hwLoopLineTestCalibrationEntry
HUAWEI-COMMTEST-MIB ·
.1.3.6.1.4.1.2011.6.21.1.1.1.7.1
Object
row
This table provides the test calibration data of a line. Before delivery, each port is performed with a test in which no user is connected to the port and the test result is saved as standard data. The standard data is used for calibrating the test result of tests in the actual environment. The index of this entry is ifindex.
Context
- MIB
- HUAWEI-COMMTEST-MIB
- OID
.1.3.6.1.4.1.2011.6.21.1.1.1.7.1- Type
- row
- Status
- current
- Parent
- hwLoopLineTestCalibrationTable
- Table
- hwLoopLineTestCalibrationTable
- Children
- 3
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwLoopLineTestAGCalibration Indicates the test calibration data of A->Ground capacitance.
Unit: nF | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.7.1.1 |
| hwLoopLineTestBGCalibration Indicates the test calibration data of B->Ground capacitance.
Unit: nF | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.7.1.2 |
| hwLoopLineTestABCalibration Indicates the test calibration data of A->B capacitance.
Unit: nF | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.7.1.3 |