VERTIV-V5-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
34
Rows
34
Columns
355
pduMainTable
table.1.3.6.1.4.1.21239.5.2.3.1
·
1 row entry
·
12 columns
PDU general information
Entry in the pduMainTable table: each entry contains an index and
other sensor details
other sensor details
Indexes
pduMainIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
pduMainIndex
Table entry index value
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.3.1.1.1 |
||||
|
pduMainSerial
Serial number
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.21239.5.2.3.1.1.2 |
||||
|
pduMainName
PDU name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.3.1.1.3 |
||||
|
pduMainLabel
PDU label (user-defined)
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.3.1.1.4 |
||||
|
pduMainAvail
Device availability:
0 = Unavailable 1 = Available 2 = Partially Unavailable |
SNMPv2-SMIGauge32 Textual Convention: SNMPv2-SMIGauge32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.21239.5.2.3.1.1.5 |
||||
|
pduMeterType
Current meter type:
0 = Wye 1 = Delta |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.3.1.1.6 |
||||
|
pduTotalName
Total name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.3.1.1.7 |
||||
|
pduTotalLabel
Total label (user-defined)
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.3.1.1.8 |
||||
|
pduTotalRealPower
PDU total real power
|
wattsUnsigned32 Constraints: range: 0-9999 |
.1.3.6.1.4.1.21239.5.2.3.1.1.9 |
||||
|
pduTotalApparentPower
PDU total apparent power
|
volt-ampsUnsigned32 Constraints: range: 0-9999 |
.1.3.6.1.4.1.21239.5.2.3.1.1.10 |
||||
|
pduTotalPowerFactor
PDU total power factor
|
%Unsigned32 Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.3.1.1.11 |
||||
|
pduTotalEnergy
PDU total accumulated energy in watt-hours
|
watt-hoursUnsigned32 Constraints: range: 0-9999000 |
.1.3.6.1.4.1.21239.5.2.3.1.1.12 |
pduPhaseTable
table.1.3.6.1.4.1.21239.5.2.3.2
·
1 row entry
·
12 columns
PDU phases information
Entry in the pduPhaseTable table: each entry contains an index and
other sensor details
other sensor details
Indexes
pduPhaseIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
pduPhaseIndex
Table entry index value
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.3.2.1.1 |
||||
|
pduPhaseName
PDU phase name (factory-assigned)
|
OctetString Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.3.2.1.2 |
||||
|
pduPhaseLabel
PDU phase label (user-defined)
|
OctetStringr/w Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.3.2.1.3 |
||||
|
pduPhaseVoltage
PDU phase voltage in tenths of a volt
|
decivolts (rms)Unsigned32 Constraints: range: 0-3100 |
.1.3.6.1.4.1.21239.5.2.3.2.1.4 |
||||
|
pduPhaseCurrent
PDU phase current reading in hundredths of an amp
|
centiamps (rms)Unsigned32 Constraints: range: 0-9900 |
.1.3.6.1.4.1.21239.5.2.3.2.1.8 |
||||
|
pduPhaseRealPower
Real power for phase in watts
|
wattsUnsigned32 Constraints: range: 0-9999 |
.1.3.6.1.4.1.21239.5.2.3.2.1.12 |
||||
|
pduPhaseApparentPower
Apparent power for phase in volt-amps
|
volt-ampsUnsigned32 Constraints: range: 0-9999 |
.1.3.6.1.4.1.21239.5.2.3.2.1.13 |
||||
|
pduPhasePowerFactor
Power factor for phase
|
%Unsigned32 Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.3.2.1.14 |
||||
|
pduPhaseEnergy
Accumulated energy for phase in watt-hours
|
watt-hoursUnsigned32 Constraints: range: 0-9999000 |
.1.3.6.1.4.1.21239.5.2.3.2.1.15 |
||||
|
pduPhaseBalance
Phase balance as percent
|
%Unsigned32 Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.3.2.1.17 |
||||
|
pduPhaseCurrentCrestFactor
Current crest factor for phase, in hundredths
|
Unsigned32 Constraints: range: 0-9999 |
.1.3.6.1.4.1.21239.5.2.3.2.1.19 |
||||
|
pduPhaseResCurrentDetected
Tells if residual current was detected. In normal operation, the value
will be false(2). |
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.3.2.1.20 |
pduBreakerTable
table.1.3.6.1.4.1.21239.5.2.3.3
·
1 row entry
·
11 columns
PDU breaker information
Entry in the pduBreakerTable table: each entry contains an index and
other sensor details
other sensor details
Indexes
pduBreakerIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
pduBreakerIndex
Table entry index value
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.3.3.1.1 |
||||
|
pduBreakerName
PDU breaker name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.3.3.1.2 |
||||
|
pduBreakerLabel
PDU breaker label (user-defined)
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.3.3.1.3 |
||||
|
pduBreakerCurrent
PDU breaker current reading in hundredths of an amp
|
centiamps (rms)Unsigned32 Constraints: range: 0-9900 |
.1.3.6.1.4.1.21239.5.2.3.3.1.4 |
||||
|
pduBreakerVoltage
PDU breaker voltage in tenths of a volt. This object may not exist on
all platforms, due to hardware differences. |
decivolts (rms)Unsigned32 Constraints: range: 0-3100 |
.1.3.6.1.4.1.21239.5.2.3.3.1.8 |
||||
|
pduBreakerRealPower
Real power for breaker in watts. This object may not exist on all
platforms, due to hardware differences. |
wattsUnsigned32 Constraints: range: 0-9999 |
.1.3.6.1.4.1.21239.5.2.3.3.1.12 |
||||
|
pduBreakerApparentPower
Apparent power for breaker in volt-amps. This object may not exist on
all platforms, due to hardware differences. |
volt-ampsUnsigned32 Constraints: range: 0-9999 |
.1.3.6.1.4.1.21239.5.2.3.3.1.13 |
||||
|
pduBreakerPowerFactor
Power factor for breaker. This object may not exist on all platforms,
due to hardware differences. |
%Unsigned32 Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.3.3.1.14 |
||||
|
pduBreakerEnergy
Accumulated energy for breaker in watt-hours. This object may not
exist on all platforms, due to hardware differences. |
watt-hoursUnsigned32 Constraints: range: 0-9999000 |
.1.3.6.1.4.1.21239.5.2.3.3.1.15 |
||||
|
pduBreakerResCurrentDetected
Tells if residual current was detected. In normal operation, the value
will be false(2). |
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.3.3.1.20 |
||||
|
pduBreakerLossOfLoadDetected
Tells if a loss of load was detected. In normal operation, the value
will be false(2). |
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.3.3.1.21 |
pduLineTable
table.1.3.6.1.4.1.21239.5.2.3.4
·
1 row entry
·
4 columns
PDU line current information
Entry in the pduLineTable table: each entry contains an index and
other sensor details
other sensor details
Indexes
pduLineIndex
| Column | Syntax | OID |
|---|---|---|
|
pduLineIndex
Table entry index value
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.3.4.1.1 |
|
pduLineName
PDU line name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.3.4.1.2 |
|
pduLineLabel
PDU line label (user-defined)
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.3.4.1.3 |
|
pduLineCurrent
PDU line current reading in hundredths of an amp
|
centiamps (rms)Unsigned32 Constraints: range: 0-9900 |
.1.3.6.1.4.1.21239.5.2.3.4.1.4 |
pduOutletSwitchTable
table.1.3.6.1.4.1.21239.5.2.3.5
·
1 row entry
·
13 columns
Data, config and control for outlets with switching
Entry in the pduOutletSwitchTable table: each entry contains an index
and other sensor details
and other sensor details
Indexes
pduOutletSwitchIndex
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pduOutletSwitchIndex
Table entry index value
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.3.5.1.1 |
||||||||||||||||
|
pduOutletSwitchName
PDU outlet name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.3.5.1.2 |
||||||||||||||||
|
pduOutletSwitchLabel
PDU outlet label (user-defined)
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.3.5.1.3 |
||||||||||||||||
|
pduOutletSwitchState
Switch state of the outlet:
1 = Outlet is on 2 = Outlet is off 3 = Outlet is on, but will turn off after a delay 4 = Outlet is off, but will turn on after a delay 5 = Starting reboot cycle, outlet is on, but will go to … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.3.5.1.4 |
||||||||||||||||
|
pduOutletSwitchRelayFailure
Tells if the outlet relay has failed. In normal operation, the value
will be false(2). |
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.3.5.1.5 |
||||||||||||||||
|
pduOutletSwitchControl
Used for manual control of the outlet. If the outlet is in manual
