hwONTPotsTestLoopACAGVoltValue
HUAWEI-COMMTEST-MIB ·
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.51
Object
column
SNMPv2-SMIInteger32
The AC A-G(Tip-ground) volt Loop test result or Subscriber line test result. Valid only if value of hwONTPotsTestLoopACAGVoltResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test. Unit: volt.
Context
- MIB
- HUAWEI-COMMTEST-MIB
- OID
.1.3.6.1.4.1.2011.6.21.1.1.1.10.1.51- Type
- column
- Access
- readonly
- Status
- current
- Parent
- hwONTPotsTestOprEntry
- Table
- hwONTPotsTestOprTable
- Siblings
- 70
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwONTPotsTestONTIndex ONT ID. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.1 |
| hwONTPotsTestDtmfDigit DTMF test number.
Options:
1. zero(1) -the test number is 0
2. one(2) -the test number is 1
3. two(3) -the test number is 2
4. three(4) -the test … | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.10 |
| hwONTPotsTestDialType The dialling type of dialling tone test.
Options:
1. dtmf(1) -dtmf type
2. pulse(2) -pulse type | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.11 |
| hwONTPotsTestDialToneFreq1 The frequency1 in the dialling tone test.
0 -unused
Unit: Hz | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.12 |
| hwONTPotsTestDialToneFreq2 The frequency2 in the dialling tone test.
0 -unused
Unit: Hz | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.13 |
| hwONTPotsTestDialToneFreq3 The frequency3 in the dialling tone test.
0 -unused
Unit: Hz | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.14 |
| hwONTPotsTestDialToneEnergyThreshold The value of energy threshold in the dialling tone test.
Valid value:
1. 0x00: unspecified
2. 0x01-0xFD: -0.1 dBm0 to -25.3 dBm0
Unit: 0.1 dBm0 | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.15 |
| hwONTPotsTestIdleChannelEnergyThreshold The value of energy threshold in the dialling tone test when the line
is in the idle state.
Valid value:
1. 0x00: unspecified
2. 0x01-0x5A: -1 dBm0 to -90 dBm0
Unit: 1 dBm0 | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.16 |
| hwONTPotsTestDCHazardousVoltThreshold The value of DC voltage threshold in the hazardous potential test.
0x00 -unspecified
Unit: volt | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.17 |
| hwONTPotsTestACHazardousVoltThreshold The value of AC voltage threshold in the hazardous potential test.
0x00 -unspecified
Unit: volt. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.18 |
| hwONTPotsTestDCForeignVoltThreshold The value of DC voltage threshold in the foreign volt test.
0x00 -unspecified
Unit: volt | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.19 |
| hwONTPotsTestONTPstnPortIndex ONT port ID. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.2 |
| hwONTPotsTestACForeignVoltThreshold The value of AC voltage threshold in the foreign volt test.
0x00 -unspecified
Unit: volt | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.20 |
| hwONTPotsTestAGBGResistanceThreshold The resistance (tip to ground, ring to ground) threshold in the
resistive faults test.
0x00 -unspecified
Unit: kilohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.21 |
| hwONTPotsTestABResistanceThreshold The resistance (tip to ring) threshold in the resistive faults test.
0x00 -unspecified
Unit: kilohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.22 |
| hwONTPotsTestRingerEquivMinThreshold Ringer equivalence minimum threshold.
0x00 -unspecified
Unit: 0.01 REN | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.23 |
| hwONTPotsTestRingerEquivMaxThreshold Ringer equivalence maximum threshold.
0x00 -unspecified
Unit: 0.01 REN | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.24 |
| hwONTPotsTestMLTResult MLT qualitative test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.25 |
| hwONTPotsTestHazardousVoltResult Hazardous volt test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.26 |
| hwONTPotsTestEMFResult EMF test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.27 |
| hwONTPotsTestResistacneResult Resistacne test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.28 |
| hwONTPotsTestOffHookResult The off-hook test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.29 |
| hwONTPotsTestOprType POTS port line Test-operation type.
Options:
1. stop(1) -stop a POTS port line test
2. start(2) -start a POTS port line test
3. invalid(-1) -invalid value | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.3 |
| hwONTPotsTestRingerResult Ringer test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.30 |
| hwONTPotsTestNT1DCSignalResult NT1 DC Signal test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.31 |
| hwONTPotsTestSelfTestResult Self test result.
