.1.3.6.1.4.1.2011.6.21.1.1.1.1 · 1 row entry · 5 columns
Table of the test group:
It provides the number of the test group to which a shelf of the device corresponds.
It is uniquely identified by the number of the test group. Multiple shelves can share
a test board.
A test group corresponds to a test board. The number of a test group is the same as
the number of the shelf that houses the test board to which the test group corresponds.
The index of this table is hwTestGroupNo.
hwTestGroupOprEntry entry .1.3.6.1.4.1.2011.6.21.1.1.1.1.1
Table of the test group:
It provides the number of the test group to which a shelf of the device corresponds.
It is uniquely identified by the number of the test group. Multiple shelves can share
a test board.
A test gr…
Indexes
hwTestGroupNo
Column Syntax OID
hwTestGroupNo
Test group number. The MD5500 supports the number that ranges from 0 to 240.
The MA5100 supports the number that ranges from 0 to 4.
The MA5300 supports the number that ranges from 0 to 63.
Integer32
Constraints:
range: 0-240
.1.3.6.1.4.1.2011.6.21.1.1.1.1.1.1
hwTestBoardIfIndex
Test board IfIndex.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.1.1.2
hwTestGroupAssistIfIndex
TestGroupAssist port IfIndex.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.1.1.3
hwTestGroupAssistTelNo
Assistant telephone number.
The maximum length is 16 Octets.
OctetStringr/w
Constraints:
range: 0-16
.1.3.6.1.4.1.2011.6.21.1.1.1.1.1.4
hwTestGroupRowStatus
Present operation status of a row.
Options:
1. active(1), -the present operation status of the row is active
2. notInService(2), -the present operation status of the row is notInService
3. notReady(3), -th…
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.2011.6.21.1.1.1.1.1.5
.1.3.6.1.4.1.2011.6.21.1.1.1.2 · 1 row entry · 226 columns
This table is used for enabling a subscriber line test and obtaining the test result
after a test is complete. The subscriber line test function can be used for obtaining 
the performance information about a subscriber line, such as capacity and resistance. 
Users can learn about the conditions of the line by comparing such information with
standard data.
The index of this table is ifindex.
hwLoopLineTestOprEntry entry .1.3.6.1.4.1.2011.6.21.1.1.1.2.1
This table is used for enabling a subscriber line test and obtaining the test result
after a test is complete. The subscriber line test function can be used for obtaining
the performance information about a subscriber …
Indexes
IF-MIBifIndex
Column Syntax OID
hwLoopLineTestOprType
MELT operation type
Options:
1. stop(1) -stop a MELT test
2. start(2) -start a MELT test
3. invalid(-1) -invalid value
Enumerationr/w
Enumerated Values:
-1invalid
1stop
2start
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.1
hwLoopLineTestVoltage
Indicates whether a voltage exists on the line under test.
Options:
1. notest(1) -the voltage does not exist on the line under test
2. test(2) -the voltage exists on the line under test
3. invalid(-1) -invalid va…
Enumerationr/w
Enumerated Values:
-1invalid
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.2
hwLoopLineTestResistance
Indicates whether resistance exists on the line under test.
Options:
1. notest(1) -resistance does not exist on the line under test
2. test(2) -resistance exists on the line under test
3. invalid(-1) -invalid val…
Enumerationr/w
Enumerated Values:
-1invalid
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.3
hwLoopLineTestCapacitance
Indicates whether capacitance exists on the line under test.
Options:
1. notest(1) -capacitance does not exist on the line under test
2. test(2) -capacitance exists on the line under test
3. invalid(-1) -invalid …
Enumerationr/w
Enumerated Values:
-1invalid
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.4
hwLoopLineTestLoopResistance
Indicates whether loop resistance exists on the line under test.
Options:
1. notest(1) -loop resistance does not exist on the line under test
2. test(2) -loop resistance exists on the line under test
3. invalid(-…
Enumerationr/w
Enumerated Values:
-1invalid
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.5
hwLoopLineTestPoleResistance
Indicates whether pole resistance exists on the line under test.
Options:
1. notest(1) -Pole resistance does not exist on the line under test
2. test(2) -Pole resistance exists on the line under test
3. invalid(-…
Enumerationr/w
Enumerated Values:
-1invalid
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.6
hwLoopLineTestBusyProcFlag
Identify whether to start a test when the line is busy. The system will excecute a corresponding
operation according to the configuration that a user specifies, for example, to cancel the test or to force to test.
Opti…
Enumerationr/w
Enumerated Values:
-1invalid
1busyNoTest
2busyTest
3busystrenTest
4deferredTest
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.7
hwLoopLineTestStatus
Indicates the result of MELT test.
Options:
1. normal(1) -the MELT test is successful
2. testFail(2) -the MELT test fails
3. portBusy(3) -the MELT test port is busy
4. testOutOfTime(4) …
Enumeration
Enumerated Values:
-1invalid
1normal
2testFail
3portBusy
4testOutOfTime
5testingAbnormal
6broadbandtesting
7capturefail
8notratb
9testcanceled
10testNotSupport
11meltChipFaulty
12meltChipCheckInProcess
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.8
hwLoopLineTestConclusion
MELT test conclusion, this object is for pots and combo board's port.
Options:
1. normal(1) -the test conclusion is normal
2. meetLine(2) -the test conclusion is meetLine
3. aLineMix(3…
Enumeration
Enumerated Values:
-1invalid
1normal
2meetLine
3aLineMix
4bLineMix
5doubleMix
6aLineEarth
7bLineEarth
8doublelineearth
9selfMix
10abLine
11aLineFree
12bLineEarthFree
13doubleLineEarthFree
14abLineFree
15killLine
16noPutDownTele
17unknow
18selfMixinMDF
19selfMixoutMDF
20cutLineinMDF
21cutLineoutMDF
30dCvoltagePowerFeed
31aCvoltageRinging
32dCvoltageOffhook
33dCvoltage
34aCvoltage
35abImpedance
36baImpedance
37agImpedance
38bgImpedance
39agACCurrent
41bgACCurrent
42abACCurrent
43agDCCurrent
44bgDCCurrent
45abDCCurrent
46loopCurrent
47noise
91abRFaultId
92aRFaultId
93bRFaultId
94abLeakId
95aLeakId
96bLeakId
97abFvacLevelH
98aFvacLevelH
99bFvacLevelH
100abFvacLevelI
101aFvacLevelI
102bFvacLevelI
103abFvacLevelO
104aFvacLevelO
105bFvacLevelO
106abFvDcLevelH
107aFvDcLevelH
108bFvDcLevelH
109abFvDcLevelI
110aFvDcLevelI
111bFvDcLevelI
112abFvDcLevelO
113aFvDcLevelO
114bFvDcLevelO
115fesIdPPA
116fesIdPPAInv
117fesId2PPA
118fesId2PPAInv
119etsiXdslSignature
120fetIdEr
121abreak
122bbreak
123abreakInMDF
124bbreakInMDF
125abreakOutMDF
126bbreakOutMDF
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.9
hwLoopLineTestACAG
Indicates the A->ground AC voltage.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.10
hwLoopLineTestACBG
Indicates the B->ground AC voltage.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.11
hwLoopLineTestACAB
Indicates the A->B AC voltage.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.12
hwLoopLineTestDCAG
Indicates the A->ground DC voltage.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.13
hwLoopLineTestDCBG
Indicates the B->ground DC voltage.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.14
hwLoopLineTestDCAB
Indicates the A->B DC voltage.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.15
hwLoopLineTestRAG
Indicates the A->ground insulation resistance.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.16
hwLoopLineTestRBG
Indicates the B->ground insulation resistance.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.17
hwLoopLineTestRAB
Indicates the A->B insulation resistance.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.18
hwLoopLineTestCapAG
Indicates the A->ground capacitance.
Unit: nF
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.19
hwLoopLineTestCapBG
Indicates the B->ground capacitance.
Unit: nF
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.20
hwLoopLineTestCapAB
Indicates the A->B capacitance.
Unit: nF
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.21
hwLoopLineTestLR
Indicates the loop resistance.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.22
hwLoopLineTestRABResPole
Indicates the A->B polarity reversal resistance.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.23
hwLoopLineTestMSocket
Indicates the M-socket connection.
Options:
1. notconnected(1) -the M-socket is not connected
2. connected(2) -the M-socket is connected
3. aBReversed(3) -the wire A and wire B are reversed
Enumeration
Enumerated Values:
1notconnected
2connected
3aBReversed
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.24
hwLoopLineTestBtssPowerProcFlag
Loop line test-BTSS line with power processing.
Options:
1. noTest(1) -not test
2. test(2) -test
3. invalid(-1) -invalid value
Enumerationr/w
Enumerated Values:
-1invalid
1noTest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.25
hwLoopLineTestImpedance
Loop line test-impedance.
Options:
1. notest(1) -not test
2. test(2) -test
Enumerationr/w
Enumerated Values:
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.26
hwLoopLineTestImpedanceAB
A->B impedance (unit: ohm)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.27
hwLoopLineTestImpedanceBA
B->A impedance (unit: ohm)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.28
hwLoopLineTestImpedanceAG
A->ground impedance (unit: ohm)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.29
hwLoopLineTestImpedanceBG
B->ground impedance (unit: ohm)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.30
hwLoopLineTestCurrent
Loop line test-current.
Options:
1. notest(1) -not test
2. test(2) -test
Enumerationr/w
Enumerated Values:
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.31
hwLoopLineTestACCurrentAG
A->ground AC current (unit: mA)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.32
hwLoopLineTestACCurrentBG
B->ground AC current (unit: mA)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.33
hwLoopLineTestACCurrentAB
AB AC current (unit: mA)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.34
hwLoopLineTestDCCurrentAG
A->ground DC current (unit: mA)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.35
hwLoopLineTestDCCurrentBG
B->ground DC current (unit: mA)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.36
hwLoopLineTestDCCurrentAB
AB DC current (unit: mA)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.37
hwLoopLineTestLoopCurrent
Loop line test-loop current.
Options:
1. notest(1) -not test
2. test(2) -test
Enumerationr/w
Enumerated Values:
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.38
hwLoopLineTestLC
Loop current (unit: uA)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.39
hwLoopLineTestNoise
Loop line test-noise.
Options:
1. notest(1) -not test
2. test(2) -test
Enumerationr/w
Enumerated Values:
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.40
hwLoopLineTestN
Noise (unit: dBm)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.41
hwLoopLineTestPPA
Indicates whether PPA exists on the line under test.
Options:
1. notest(1) -PPA does not exist on the line under test
2. test(2) -PPA exists on the line under test
3. invalid(-1) -invalid value
Default: notest(1)
Enumerationr/w
Enumerated Values:
-1invalid
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.42
hwLoopLineTestPPAResult
Indicates whether the PPA exists.
Options:
1. noexist(1) -PPA does not exist
2. exist(2) -PPA exists
3. inverseexist(3) -PPA inverse exists
4. invalid(-1) -invalid value
Enumeration
Enumerated Values:
-1invalid
1noexist
2exist
3inverseexist
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.43
hwLoopLineTestDeferredTime
Indicates the deferred time.