mode, this field can be set to one of the following values: 1 = Cancel pending operation 2 = Turn outlet on 3 = After delay (pduOutletSwitchOnDelay), tur… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.3.5.1.6 |
||||||||||||||||
|
pduOutletSwitchTimeToAction
Seconds until an outlet state change. The value of
pduOutletSwitchState tells what state the outlet will be set, after the delay. |
Integer32 Constraints: range: 0-600 |
.1.3.6.1.4.1.21239.5.2.3.5.1.7 |
||||||||||||||||
|
pduOutletSwitchOnDelay
Seconds to wait before powering on the outlet, during onAfterDelay(3)
operation. Changing this value has no effect on pending actions. |
Integer32r/w Constraints: range: 0-600 |
.1.3.6.1.4.1.21239.5.2.3.5.1.8 |
||||||||||||||||
|
pduOutletSwitchOffDelay
Seconds to wait before powering off the outlet, during
offAfterDelay(5) operation. Changing this value has no effect on pending actions. |
Integer32r/w Constraints: range: 0-600 |
.1.3.6.1.4.1.21239.5.2.3.5.1.9 |
||||||||||||||||
|
pduOutletSwitchRebootDelay
Seconds to wait before powering off the outlet, during
rebootAfterDelay(7) operation. Changing this value has no effect on pending actions. See pduOutletSwitchControl for more info. |
Integer32r/w Constraints: range: 0-600 |
.1.3.6.1.4.1.21239.5.2.3.5.1.10 |
||||||||||||||||
|
pduOutletSwitchRebootHoldDelay
Seconds to hold the outlet off, before powering on the outlet, during
rebootAfterDelay(7) operation. Changing this value has no effect on pending actions. See pduOutletSwitchControl for more info. |
Integer32r/w Constraints: range: 0-600 |
.1.3.6.1.4.1.21239.5.2.3.5.1.11 |
||||||||||||||||
|
pduOutletSwitchPoaAction
The outlet is set to this state during power-up. The action can be
have one the following values: 1 = Outlet will be turned on 2 = Outlet will stay off 3 = Outlet will be set to last known state |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.3.5.1.12 |
||||||||||||||||
|
pduOutletSwitchPoaDelay
Seconds to wait before setting the outlet to the
pduOutletSwitchPoaAction state. The delay starts at power-up. |
Integer32r/w Constraints: range: 0-600 |
.1.3.6.1.4.1.21239.5.2.3.5.1.13 |
pduOutletMeterTable
table.1.3.6.1.4.1.21239.5.2.3.6
·
1 row entry
·
11 columns
Metering data for outlets that support this feature
Entry in the pduOutletMeterTable table: each entry contains an index
and other sensor details
and other sensor details
Indexes
pduOutletMeterIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
pduOutletMeterIndex
Table entry index value
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.3.6.1.1 |
||||
|
pduOutletMeterName
PDU outlet name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.3.6.1.2 |
||||
|
pduOutletMeterLabel
PDU outlet label (user-defined)
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.3.6.1.3 |
||||
|
pduOutletMeterVoltage
PDU outlet voltage in tenths of a volt
|
decivolts (rms)Unsigned32 Constraints: range: 0-3100 |
.1.3.6.1.4.1.21239.5.2.3.6.1.4 |
||||
|
pduOutletMeterCurrent
PDU outlet current reading in hundredths of an amp
|
centiamps (rms)Unsigned32 Constraints: range: 0-9900 |
.1.3.6.1.4.1.21239.5.2.3.6.1.8 |
||||
|
pduOutletMeterRealPower
Real power for outlet in watts
|
wattsUnsigned32 Constraints: range: 0-9999 |
.1.3.6.1.4.1.21239.5.2.3.6.1.12 |
||||
|
pduOutletMeterApparentPower
Apparent power for outlet in volt-amps
|
volt-ampsUnsigned32 Constraints: range: 0-9999 |
.1.3.6.1.4.1.21239.5.2.3.6.1.13 |
||||
|
pduOutletMeterPowerFactor
Power factor for outlet
|
%Unsigned32 Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.3.6.1.14 |
||||
|
pduOutletMeterEnergy
Accumulated energy for outlet in watt-hours
|
watt-hoursUnsigned32 Constraints: range: 0-9999000 |
.1.3.6.1.4.1.21239.5.2.3.6.1.15 |
||||
|
pduOutletMeterReset
Used to reset energy. If read, the value is none(8). It can be set to
resetEnergy(1), which sets outlet energy to 0 |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.3.6.1.16 |
||||
|
pduOutletCurrentCrestFactor
Current crest factor for outlet, in hundredths
|
Unsigned32 Constraints: range: 0-9999 |
.1.3.6.1.4.1.21239.5.2.3.6.1.19 |
pduResidualCurrentTable
table.1.3.6.1.4.1.21239.5.2.3.7
·
1 row entry
·
5 columns
Residual current data for PDUs that support this feature
Entry in the pduResidualCurrentTable table: each entry contains an
index and other sensor details
index and other sensor details
Indexes
pduResidualCurrentIndex
| Column | Syntax | OID |
|---|---|---|
|
pduResidualCurrentIndex
Table entry index value
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.3.7.1.1 |
|
pduResidualCurrentName
PDU residual current name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.3.7.1.2 |
|
pduResidualCurrentLabel
PDU residual current label
|
OctetString Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.3.7.1.3 |
|
pduResidualCurrentAggregate
PDU residual current aggregate value in milliamps
|
milliampsUnsigned32 Constraints: range: 0-1000 |
.1.3.6.1.4.1.21239.5.2.3.7.1.4 |
|
pduResidualCurrentDc
PDU residual current DC value in milliamps
|
milliampsUnsigned32 Constraints: range: 0-1000 |
.1.3.6.1.4.1.21239.5.2.3.7.1.5 |
tempSensorTable
table.1.3.6.1.4.1.21239.5.2.4
·
1 row entry
·
5 columns
Remote Temperature (RT) sensor
Entry in the tempSensorTable table: each entry contains an index and
other sensor details
other sensor details
Indexes
tempSensorIndex
| Column | Syntax | OID |
|---|---|---|
|
tempSensorIndex
Table entry index value
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.4.1.1 |
|
tempSensorSerial
Serial number
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.21239.5.2.4.1.2 |
|
tempSensorLabel
User-defined label
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.4.1.3 |
|
tempSensorAvail
Device availability:
0 = Unavailable 1 = Available 2 = Partially Unavailable |
SNMPv2-SMIGauge32 Textual Convention: SNMPv2-SMIGauge32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.21239.5.2.4.1.4 |
|
tempSensorTemp
Temperature in tenths of a degree. Units are given by temperatureUnits
field in deviceInfo. |
decidegreesInteger32 Constraints: range: -400-2540 |
.1.3.6.1.4.1.21239.5.2.4.1.5 |
airFlowSensorTable
table.1.3.6.1.4.1.21239.5.2.5
·
1 row entry
·
8 columns
Remote Airflow, Humidity, Temperature and Dewpoint (AFHT3) Sensor
Entry in the airFlowSensorTable table: each entry contains an index
and other sensor details
and other sensor details
Indexes
airFlowSensorIndex
| Column | Syntax | OID |
|---|---|---|
|
airFlowSensorIndex
Table entry index value
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.5.1.1 |
|
airFlowSensorSerial
Serial number
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.21239.5.2.5.1.2 |
|
airFlowSensorLabel
User-defined label
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.5.1.3 |
|
airFlowSensorAvail
Device availability:
0 = Unavailable 1 = Available 2 = Partially Unavailable |
SNMPv2-SMIGauge32 Textual Convention: SNMPv2-SMIGauge32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.21239.5.2.5.1.4 |
|
airFlowSensorTemp
Temperature reading in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. |
decidegreesInteger32 Constraints: range: -400-2540 |
.1.3.6.1.4.1.21239.5.2.5.1.5 |
|
airFlowSensorFlow
Airflow reading. Still air will be less than 20, while rushing air
will be around 100. |
Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.5.1.6 |
|
airFlowSensorHumidity
Humidity reading
|
%Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.5.1.7 |
|
airFlowSensorDewPoint
Dewpoint reading in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. |
decidegreesInteger32 Constraints: range: -400-2540 |
.1.3.6.1.4.1.21239.5.2.5.1.8 |
t3hdSensorTable
table.1.3.6.1.4.1.21239.5.2.8
·
1 row entry
·
14 columns
Remote Temperature x 3, Humidity and Dewpoint Sensor
Entry in the t3hdSensorTable table: each entry contains an index and
other sensor details
other sensor details
Indexes
t3hdSensorIndex
| Column | Syntax | OID |
|---|---|---|
|
t3hdSensorIndex
Table entry index value
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.8.1.1 |
|
t3hdSensorSerial
Serial number
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.21239.5.2.8.1.2 |
|
t3hdSensorLabel
User-defined label
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.8.1.3 |
|
t3hdSensorAvail
Device availability:
