5.1.64 |
| pmPowerMgmtOutletsTablePowerType Type of power values.
Returns 0 if not supported. | column | Enumeration | .1.3.6.1.4.1.10418.17.2.5.5.1.65 |
| pmPowerMgmtOutletsTablePortName Serial Port Name where the PDU is connected. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.17.2.5.5.1.7 |
| pmPowerMgmtOutletsTableVoltageValue Actual value of voltage in the outlet (V).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.70 |
| pmPowerMgmtOutletsTableVoltageMax Maximum value of voltage in the outlet (V).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.71 |
| pmPowerMgmtOutletsTableVoltageMin Minimum value of voltage in the outlet (V).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.72 |
| pmPowerMgmtOutletsTableVoltageAvg Average value of voltage in the outlet (V).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.73 |
| pmPowerMgmtOutletsTableVoltageReset noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU. | column | Enumeration | .1.3.6.1.4.1.10418.17.2.5.5.1.74 |
| pmPowerMgmtOutletsTableVoltageType Type of voltage values.
Returns 0 if not supported. | column | Enumeration | .1.3.6.1.4.1.10418.17.2.5.5.1.75 |
| pmPowerMgmtOutletsTablePduId PDU identification. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10418.17.2.5.5.1.8 |
| pmPowerMgmtOutletsTablePowerFactorValue Actual value of power factor in the outlet (Pf x 100).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.80 |
| pmPowerMgmtOutletsTablePowerFactorMax Maximum value of power factor in the outlet (Pf x 100).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.81 |
| pmPowerMgmtOutletsTablePowerFactorMin Minimum value of power factor in the outlet (Pf x 100).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.82 |
| pmPowerMgmtOutletsTablePowerFactorAvg Average value of power factor in the outlet (Pf x 100).
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.83 |
| pmPowerMgmtOutletsTablePowerFactorReset noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU. | column | Enumeration | .1.3.6.1.4.1.10418.17.2.5.5.1.84 |
| pmPowerMgmtOutletsTablePowerFactorType Type of power factor values.
Returns 0 if not supported. | column | Enumeration | .1.3.6.1.4.1.10418.17.2.5.5.1.85 |
| pmPowerMgmtOutletsTablePostOnDelay post on delay for the outlet (seconds x 10)
Returns 0 if not supported. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10418.17.2.5.5.1.9 |