Unit: minute
This leaf is valid only when the value of hwLoopLineTestBusyProcFlag is DeferredTest(4).
Default: 30
Integer32r/w
Constraints:
range: -1--1
range: 1-1440
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.44
hwLoopLineTestTimeoutProc
Indicates the timeout processing.
Options:
1. notest(1) -if the deferred time times out and the port is still busy
the test will be canceled
2. test(2) -if the deferred time times out and the po…
Enumerationr/w
Enumerated Values:
-1invalid
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.45
hwLoopLineTestReverse
Reverse flag (0:normal test 1:reverse test)
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.46
hwLoopLineTestUtgAcFreq
Frequency of foreign AC voltage source coupled to tip via Zbat_tip impedance.
Unit: Hz
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.47
hwLoopLineTestUrgAcFreq
Frequency of foreign AC voltage source coupled to ring via Zbat_ring impedance.
Unit:Hz
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.48
hwLoopLineTestUtrAcFreq
Frequency of foreign AC voltage source coupled to tip-ring via Zbat_tipring impedance.
Unit:Hz
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.49
hwLoopLineTestItipAc
AC foreign current on the tip wire.
Unit:uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.50
hwLoopLineTestIringAc
AC foreign current on the ring wire.
Unit:uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.51
hwLoopLineTestItipDc
DC foreign current on the tip wire.
Unit:uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.52
hwLoopLineTestIringDc
DC foreign current on the ring wire.
Unit:uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.53
hwLoopLineTestRbattip
In presence of a foreign voltage, the equivalent coupling resistance of wire A.
Unit:ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.54
hwLoopLineTestRbatring
In presence of a foreign voltage, the equivalent coupling resistance of wire B.
Unit:ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.55
hwLoopLineTestRring
Resistance in series with the ring capacitance, for example
when a ringer load or a passive R-C signature terminates the loop.
It also includes the cable resistance R line but it does not include
the 24 kohm feeding r…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.56
hwLoopLineTestCsig
Capacitance of an xDSL signal.
Unit: nF
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.57
hwLoopLineTestVzener
Zener diode threshold in the case of an off-hook phone.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.58
hwLoopLineTestRzener
DC tip-ring resistance measured in the case of an off-hook phone.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.59
hwLoopLineTestGtg
Aggregate a->ground conductance.
Unit: nS
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.60
hwLoopLineTestBtg
Aggregate a->ground susceptance.
Unit: nS
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.61
hwLoopLineTestGrg
Aggregate b->ground conductance.
Unit: nS
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.62
hwLoopLineTestBrg
Aggregate b->ground susceptance.
Unit: nS
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.63
hwLoopLineTestGtr
Aggregate a->b conductance.
Unit: nS
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.64
hwLoopLineTestBtr
Aggregate a->b susceptance.
Unit: nS
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.65
hwLoopLineTestSIGN
Indicates the ETSI xDSL Signature is detected or not.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.66
hwLoopLineTestACFEM
Indicates the presence of an AC foreign voltage above the threshold defined by ACFEMmin.
By reading the results of the foreign voltage test, it is possible to determine
whether the foreign electromotive force source h…
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.67
hwLoopLineTestDCFEM
Indicates the presence of a DC foreign voltage above the threshold defined
by DCFEMmin. By reading the results of the foreign voltage test,
it is possible to determine whether the foreign electromotive
force source ha…
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.68
hwLoopLineTestONHK
Indicates the presens of a phone in the on-hook state.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.69
hwLoopLineTestOPEN
Indicates a->b resistance exceeds the threshold.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.70
hwLoopLineTestSHORT
Indicates that the insulation resistance is small.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.71
hwLoopLineTestROH
Indicates a phone in the off-hook state.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.72
hwLoopLineTestUtgDcUp
Indicates the a->ground highest measurement DC voltage.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.73
hwLoopLineTestUtgDcDown
Indicates the a->ground lowest measurement DC voltage.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.74
hwLoopLineTestUrgDcUp
Indicates the b->ground highest measurement DC voltage.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.75
hwLoopLineTestUrgDcDown
Indicates the b->ground lowest measurement DC voltage.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.76
hwLoopLineTestUtrPos
Indicates the a->b positive measurement DC voltage.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.77
hwLoopLineTestUtrNeg
Indicates the b->a measurement DC voltage.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.78
hwLoopLineTestItgDcUp
Indicates the current mapping the A-wire highest voltage for test.
Unit: uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.79
hwLoopLineTestItgDcDown
Indicates the current mapping the A-wire lowest voltage for test.
Unit: uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.80
hwLoopLineTestIrgDcUp
Indicates the current mapping the B-wire highest voltage for test.
Unit: uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.81
hwLoopLineTestIrgDcDown
Indicates the current mapping the B-wire lowest voltage for test.
Unit: uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.82
hwLoopLineTestItrPos
Indicates the current mapping the A->B positive voltage for test.
Unit: uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.83
hwLoopLineTestItrNeg
Indicates the current mapping the A->B negative voltage for test.
Unit: uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.84
hwLoopLineTestRinger
Indicates the detected ringer.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.85
hwLoopLineTestPPARes
Indicates the resistance of PPA.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.86
hwLoopLineTestStartTime
Indicates the start time and date of the MELT test.
SNMPv2-TCDateAndTime
Textual Convention: SNMPv2-TCDateAndTime OctetString
Type Constraints:
range: 8
range: 11
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.87
hwLoopLineTestEndTime
Indicates the end time and date of the MELT test.
SNMPv2-TCDateAndTime
Textual Convention: SNMPv2-TCDateAndTime OctetString
Type Constraints:
range: 8
range: 11
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.88
hwLoopLineTestOprMeasuredFreq
Indicates the measured frequency for complex impedance.
Options:
1. frequency25Hz(0) -25 Hz
2. frequency275Hz(1) -275 Hz
3. invalid(-1) -invalid value
Default: frequency25Hz(0)
Enumerationr/w
Enumerated Values:
-1invalid
0frequency25Hz
1frequency275Hz
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.89
hwLoopLineTestIfIndex
Port IfIndex.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.90
hwLoopLineTestRequestID
Request ID.
The value is the fourth parameter in the trap message.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.91
hwLoopLineTestRABPole
Indicates the A->B polarity resistance.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.92
hwLoopLineTestACAGFlag
Indicates whether the value of hwLoopLineTestACAG is valid.
Options:
1. valid(1) -the value of hwLoopLineTestACAG is valid
2. invalid(2) -the value of hwLoopLineTestACAG is invalid
3. notsupport(3) -the valu…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.93
hwLoopLineTestACBGFlag
Indicates whether the value of hwLoopLineTestACBG is valid.
Options:
1. valid(1) -the value of hwLoopLineTestACBG is valid
2. invalid(2) -the value of hwLoopLineTestACBG is invalid
3. notsupport(3) -the value of hwL…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.94
hwLoopLineTestACABFlag
Indicates whether the value of hwLoopLineTestACAB is valid.
Options:
1. valid(1) -the value of hwLoopLineTestACAB is valid
2. invalid(2) -the value of hwLoopLineTestACAB is invalid
3. notsupport(3) -the valu…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.95
hwLoopLineTestDCAGFlag
Indicates whether the value of hwLoopLineTestDCAG is valid.
Options:
1. valid(1) -the value of hwLoopLineTestDCAG is valid
2. invalid(2) -the value of hwLoopLineTestDCAG is invalid
3. notsupport(3) -the value…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.96
hwLoopLineTestDCBGFlag
Indicates whether the value of hwLoopLineTestDCBG is valid.
Options:
1. valid(1) -the value of hwLoopLineTestDCBG is valid
2. invalid(2) -the value of hwLoopLineTestDCBG is invalid
3. notsupport(3) -the valu…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.97
hwLoopLineTestDCABFlag
Indicates whether the value of hwLoopLineTestDCAB is valid.
Options:
1. valid(1) -the value of hwLoopLineTestDCAB is valid
2. invalid(2) -the value of hwLoopLineTestDCAB is invalid
3. notsupport(3) -the valu…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.98
hwLoopLineTestRAGFlag
Indicates whether the value of hwLoopLineTestRAG is valid.
Options:
1. valid(1) -the value of hwLoopLineTestRAG is valid
2. invalid(2) -the value of hwLoopLineTestRAG is invalid
3. notsupport(3) -the value o…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.99
hwLoopLineTestRBGFlag
Indicates whether the value of hwLoopLineTestRBG is valid.
Options:
1. valid(1) -the value of hwLoopLineTestRBG is valid
2. invalid(2) -the value of hwLoopLineTestRBG is invalid
3. notsupport(3) -the value o…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.100
hwLoopLineTestRABFlag
Indicates whether the value of hwLoopLineTestRAB is valid.
Options:
1. valid(1) -the value of hwLoopLineTestRAB is valid
2. invalid(2) -the value of hwLoopLineTestRAB is invalid
3. notsupport(3) -the value of…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.101
hwLoopLineTestRABPoleFlag
Indicates whether the value of hwLoopLineTestRABPole is valid.
Options:
1. valid(1) -the value of hwLoopLineTestRABPole is valid
2. invalid(2) -the value of hwLoopLineTestRABPole is invalid
3. notsupport(3) -…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.102
hwLoopLineTestRABResPoleFlag
Indicates whether the value of hwLoopLineTestRABResPole is valid.
Options:
1. valid(1) -the value of hwLoopLineTestRABResPole is valid
2. invalid(2) -the value of hwLoopLineTestRABResPole is invalid
3. notsup…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.103
hwLoopLineTestCapAGFlag
Indicates whether the value of hwLoopLineTestCapAG is valid.
Options:
1. valid(1) -the value of hwLoopLineTestCapAG is valid
2. invalid(2) -the value of hwLoopLineTestCapAG is invalid
3. notsupport(3) -the v…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.104
hwLoopLineTestCapBGFlag
Indicates whether the value of hwLoopLineTestCapBG is valid.
Options:
1. valid(1) -the value of hwLoopLineTestCapBG is valid
2. invalid(2) -the value of hwLoopLineTestCapBG is invalid
3. notsupport(3) -the v…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.105
hwLoopLineTestCapABFlag
Indicates whether the value of hwLoopLineTestCapAB is valid.
Options:
1. valid(1) -the value of hwLoopLineTestCapAB is valid
2. invalid(2) -the value of hwLoopLineTestCapAB is invalid
3. notsupport(3) -the v…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.106
hwLoopLineTestRbattipFlag
Indicates whether the value of hwLoopLineTestRbattip is valid.
Options:
1. valid(1) -the value of hwLoopLineTestRbattip is valid
2. invalid(2) -the value of hwLoopLineTestRbattip is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.107
hwLoopLineTestRbatringFlag
Indicates whether the value of hwLoopLineTestRbatring is valid.
Options:
1. valid(1) -the value of hwLoopLineTestRbatring is valid
2. invalid(2) -the value of hwLoopLineTestRbatring is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.108
hwLoopLineTestRringFlag
Indicates whether the value of hwLoopLineTestRring is valid.
Options:
1. valid(1) -the value of hwLoopLineTestRring is valid
2. invalid(2) -the value of hwLoopLineTestRring is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.109
hwLoopLineTestCsigFlag
Indicates whether the value of hwLoopLineTestCsig is valid.