0 = Unavailable 1 = Available 2 = Partially Unavailable |
SNMPv2-SMIGauge32 Textual Convention: SNMPv2-SMIGauge32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.21239.5.2.8.1.4 |
|
t3hdSensorIntLabel
Internal label (user-defined)
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.8.1.5 |
|
t3hdSensorIntTemp
Internal temperature in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. |
decidegreesInteger32 Constraints: range: -400-2540 |
.1.3.6.1.4.1.21239.5.2.8.1.6 |
|
t3hdSensorIntHumidity
Internal humidity
|
%Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.8.1.7 |
|
t3hdSensorIntDewPoint
Internal dewpoint in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. |
decidegreesInteger32 Constraints: range: -400-2540 |
.1.3.6.1.4.1.21239.5.2.8.1.8 |
|
t3hdSensorExtAAvail
External A status:
0 = Unavailable 1 = Available |
SNMPv2-SMIGauge32 Textual Convention: SNMPv2-SMIGauge32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.21239.5.2.8.1.9 |
|
t3hdSensorExtALabel
External A label (user-defined)
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.8.1.10 |
|
t3hdSensorExtATemp
External A temperature in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. |
decidegreesInteger32 Constraints: range: -400-2540 |
.1.3.6.1.4.1.21239.5.2.8.1.11 |
|
t3hdSensorExtBAvail
External B status:
0 = Unavailable 1 = Available |
SNMPv2-SMIGauge32 Textual Convention: SNMPv2-SMIGauge32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.21239.5.2.8.1.12 |
|
t3hdSensorExtBLabel
External B label (user-defined)
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.8.1.13 |
|
t3hdSensorExtBTemp
External B temperature in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. |
decidegreesInteger32 Constraints: range: -400-2540 |
.1.3.6.1.4.1.21239.5.2.8.1.14 |
thdSensorTable
table.1.3.6.1.4.1.21239.5.2.9
·
1 row entry
·
7 columns
Remote Temperature, Humidity, and Dewpoint (THD) Sensor
Entry in the thdSensorTable table: each entry contains an index and
other sensor details
other sensor details
Indexes
thdSensorIndex
| Column | Syntax | OID |
|---|---|---|
|
thdSensorIndex
Table entry index value
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.9.1.1 |
|
thdSensorSerial
Serial number
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.21239.5.2.9.1.2 |
|
thdSensorLabel
User-defined label
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.9.1.3 |
|
thdSensorAvail
Device availability:
0 = Unavailable 1 = Available 2 = Partially Unavailable |
SNMPv2-SMIGauge32 Textual Convention: SNMPv2-SMIGauge32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.21239.5.2.9.1.4 |
|
thdSensorTemp
Temperature value in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. |
decidegreesInteger32 Constraints: range: -400-2540 |
.1.3.6.1.4.1.21239.5.2.9.1.5 |
|
thdSensorHumidity
Humidity value
|
%Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.9.1.6 |
|
thdSensorDewPoint
Dewpoint value in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. |
decidegreesInteger32 Constraints: range: -400-2540 |
.1.3.6.1.4.1.21239.5.2.9.1.7 |
a2dSensorTable
table.1.3.6.1.4.1.21239.5.2.11
·
1 row entry
·
13 columns
Analog measurement (A2D) sensor (voltage, current, or dry-contact)
Entry in the a2dSensorTable table: each entry contains an index and
other sensor details
other sensor details
Indexes
a2dSensorIndex
| Column | Syntax | OID | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
a2dSensorIndex
Table entry index value
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.11.1.1 |
||||||||||||||||||||||
|
a2dSensorSerial
Serial number
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.21239.5.2.11.1.2 |
||||||||||||||||||||||
|
a2dSensorLabel
User-defined label
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.11.1.3 |
||||||||||||||||||||||
|
a2dSensorAvail
Device availability:
0 = Unavailable 1 = Available 2 = Partially Unavailable |
SNMPv2-SMIGauge32 Textual Convention: SNMPv2-SMIGauge32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.21239.5.2.11.1.4 |
||||||||||||||||||||||
|
a2dSensorValue
Analog measurement value, within either a user-defined or preset
range, depending on a2dSensorMode. |
Integer32 Constraints: range: -1000000-1000000 |
.1.3.6.1.4.1.21239.5.2.11.1.5 |
||||||||||||||||||||||
|
a2dSensorDisplayValue
For current/voltage modes, the analog value is given as a string. In
binary modes, the value is either a2dSensorLowLabel or a2dSensorHighLabel, based on a2dSensorValue. |
OctetString Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.11.1.6 |
||||||||||||||||||||||
|
a2dSensorMode
Binary modes have two states represented by the values 0 (low) or 1
(high). These correspond to a2dSensorLowLabel and a2dSensorHighLabel. Current and voltage modes provide a scaled value from a2dSensorMin to a2dSensorMa… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.11.1.7 |
||||||||||||||||||||||
|
a2dSensorUnits
The units for the analog value. If a2dSensorMode is customVoltage(9)
or customCurrent(11), then this field has a user-defined value. Otherwise, the value is fixed, based on mode. |
OctetStringr/w Constraints: range: 0-7 |
.1.3.6.1.4.1.21239.5.2.11.1.8 |
||||||||||||||||||||||
|
a2dSensorMin
Minimum analog value, given as an integer. The analog measurement is
scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is customVoltage(9) or customCurrent(11), then this field has a user- defined value… |
Integer32r/w Constraints: range: -1000000-1000000 |
.1.3.6.1.4.1.21239.5.2.11.1.9 |
||||||||||||||||||||||
|
a2dSensorMax
Maximum analog value, given as an integer. The analog measurement is
scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is customVoltage(9) or customCurrent(11), then this field has a user- defined value… |
Integer32r/w Constraints: range: -1000000-1000000 |
.1.3.6.1.4.1.21239.5.2.11.1.10 |
||||||||||||||||||||||
|
a2dSensorLowLabel
Label for 0 (low) binary value. This field is only applicable if
a2dSensorMode is one of the binary modes. If a2dSensorMode is customBinary(10), then this field is user-defined. Otherwise, it has a pre-defined value bas… |
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.11.1.11 |
||||||||||||||||||||||
|
a2dSensorHighLabel
Label for 1 (high) binary value. The field is only applicable if
a2dSensorMode is one of the binary modes. If a2dSensorMode is customBinary(10), then this field is user-defined. Otherwise, it has a pre-defined value bas… |
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.11.1.12 |
||||||||||||||||||||||
|
a2dSensorAnalogLabel
Label for the analog measurement
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.11.1.13 |
humiditySensorTable
table.1.3.6.1.4.1.21239.5.2.12
·
1 row entry
·
5 columns
Remote humidity sensor
Entry in the humiditySensorTable table: each entry contains an index
and other sensor details
and other sensor details
Indexes
humiditySensorIndex
| Column | Syntax | OID |
|---|---|---|
|
humiditySensorIndex
Table entry index value
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.12.1.1 |
|
humiditySensorSerial
Serial number
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.21239.5.2.12.1.2 |
|
humiditySensorLabel
User-defined label
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.12.1.3 |
|
humiditySensorAvail
Device availability:
0 = Unavailable 1 = Available 2 = Partially Unavailable |
SNMPv2-SMIGauge32 Textual Convention: SNMPv2-SMIGauge32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.21239.5.2.12.1.4 |
|
humiditySensorValue
Humidity value
|
Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.12.1.5 |
sn2dSensorTable
table.1.3.6.1.4.1.21239.5.2.13
·
1 row entry
·
10 columns
2 Door Switch Sensor (SN-2D)
Entry in the sn2dSensorTable table: each entry contains an index and
other sensor details
other sensor details
Indexes
sn2dSensorIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sn2dSensorIndex
Table entry index value
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.13.1.1 |
||||
|
sn2dSensorSerial
Serial number
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.21239.5.2.13.1.2 |
||||
|
sn2dSensorLabel
User-defined label
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.13.1.3 |
||||
|
sn2dSensorAvail
Device availability:
0 = Unavailable 1 = Available 2 = Partially Unavailable |
