hwONTPotsTestDialType
HUAWEI-COMMTEST-MIB ·
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.11
Object
column
r/w
Enumeration
The dialling type of dialling tone test. Options: 1. dtmf(1) -dtmf type 2. pulse(2) -pulse type
Context
- MIB
- HUAWEI-COMMTEST-MIB
- OID
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.11- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwONTPotsTestOprEntry
- Table
- hwONTPotsTestOprTable
- Siblings
- 70
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | dtmf |
2 | pulse |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwONTPotsTestONTIndex ONT ID. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.1 |
| hwONTPotsTestDtmfDigit DTMF test number.
Options:
1. zero(1) -the test number is 0
2. one(2) -the test number is 1
3. two(3) -the test number is 2
4. three(4) -the test … | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.10 |
| hwONTPotsTestDialToneFreq1 The frequency1 in the dialling tone test.
0 -unused
Unit: Hz | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.12 |
| hwONTPotsTestDialToneFreq2 The frequency2 in the dialling tone test.
0 -unused
Unit: Hz | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.13 |
| hwONTPotsTestDialToneFreq3 The frequency3 in the dialling tone test.
0 -unused
Unit: Hz | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.14 |
| hwONTPotsTestDialToneEnergyThreshold The value of energy threshold in the dialling tone test.
Valid value:
1. 0x00: unspecified
2. 0x01-0xFD: -0.1 dBm0 to -25.3 dBm0
Unit: 0.1 dBm0 | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.15 |
| hwONTPotsTestIdleChannelEnergyThreshold The value of energy threshold in the dialling tone test when the line
is in the idle state.
Valid value:
1. 0x00: unspecified
2. 0x01-0x5A: -1 dBm0 to -90 dBm0
Unit: 1 dBm0 | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.16 |
| hwONTPotsTestDCHazardousVoltThreshold The value of DC voltage threshold in the hazardous potential test.
0x00 -unspecified
Unit: volt | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.17 |
| hwONTPotsTestACHazardousVoltThreshold The value of AC voltage threshold in the hazardous potential test.
0x00 -unspecified
Unit: volt. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.18 |
| hwONTPotsTestDCForeignVoltThreshold The value of DC voltage threshold in the foreign volt test.
0x00 -unspecified
Unit: volt | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.19 |
| hwONTPotsTestONTPstnPortIndex ONT port ID. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.2 |
| hwONTPotsTestACForeignVoltThreshold The value of AC voltage threshold in the foreign volt test.
0x00 -unspecified
Unit: volt | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.20 |
| hwONTPotsTestAGBGResistanceThreshold The resistance (tip to ground, ring to ground) threshold in the
resistive faults test.
0x00 -unspecified
Unit: kilohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.21 |
| hwONTPotsTestABResistanceThreshold The resistance (tip to ring) threshold in the resistive faults test.
0x00 -unspecified
Unit: kilohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.22 |
| hwONTPotsTestRingerEquivMinThreshold Ringer equivalence minimum threshold.
0x00 -unspecified
Unit: 0.01 REN | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.23 |
| hwONTPotsTestRingerEquivMaxThreshold Ringer equivalence maximum threshold.
0x00 -unspecified
Unit: 0.01 REN | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.24 |
| hwONTPotsTestMLTResult MLT qualitative test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.25 |
| hwONTPotsTestHazardousVoltResult Hazardous volt test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.26 |
| hwONTPotsTestEMFResult EMF test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.27 |
| hwONTPotsTestResistacneResult Resistacne test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.28 |
| hwONTPotsTestOffHookResult The off-hook test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.29 |
| hwONTPotsTestOprType POTS port line Test-operation type.
Options:
1. stop(1) -stop a POTS port line test
2. start(2) -start a POTS port line test
3. invalid(-1) -invalid value | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.3 |
| hwONTPotsTestRingerResult Ringer test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.30 |
| hwONTPotsTestNT1DCSignalResult NT1 DC Signal test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.31 |
| hwONTPotsTestSelfTestResult Self test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run
3. notCompleted(3) -a test is not complete yet | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.32 |
| hwONTPotsTestDrawDialToneResult Draw dialling tone test result.