Options:
1. valid(1) -the value of hwLoopLineTestCsig is valid
2. invalid(2) -the value of hwLoopLineTestCsig is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.110
hwLoopLineTestPPAResFlag
Indicates whether the value of hwLoopLineTestPPARes is valid.
Options:
1. valid(1) -the value of hwLoopLineTestPPARes is valid
2. invalid(2) -the value of hwLoopLineTestPPARes is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.111
hwLoopLineTestVzenerFlag
Indicates whether the value of hwLoopLineTestVzener is valid.
Options:
1. valid(1) -the value of hwLoopLineTestVzener is valid
2. invalid(2) -the value of hwLoopLineTestVzener is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.112
hwLoopLineTestRzenerFlag
Indicates whether the value of hwLoopLineTestRzener is valid.
Options:
1. valid(1) -the value of hwLoopLineTestRzener is valid
2. invalid(2) -the value of hwLoopLineTestRzener is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.113
hwLoopLineTestSNMPRab
Indicates the A to B resistance (insulation resistance).
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.114
hwLoopLineTestSNMPRabFlag
Indicates whether the value of hwLoopLineTestSNMPRab is valid.
Options:
1. valid(1) -the value of hwLoopLineTestSNMPRab is valid
2. invalid(2) -the value of hwLoopLineTestSNMPRab is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.115
hwLoopLineTestSNMPRba
Indicates the B to A resistance (insulation resistance).
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.116
hwLoopLineTestSNMPRbaFlag
Indicates whether the value of hwLoopLineTestSNMPRba is valid.
Options:
1. valid(1) -the value of hwLoopLineTestSNMPRba is valid
2. invalid(2) -the value of hwLoopLineTestSNMPRba is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.117
hwLoopLineTestPPAResultFlag
Indicates whether the value of hwLoopLineTestPPA is valid.
Options:
1. valid(1) -the value of hwLoopLineTestPPA is valid
2. invalid(2) -the value of hwLoopLineTestPPA is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.118
hwLoopLineTestUtgAcFreqFlag
Indicates whether the value of hwLoopLineTestUtgAcFreq is valid.
Options:
1. valid(1) -the value of hwLoopLineTestUtgAcFreq is valid
2. invalid(2) -the value of hwLoopLineTestUtgAcFreq is invalid
3. notsupport…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.119
hwLoopLineTestUrgAcFreqFlag
Indicates whether the value of hwLoopLineTestUrgAcFreq is valid.
Options:
1. valid(1) -the value of hwLoopLineTestUrgAcFreq is valid
2. invalid(2) -the value of hwLoopLineTestUrgAcFreq is invalid
3. notsupport…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.120
hwLoopLineTestUtrAcFreqFlag
Indicates whether the value of hwLoopLineTestUtrAcFreq is valid.
Options:
1. valid(1) -the value of hwLoopLineTestUtrAcFreq is valid
2. invalid(2) -the value of hwLoopLineTestUtrAcFreq is invalid
3. notsupport…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.121
hwLoopLineTestItipAcFlag
Indicates whether the value of hwLoopLineTestItipAc is valid.
Options:
1. valid(1) -the value of hwLoopLineTestItipAc is valid
2. invalid(2) -the value of hwLoopLineTestItipAc is invalid
3. notsupport(3) -th…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.122
hwLoopLineTestIringAcFlag
Indicates whether the value of hwLoopLineTestIringAc is valid.
Options:
1. valid(1) -the value of hwLoopLineTestIringAc is valid
2. invalid(2) -the value of hwLoopLineTestIringAc is invalid
3. notsupport(3) …
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.123
hwLoopLineTestItipDcFlag
Indicates whether the value of hwLoopLineTestItipDc is valid.
Options:
1. valid(1) -the value of hwLoopLineTestItipDc is valid
2. invalid(2) -the value of hwLoopLineTestItipDc is invalid
3. notsupport(3) -th…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.124
hwLoopLineTestIringDcFlag
Indicates whether the value of hwLoopLineTestIringDc is valid.
Options:
1. valid(1) -the value of hwLoopLineTestIringDc is valid
2. invalid(2) -the value of hwLoopLineTestIringDc is invalid
3. notsupport(3) …
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.125
hwLoopLineTestGtgFlag
Indicates whether the value of hwLoopLineTestGtg is valid.
Options:
1. valid(1) -the value of hwLoopLineTestGtg is valid
2. invalid(2) -the value of hwLoopLineTestGtg is invalid
3. notsupport(3) -the value of…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.126
hwLoopLineTestBtgFlag
Indicates whether the value of hwLoopLineTestBtg is valid.
Options:
1. valid(1) -the value of hwLoopLineTestBtg is valid
2. invalid(2) -the value of hwLoopLineTestBtg is invalid
3. notsupport(3) -the value o…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.127
hwLoopLineTestGrgFlag
Indicates whether the value of hwLoopLineTestGrg is valid.
Options:
1. valid(1) -the value of hwLoopLineTestGrg is valid
2. invalid(2) -the value of hwLoopLineTestGrg is invalid
3. notsupport(3) -the value of…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.128
hwLoopLineTestBrgFlag
Indicates whether the value of hwLoopLineTestBrg is valid.
Options:
1. valid(1) -the value of hwLoopLineTestBrg is valid
2. invalid(2) -the value of hwLoopLineTestBrg is invalid
3. notsupport(3) -the value o…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.129
hwLoopLineTestGtrFlag
Indicates whether the value of hwLoopLineTestGtr is valid.
Options:
1. valid(1) -the value of hwLoopLineTestGtr is valid
2. invalid(2) -the value of hwLoopLineTestGtr is invalid
3. notsupport(3) -the value o…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.130
hwLoopLineTestBtrFlag
Indicates whether the value of hwLoopLineTestBtr is valid.
Options:
1. valid(1) -the value of hwLoopLineTestBtr is valid
2. invalid(2) -the value of hwLoopLineTestBtr is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.131
hwLoopLineTestSIGNFlag
Indicates whether the value of hwLoopLineTestSIGN is valid.
Options:
1. valid(1) -the value of hwLoopLineTestSIGN is valid
2. invalid(2) -the value of hwLoopLineTestSIGN is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.132
hwLoopLineTestACFEMFlag
Indicates whether the value of hwLoopLineTestACFEM is valid.
Options:
1. valid(1) -the value of hwLoopLineTestACFEM is valid
2. invalid(2) -the value of hwLoopLineTestACFEM is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.133
hwLoopLineTestDCFEMFlag
Indicates whether the value of hwLoopLineTestDCFEM is valid.
Options:
1. valid(1) -the value of hwLoopLineTestDCFEM is valid
2. invalid(2) -the value of hwLoopLineTestDCFEM is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.134
hwLoopLineTestONHKFlag
Indicates whether the value of hwLoopLineTestONHK is valid.
Options:
1. valid(1) -the value of hwLoopLineTestONHK is valid
2. invalid(2) -the value of hwLoopLineTestONHK is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.135
hwLoopLineTestOPENFlag
Indicates whether the value of hwLoopLineTestOPEN is valid.
Options:
1. valid(1) -the value of hwLoopLineTestOPEN is valid
2. invalid(2) -the value of hwLoopLineTestOPEN is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.136
hwLoopLineTestSHORTFlag
Indicates whether the value of hwLoopLineTestSHORT is valid.
Options:
1. valid(1) -the value of hwLoopLineTestSHORT is valid
2. invalid(2) -the value of hwLoopLineTestSHORT is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.137
hwLoopLineTestROHFlag
Indicates whether the value of hwLoopLineTestROH is valid.
Options:
1. valid(1) -the value of hwLoopLineTestROH is valid
2. invalid(2) -the value of hwLoopLineTestROH is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.138
hwLoopLineTestUtgDcUpFlag
Indicates whether the value of hwLoopLineTestUtgDcUp is valid.
Options:
1. valid(1) -the value of hwLoopLineTestUtgDcUp is valid
2. invalid(2) -the value of hwLoopLineTestUtgDcUp is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.139
hwLoopLineTestUtgDcDownFlag
Indicates whether the value of hwLoopLineTestUtgDcDown is valid.
Options:
1. valid(1) -the value of hwLoopLineTestUtgDcDown is valid
2. invalid(2) -the value of hwLoopLineTestUtgDcDown is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.140
hwLoopLineTestUrgDcUpFlag
Indicates whether the value of hwLoopLineTestUrgDcUp is valid.
Options:
1. valid(1) -the value of hwLoopLineTestUrgDcUp is valid
2. invalid(2) -the value of hwLoopLineTestUrgDcUp is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.141
hwLoopLineTestUrgDcDownFlag
Indicates whether the value of hwLoopLineTestUrgDcDown is valid.
Options:
1. valid(1) -the value of hwLoopLineTestUrgDcDown is valid
2. invalid(2) -the value of hwLoopLineTestUrgDcDown is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.142
hwLoopLineTestUtrPosFlag
Indicates whether the value of hwLoopLineTestUtrPos is valid.
Options:
1. valid(1) -the value of hwLoopLineTestUtrPos is valid
2. invalid(2) -the value of hwLoopLineTestUtrPos is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.143
hwLoopLineTestUtrNegFlag
Indicates whether the value of hwLoopLineTestUtrNeg is valid.
Options:
1. valid(1) -the value of hwLoopLineTestUtrNeg is valid
2. invalid(2) -the value of hwLoopLineTestUtrNeg is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.144
hwLoopLineTestItgDcUpFlag
Indicates whether the value of hwLoopLineTestItgDcUp is valid.
Options:
1. valid(1) -the value of hwLoopLineTestItgDcUp is valid
2. invalid(2) -the value of hwLoopLineTestItgDcUp is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.145
hwLoopLineTestItgDcDownFlag
Indicates whether the value of hwLoopLineTestItgDcDown is valid.
Options:
1. valid(1) -the value of hwLoopLineTestItgDcDown is valid
2. invalid(2) -the value of hwLoopLineTestItgDcDown is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.146
hwLoopLineTestIrgDcUpFlag
Indicates whether the value of hwLoopLineTestIrgDcUp is valid.
Options:
1. valid(1) -the value of hwLoopLineTestIrgDcUp is valid
2. invalid(2) -the value of hwLoopLineTestIrgDcUp is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.147
hwLoopLineTestIrgDcDownFlag
Indicates whether the value of hwLoopLineTestIrgDcDown is valid.
Options:
1. valid(1) -the value of hwLoopLineTestIrgDcDown is valid
2. invalid(2) -the value of hwLoopLineTestIrgDcDown is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.148
hwLoopLineTestItrPosFlag
Indicates whether the value of hwLoopLineTestItrPos is valid.
Options:
1. valid(1) -the value of hwLoopLineTestItrPos is valid
2. invalid(2) -the value of hwLoopLineTestItrPos is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.149
hwLoopLineTestItrNegFlag
Indicates whether the value of hwLoopLineTestItrNeg is valid.
Options:
1. valid(1) -the value of hwLoopLineTestItrNeg is valid
2. invalid(2) -the value of hwLoopLineTestItrNeg is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.150
hwLoopLineTestRingerFlag
Indicates whether the value of hwLoopLineTestRinger is valid.