SNMPv2-SMIGauge32 Textual Convention: SNMPv2-SMIGauge32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.21239.5.2.13.1.4 |
||||
|
sn2dSensorDoor1Label
Door switch 1 label
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.13.1.5 |
||||
|
sn2dSensorDoor1State
Door switch 1 state:
1 = open 2 = closed |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.13.1.6 |
||||
|
sn2dSensorDoor1DisplayState
Door switch 1 state given as a string
|
OctetString Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.13.1.7 |
||||
|
sn2dSensorDoor2Label
Door switch 2 label
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.13.1.8 |
||||
|
sn2dSensorDoor2State
Door switch 2 state:
1 = open 2 = closed |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.13.1.9 |
||||
|
sn2dSensorDoor2DisplayState
Door switch 2 state given as a string
|
OctetString Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.13.1.10 |
vrcMainTable
table.1.3.6.1.4.1.21239.5.2.30.1.1
·
1 row entry
·
5 columns
Table that contains general VRC information
Entry in the vrcMainTable: each entry represents a VRC device
Indexes
vrcMainIndex
| Column | Syntax | OID |
|---|---|---|
|
vrcMainIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.1.1.1 |
|
vrcMainSerial
Serial number
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.21239.5.2.30.1.1.1.2 |
|
vrcMainName
VRC name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.30.1.1.1.3 |
|
vrcMainLabel
VRC label (user-defined)
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.21239.5.2.30.1.1.1.4 |
|
vrcMainAvail
Device availability:
0 = Unavailable 1 = Available 2 = Partially Unavailable |
SNMPv2-SMIGauge32 Textual Convention: SNMPv2-SMIGauge32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.21239.5.2.30.1.1.1.5 |
vrcMainPtTable
table.1.3.6.1.4.1.21239.5.2.30.1.2
·
1 row entry
·
29 columns
Table that contains general VRC status
Entry in the vrcMainPtTable: each entry contains status data for a VRC
device
device
Indexes
vrcMainPtIndex
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
vrcMainPtIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.2.1.1 |
||||||||||||
|
vrcMainPtRunState
VRC run state:
1 = on 2 = off |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.2 |
||||||||||||
|
vrcMainPtEevOpened
Eev opened value (percent)
|
%Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.2.1.3 |
||||||||||||
|
vrcMainPtAlarmNumbers
Alarm numbers value
|
Integer32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.21239.5.2.30.1.2.1.4 |
||||||||||||
|
vrcMainPtHistoryAlarmNumbers
History alarm numbers value
|
Integer32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.21239.5.2.30.1.2.1.5 |
||||||||||||
|
vrcMainPtHpAbnRecordCnt
Hp Abnormal record count
|
Integer32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.21239.5.2.30.1.2.1.6 |
||||||||||||
|
vrcMainPtMonitorBaudrate
Monitor baud rate:
1 = error 2 = 1200 3 = 2400 4 = 4800 5 = 9600 6 = 19200 |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.7 |
||||||||||||
|
vrcMainPtMonitorAddress
Monitor address
|
Integer32 Constraints: range: 1-247 |
.1.3.6.1.4.1.21239.5.2.30.1.2.1.8 |
||||||||||||
|
vrcMainPtLp
Lp status
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.9 |
||||||||||||
|
vrcMainPtFilterMaintRemind
Filter maintenance reminder status
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.10 |
||||||||||||
|
vrcMainPtCoolingFlag
Cooling flag
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.11 |
||||||||||||
|
vrcMainPtFirstOnFlag
First on flag
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.12 |
||||||||||||
|
vrcMainPtNewAlarmFlag
New alarm flag
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.13 |
||||||||||||
|
vrcMainPtComAlarmOutState
Common alarm output state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.14 |
||||||||||||
|
vrcMainPtHighWaterInput
High water input
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.15 |
||||||||||||
|
vrcMainPtHighWaterAlarm
High water alarm status
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.16 |
||||||||||||
|
vrcMainPtWaterUnderFloorAlarm
Water under floor alarm status
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.17 |
||||||||||||
|
vrcMainPtSwShutDownStatus
Software shutdown status
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.18 |
||||||||||||
|
vrcMainPtRemoteShutdown
Remote shutdown status
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.19 |
||||||||||||
|
vrcMainPtRemoteShutDownFlag
Remote shutdown flag
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.20 |
||||||||||||
|
vrcMainPtRemoteShutDownAlarm
Remote shutdown alarm status
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.21 |
||||||||||||
|
vrcMainPtHmiShutDownFlag
Hmi shutdown flag
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.22 |
||||||||||||
|
vrcMainPtLpAlarm
Low pressure alarm status
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.23 |
||||||||||||
|
vrcMainPtHpAlarm
High pressure alarm status
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.24 |
||||||||||||
|
vrcMainPtLpFreqAlarm
Low pressure frequently alarm status
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.25 |
||||||||||||
|
vrcMainPtHpFreqAlarm
High pressure frequently alarm status
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.26 |
||||||||||||
|
vrcMainPtLpSensorFailAlarm
Low pressure sensor failure alarm status
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.27 |
||||||||||||
|
vrcMainPtHpSensorFailAlarm
High pressure sensor failure alarm status
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.28 |
||||||||||||
|
vrcMainPtEevCommFailAlarm
Eev communication failure alarm status
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.2.1.29 |
vrcMainCfgTable
table.1.3.6.1.4.1.21239.5.2.30.1.3
·
1 row entry
·
35 columns
Table that contains general VRC configuration
Entry in the vrcMainCfgTable: each entry contains general config
fields for a VRC device
fields for a VRC device
Indexes
vrcMainCfgIndex
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
vrcMainCfgIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.1 |
||||||||||||||
|
vrcMainCfgModelSelect
Model Selection:
1 = TMM-Local 220V 50/60HZ 2 = TMM-Global 208/230V 50/60HZ 3 = TMM-Global 120V 50/60HZ 4 = SC 220V 50/60HZ 5 = 0U 220V 50/60HZ 6 = SS 208/230V 50/60HZ 7 = SS 120V 50/60HZ |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.2 |
||||||||||||||
|
vrcMainCfgSystemTimeYear
System time - year
|
Integer32r/w Constraints: range: 2000-2099 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.3 |
||||||||||||||
|
vrcMainCfgSystemTimeMonth
System time - month
|
Integer32r/w Constraints: range: 1-12 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.4 |
||||||||||||||
|
vrcMainCfgSystemTimeDay
System time - day
|
Integer32r/w Constraints: range: 1-31 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.5 |
||||||||||||||
|
vrcMainCfgSystemTimeHour
System time - hour
|
Integer32r/w Constraints: range: 0-23 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.6 |
||||||||||||||
|
vrcMainCfgSystemTimeMin
System time - minutes
|
Integer32r/w Constraints: range: 0-59 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.7 |
||||||||||||||
|
vrcMainCfgSystemTimeSec
System time - seconds
|
Integer32r/w Constraints: range: 0-59 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.8 |
||||||||||||||
|
vrcMainCfgEevShtSettingMin
Min Eev sht in tenths of a degree. Units are given by temperatureUnits
field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 50 to 200 Fahrenheit: 90 to 359 |
decidegreesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.9 |
||||||||||||||
|
vrcMainCfgEevShtSettingMax
Max Eev sht in tenths of a degree. Units are given by temperatureUnits
field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 50 to 200 Fahrenheit: 90 to 359 |
decidegreesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.10 |
||||||||||||||
|
vrcMainCfgEevValveCloseSht
Eev valve close sht in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 0 to 100 Fahrenheit: 0 to 179 |
decidegreesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.11 |
||||||||||||||
|
vrcMainCfgEevMopPressSetting
Eev mop pressure setting in tenths of a bar.