Options:
1. notRun(1) -a test does not run
2. couldNotDraw1(3) -a test fails to draw
3. couldNotDraw2(4) -a test fails … | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.33 |
| hwONTPotsTestBreakDialToneResult The break dialling tone test result.
Options:
1. notRun(1) -a test does not run
2. couldNotDraw1(3) -a test fails to draw
3. couldNotDraw2(4) -a test … | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.34 |
| hwONTPotsTestQuietEnergyResult The quiet energy test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
th… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.35 |
| hwONTPotsTestDialToneEnergyResult The dialling tone energy test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.36 |
| hwONTPotsTestLoopDCAGVoltResult The DC A-G (tip to ground) volt loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.37 |
| hwONTPotsTestLoopDCBGVoltResult The DC B-G (ring to ground) volt loop test result.
Options:
1. notRun(1) -a test does not run.
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.38 |
| hwONTPotsTestLoopACAGVoltResult The AC A-G (tip to ground) volt loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.39 |
| hwONTPotsTestItem POTS port line test item.
Options:
1. allMLTTests(1) -outdoor connection test
2. hazardousPotential(2) -hazardous potential test
3. foreignEMF(3) … | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.4 |
| hwONTPotsTestLoopACBGVoltResult The AC B-G (ring to ground) volt loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.40 |
| hwONTPotsTestLoopResistanceAGResult The A-G (ring to ground) resistance loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.41 |
| hwONTPotsTestLoopResistanceBGResult The B-G (ring to ground) resistance loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.42 |
| hwONTPotsTestLoopResistanceABResult The A-B (tip to ring) resistance loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.43 |
| hwONTPotsTestLoopRingerLoadTestResult The ringer load Loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.44 |
| hwONTPotsTestDrawDialToneTimeValue The draw dial tone test result. Valid only if value of hwONTPotsTestDrawDialToneResult
is couldNotDraw2(4), slowDraw2(6) or pass2(8).
Unit: 100ms.
Step: 100ms. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.45 |
| hwONTPotsTestBreakDialToneTimeValue The break dial tone test result. Valid only if value of hwONTPotsTestBreakDialToneResult
is couldNotDraw2(4), slowDraw2(6) or pass2(8).
Unit: 100ms.
Step: 100 ms. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.46 |
| hwONTPotsTestQuietEnergyValue The quiet energy test result. Valid only if value of hwONTPotsTestQuietEnergyResult
is failMeasurementReported(4) or passMeasurementReported(8).
Values:
0-90 : 0 dBm0 to -90 dBm0
… | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.47 |
| hwONTPotsTestDialToneEnergyValue The dial energy test result. Valid only if value of hwONTPotsTestDialToneEnergyResult
is failMeasurementReported(4) or passMeasurementReported(8).
Values:
0-255 : 0 dBm0 to -25.5 … | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.48 |
| hwONTPotsTestLoopDCAGVoltValue The DC A-G(Tip-ground) volt Loop test result or Subscriber line test result.
2s complement, resolution 1V. Valid only if value of hwONTPotsTestLoopDCAGVoltResult
is failMeasuremen… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.49 |
| hwONTPotsTestBusyProcFlag Test mode when a line is busy.
Options:
1. cancel(1) -deny a test if a line is busy
2. force(2) -forced mode | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.5 |
| hwONTPotsTestLoopDCBGVoltValue The DC B-G(Ring-ground) volt Loop test result or Subscriber line test result.
2s complement, resolution 1V. Valid only if value of hwONTPotsTestLoopDCBGVoltResult
is failMeasureme… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.50 |
| hwONTPotsTestLoopACAGVoltValue The AC A-G(Tip-ground) volt Loop test result or Subscriber line test result.
Valid only if value of hwONTPotsTestLoopACAGVoltResult is failMeasurementReported(4)
or passMeasuremen… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.51 |
| hwONTPotsTestLoopACBGVoltValue The AC B-G(Ring-ground) volt Loop test result or Subscriber line test result.
Valid only if value of hwONTPotsTestLoopACBGVoltResult is failMeasurementReported(4)
or passMeasureme… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.52 |
| hwONTPotsTestLoopResistanceAGValue The A-G (tip to ground) resistance loop test result or Subscriber line test result.
Unit: kilohm.
Infinite resistance: 65535.