Options:
1. valid(1) -the value of hwLoopLineTestRinger is valid
2. invalid(2) -the value of hwLoopLineTestRinger is invalid
Enumeration
Enumerated Values:
1valid
2invalid
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.151
hwLoopLineTestLRFlag
Indicates whether the value of hwLoopLineTestLR is valid.
Options:
1. valid(1) -the value of hwLoopLineTestLR is valid
2. invalid(2) -the value of hwLoopLineTestLR is invalid
3. notsupport(3) -the value of hw…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.152
hwLoopLineTestDcCurrent
Indicates whether DcCurrent exists on the line under test.
Options:
1. notest(1) -DcCurrent does not exist on the line under test
2. test(2) -DcCurrent exists on the line under test
3. invalid(-1) -invalid value
Enumerationr/w
Enumerated Values:
-1invalid
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.153
hwLoopLineTestAcCurrent
Indicates whether AcCurrent exists on the line under test.
Options:
1. notest(1) -AcCurrent does not exist on the line under test
2. test(2) -AcCurrent exists on the line under test
3. invalid(-1) -invalid value
Enumerationr/w
Enumerated Values:
-1invalid
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.154
hwLoopLineTestConductance
Indicates whether conductance exists on the line under test.
Options:
1. notest(1) -Conductance does not exist on the line under test
2. test(2) -Conductance exists on the line under test
3. invalid(-1) -invalid …
Enumerationr/w
Enumerated Values:
-1invalid
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.155
hwLoopLineTestSusceptance
Indicates whether susceptance exists on the line under test.
Options:
1. notest(1) -Susceptance does not exist on the line under test
2. test(2) -Susceptance exists on the line under test
3. invalid(-1) -invalid …
Enumerationr/w
Enumerated Values:
-1invalid
1notest
2test
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.156
hwLoopLineTestAcfrequencyA
Indicates status of Acfrequency in line A.
Options:
1. sixteenDotSix(1) -line A has ACFrequency 16.6
2. twentyFive(2) -line A has ACFrequency 25
3. fifty(3) -line A has ACFrequency 50
4. sixty(4) …
Enumeration
Enumerated Values:
-1invalid
1sixteenDotSix
2twentyFive
3fifty
4sixty
5unknown
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.157
hwLoopLineTestAcfrequencyB
Indicates status of Acfrequency in line A.
Options:
1. sixteenDotSix(1) -line A has ACFrequency 16.6
2. twentyFive(2) -line A has ACFrequency 25
3. fifty(3) -line A has ACFrequency 50
4. sixty(4) …
Enumeration
Enumerated Values:
-1invalid
1sixteenDotSix
2twentyFive
3fifty
4sixty
5unknown
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.158
hwLoopLineTestCapABH
Indicates the A->B capacitance.
Unit: nF
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.159
hwLoopLineTestCapABHFlag
Indicates whether the value of hwLoopLineTestCapABH is valid.
Options:
1. valid(1) -the value of hwLoopLineTestCapABH is valid
2. invalid(2) -the value of hwLoopLineTestCapABH is invalid
3. notsupport(3) -the…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.160
hwLoopLineTestGtrH
Indicates the A->B conductance.
Unit: nS
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.161
hwLoopLineTestGtrHFlag
Indicates whether the value of hwLoopLineTestGtrH is valid.
Options:
1. valid(1) -the value of hwLoopLineTestGtrH is valid
2. invalid(2) -the value of hwLoopLineTestGtrH is invalid
3. notsupport(3) -the value…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.162
hwLoopLineTestBtrH
Indicates the A->B susceptance.
Unit: nS
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.163
hwLoopLineTestBtrHFlag
Indicates whether the value of hwLoopLineTestBtrH is valid.
Options:
1. valid(1) -the value of hwLoopLineTestBtrH is valid
2. invalid(2) -the value of hwLoopLineTestBtrH is invalid
3. notsupport(3) -the value…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.164
hwLoopLineTestABDcCurrent
Indicates the A->B Dc current.
Unit: uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.165
hwLoopLineTestABDcCurrentFlag
Indicates whether the value of hwLoopLineTestABDcCurrent is valid.
Options:
1. valid(1) -the value of hwLoopLineTestABDcCurrent is valid
2. invalid(2) -the value of hwLoopLineTestABDcCurrent is invalid
3. nots…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.166
hwLoopLineTestBADcCurrent
Indicates the B->A Dc current.
Unit: uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.167
hwLoopLineTestBADcCurrentFlag
Indicates whether the value of hwLoopLineTestBADcCurrent is valid.
Options:
1. valid(1) -the value of hwLoopLineTestBADcCurrent is valid
2. invalid(2) -the value of hwLoopLineTestBADcCurrent is invalid
3. nots…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.168
hwLoopLineTestABAcCurrent
Indicates the A->B Ac current.
Unit: uArms
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.169
hwLoopLineTestABAcCurrentFlag
Indicates whether the value of hwLoopLineTestABAcCurrent is valid.
Options:
1. valid(1) -the value of hwLoopLineTestABAcCurrent is valid
2. invalid(2) -the value of hwLoopLineTestABAcCurrent is invalid
3. nots…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.170
hwLoopLineTestBAAcCurrent
Indicates the B->A Ac current.
Unit: uArms
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.171
hwLoopLineTestBAAcCurrentFlag
Indicates whether the value of hwLoopLineTestBAAcCurrent is valid.
Options:
1. valid(1) -the value of hwLoopLineTestBAAcCurrent is valid
2. invalid(2) -the value of hwLoopLineTestBAAcCurrent is invalid
3. nots…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.172
hwLoopLineTestCSfrequencyForTest
Indicates the frequency for test capacitance and conductance.
Unit: Hz
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.173
hwLoopLineTestCSfrequencyForTestFlag
Indicates whether the value of hwLoopLineTestCSfrequencyForTest is valid.
Options:
1. valid(1) -the value of hwLoopLineTestCSfrequencyForTest is valid
2. invalid(2) -the value of hwLoopLineTestCSfrequencyForTe…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.174
hwLoopLineTestImpedanceForTest
Indicates the resistance inputed in test abnormal voltage.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.175
hwLoopLineTestImpedanceForTestFlag
Indicates whether the value of hwLoopLineTestImpedanceForTest is valid.
Options:
1. valid(1) -the value of hwLoopLineTestImpedanceForTest is valid
2. invalid(2) -the value of hwLoopLineTestImpedanceForTest is …
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.176
hwLoopLineTestMaxVForSignature
Indicates the maximum voltage for signature.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.177
hwLoopLineTestMaxVForSignatureFlag
Indicates whether the value of hwLoopLineTestMaxVForSignature is valid.
Options:
1. valid(1) -the value of hwLoopLineTestMaxVForSignature is valid
2. invalid(2) -the value of hwLoopLineTestMaxVForSignature is …
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.178
hwLoopLineTestAGMaxVForTest
Indicates the A->ground max voltage in testing.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.179
hwLoopLineTestAGMaxVForTestFlag
Indicates whether the value of hwLoopLineTestAGMaxVForTest is valid.
Options:
1. valid(1) -the value of hwLoopLineTestAGMaxVForTest is valid
2. invalid(2) -the value of hwLoopLineTestAGMaxVForTest is invalid
3…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.180
hwLoopLineTestAGMinVForTest
Indicates the A->ground min voltage in testing.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.181
hwLoopLineTestAGMinVForTestFlag
Indicates whether the value of hwLoopLineTestAGMinVForTest is valid.
Options:
1. valid(1) -the value of hwLoopLineTestAGMinVForTest is valid
2. invalid(2) -the value of hwLoopLineTestAGMinVForTest is invalid
3…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.182
hwLoopLineTestBGMaxVForTest
Indicates the B->ground max voltage in testing.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.183
hwLoopLineTestBGMaxVForTestFlag
Indicates whether the value of hwLoopLineTestBGMaxVForTest is valid.
Options:
1. valid(1) -the value of hwLoopLineTestBGMaxVForTest is valid
2. invalid(2) -the value of hwLoopLineTestBGMaxVForTest is invalid
3…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.184
hwLoopLineTestBGMinVForTest
Indicates the B->ground min voltage in testing.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.185
hwLoopLineTestBGMinVForTestFlag
Indicates whether the value of hwLoopLineTestBGMinVForTest is valid.
Options:
1. valid(1) -the value of hwLoopLineTestBGMinVForTest is valid
2. invalid(2) -the value of hwLoopLineTestBGMinVForTest is invalid
3…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.186
hwLoopLineTestABMaxVForTest
Indicates the A->B max voltage in testing.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.187
hwLoopLineTestABMaxVForTestFlag
Indicates whether the value of hwLoopLineTestABMaxVForTest is valid.
Options:
1. valid(1) -the value of hwLoopLineTestABMaxVForTest is valid
2. invalid(2) -the value of hwLoopLineTestABMaxVForTest is invalid
3…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.188
hwLoopLineTestABMinVForTest
Indicates the A->ground min voltage in testing.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.189
hwLoopLineTestABMinVForTestFlag
Indicates whether the value of hwLoopLineTestABMinVForTest is valid.
Options:
1. valid(1) -the value of hwLoopLineTestABMinVForTest is valid
2. invalid(2) -the value of hwLoopLineTestABMinVForTest is invalid
3…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.190
hwLoopLineTestAGMaxCForTest
Indicates the A->ground max current.
Unit: uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.191
hwLoopLineTestAGMaxCForTestFlag
Indicates whether the value of hwLoopLineTestAGMaxCForTest is valid.
Options:
1. valid(1) -the value of hwLoopLineTestAGMaxCForTest is valid
2. invalid(2) -the value of hwLoopLineTestAGMaxCForTest is invalid
3…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.192
hwLoopLineTestAGMinCForTest
Indicates the A->ground min current.
Unit: uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.193
hwLoopLineTestAGMinCForTestFlag
Indicates whether the value of hwLoopLineTestAGMinCForTest is valid.
Options:
1. valid(1) -the value of hwLoopLineTestAGMinCForTest is valid
2. invalid(2) -the value of hwLoopLineTestAGMinCForTest is invalid
3…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.194
hwLoopLineTestBGMaxCForTest
Indicates the B->ground max current.
Unit: uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.195
hwLoopLineTestBGMaxCForTestFlag
Indicates whether the value of hwLoopLineTestBGMaxCForTest is valid.
Options:
1. valid(1) -the value of hwLoopLineTestBGMaxCForTest is valid
2. invalid(2) -the value of hwLoopLineTestBGMaxCForTest is invalid
3…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.196
hwLoopLineTestBGMinCForTest
Indicates the B->ground min current.
Unit: uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.197
hwLoopLineTestBGMinCForTestFlag
Indicates whether the value of hwLoopLineTestBGMinCForTest is valid.
Options:
1. valid(1) -the value of hwLoopLineTestBGMinCForTest is valid
2. invalid(2) -the value of hwLoopLineTestBGMinCForTest is invalid
3…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.198
hwLoopLineTestABMaxCForTest
Indicates the A->B max current
Unit: uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.199
hwLoopLineTestABMaxCForTestFlag
Indicates whether the value of hwLoopLineTestABMaxCForTest is valid.