|
decibarsInteger32r/w Constraints: range: 0-200 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.12 |
||||||||||||||
|
vrcMainCfgLpdt
Low pressure dt in seconds
|
secondsInteger32r/w Constraints: range: 30-600 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.13 |
||||||||||||||
|
vrcMainCfgDeadBand
Dead band in tenths of a degree. Units are given by temperatureUnits
field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 0 to 20 Fahrenheit: 0 to 35 |
decidegreesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.14 |
||||||||||||||
|
vrcMainCfgOnOffSwitch
On-off switch
|
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.15 |
||||||||||||||
|
vrcMainCfgVacuumState
Vacuum state
|
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.16 |
||||||||||||||
|
vrcMainCfgControlMode
Control mode:
1 = supply 2 = return |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.17 |
||||||||||||||
|
vrcMainCfgManualRunEnable
Manual run enable
|
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.18 |
||||||||||||||
|
vrcMainCfgRemShutdownInput
Remote shutdown input
|
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.19 |
||||||||||||||
|
vrcMainCfgMonitorShutDownFlag
Monitor shutdown flag
|
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.20 |
||||||||||||||
|
vrcMainCfgFirstOnPassword
First on password value
|
Integer32r/w Constraints: range: -32768-32767 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.21 |
||||||||||||||
|
vrcMainCfgFilterMaintSetting
Filter maintenance setting
|
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.22 |
||||||||||||||
|
vrcMainCfgFilterMaintRemindTime
Time between filter maintenance reminders in days
|
daysInteger32r/w Constraints: range: 30-360 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.23 |
||||||||||||||
|
vrcMainCfgFilterMaintRemindCtrl
Filter maintenance reminder:
1 = close 2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.24 |
||||||||||||||
|
vrcMainCfgCommonAlarmOutputDir
Common alarm output direction
|
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.25 |
||||||||||||||
|
vrcMainCfgHpAbnAlarmSetting
Abnormal high pressure alarm value in tenths of a bar
|
decibarsInteger32r/w Constraints: range: 300-360 |
.1.3.6.1.4.1.21239.5.2.30.1.3.1.26 |
||||||||||||||
|
vrcMainCfgLpAlarmCtrl
Low pressure alarm control:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.27 |
||||||||||||||
|
vrcMainCfgHpAlarmCtrl
High pressure alarm control:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.28 |
||||||||||||||
|
vrcMainCfgLpFreqAlarmCtrl
Low pressure frequently alarm control:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.29 |
||||||||||||||
|
vrcMainCfgHpFreqAlarmCtrl
High pressure frequently alarm control:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.30 |
||||||||||||||
|
vrcMainCfgLpSensorFailAlarmCtrl
Low pressure sensor failure alarm control:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.31 |
||||||||||||||
|
vrcMainCfgHpSensorFailAlarmCtrl
High pressure sensor failure alarm control:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.32 |
||||||||||||||
|
vrcMainCfgHighWaterAlarmCtrl
High water alarm control:
1 = close 2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.33 |
||||||||||||||
|
vrcMainCfgRemShutdownAlarmCtrl
Remote shutdown alarm control:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.34 |
||||||||||||||
|
vrcMainCfgEevCommFailAlarmCtrl
Eev communication failure alarm:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.3.1.35 |
vrcOutFanPtTable
table.1.3.6.1.4.1.21239.5.2.30.1.4
·
1 row entry
·
3 columns
Table that contains VRC out-fan status
Entry in the vrcOutFanPtTable: each entry represents data for a VRC
out-fan
out-fan
Indexes
vrcOutFanPtIndex
| Column | Syntax | OID |
|---|---|---|
|
vrcOutFanPtIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.4.1.1 |
|
vrcOutFanPtName
Out-fan name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.30.1.4.1.2 |
|
vrcOutFanPtSpeed
Fan speed (percent)
|
%Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.4.1.3 |
vrcOutFanCfgTable
table.1.3.6.1.4.1.21239.5.2.30.1.5
·
1 row entry
·
6 columns
Table used for VRC out-fan configuration
Entry in the vrcOutFanCfgTable: each entry contains config fields for
a VRC out-fan
a VRC out-fan
Indexes
vrcOutFanCfgIndex
| Column | Syntax | OID |
|---|---|---|
|
vrcOutFanCfgIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.5.1.1 |
|
vrcOutFanCfgStartPress
Out-fan start pressure in tenths of a bar
|
decibarsInteger32r/w Constraints: range: 190-250 |
.1.3.6.1.4.1.21239.5.2.30.1.5.1.2 |
|
vrcOutFanCfgPressSetting
Out-fan pressure setting in tenths of a bar
|
decibarsInteger32r/w Constraints: range: 50-80 |
.1.3.6.1.4.1.21239.5.2.30.1.5.1.3 |
|
vrcOutFanCfgMinPowerVoltage
Min out-fan voltage (percent)
|
%Integer32r/w Constraints: range: 30-50 |
.1.3.6.1.4.1.21239.5.2.30.1.5.1.4 |
|
vrcOutFanCfgMaxPowerVoltage
Max out-fan voltage (percent)
|
%Integer32r/w Constraints: range: 60-100 |
.1.3.6.1.4.1.21239.5.2.30.1.5.1.5 |
|
vrcOutFanCfgSpeed
Out-fan speed (percent)
|
%Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.5.1.6 |
vrcInFanPtTable
table.1.3.6.1.4.1.21239.5.2.30.1.6
·
1 row entry
·
4 columns
Table that contains VRC in-fan status
Entry in the vrcInFanPtTable: each entry represents data for a VRC in-
fan
fan
Indexes
vrcInFanPtIndex
| Column | Syntax | OID |
|---|---|---|
|
vrcInFanPtIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.6.1.1 |
|
vrcInFanPtName
In-fan name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.30.1.6.1.2 |
|
vrcInFanPtRunTimeHours
In-fan run time in hours
|
hoursInteger32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.21239.5.2.30.1.6.1.3 |
|
vrcInFanPtStartStopCount
In-fan start/stop count
|
Integer32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.21239.5.2.30.1.6.1.4 |
vrcInFanCfgTable
table.1.3.6.1.4.1.21239.5.2.30.1.7
·
1 row entry
·
24 columns
Table used for VRC in-fan configuration
Entry in the vrcInFanCfgTable: each entry contains config fields for a
VRC in-fan
VRC in-fan
Indexes
vrcInFanCfgIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
vrcInFanCfgIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.1 |
||||
|
vrcInFanCfgOutputStatus
In-fan output status
|
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.7.1.2 |
||||
|
vrcInFanCfgLowSpeedStep
In-fan low speed step in tenths of a percent per second
|
0.1%/sInteger32r/w Constraints: range: 1-20 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.3 |
||||
|
vrcInFanCfgHighSpeedStep
In-fan high speed step in tenths of a percent per second
|
0.1%/sInteger32r/w Constraints: range: 1-50 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.4 |
||||
|
vrcInFanCfgMinSpeed
Min in-fan speed (percent)
|
%Integer32r/w Constraints: range: 30-80 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.5 |
||||
|
vrcInFanCfgStandardSpeed
Standard in-fan speed (percent)
|
%Integer32r/w Constraints: range: 80-100 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.6 |
||||
|
vrcInFanCfgMinCfc
Min in-fan cfc (percent)
|
%Integer32r/w Constraints: range: 0-30 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.7 |
||||
|
vrcInFanCfgStandardCfc
Standard in-fan cfc (percent)
|
%Integer32r/w Constraints: range: 85-100 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.8 |
||||
|
vrcInFanCfgStartDelay
In-fan start delay in seconds
|
secondsInteger32r/w Constraints: range: 10-600 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.9 |
||||
|
vrcInFanCfgStopDelay
In-fan stop delay in seconds
|
secondsInteger32r/w Constraints: range: 10-300 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.10 |