Valid only if value of hwONTPotsTestLoopResistanceAGR… | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.53 |
| hwONTPotsTestLoopResistanceBGValue The B-G (ring to ground) resistance loop test result or Subscriber line test result.
Unit: kilohm.
Infinite resistance: 65535.
Valid only if value of hwONTPotsTestLoopResistanceAG… | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.54 |
| hwONTPotsTestLoopResistanceABValue The A-B (tip to ring) resistance loop test result or Subscriber line test result.
Unit: kilohm.
Infinite resistance: 65535.
Valid only if value of hwONTPotsTestLoopResistanceAGRes… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.55 |
| hwONTPotsTestLoopRingerLoadTestValue The ringer load test result. Valid only if value of hwONTPotsTestLoopRingerLoadTestResult
is failMeasurementReported(4) or passMeasurementReported(8).
Unit: 0.1 REN. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.56 |
| hwONTPotsTestSubscriberLineTestResult The subscriber line test result.
Options:
1. normal(1) -subscriber line test normal
2. acCurrentAbnormal(12) -AC current abnormal
3. dcCurrent… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.57 |
| hwONTPotsTestLoopDCABVoltValue The DC A-B (tip-Ring) volt result of subscriber line test.
Unit: volt. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.58 |
| hwONTPotsTestLoopACABVoltValue The AC A-B (Tip-Ring) volt result of subscriber line test.
Unit: volt. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.59 |
| hwONTPotsTestT1Threshold Slow dial tone threshold.
Options:
1. 0 -Invalid value. It indicates that an ONT will use its default value
2. 100..6000 -Valid value range | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.6 |
| hwONTPotsTestLoopAGCapacitanceValue The A->G (Tip-Ground) capacitance result of subscriber line test.
Unit: nF | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.60 |
| hwONTPotsTestLoopBGCapacitanceValue The B->G (Ring-Ground) capacitance result of subscriber line test.
Unit: nF | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.61 |
| hwONTPotsTestLoopABCapacitanceValue The A->B (Tip-Ring) capacitance result of subscriber line test.
Unit: nF | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.62 |
| hwONTPotsTestLoopDCAGVoltCompensativeValue The DC A->G (Tip-Ground) volt compensative result of subscriber line test.
Unit: mV | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.63 |
| hwONTPotsTestLoopDCBGVoltCompensativeValue The DC B->G (Ring-Ground) volt compensative result of subscriber line test.
Unit: mV | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.64 |
| hwONTPotsTestLoopDCABVoltCompensativeValue The DC A->B (Tip-Ring) volt compensative result of subscriber line test.
Unit: mV | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.65 |
| hwONTPotsTestLoopACAGVoltCompensativeValue The AC A->G (Tip-Ground) volt compensative result of subscriber line test.
Unit: mVrms | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.66 |
| hwONTPotsTestLoopACBGVoltCompensativeValue The AC B->G (Ring-Ground) volt compensative result of subscriber line test.
Unit: mVrms | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.67 |
| hwONTPotsTestLoopACABVoltCompensativeValue The AC A->B (Tip-Ring) volt compensative result of subscriber line test.
Unit: mVrms | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.68 |
| hwONTPotsTestLoopResistanceAGCompensativeValue The A-G (tip to ground) resistance compensative result of subscriber line test.
Unit: ohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.69 |
| hwONTPotsTestT2Threshold No dial tone threshold.
Options:
1. 0 -Invalid value. It indicates that an ONT will use its default value
2. 1000..10000 -Valid value range | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.7 |
| hwONTPotsTestLoopResistanceBGCompensativeValue The B-G (Ring to ground) resistance compensative result of subscriber line test.
Unit: ohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.70 |
| hwONTPotsTestLoopResistanceABCompensativeValue The A-B (tip to Ring) resistance compensative result of subscriber line test.
Unit: ohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.71 |
| hwONTPotsTestT3Threshold Slow break dial tone threshold.
Options:
1. 0 -Invalid value. It indicates that an ONT will use its default value
2. 100..3000 -Valid value range | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.8 |
| hwONTPotsTestT4Threshold No break dial tone threshold.
Options:
1. 0 -Invalid value. It indicates that an ONT will use its default value
2. 1000..3000 -Valid value range | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.9 |