Options:
1. valid(1) -the value of hwLoopLineTestABMaxCForTest is valid
2. invalid(2) -the value of hwLoopLineTestABMaxCForTest is invalid
3…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.200
hwLoopLineTestABMaxNegCForTest
Indicates the A->ground min current
Unit: uA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.201
hwLoopLineTestABMaxNegCForTestFlag
Indicates whether the value of hwLoopLineTestABMaxNegCForTest is valid.
Options:
1. valid(1) -the value of hwLoopLineTestABMaxNegCForTest is valid
2. invalid(2) -the value of hwLoopLineTestABMaxNegCForTest is …
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.202
hwLoopLineTestLineALength
Indicates length of line A
Unit: m
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.203
hwLoopLineTestLineBLength
Indicates length of line B
Unit: m
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.204
hwLoopLineTestTermimalConcusion
Indicates Termimal Concusion
Options:
1. noPhone(1) -the TermimalConcusion is not connect Phone
2. offHook(2) -the TermimalConcusion is connect phone and offhook
3. eTSIxDSLsi…
Enumeration
Enumerated Values:
-1invalid
1noPhone
2offHook
3eTSIxDSLsignature
4abMixed
5rcNetWork
6elecRing
7other
8abMixInMDF
9abMixOutMDF
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.205
hwLoopLineTestMoreDataFlag
Indicates is there more data
Options:
1. more(1) -Indicates there is more data needs report,but needs a SNMP-GET oper. to get other data.
2. invalid(-1) -Indicates the value is invalid
Enumeration
Enumerated Values:
-1invalid
1more
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.206
hwLoopLineTestCtrLV
Aggregate tip-ring capacitance: CtrLV = Cco + Ctr + Cring, measured by means of low voltage ramps,
such that it does NOT include the capacitance Csig whenever the ETSI Signature terminates the subscriber loop.
Unit: nF
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.207
hwLoopLineTestCtrLVFlag
Indicates whether the value of hwLoopLineTestCtrLV is valid.
Options:
1. valid(1) -the value of hwLoopLineTestCtrLV is valid
2. invalid(2) -the value of hwLoopLineTestCtrLV is invalid
3. notsupport(3) -the v…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.208
hwLoopLineTestCtrHV
Aggregate tip-ring capacitance: CtrHV = Cco + Ctr + Cring + Csig, measured by means of high voltage ramps.
It includes the capacitance Csig of an ETSI Signature whenever connected to the tip and ring wires.
Unit: nF
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.209
hwLoopLineTestCtrHVFlag
Indicates whether the value of hwLoopLineTestCtrHV is valid.
Options:
1. valid(1) -the value of hwLoopLineTestCtrHV is valid
2. invalid(2) -the value of hwLoopLineTestCtrHV is invalid
3. notsupport(3) -the v…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.210
hwLoopLineTestCtrAc
Aggregate tip-ring capacitance: CtrAc = Cco + Ctr + Cring, measured by means of a low amplitude
AC signal (either 25 Hz or 275 Hz). It does NOT include Csig.
Unit: nF
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.211
hwLoopLineTestCtrAcFlag
Indicates whether the value of hwLoopLineTestCtrAc is valid.
Options:
1. valid(1) -the value of hwLoopLineTestCtrAc is valid
2. invalid(2) -the value of hwLoopLineTestCtrAc is invalid
3. notsupport(3) -the v…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.212
hwLoopLineTestRtgSer
Resistance in series with Ctg, measured at the selected AC frequency (either 25 Hz or 275 Hz)
by means of a low amplitude AC signal.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.213
hwLoopLineTestRtgSerFlag
Indicates whether the value of hwLoopLineTestRtgSer is valid.
Options:
1. valid(1) -the value of hwLoopLineTestRtgSer is valid
2. invalid(2) -the value of hwLoopLineTestRtgSer is invalid
3. notsupport(3) -th…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.214
hwLoopLineTestRrgSer
Resistance in series with Crg, measured at the selected AC frequency (either 25 Hz or 275 Hz)
by means of a low amplitude AC signal.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.215
hwLoopLineTestRrgSerFlag
Indicates whether the value of hwLoopLineTestRrgSer is valid.
Options:
1. valid(1) -the value of hwLoopLineTestRrgSer is valid
2. invalid(2) -the value of hwLoopLineTestRrgSer is invalid
3. notsupport(3) -th…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.216
hwLoopLineTestRtrSer
Resistance in series with Ctring, measured at the selected AC frequency (either 25 Hz or 275 Hz)
by means of a low amplitude AC signal.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.217
hwLoopLineTestRtrSerFlag
Indicates whether the value of hwLoopLineTestRtrSer is valid.
Options:
1. valid(1) -the value of hwLoopLineTestRtrSer is valid
2. invalid(2) -the value of hwLoopLineTestRtrSer is invalid
3. notsupport(3) -th…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.218
hwLoopLineTestUtgAcAdmit
Amplitude of the AC signal (either 25 Hz or 275 Hz) applied to the tipground admittance Ytg = Gtg + i * Btg.
Unit: V
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.219
hwLoopLineTestUtgAcAdmitFlag
Indicates whether the value of hwLoopLineTestUtgAcAdmit is valid.
Options:
1. valid(1) -the value of hwLoopLineTestUtgAcAdmit is valid
2. invalid(2) -the value of hwLoopLineTestUtgAcAdmit is invalid
3. notsup…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.220
hwLoopLineTestUrgAcAdmit
Amplitude of the AC signal (either 25 Hz or 275 Hz) applied to the ringground admittance Yrg = Grg + i * Brg.
Unit: V
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.221
hwLoopLineTestUrgAcAdmitFlag
Indicates whether the value of hwLoopLineTestUrgAcAdmit is valid.
Options:
1. valid(1) -the value of hwLoopLineTestUrgAcAdmit is valid
2. invalid(2) -the value of hwLoopLineTestUrgAcAdmit is invalid
3. notsup…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.222
hwLoopLineTestUtrAcAdmit
Amplitude of the AC signal (either 25 Hz or 275 Hz) applied to the tip-ring admittance Ytr = Gtr + i * Btr.
Unit: V
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.223
hwLoopLineTestUtrAcAdmitFlag
Indicates whether the value of hwLoopLineTestUtrAcAdmit is valid.
Options:
1. valid(1) -the value of hwLoopLineTestUtrAcAdmit is valid
2. invalid(2) -the value of hwLoopLineTestUtrAcAdmit is invalid
3. notsup…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.224
hwLoopLineTestCapterminal
A capacitive termination of the access line shall be identified by the capacitance measurement and the associated evaluation.
The following average value for the capacitance Cabk of the measured cable can be assumed:
Ca…
Enumeration
Enumerated Values:
1noexist
2exist
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.225
hwLoopLineTestCapterminalFlag
Indicates whether the value of hwLoopLineTestCapterminal is valid.
Options:
1. valid(1) -the value of hwLoopLineTestCapterminal is valid
2. invalid(2) -the value of hwLoopLineTestCapterminal is invalid
3. not…
Enumeration
Enumerated Values:
1valid
2invalid
3notsupport
.1.3.6.1.4.1.2011.6.21.1.1.1.2.1.226
.1.3.6.1.4.1.2011.6.21.1.1.1.3 · 1 row entry · 4 columns
Operation table of the meter test.
It implements the meter test function in the system. The test board provides the interface connected to the external test meter such as a multimeter through the meter test function.
The index of this table is ifIndex.
hwMeterTestOprEntry entry .1.3.6.1.4.1.2011.6.21.1.1.1.3.1
Operation table of the meter test.
It implements the meter test function in the system. The test board provides the interface connected to the external test meter such as a multimeter through the meter test function.
Th…
Indexes
IF-MIBifIndex
Column Syntax OID
hwMeterTestOprType
Operation type.
Options:
1. stop(1) -operation type is stop
2. start(2) -operation type is start
Enumerationr/w
Enumerated Values:
1stop
2start
.1.3.6.1.4.1.2011.6.21.1.1.1.3.1.1
hwMeterTestItem
Test items.
Options:
1. inline(1) -in test
2. outline(2) -out test
Enumerationr/w
Enumerated Values:
1inline
2outline
.1.3.6.1.4.1.2011.6.21.1.1.1.3.1.2
hwMeterTestStatus
Test status.
Options:
1. success(1) -no test on busy
2. fail(2) -remedy test on busy
3. portbusy(3) -forced test on busy
4. outoftime(4) -test out …
Enumeration
Enumerated Values:
1success
2fail
3portbusy
4outoftime
5testingAbnormal
6broadbandtesting
7capturefail
8notratb
.1.3.6.1.4.1.2011.6.21.1.1.1.3.1.3
hwMeterTestBusyFlag
Meter test busy flag.
Options:
1. busyNoTest(1) -no test on busy
2. busyTest(2) -test on busy
3. busystrenTest(3) -forced test on busy
Enumerationr/w
Enumerated Values:
1busyNoTest
2busyTest
3busystrenTest
.1.3.6.1.4.1.2011.6.21.1.1.1.3.1.4
.1.3.6.1.4.1.2011.6.21.1.1.1.4 · 1 row entry · 13 columns
Operation table of the self-test on the test board.
It implements the self-test on the test board in the system. The self-test checks whether the test board can work in the normal state.
The index of this table is ifIndex.
hwTestBoardDiagnoseTestOprEntry entry .1.3.6.1.4.1.2011.6.21.1.1.1.4.1
Operation table of the self-test on the test board.
It implements the self-test on the test board in the system. The self-test checks whether the test board can work in the normal state.
The index of this entry is ifInd…
Indexes
IF-MIBifIndex
Column Syntax OID
hwTestBoardDiagnoseTestOprType
Operation type.
Options:
1. start(2) -operation type is start
Enumerationr/w
Enumerated Values:
2start
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.1
hwTestBoardDiagnoseTestResult
Self-diagnosis result.
Options:
1. selfTestOver(1) -self-diagnosis successful
2. selfTestFail(2) -self-diagnosis failure
3. testingAbnormal(3) -test abnormal
Enumeration
Enumerated Values:
1selfTestOver
2selfTestFail
3testingAbnormal
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.2
hwTestBoardDiagnoseTestRAM
System RAMRAM.
Options:
1. normal(1) -normal
2. abnormal(2) -abnormal
Enumeration
Enumerated Values:
1normal
2abnormal
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.3
hwTestBoardDiagnoseTestVoltage
Voltage.
Options:
1. normal(1) -normal
2. abnormal(2) -abnormal
Enumeration
Enumerated Values:
1normal
2abnormal
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.4
hwTestBoardDiagnoseTestResistance
Resistance.
Options:
1. normal(1) -normal
2. abnormal(2) -abnormal
Enumeration
Enumerated Values:
1normal
2abnormal
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.5
hwTestBoardDiagnoseTestSignal
Signal circuit.
Options:
1. normal(1) -normal
2. abnormal(2) -abnormal
Enumeration
Enumerated Values:
1normal
2abnormal
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.6
hwTestBoardDiagnoseTestDTMF
DTMF.
Options:
1. normal(1) -normal
2. abnormal(2) -abnormal
Enumeration
Enumerated Values:
1normal
2abnormal
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.7
hwTestBoardDiagnoseTestRing
Ringing.