||||
|
vrcInFanCfgReduceSpeedDelay
In-fan reduce speed delay in seconds
|
secondsInteger32r/w Constraints: range: 0-300 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.11 |
||||
|
vrcInFanCfgJumpBand1
In-fan jump band 1 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.12 |
||||
|
vrcInFanCfgJumpBand2
In-fan jump band 2 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.13 |
||||
|
vrcInFanCfgJumpBand3
In-fan jump band 3 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.14 |
||||
|
vrcInFanCfgJumpBand4
In-fan jump band 4 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.15 |
||||
|
vrcInFanCfgJumpBand5
In-fan jump band 5 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.16 |
||||
|
vrcInFanCfgJumpFreq1
In-fan jump frequency 1 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.17 |
||||
|
vrcInFanCfgJumpFreq2
In-fan jump frequency 2 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.18 |
||||
|
vrcInFanCfgJumpFreq3
In-fan jump frequency 3 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.19 |
||||
|
vrcInFanCfgJumpFreq4
In-fan jump frequency 4 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.20 |
||||
|
vrcInFanCfgJumpFreq5
In-fan jump frequency 5 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.21 |
||||
|
vrcInFanCfgTempP
In-fan temperature P in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. |
decidegreesInteger32r/w Constraints: range: 10-150 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.22 |
||||
|
vrcInFanCfgTempI
In-fan temperature I in seconds
|
secondsInteger32r/w Constraints: range: 0-900 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.23 |
||||
|
vrcInFanCfgTempD
In-fan temperature D in seconds
|
secondsInteger32r/w Constraints: range: 0-900 |
.1.3.6.1.4.1.21239.5.2.30.1.7.1.24 |
vrcCompPtTable
table.1.3.6.1.4.1.21239.5.2.30.1.8
·
1 row entry
·
23 columns
Table that contains VRC compressor status
Entry in the vrcCompPtTable: each entry represents data for a VRC
compressor
compressor
Indexes
vrcCompPtIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
vrcCompPtIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.8.1.1 |
||||
|
vrcCompPtName
Compressor name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.30.1.8.1.2 |
||||
|
vrcCompPtCapacity
Compressor capacity value (percent)
|
%Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.8.1.3 |
||||
|
vrcCompPtRunTimeHours
Compressor run time in hours
|
hoursInteger32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.21239.5.2.30.1.8.1.4 |
||||
|
vrcCompPtStartStopCount
Compressor start/stop count
|
Integer32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.21239.5.2.30.1.8.1.5 |
||||
|
vrcCompPtDriverFaultU00
Compressor driver fault alarm U00 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.6 |
||||
|
vrcCompPtDriverFaultU01
Compressor driver fault alarm U01 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.7 |
||||
|
vrcCompPtDriverFaultU02
Compressor driver fault alarm U02 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.8 |
||||
|
vrcCompPtDriverFaultU03
Compressor driver fault alarm U03 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.9 |
||||
|
vrcCompPtDriverFaultU04
Compressor driver fault alarm U04 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.10 |
||||
|
vrcCompPtDriverFaultU05
Compressor driver fault alarm U05 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.11 |
||||
|
vrcCompPtDriverFaultU06
Compressor driver fault alarm U06 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.12 |
||||
|
vrcCompPtDriverFaultU07
Compressor driver fault alarm U07 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.13 |
||||
|
vrcCompPtDriverFaultU08
Compressor driver fault alarm U08 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.14 |
||||
|
vrcCompPtDriverFaultU09
Compressor driver fault alarm U09 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.15 |
||||
|
vrcCompPtDriverFaultU10
Compressor driver fault alarm U10 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.16 |
||||
|
vrcCompPtDriverFaultU11
Compressor driver fault alarm U11 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.17 |
||||
|
vrcCompPtDriverFaultU12
Compressor driver fault alarm U12 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.18 |
||||
|
vrcCompPtDriverFaultU13
Compressor driver fault alarm U13 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.19 |
||||
|
vrcCompPtDriverFaultU14
Compressor driver fault alarm U14 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.20 |
||||
|
vrcCompPtDriverFaultU15
Compressor driver fault alarm U15 state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.21 |
||||
|
vrcCompPtDriverCommFailAlarm
Compressor driver communication failure alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.22 |
||||
|
vrcCompPtFaultLockAlarm
Compressor fault lock alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.8.1.23 |
vrcCompCfgTable
table.1.3.6.1.4.1.21239.5.2.30.1.9
·
1 row entry
·
27 columns
Table used for VRC compressor configuration
Entry in the vrcCompCfgTable: each entry contains config fields for a
VRC compressor
VRC compressor
Indexes
vrcCompCfgIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
vrcCompCfgIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.1 |
||||
|
vrcCompCfgOutputStatus
Compressor output status
|
SNMPv2-TCTruthValuer/w Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.9.1.2 |
||||
|
vrcCompCfgOutputDeadBand
Compressor output dead band in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-50 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.3 |
||||
|
vrcCompCfgCapacityOutputValue
Compressor capacity output (percent)
|
%Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.4 |
||||
|
vrcCompCfgMinCapacity
Compressor min capacity (percent)
|
%Integer32r/w Constraints: range: 15-50 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.5 |
||||
|
vrcCompCfgStartCapacity
Compressor start capacity (percent)
|
%Integer32r/w Constraints: range: 40-100 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.6 |
||||
|
vrcCompCfgStandardCapacity
Compressor standard capacity (percent)
|
%Integer32r/w Constraints: range: 80-100 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.7 |
||||
|
vrcCompCfgStartCfc
Compressor start cfc (percent)
|
%Integer32r/w Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.8 |
||||
|
vrcCompCfgStopCfc
Compressor stop cfc (percent)
|
%Integer32r/w Constraints: range: -200--50 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.9 |
||||
|
vrcCompCfgMinRunTime
Compressor min run time in minutes
|
minutesInteger32r/w Constraints: range: 0-30 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.10 |
||||
|
vrcCompCfgMinStopTime
Compressor min stop time in minutes
|
minutesInteger32r/w Constraints: range: 0-10 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.11 |
||||
|
vrcCompCfgJumpBand1
Compressor jump band 1 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.12 |
||||
|
vrcCompCfgJumpBand2
Compressor jump band 2 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.13 |
||||
|
vrcCompCfgJumpBand3
Compressor jump band 3 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.14 |
||||
|
vrcCompCfgJumpBand4
Compressor jump band 4 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.15 |
||||
|
vrcCompCfgJumpBand5
Compressor jump band 5 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.16 |
||||
|
vrcCompCfgJumpFreq1
Compressor jump frequency 1 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.17 |
||||
|
vrcCompCfgJumpFreq2
Compressor jump frequency 2 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.18 |
||||