Options:
1. failed(1) -a test fails
2. passOrNotRun(2) -a test passes or the test does not run
3. notCompleted(3) -a test is not complete yet | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.32 |
| hwONTPotsTestDrawDialToneResult Draw dialling tone test result.
Options:
1. notRun(1) -a test does not run
2. couldNotDraw1(3) -a test fails to draw
3. couldNotDraw2(4) -a test fails … | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.33 |
| hwONTPotsTestBreakDialToneResult The break dialling tone test result.
Options:
1. notRun(1) -a test does not run
2. couldNotDraw1(3) -a test fails to draw
3. couldNotDraw2(4) -a test … | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.34 |
| hwONTPotsTestQuietEnergyResult The quiet energy test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
th… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.35 |
| hwONTPotsTestDialToneEnergyResult The dialling tone energy test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.36 |
| hwONTPotsTestLoopDCAGVoltResult The DC A-G (tip to ground) volt loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.37 |
| hwONTPotsTestLoopDCBGVoltResult The DC B-G (ring to ground) volt loop test result.
Options:
1. notRun(1) -a test does not run.
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.38 |
| hwONTPotsTestLoopACAGVoltResult The AC A-G (tip to ground) volt loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.39 |
| hwONTPotsTestItem POTS port line test item.
Options:
1. allMLTTests(1) -outdoor connection test
2. hazardousPotential(2) -hazardous potential test
3. foreignEMF(3) … | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.4 |
| hwONTPotsTestLoopACBGVoltResult The AC B-G (ring to ground) volt loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.40 |
| hwONTPotsTestLoopResistanceAGResult The A-G (ring to ground) resistance loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.41 |
| hwONTPotsTestLoopResistanceBGResult The B-G (ring to ground) resistance loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.42 |
| hwONTPotsTestLoopResistanceABResult The A-B (tip to ring) resistance loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.43 |
| hwONTPotsTestLoopRingerLoadTestResult The ringer load Loop test result.
Options:
1. notRun(1) -a test does not run
2. failMeasurementNotReported(3) -a test fails
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.44 |
| hwONTPotsTestDrawDialToneTimeValue The draw dial tone test result. Valid only if value of hwONTPotsTestDrawDialToneResult
is couldNotDraw2(4), slowDraw2(6) or pass2(8).
Unit: 100ms.
Step: 100ms. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.45 |
| hwONTPotsTestBreakDialToneTimeValue The break dial tone test result. Valid only if value of hwONTPotsTestBreakDialToneResult
is couldNotDraw2(4), slowDraw2(6) or pass2(8).
Unit: 100ms.
Step: 100 ms. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.46 |
| hwONTPotsTestQuietEnergyValue The quiet energy test result. Valid only if value of hwONTPotsTestQuietEnergyResult
is failMeasurementReported(4) or passMeasurementReported(8).
Values:
0-90 : 0 dBm0 to -90 dBm0
… | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.47 |
| hwONTPotsTestDialToneEnergyValue The dial energy test result. Valid only if value of hwONTPotsTestDialToneEnergyResult
is failMeasurementReported(4) or passMeasurementReported(8).
Values:
0-255 : 0 dBm0 to -25.5 … | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.48 |
| hwONTPotsTestLoopDCAGVoltValue The DC A-G(Tip-ground) volt Loop test result or Subscriber line test result.
2s complement, resolution 1V. Valid only if value of hwONTPotsTestLoopDCAGVoltResult
is failMeasuremen… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.49 |
| hwONTPotsTestBusyProcFlag Test mode when a line is busy.
Options:
1. cancel(1) -deny a test if a line is busy
2. force(2) -forced mode | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.5 |
| hwONTPotsTestLoopDCBGVoltValue The DC B-G(Ring-ground) volt Loop test result or Subscriber line test result.
2s complement, resolution 1V. Valid only if value of hwONTPotsTestLoopDCBGVoltResult
is failMeasureme… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.50 |
| hwONTPotsTestLoopACBGVoltValue The AC B-G(Ring-ground) volt Loop test result or Subscriber line test result.
Valid only if value of hwONTPotsTestLoopACBGVoltResult is failMeasurementReported(4)
or passMeasureme… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.52 |
| hwONTPotsTestLoopResistanceAGValue The A-G (tip to ground) resistance loop test result or Subscriber line test result.
Unit: kilohm.