Options:
1. normal(1) -normal
2. abnormal(2) -abnormal
Enumeration
Enumerated Values:
1normal
2abnormal
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.8
hwTestBoardDiagnoseTestOnOffHook
On/off hook.
Options:
1. normal(1) -normal
2. abnormal(2) -abnormal
Enumeration
Enumerated Values:
1normal
2abnormal
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.9
hwTestBoardDiagnoseTestPole
Polarity reversal.
Options:
1. normal(1) -normal
2. abnormal(2) -abnormal
Enumeration
Enumerated Values:
1normal
2abnormal
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.10
hwTestBoardDiagnoseTestISDNU
ISDN U port.
Options:
1. normal(1) -normal
2. abnormal(2) -abnormal
Enumeration
Enumerated Values:
1normal
2abnormal
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.11
hwTestBoardDiagnoseTestBitErrCode
Error code test.
Options:
1. normal(1) -normal
2. abnormal(2) -abnormal
Enumeration
Enumerated Values:
1normal
2abnormal
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.12
hwTestBoardDiagnoseTestCapacitance
Capacitance.
Options:
1. normal(1) -normal
2. abnormal(2) -abnormal
Enumeration
Enumerated Values:
1normal
2abnormal
.1.3.6.1.4.1.2011.6.21.1.1.1.4.1.13
.1.3.6.1.4.1.2011.6.21.1.1.1.5 · 1 row entry · 5 columns
Operation table for querying the status of the test board.
It implements the function of querying the status of the test board in the system. You can query the current status of the test board through this function.
The index of this table is ifIndex.
hwTestBoardStatusQueryOprEntry entry .1.3.6.1.4.1.2011.6.21.1.1.1.5.1
Operation table for querying the status of the test board.
It implements the function of querying the status of the test board in the system. You can query the current status of the test board through this function.
The…
Indexes
IF-MIBifIndex
Column Syntax OID
hwTestBoardStatusQueryOprType
Operation type.
Options:
1. beginQuery(2) -start
Enumerationr/w
Enumerated Values:
2beginQuery
.1.3.6.1.4.1.2011.6.21.1.1.1.5.1.1
hwTestBoardStatusQueryResult
Query status.
Options:
1. querySuccess(1) -query status successful
2. queryFail(2) -query status failure
Enumeration
Enumerated Values:
1querySuccess
2queryFail
.1.3.6.1.4.1.2011.6.21.1.1.1.5.1.2
hwTestBoardStatusQueryVersion
Version.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.5.1.3
hwTestBoardStatusQueryTestItem
Test item.
Options:
1. testIdle(1) -idle
2. pstnUserInLineTest(2) -pstn inline test
3. userLineTest(3) -loop line test
4. phoneTest(4) …
Enumeration
Enumerated Values:
1testIdle
2pstnUserInLineTest
3userLineTest
4phoneTest
5manTestOutLine
6manTestInnerLine
7halfAutoUserCircuit
8halfAutoTssPhoneCircuit
9tssSelfTest
10testInnerBus
11testOuterBus
12digUserOutLineTest
13digUserInnerLineTest
14switchToStandIsdnTerminal
15switchToIsdnSpecialcode
16testBoarDfault
17pstnRemoteCallTest
18indialtest
33coEmulate
34cqtTest
35cqtFRTest
36cqtTDRTest
37cqtDMTTest
38cqtNSETest
39cqtLBTest
40cqtLCTest
61internalcaptureTestedPort
62externalcaptureTestedPort
63monitorTest
64seltTest
65sendtoneTest
66checktoneTest
67autocalltest
241anothermainboardistesting
.1.3.6.1.4.1.2011.6.21.1.1.1.5.1.4
hwTestBoardStatusTestedBoardIfIndex
Index of the tested port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.5.1.5
.1.3.6.1.4.1.2011.6.21.1.1.1.6 · 1 row entry · 6 columns
This table is used for enabling the searching tone test by setting the searching tone
test voltage level, test frequency, and test duration. The searching tone test
is to locate a specific line from various lines by transmitting pulse tones to lines.
This test helps carriers locate faults and provision services.
The index of this table is ifindex.
hwSearchingToneOprEntry entry .1.3.6.1.4.1.2011.6.21.1.1.1.6.1
This table is used for enabling the searching tone test by setting the searching tone
test voltage level, test frequency, and test duration. The searching tone test
is to locate a specific line from various lines by tra…
Indexes
IF-MIBifIndex
Column Syntax OID
hwSearchingToneOprType
Searching tone test-operation type.
Options:
1. stop(1) -stop a searching tone test
2. start(2) -start a searching tone test
3. invalid(-1) -invalid value
Enumerationr/w
Enumerated Values:
-1invalid
1stop
2start
.1.3.6.1.4.1.2011.6.21.1.1.1.6.1.1
hwSearchingToneLevel
Indicates the test voltage level of a searching tone test.
Options:
1. -1 -Invalid value
2. 80..500 -(XDSL Range: 80-126 MXU voice Range: 80-500)
Default: 120 -(XDSL Default: 120 MXU voice def…
Integer32r/w
Constraints:
range: -1--1
range: 80-500
.1.3.6.1.4.1.2011.6.21.1.1.1.6.1.2
hwSearchingToneFrequency
Indicates the test frequency of a searching tone test.
Default: 800
Unit: Hz
Integer32r/w
Constraints:
range: -1--1
range: 300-3400
.1.3.6.1.4.1.2011.6.21.1.1.1.6.1.3
hwSearchingToneDurationTime
Indicates the test duration of a searching tone test.
Default: 9000
Unit: 0.1s
Integer32r/w
Constraints:
range: -1--1
range: 1-54000
.1.3.6.1.4.1.2011.6.21.1.1.1.6.1.4
hwSearchingToneRemainingTime
Indicates the test remaining time of a searching tone test.
Unit: 0.1s
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.6.1.5
hwSearchingToneBusyProcFlag
Searching tone test-busy flag.
Options:
1. cancel(1) -when port is busy do not start a searching tone test
2. force(2) -when port is busy force to start a searching tone test
3. invalid(-1) -invalid value
Enumerationr/w
Enumerated Values:
-1invalid
1cancel
2force
.1.3.6.1.4.1.2011.6.21.1.1.1.6.1.6
.1.3.6.1.4.1.2011.6.21.1.1.1.7 · 1 row entry · 3 columns
This table provides the test calibration data of a line. Before delivery,
each port is performed with a test in which no user is connected to the
port and the test result is saved as standard data. The standard data is used for
calibrating the test result of tests in the actual environment.
The index of this table is ifindex.
hwLoopLineTestCalibrationEntry entry .1.3.6.1.4.1.2011.6.21.1.1.1.7.1
This table provides the test calibration data of a line. Before delivery,
each port is performed with a test in which no user is connected to the
port and the test result is saved as standard data. The standard data is …
Indexes
IF-MIBifIndex
Column Syntax OID
hwLoopLineTestAGCalibration
Indicates the test calibration data of A->Ground capacitance.
Unit: nF
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.7.1.1
hwLoopLineTestBGCalibration
Indicates the test calibration data of B->Ground capacitance.
Unit: nF
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.7.1.2
hwLoopLineTestABCalibration
Indicates the test calibration data of A->B capacitance.
Unit: nF
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.7.1.3
.1.3.6.1.4.1.2011.6.21.1.1.1.8 · 1 row entry · 3 columns
This table provides the information about the MELT chip on the board,
including the vendor, hardware version, and software version.
The indexes of this table are hwFrameIndex and hwSlotIndex.
hwLoopLineTestMeltVerEntry entry .1.3.6.1.4.1.2011.6.21.1.1.1.8.1
This table provides the information about the MELT chip on the board,
including the vendor, hardware version, and software version.
The indexes of this entry are hwFrameIndex and hwSlotIndex.
Indexes
HUAWEI-DEVICE-MIBhwFrameIndex HUAWEI-DEVICE-MIBhwSlotIndex
Column Syntax OID
hwLoopLineTestMeltFactory
MELT chipset manufacturer information
Maximum length: 32 Octets
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.2011.6.21.1.1.1.8.1.1
hwLoopLineTestMeltChip
MELT chipset manufacturer hardware information
Maximum length: 128 Octets
OctetString
Constraints:
range: 0-128
.1.3.6.1.4.1.2011.6.21.1.1.1.8.1.2
hwLoopLineTestMeltFirmwareVer
MELT chipset manufacturer version information
Maximum length: 16 Octets
OctetString
Constraints:
range: 0-16
.1.3.6.1.4.1.2011.6.21.1.1.1.8.1.3
.1.3.6.1.4.1.2011.6.21.1.1.1.10 · 1 row entry · 71 columns
This table is used for enabling the POTS port line test of the ONT by setting the test
item, test frequency, and test threshold. This test helps operators locate faults and
provision services.
The indexes of this table are ifindex, hwONTPotsTestONTIndex and hwONTPotsTestONTPstnPortIndex.
hwONTPotsTestOprEntry entry .1.3.6.1.4.1.2011.6.21.1.1.1.10.1
This table is used for enabling the POTS port line test of the ONT by setting the test
item, test frequency, and test threshold. This test helps operators locate faults and
provision services.
The indexes of this entry …
Indexes
IF-MIBifIndex hwONTPotsTestONTIndex hwONTPotsTestONTPstnPortIndex
Column Syntax OID
hwONTPotsTestONTIndex
ONT ID.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.1
hwONTPotsTestONTPstnPortIndex
ONT port ID.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.2
hwONTPotsTestOprType
POTS port line Test-operation type.
Options:
1. stop(1) -stop a POTS port line test
2. start(2) -start a POTS port line test
3. invalid(-1) -invalid value
Enumerationr/w
Enumerated Values:
-1invalid
1stop
2start
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.3
hwONTPotsTestItem
POTS port line test item.
Options:
1. allMLTTests(1) -outdoor connection test
2. hazardousPotential(2) -hazardous potential test
3. foreignEMF(3) -foreign electromotive force(EMF) te…
Enumerationr/w
Enumerated Values:
1allMLTTests
2hazardousPotential
3foreignEMF
4resistiveFaults
5receiverOffHook
6ringer
7nT1DcSignatureTest
8selfTest
9dialToneMakeBreakTest
10subscriberLine
11vendorSpecificTest2
12vendorSpecificTest3
13vendorSpecificTest4
14vendorSpecificTest5
15vendorSpecificTest6
16vendorSpecificTest7
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.4
hwONTPotsTestBusyProcFlag
Test mode when a line is busy.
Options:
1. cancel(1) -deny a test if a line is busy
2. force(2) -forced mode
Enumerationr/w
Enumerated Values:
1cancel
2force
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.5
hwONTPotsTestT1Threshold
Slow dial tone threshold.
Options:
1. 0 -Invalid value. It indicates that an ONT will use its default value
2. 100..6000 -Valid value range
Integer32r/w
Constraints:
range: 0-0
range: 100-6000
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.6
hwONTPotsTestT2Threshold
No dial tone threshold.
Options:
1. 0 -Invalid value. It indicates that an ONT will use its default value
2. 1000..10000 -Valid value range
Integer32r/w
Constraints:
range: 0-0
range: 1000-10000
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.7
hwONTPotsTestT3Threshold
Slow break dial tone threshold.