|
vrcCompCfgJumpFreq3
Compressor jump frequency 3 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.19 |
||||
|
vrcCompCfgJumpFreq4
Compressor jump frequency 4 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.20 |
||||
|
vrcCompCfgJumpFreq5
Compressor jump frequency 5 in tenths of a percent
|
0.1%Integer32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.21 |
||||
|
vrcCompCfgTempP
Compressor temperature P in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 10 to 150 Fahrenheit: 18 to 269 |
decidegreesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.22 |
||||
|
vrcCompCfgTempI
Compressor temperature I in seconds
|
secondsInteger32r/w Constraints: range: 0-900 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.23 |
||||
|
vrcCompCfgTempD
Compressor temperature D in seconds
|
secondsInteger32r/w Constraints: range: 0-900 |
.1.3.6.1.4.1.21239.5.2.30.1.9.1.24 |
||||
|
vrcCompCfgDriverFaultAlmCtrl
Compressor driver fault alarm control:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.9.1.25 |
||||
|
vrcCompCfgDriverCommFailAlmCtrl
Compressor driver communication failure alarm control:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.9.1.26 |
||||
|
vrcCompCfgFaultLockAlmCtrl
Compressor fault lock alarm control:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.9.1.27 |
vrcReturnPtTable
table.1.3.6.1.4.1.21239.5.2.30.1.10
·
1 row entry
·
5 columns
Table that contains VRC return status
Entry in the vrcReturnPtTable: each entry represents return data for a
VRC
VRC
Indexes
vrcReturnPtIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
vrcReturnPtIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.10.1.1 |
||||
|
vrcReturnPtName
Return name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.30.1.10.1.2 |
||||
|
vrcReturnPtTemp
Return temperature value in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. The range is determined by the current temperature units. Celsius: -400 to 1000 Fahrenheit: -400 to 2120 |
decidegreesSNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.10.1.3 |
||||
|
vrcReturnPtHighTempAlarm
Return high temperature alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.10.1.4 |
||||
|
vrcReturnPtTempSensorFailAlarm
Return temperature sensor failure alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.10.1.5 |
vrcReturnCfgTable
table.1.3.6.1.4.1.21239.5.2.30.1.11
·
1 row entry
·
9 columns
Table used for VRC return configuration
Entry in the vrcReturnCfgTable: each entry contains config fields for
VRC return
VRC return
Indexes
vrcReturnCfgIndex
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
vrcReturnCfgIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.11.1.1 |
||||||
|
vrcReturnCfgOilCycle
Return oil cycle in tenths of an hour
|
decihoursInteger32r/w Constraints: range: 5-50 |
.1.3.6.1.4.1.21239.5.2.30.1.11.1.2 |
||||||
|
vrcReturnCfgOilRunCapacity
Return Oil run capacity (percent)
|
%Integer32r/w Constraints: range: 50-100 |
.1.3.6.1.4.1.21239.5.2.30.1.11.1.3 |
||||||
|
vrcReturnCfgOilRunTime
Return oil run time in minutes
|
minutesInteger32r/w Constraints: range: 0-10 |
.1.3.6.1.4.1.21239.5.2.30.1.11.1.4 |
||||||
|
vrcReturnCfgTempCalValue
Return temperature calibration value in tenths of a degree. Units are
given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: -100 to 100 Fahrenheit:… |
decidegreesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.11.1.5 |
||||||
|
vrcReturnCfgTempSetting
Return temperature setting in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 250 to 350 Fahrenheit: 770 to 949 |
decidegreesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.11.1.6 |
||||||
|
vrcReturnCfgHighTempAlarmValue
Return high temperature alarm value in tenths of a degree. Units are
given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 300 to 450 Fahrenheit: 8… |
decidegreesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.11.1.7 |
||||||
|
vrcReturnCfgHighTempAlarmCtrl
Return high temperature alarm control:
1 = close 2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.11.1.8 |
||||||
|
vrcReturnCfgTempSensFailAlmCtrl
Return temperature sensor failure alarm control:
1 = close 2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.11.1.9 |
vrcSupplyPtTable
table.1.3.6.1.4.1.21239.5.2.30.1.12
·
1 row entry
·
6 columns
Table that contains VRC supply status
Entry in the vrcSupplyPtTable: each entry represents supply data for a
VRC
VRC
Indexes
vrcSupplyPtIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
vrcSupplyPtIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.12.1.1 |
||||
|
vrcSupplyPtName
Supply name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.30.1.12.1.2 |
||||
|
vrcSupplyPtTemp
Supply temperature value in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. The range is determined by the current temperature units. Celsius: -400 to 1000 Fahrenheit: -400 to 2120 |
decidegreesSNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.12.1.3 |
||||
|
vrcSupplyPtLowTempAlarm
Supply low temperature alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.12.1.4 |
||||
|
vrcSupplyPtHighTempAlarm
Supply high temperature alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.12.1.5 |
||||
|
vrcSupplyPtTempSensorFailAlarm
Supply temperature sensor failure alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.12.1.6 |
vrcSupplyCfgTable
table.1.3.6.1.4.1.21239.5.2.30.1.13
·
1 row entry
·
8 columns
Table used for VRC supply configuration
Entry in the vrcSupplyCfgTable: each entry contains config fields for
a VRC supply
a VRC supply
Indexes
vrcSupplyCfgIndex
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
vrcSupplyCfgIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.13.1.1 |
||||||
|
vrcSupplyCfgTempCalValue
Supply temperature calibration value in tenths of a degree. Units are
given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: -100 to 100 Fahrenheit:… |
decidegreesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.13.1.2 |
||||||
|
vrcSupplyCfgTempSetting
Supply temperature setting in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 130 to 280 Fahrenheit: 554 to 823 |
decidegreesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.13.1.3 |
||||||
|
vrcSupplyCfgLowTempAlarmValue
Supply low temperature alarm value in tenths of a degree. Units are
given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 50 to 200 Fahrenheit: 410… |
decidegreesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.13.1.4 |
||||||
|
vrcSupplyCfgHighTempAlarmValue
Supply high temperature alarm value in tenths of a degree. Units are
given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: 200 to 350 Fahrenheit: 6… |
decidegreesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.13.1.5 |
||||||
|
vrcSupplyCfgLowTempAlmCtrl
Supply low temperature alarm control:
1 = close 2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.13.1.6 |
||||||
|
vrcSupplyCfgHighTempAlmCtrl
Supply high temperature alarm control:
1 = close 2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.13.1.7 |
||||||
|
vrcSupplyCfgTempSensFailAlmCtrl
Supply temperature sensor failure alarm control:
1 = close 2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.13.1.8 |
vrcPowerPtTable
table.1.3.6.1.4.1.21239.5.2.30.1.14
·
1 row entry
·
9 columns
Table that contains VRC power status
Entry in the vrcPowerPtTable: each entry represents power data for a
VRC
VRC
Indexes
vrcPowerPtIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
vrcPowerPtIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.14.1.1 |
||||
|
vrcPowerPtName
Power name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.30.1.14.1.2 |
||||
|