Infinite resistance: 65535.
Valid only if value of hwONTPotsTestLoopResistanceAGR… | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.53 |
| hwONTPotsTestLoopResistanceBGValue The B-G (ring to ground) resistance loop test result or Subscriber line test result.
Unit: kilohm.
Infinite resistance: 65535.
Valid only if value of hwONTPotsTestLoopResistanceAG… | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.54 |
| hwONTPotsTestLoopResistanceABValue The A-B (tip to ring) resistance loop test result or Subscriber line test result.
Unit: kilohm.
Infinite resistance: 65535.
Valid only if value of hwONTPotsTestLoopResistanceAGRes… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.55 |
| hwONTPotsTestLoopRingerLoadTestValue The ringer load test result. Valid only if value of hwONTPotsTestLoopRingerLoadTestResult
is failMeasurementReported(4) or passMeasurementReported(8).
Unit: 0.1 REN. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.56 |
| hwONTPotsTestSubscriberLineTestResult The subscriber line test result.
Options:
1. normal(1) -subscriber line test normal
2. acCurrentAbnormal(12) -AC current abnormal
3. dcCurrent… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.57 |
| hwONTPotsTestLoopDCABVoltValue The DC A-B (tip-Ring) volt result of subscriber line test.
Unit: volt. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.58 |
| hwONTPotsTestLoopACABVoltValue The AC A-B (Tip-Ring) volt result of subscriber line test.
Unit: volt. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.59 |
| hwONTPotsTestT1Threshold Slow dial tone threshold.
Options:
1. 0 -Invalid value. It indicates that an ONT will use its default value
2. 100..6000 -Valid value range | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.6 |
| hwONTPotsTestLoopAGCapacitanceValue The A->G (Tip-Ground) capacitance result of subscriber line test.
Unit: nF | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.60 |
| hwONTPotsTestLoopBGCapacitanceValue The B->G (Ring-Ground) capacitance result of subscriber line test.
Unit: nF | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.61 |
| hwONTPotsTestLoopABCapacitanceValue The A->B (Tip-Ring) capacitance result of subscriber line test.
Unit: nF | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.62 |
| hwONTPotsTestLoopDCAGVoltCompensativeValue The DC A->G (Tip-Ground) volt compensative result of subscriber line test.
Unit: mV | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.63 |
| hwONTPotsTestLoopDCBGVoltCompensativeValue The DC B->G (Ring-Ground) volt compensative result of subscriber line test.
Unit: mV | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.64 |
| hwONTPotsTestLoopDCABVoltCompensativeValue The DC A->B (Tip-Ring) volt compensative result of subscriber line test.
Unit: mV | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.65 |
| hwONTPotsTestLoopACAGVoltCompensativeValue The AC A->G (Tip-Ground) volt compensative result of subscriber line test.
Unit: mVrms | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.66 |
| hwONTPotsTestLoopACBGVoltCompensativeValue The AC B->G (Ring-Ground) volt compensative result of subscriber line test.
Unit: mVrms | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.67 |
| hwONTPotsTestLoopACABVoltCompensativeValue The AC A->B (Tip-Ring) volt compensative result of subscriber line test.
Unit: mVrms | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.68 |
| hwONTPotsTestLoopResistanceAGCompensativeValue The A-G (tip to ground) resistance compensative result of subscriber line test.
Unit: ohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.69 |
| hwONTPotsTestT2Threshold No dial tone threshold.
Options:
1. 0 -Invalid value. It indicates that an ONT will use its default value
2. 1000..10000 -Valid value range | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.7 |
| hwONTPotsTestLoopResistanceBGCompensativeValue The B-G (Ring to ground) resistance compensative result of subscriber line test.
Unit: ohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.70 |
| hwONTPotsTestLoopResistanceABCompensativeValue The A-B (tip to Ring) resistance compensative result of subscriber line test.
Unit: ohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.71 |
| hwONTPotsTestT3Threshold Slow break dial tone threshold.
Options:
1. 0 -Invalid value. It indicates that an ONT will use its default value
2. 100..3000 -Valid value range | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.8 |
| hwONTPotsTestT4Threshold No break dial tone threshold.
Options:
1. 0 -Invalid value. It indicates that an ONT will use its default value
2. 1000..3000 -Valid value range | column | Integer32 | .1.3.6.1.4.1.2011.6.21.1.1.1.10.1.9 |