Options:
1. 0 -Invalid value. It indicates that an ONT will use its default value
2. 100..3000 -Valid value range
Integer32r/w
Constraints:
range: 0-0
range: 100-3000
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.8
hwONTPotsTestT4Threshold
No break dial tone threshold.
Options:
1. 0 -Invalid value. It indicates that an ONT will use its default value
2. 1000..3000 -Valid value range
Integer32r/w
Constraints:
range: 1000-3000
range: 0-0
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.9
hwONTPotsTestDtmfDigit
DTMF test number.
Options:
1. zero(1) -the test number is 0
2. one(2) -the test number is 1
3. two(3) -the test number is 2
4. three(4) -the test number is 3
5. four(5) -the test…
Enumerationr/w
Enumerated Values:
1zero
2one
3two
4three
5four
6five
7six
8seven
9eight
10nine
11symbolStar
12symbolSharp
13default
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.10
hwONTPotsTestDialType
The dialling type of dialling tone test.
Options:
1. dtmf(1) -dtmf type
2. pulse(2) -pulse type
Enumerationr/w
Enumerated Values:
1dtmf
2pulse
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.11
hwONTPotsTestDialToneFreq1
The frequency1 in the dialling tone test.
0 -unused
Unit: Hz
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.12
hwONTPotsTestDialToneFreq2
The frequency2 in the dialling tone test.
0 -unused
Unit: Hz
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.13
hwONTPotsTestDialToneFreq3
The frequency3 in the dialling tone test.
0 -unused
Unit: Hz
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.14
hwONTPotsTestDialToneEnergyThreshold
The value of energy threshold in the dialling tone test.
Valid value:
1. 0x00: unspecified
2. 0x01-0xFD: -0.1 dBm0 to -25.3 dBm0
Unit: 0.1 dBm0
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.15
hwONTPotsTestIdleChannelEnergyThreshold
The value of energy threshold in the dialling tone test when the line
is in the idle state.
Valid value:
1. 0x00: unspecified
2. 0x01-0x5A: -1 dBm0 to -90 dBm0
Unit: 1 dBm0
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.16
hwONTPotsTestDCHazardousVoltThreshold
The value of DC voltage threshold in the hazardous potential test.
0x00 -unspecified
Unit: volt
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.17
hwONTPotsTestACHazardousVoltThreshold
The value of AC voltage threshold in the hazardous potential test.
0x00 -unspecified
Unit: volt.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.18
hwONTPotsTestDCForeignVoltThreshold
The value of DC voltage threshold in the foreign volt test.
0x00 -unspecified
Unit: volt
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.19
hwONTPotsTestACForeignVoltThreshold
The value of AC voltage threshold in the foreign volt test.
0x00 -unspecified
Unit: volt
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.20
hwONTPotsTestAGBGResistanceThreshold
The resistance (tip to ground, ring to ground) threshold in the
resistive faults test.
0x00 -unspecified
Unit: kilohm
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.21
hwONTPotsTestABResistanceThreshold
The resistance (tip to ring) threshold in the resistive faults test.
0x00 -unspecified
Unit: kilohm
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.22
hwONTPotsTestRingerEquivMinThreshold
Ringer equivalence minimum threshold.
0x00 -unspecified
Unit: 0.01 REN
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.23
hwONTPotsTestRingerEquivMaxThreshold
Ringer equivalence maximum threshold.
0x00 -unspecified
Unit: 0.01 REN
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.24
hwONTPotsTestMLTResult
MLT qualitative test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run
Enumeration
Enumerated Values:
1failed
2passOrNotRun
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.25
hwONTPotsTestHazardousVoltResult
Hazardous volt test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run
Enumeration
Enumerated Values:
1failed
2passOrNotRun
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.26
hwONTPotsTestEMFResult
EMF test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run
Enumeration
Enumerated Values:
1failed
2passOrNotRun
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.27
hwONTPotsTestResistacneResult
Resistacne test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run
Enumeration
Enumerated Values:
1failed
2passOrNotRun
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.28
hwONTPotsTestOffHookResult
The off-hook test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run
Enumeration
Enumerated Values:
1failed
2passOrNotRun
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.29
hwONTPotsTestRingerResult
Ringer test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run
Enumeration
Enumerated Values:
1failed
2passOrNotRun
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.30
hwONTPotsTestNT1DCSignalResult
NT1 DC Signal test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run
Enumeration
Enumerated Values:
1failed
2passOrNotRun
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.31
hwONTPotsTestSelfTestResult
Self test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run
3. notCompleted(3) -a test is not complete yet
Enumeration
Enumerated Values:
1failed
2passOrNotRun
3notCompleted
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.32
hwONTPotsTestDrawDialToneResult
Draw dialling tone test result.
Options:
1. notRun(1) -a test does not run
2. couldNotDraw1(3) -a test fails to draw
3. couldNotDraw2(4) -a test fails to draw
4. slowDraw…
Enumeration
Enumerated Values:
1notRun
3couldNotDraw1
4couldNotDraw2
5slowDraw1
6slowDraw2
7pass1
8pass2
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.33
hwONTPotsTestBreakDialToneResult
The break dialling tone test result.
Options:
1. notRun(1) -a test does not run
2. couldNotDraw1(3) -a test fails to draw
3. couldNotDraw2(4) -a test fails to draw …
Enumeration
Enumerated Values:
1notRun
3couldNotDraw1
4couldNotDraw2
5slowDraw1
6slowDraw2
7pass1
8pass2
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.34
hwONTPotsTestQuietEnergyResult
The quiet energy test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
the measurement is not reported
3. failMea…
Enumeration
Enumerated Values:
1notRun
3failMeasurementNotReported
4failMeasurementReported
7passMeasurementNotReported
8passMeasurementReported
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.35
hwONTPotsTestDialToneEnergyResult
The dialling tone energy test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
the measurement is not reported
3.…
Enumeration
Enumerated Values:
1notRun
3failMeasurementNotReported
4failMeasurementReported
7passMeasurementNotReported
8passMeasurementReported
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.36
hwONTPotsTestLoopDCAGVoltResult
The DC A-G (tip to ground) volt loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
the measurement is not…
Enumeration
Enumerated Values:
1notRun
3failMeasurementNotReported
4failMeasurementReported
7passMeasurementNotReported
8passMeasurementReported
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.37
hwONTPotsTestLoopDCBGVoltResult
The DC B-G (ring to ground) volt loop test result.
Options:
1. notRun(1) -a test does not run.

2. failMeasurementNotReported(3) -a test fails
the m…
Enumeration
Enumerated Values:
1notRun
3failMeasurementNotReported
4failMeasurementReported
7passMeasurementNotReported
8passMeasurementReported
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.38
hwONTPotsTestLoopACAGVoltResult
The AC A-G (tip to ground) volt loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
the measurement is not…
Enumeration
Enumerated Values:
1notRun
3failMeasurementNotReported
4failMeasurementReported
7passMeasurementNotReported
8passMeasurementReported
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.39
hwONTPotsTestLoopACBGVoltResult
The AC B-G (ring to ground) volt loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
the measurement is no…
Enumeration
Enumerated Values:
1notRun
3failMeasurementNotReported
4failMeasurementReported
7passMeasurementNotReported
8passMeasurementReported
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.40
hwONTPotsTestLoopResistanceAGResult
The A-G (ring to ground) resistance loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
the measurement is…
Enumeration
Enumerated Values:
1notRun
3failMeasurementNotReported
4failMeasurementReported
7passMeasurementNotReported
8passMeasurementReported
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.41
hwONTPotsTestLoopResistanceBGResult
The B-G (ring to ground) resistance loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
the measurement is…
Enumeration
Enumerated Values:
1notRun
3failMeasurementNotReported
4failMeasurementReported
7passMeasurementNotReported
8passMeasurementReported
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.42
hwONTPotsTestLoopResistanceABResult
The A-B (tip to ring) resistance loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
the measurement is no…
Enumeration
Enumerated Values:
1notRun
3failMeasurementNotReported
4failMeasurementReported
7passMeasurementNotReported
8passMeasurementReported
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.43
hwONTPotsTestLoopRingerLoadTestResult
The ringer load Loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
the measurement is not reported
3. fai…
Enumeration
Enumerated Values:
1notRun
3failMeasurementNotReported
4failMeasurementReported
7passMeasurementNotReported
8passMeasurementReported
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.44
hwONTPotsTestDrawDialToneTimeValue
The draw dial tone test result. Valid only if value of hwONTPotsTestDrawDialToneResult
is couldNotDraw2(4), slowDraw2(6) or pass2(8).
Unit: 100ms.
Step: 100ms.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.45
hwONTPotsTestBreakDialToneTimeValue
The break dial tone test result. Valid only if value of hwONTPotsTestBreakDialToneResult
is couldNotDraw2(4), slowDraw2(6) or pass2(8).
Unit: 100ms.
Step: 100 ms.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.46
hwONTPotsTestQuietEnergyValue
The quiet energy test result. Valid only if value of hwONTPotsTestQuietEnergyResult
is failMeasurementReported(4) or passMeasurementReported(8).
Values:
0-90 : 0 dBm0 to -90 dBm0
Step: 1 dBm0
Integer32
Constraints:
range: 0-90
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.47
hwONTPotsTestDialToneEnergyValue
The dial energy test result. Valid only if value of hwONTPotsTestDialToneEnergyResult
is failMeasurementReported(4) or passMeasurementReported(8).
Values:
0-255 : 0 dBm0 to -25.5 dBm0
Values above 0 dBm0 are reported as…
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.48
hwONTPotsTestLoopDCAGVoltValue
The DC A-G(Tip-ground) volt Loop test result or Subscriber line test result.
2s complement, resolution 1V. Valid only if value of hwONTPotsTestLoopDCAGVoltResult
is failMeasurementReported(4) or passMeasurementReported(…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.49
hwONTPotsTestLoopDCBGVoltValue
The DC B-G(Ring-ground) volt Loop test result or Subscriber line test result.
2s complement, resolution 1V. Valid only if value of hwONTPotsTestLoopDCBGVoltResult
is failMeasurementReported(4) or passMeasurementReported…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.50
hwONTPotsTestLoopACAGVoltValue
The AC A-G(Tip-ground) volt Loop test result or Subscriber line test result.
Valid only if value of hwONTPotsTestLoopACAGVoltResult is failMeasurementReported(4)
or passMeasurementReported(8) when loop tested.
Valid onl…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.51
hwONTPotsTestLoopACBGVoltValue
The AC B-G(Ring-ground) volt Loop test result or Subscriber line test result.
Valid only if value of hwONTPotsTestLoopACBGVoltResult is failMeasurementReported(4)
or passMeasurementReported(8) when loop tested.
Valid on…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.52
hwONTPotsTestLoopResistanceAGValue
The A-G (tip to ground) resistance loop test result or Subscriber line test result.
Unit: kilohm.
Infinite resistance: 65535.
Valid only if value of hwONTPotsTestLoopResistanceAGResult is
failMeasurementReported(4) or …
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.53
hwONTPotsTestLoopResistanceBGValue
The B-G (ring to ground) resistance loop test result or Subscriber line test result.