vrcPowerPtVoltage
Power voltage measurement in tenths of a volt
|
decivoltsInteger32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.21239.5.2.30.1.14.1.3 |
||||
|
vrcPowerPtFrequency
Power frequency measurement in tenths of hertz
|
decihertzInteger32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.21239.5.2.30.1.14.1.4 |
||||
|
vrcPowerPtLowVoltageAlarm
Power low voltage alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.14.1.5 |
||||
|
vrcPowerPtHighVoltageAlarm
Power high voltage alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.14.1.6 |
||||
|
vrcPowerPtLossOfPhasePowerAlarm
Phase power loss alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.14.1.7 |
||||
|
vrcPowerPtLossOfPowerAlarm
Power loss alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.14.1.8 |
||||
|
vrcPowerPtFrequencyErrorAlarm
Power frequency error alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.14.1.9 |
vrcPowerCfgTable
table.1.3.6.1.4.1.21239.5.2.30.1.15
·
1 row entry
·
7 columns
Table used for VRC power configuration
Entry in the vrcPowerCfgTable: each entry contains config fields for
VRC power
VRC power
Indexes
vrcPowerCfgIndex
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
vrcPowerCfgIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.15.1.1 |
||||||
|
vrcPowerCfgLowVoltageSetting
Power low voltage setting in volts
|
voltsInteger32r/w Constraints: range: 100-230 |
.1.3.6.1.4.1.21239.5.2.30.1.15.1.2 |
||||||
|
vrcPowerCfgHighVoltageSetting
Power high voltage setting in volts
|
voltsInteger32r/w Constraints: range: 100-300 |
.1.3.6.1.4.1.21239.5.2.30.1.15.1.3 |
||||||
|
vrcPowerCfgLowVoltageAlarmCtrl
Power low voltage alarm control:
1 = close 2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.15.1.4 |
||||||
|
vrcPowerCfgHighVoltageAlarmCtrl
Power high voltage alarm control:
1 = close 2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.15.1.5 |
||||||
|
vrcPowerCfgLossOfPowerAlarmCtrl
Power loss alarm control:
1 = close 2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.15.1.6 |
||||||
|
vrcPowerCfgFreqErrorAlarmCtrl
Power frequency error alarm control:
1 = close 2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.15.1.7 |
vrcOutdoorPtTable
table.1.3.6.1.4.1.21239.5.2.30.1.16
·
1 row entry
·
3 columns
Table that contains VRC outdoor status
Entry in the vrcOutdoorPtTable: each entry represents data for a VRC
outdoor
outdoor
Indexes
vrcOutdoorPtIndex
| Column | Syntax | OID |
|---|---|---|
|
vrcOutdoorPtIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.16.1.1 |
|
vrcOutdoorPtName
Outdoor name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.30.1.16.1.2 |
|
vrcOutdoorPtTemp
Outdoor temperature value in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. The range is determined by the current temperature units. Celsius: -400 to 1000 Fahrenheit: -400 to 2120 |
decidegreesSNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.16.1.3 |
vrcDischPtTable
table.1.3.6.1.4.1.21239.5.2.30.1.18
·
1 row entry
·
7 columns
Table that contains VRC discharge status
Entry in the vrcDischPtTable: each entry represents discharge data for
a VRC
a VRC
Indexes
vrcDischPtIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
vrcDischPtIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.18.1.1 |
||||
|
vrcDischPtName
Discharge name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.30.1.18.1.2 |
||||
|
vrcDischPtTemp
Discharge temperature value in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. The range is determined by the current temperature units. Celsius: -400 to 1560 Fahrenheit: -400 to 3128 |
decidegreesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.18.1.3 |
||||
|
vrcDischPtPressure
Discharge air pressure value in tenths of a bar
|
decibarsInteger32r/w Constraints: range: 0-460 |
.1.3.6.1.4.1.21239.5.2.30.1.18.1.4 |
||||
|
vrcDischPtHighTempAlarm
Discharge high temperature alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.18.1.5 |
||||
|
vrcDischPtHighTempFreqAlarm
Discharge high temperature frequently alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.18.1.6 |
||||
|
vrcDischPtTempSensorFailAlarm
Discharge temperature sensor failure alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.18.1.7 |
vrcDischCfgTable
table.1.3.6.1.4.1.21239.5.2.30.1.19
·
1 row entry
·
6 columns
Table used for VRC discharge configuration
Entry in the vrcDischCfgTable: each entry contains config fields for
VRC discharge
VRC discharge
Indexes
vrcDischCfgIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
vrcDischCfgIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.19.1.1 |
||||
|
vrcDischCfgTempCalValue
Discharge temperature calibration value in tenths of a degree. Units
are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Celsius: -100 to 100 Fahrenhe… |
decidegreesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.19.1.2 |
||||
|
vrcDischCfgPressCalValue
Discharge pressure calibration value in tenths of a bar
|
decibarsInteger32r/w Constraints: range: -100-100 |
.1.3.6.1.4.1.21239.5.2.30.1.19.1.3 |
||||
|
vrcDischCfgHighTempAlmCtrl
Discharge high temperature alarm control:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.19.1.4 |
||||
|
vrcDischCfgHighTempFreqAlmCtrl
Discharge high temperature frequenctly alarm control:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.19.1.5 |
||||
|
vrcDischCfgTempSensFailAlmCtrl
Discharge temperature sensor failure alarm control:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.19.1.6 |
vrcSuctPtTable
table.1.3.6.1.4.1.21239.5.2.30.1.20
·
1 row entry
·
6 columns
Table that contains VRC suction status
Entry in the vrcSuctPtTable: each entry represents suction data for a
VRC
VRC
Indexes
vrcSuctPtIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
vrcSuctPtIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.20.1.1 |
||||
|
vrcSuctPtName
Suction name (factory-assigned)
|
OctetString Constraints: range: 1-25 |
.1.3.6.1.4.1.21239.5.2.30.1.20.1.2 |
||||
|
vrcSuctPtTemp
Suction temperature in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. The range is determined by the current temperature units. Celsius: -400 to 1000 Fahrenheit: -400 to 2120 |
decidegreesSNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.20.1.3 |
||||
|
vrcSuctPtPressure
Suction air pressure in tenths of a bar
|
decibarsInteger32 Constraints: range: 0-173 |
.1.3.6.1.4.1.21239.5.2.30.1.20.1.4 |
||||
|
vrcSuctPtSuperHeatTemp
Suction super heat temperature in tenths of a degree. Units are given
by temperatureUnits field in deviceInfo. The range is determined by the current temperature units. Celsius: -400 to 1000 Fahrenheit: -400 to 2120 |
decidegreesSNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21239.5.2.30.1.20.1.5 |
||||
|
vrcSuctPtTempSensorFailAlarm
Suction temperature sensor failure alarm state
|
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.20.1.6 |
vrcSuctCfgTable
table.1.3.6.1.4.1.21239.5.2.30.1.21
·
1 row entry
·
3 columns
Table used for VRC suction configuration
Entry in the vrcSuctCfgTable: each entry contains config fields for
VRC suction
VRC suction
Indexes
vrcSuctCfgIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
vrcSuctCfgIndex
Unique id for each entry in the table
|
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.21239.5.2.30.1.21.1.1 |
||||
|
vrcSuctCfgPressCalValue
Suction pressure calibration value in tenths of a bar
|
decibarsInteger32r/w Constraints: range: -100-100 |
.1.3.6.1.4.1.21239.5.2.30.1.21.1.2 |
||||
|
vrcSuctCfgTempSensFailAlmCtrl
Suction temperature sensor failure alarm control:
2 = suspend 3 = open |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21239.5.2.30.1.21.1.3 |