Unit: kilohm.
Infinite resistance: 65535.
Valid only if value of hwONTPotsTestLoopResistanceAGResult is
failMeasurementReported(4) or…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.54
hwONTPotsTestLoopResistanceABValue
The A-B (tip to ring) resistance loop test result or Subscriber line test result.
Unit: kilohm.
Infinite resistance: 65535.
Valid only if value of hwONTPotsTestLoopResistanceAGResult is
failMeasurementReported(4) or pa…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.55
hwONTPotsTestLoopRingerLoadTestValue
The ringer load test result. Valid only if value of hwONTPotsTestLoopRingerLoadTestResult
is failMeasurementReported(4) or passMeasurementReported(8).
Unit: 0.1 REN.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.56
hwONTPotsTestSubscriberLineTestResult
The subscriber line test result.
Options:
1. normal(1) -subscriber line test normal
2. acCurrentAbnormal(12) -AC current abnormal
3. dcCurrentAbnormal(13) -DC current abn…
Enumeration
Enumerated Values:
-1invalid
1normal
12acCurrentAbnormal
13dcCurrentAbnormal
14loopCurrentAbnormal
15loopResistanceAbnormal
16insulatingResistanceAbnormal
17capacitanceAbnormal
18impedanceAbnormal
22insulatingNotGood
23brokenLines
24lineMixing
25connectedToGround
26abLinereversal
27lineLeaking
28phoneDisconnect
29testTimeout
30testFailed
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.57
hwONTPotsTestLoopDCABVoltValue
The DC A-B (tip-Ring) volt result of subscriber line test.
Unit: volt.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.58
hwONTPotsTestLoopACABVoltValue
The AC A-B (Tip-Ring) volt result of subscriber line test.
Unit: volt.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.59
hwONTPotsTestLoopAGCapacitanceValue
The A->G (Tip-Ground) capacitance result of subscriber line test.
Unit: nF
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.60
hwONTPotsTestLoopBGCapacitanceValue
The B->G (Ring-Ground) capacitance result of subscriber line test.
Unit: nF
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.61
hwONTPotsTestLoopABCapacitanceValue
The A->B (Tip-Ring) capacitance result of subscriber line test.
Unit: nF
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.62
hwONTPotsTestLoopDCAGVoltCompensativeValue
The DC A->G (Tip-Ground) volt compensative result of subscriber line test.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.63
hwONTPotsTestLoopDCBGVoltCompensativeValue
The DC B->G (Ring-Ground) volt compensative result of subscriber line test.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.64
hwONTPotsTestLoopDCABVoltCompensativeValue
The DC A->B (Tip-Ring) volt compensative result of subscriber line test.
Unit: mV
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.65
hwONTPotsTestLoopACAGVoltCompensativeValue
The AC A->G (Tip-Ground) volt compensative result of subscriber line test.
Unit: mVrms
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.66
hwONTPotsTestLoopACBGVoltCompensativeValue
The AC B->G (Ring-Ground) volt compensative result of subscriber line test.
Unit: mVrms
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.67
hwONTPotsTestLoopACABVoltCompensativeValue
The AC A->B (Tip-Ring) volt compensative result of subscriber line test.
Unit: mVrms
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.68
hwONTPotsTestLoopResistanceAGCompensativeValue
The A-G (tip to ground) resistance compensative result of subscriber line test.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.69
hwONTPotsTestLoopResistanceBGCompensativeValue
The B-G (Ring to ground) resistance compensative result of subscriber line test.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.70
hwONTPotsTestLoopResistanceABCompensativeValue
The A-B (tip to Ring) resistance compensative result of subscriber line test.
Unit: ohm
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.71
.1.3.6.1.4.1.2011.6.21.1.1.1.11 · 1 row entry · 2 columns
This table is used to query the ports under a test by board.
The indexes of this table are hwFrameIndex and hwSlotIndex.
hwPortTestingListOprEntry entry .1.3.6.1.4.1.2011.6.21.1.1.1.11.1
This table is used to query the ports under a test by board.
The indexes of this entry are hwFrameIndex and hwSlotIndex.
Indexes
HUAWEI-DEVICE-MIBhwFrameIndex HUAWEI-DEVICE-MIBhwSlotIndex
Column Syntax OID
hwMeltTestingPortList
List of ports under a MELT test on a board.
The result is analyzed as follow: If a bit in the bit string is set to 1, it indicates that the corresponding port is under a MELT test.
For example, if port 8 is under a MELT…
Bits
Enumerated Values:
0port0
1port1
2port2
3port3
4port4
5port5
6port6
7port7
8port8
9port9
10port10
11port11
12port12
13port13
14port14
15port15
16port16
17port17
18port18
19port19
20port20
21port21
22port22
23port23
24port24
25port25
26port26
27port27
28port28
29port29
30port30
31port31
32port32
33port33
34port34
35port35
36port36
37port37
38port38
39port39
40port40
41port41
42port42
43port43
44port44
45port45
46port46
47port47
48port48
49port49
50port50
51port51
52port52
53port53
54port54
55port55
56port56
57port57
58port58
59port59
60port60
61port61
62port62
63port63
.1.3.6.1.4.1.2011.6.21.1.1.1.11.1.1
hwSearchToneTestingPortList
List of ports under a searching tone test on a board.
The result is analyzed as follow: If a bit in the bit string is set to 1, it indicates that the corresponding port is under a searching tone test.
For example, if po…
Bits
Enumerated Values:
0port0
1port1
2port2
3port3
4port4
5port5
6port6
7port7
8port8
9port9
10port10
11port11
12port12
13port13
14port14
15port15
16port16
17port17
18port18
19port19
20port20
21port21
22port22
23port23
24port24
25port25
26port26
27port27
28port28
29port29
30port30
31port31
32port32
33port33
34port34
35port35
36port36
37port37
38port38
39port39
40port40
41port41
42port42
43port43
44port44
45port45
46port46
47port47
48port48
49port49
50port50
51port51
52port52
53port53
54port54
55port55
56port56
57port57
58port58
59port59
60port60
61port61
62port62
63port63
.1.3.6.1.4.1.2011.6.21.1.1.1.11.1.2
.1.3.6.1.4.1.2011.6.21.1.1.1.12 · 1 row entry · 4 columns
This table is used for enabling the wetting current by setting the wetting current's
working voltage, maximum voltage and slope.
The index of this table is ifindex.
hwWettingCurrentOprEntry entry .1.3.6.1.4.1.2011.6.21.1.1.1.12.1
This table is used for enabling the wetting current by setting the wetting current's
working voltage, maximum voltage and slope.
The index of this entry is ifindex.
Indexes
IF-MIBifIndex
Column Syntax OID
hwWettingCurrentOprStatus
Wetting Current operation type.
Options:
1. enabled(1) -enable a wetting current port
2. disabled(2) -disable a wetting current port
3. invalid(-1) -invalid value
enabled(1) and disabled(2) options are avail…
Enumerationr/w
Enumerated Values:
-1invalid
1enabled
2disabled
.1.3.6.1.4.1.2011.6.21.1.1.1.12.1.1
hwWettingCurrentOprWorkingVoltage
Indicates the working voltage of a wetting current port.
Options:
1. -1 -Invalid value
2. 1..120 -Valid value range
Default: 90
Unit: volt
Integer32r/w
Constraints:
range: -1--1
range: 1-120
.1.3.6.1.4.1.2011.6.21.1.1.1.12.1.2
hwWettingCurrentOprMaximumVoltage
Indicates the maximum voltage of a wetting current port.
Options:
1. -1 -Invalid value
2. 1..120 -Valid value range
Default: 30
Unit: volt
Integer32r/w
Constraints:
range: -1--1
range: 1-120
.1.3.6.1.4.1.2011.6.21.1.1.1.12.1.3
hwWettingCurrentOprSlope
Indicates the slope of a wetting current port.
Options:
1. -1 -Invalid value
2. 200..20000 -Valid value range
Default: 200
Unit: volt per second
Integer32r/w
Constraints:
range: -1--1
range: 200-20000
.1.3.6.1.4.1.2011.6.21.1.1.1.12.1.4
.1.3.6.1.4.1.2011.6.21.1.1.1.13 · 1 row entry · 5 columns
This table is used for manually starting a MELT chip status check on an xDSL board, and obtaining the status of the MELT chip.
The indexes of this table are hwFrameIndex and hwSlotIndex.
hwLoopLineTestMeltChipStateEntry entry .1.3.6.1.4.1.2011.6.21.1.1.1.13.1
This table is used for manually starting a MELT chip status check on an xDSL board, and obtaining the status of the MELT chip.
The indexes of this table are hwFrameIndex and hwSlotIndex.
Indexes
HUAWEI-DEVICE-MIBhwFrameIndex HUAWEI-DEVICE-MIBhwSlotIndex
Column Syntax OID
hwBoardMeltChipStateCheckConfig
Enables the melt chip status check of the board.
Options:
1. enabled(1) -Enables the melt chip status check
2. invalid(-1) -Invalid value
enabled(1) option is available in the set operation.
invalid(-1) option …
Enumerationr/w
Enumerated Values:
-1invalid
1enabled
.1.3.6.1.4.1.2011.6.21.1.1.1.13.1.1
hwBoardMeltChipStateCheckResult
Melt chip status check result.
Options:
1. success(1) -Melt chip status check success
2. fail(2) -Melt chip status check fail
Enumeration
Enumerated Values:
1success
2fail
.1.3.6.1.4.1.2011.6.21.1.1.1.13.1.2
hwPortMeltChipStateList
Lists the status of the MELT chip for xDSL port.
The result is analyzed as follow: If a bit in the bit string is set to 1, the MELT chip of a port is faulty.
For example, if the MELT chip of port 8 is faulty, the eight…
Bits
Enumerated Values:
0port0
1port1
2port2
3port3
4port4
5port5
6port6
7port7
8port8
9port9
10port10
11port11
12port12
13port13
14port14
15port15
16port16
17port17
18port18
19port19
20port20
21port21
22port22
23port23
24port24
25port25
26port26
27port27
28port28
29port29
30port30
31port31
32port32
33port33
34port34
35port35
36port36
37port37
38port38
39port39
40port40
41port41
42port42
43port43
44port44
45port45
46port46
47port47
48port48
49port49
50port50
51port51
52port52
53port53
54port54
55port55
56port56
57port57
58port58
59port59
60port60
61port61
62port62
63port63
.1.3.6.1.4.1.2011.6.21.1.1.1.13.1.3
hwBoardMeltChipStateCheckDCVolUpperLimit
Indicates the upper limit of dc-voltage for melt chip status check.
Options:
1. -60..60 -Valid value range
2. 2147483647 -Invalid value
Default: 1
Unit: volt
Integer32r/w
Constraints:
range: -60-60
range: 2147483647-2147483647
.1.3.6.1.4.1.2011.6.21.1.1.1.13.1.4
hwBoardMeltChipStateCheckDCVolLowerLimit
Indicates the lower limit of dc-voltage for melt chip status check.
Options:
1. -60..60 -Valid value range
2. 2147483647 -Invalid value
Default: -1
Unit: volt
Integer32r/w
Constraints:
range: -60-60