vrcMainCfgRemShutdownAlarmCtrl
VERTIV-V5-MIB ·
.1.3.6.1.4.1.21239.5.2.30.1.3.1.34
Object
column
r/w
Enumeration
Remote shutdown alarm control: 2 = suspend 3 = open
Context
- MIB
- VERTIV-V5-MIB
- OID
.1.3.6.1.4.1.21239.5.2.30.1.3.1.34- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- vrcMainCfgEntry
- Table
- vrcMainCfgTable
- Siblings
- 34
Syntax
Enumeration
Values & Constraints
Enumerated Values
2 | suspend |
3 | open |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vrcMainCfgIndex Unique id for each entry in the table | column | Integer32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.1 |
| vrcMainCfgEevShtSettingMax Max Eev sht in tenths of a degree. Units are given by temperatureUnits
field in deviceInfo. The settable range is determined by the current
temperature units.
Celsius: 50 to 20… | column | decidegrees SNMPv2-SMIInteger32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.10 |
| vrcMainCfgEevValveCloseSht Eev valve close sht in tenths of a degree. Units are given by
temperatureUnits field in deviceInfo. The settable range is determined
by the current temperature units.
Celsius: … | column | decidegrees SNMPv2-SMIInteger32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.11 |
| vrcMainCfgEevMopPressSetting Eev mop pressure setting in tenths of a bar. | column | decibars Integer32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.12 |
| vrcMainCfgLpdt Low pressure dt in seconds | column | seconds Integer32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.13 |
| vrcMainCfgDeadBand Dead band in tenths of a degree. Units are given by temperatureUnits
field in deviceInfo. The settable range is determined by the current
temperature units.
Celsius: 0 to 20
Fa… | column | decidegrees SNMPv2-SMIInteger32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.14 |
| vrcMainCfgOnOffSwitch On-off switch | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.21239.5.2.30.1.3.1.15 |
| vrcMainCfgVacuumState Vacuum state | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.21239.5.2.30.1.3.1.16 |
| vrcMainCfgControlMode Control mode:
1 = supply
2 = return | column | Enumeration | .1.3.6.1.4.1.21239.5.2.30.1.3.1.17 |
| vrcMainCfgManualRunEnable Manual run enable | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.21239.5.2.30.1.3.1.18 |
| vrcMainCfgRemShutdownInput Remote shutdown input | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.21239.5.2.30.1.3.1.19 |
| vrcMainCfgModelSelect Model Selection:
1 = TMM-Local 220V 50/60HZ
2 = TMM-Global 208/230V 50/60HZ
3 = TMM-Global 120V 50/60HZ
4 = SC 220V 50/60HZ
5 = 0U 220V 50/60HZ
6 = SS 208/230V 50/60HZ
7 = SS 120V… | column | Enumeration | .1.3.6.1.4.1.21239.5.2.30.1.3.1.2 |
| vrcMainCfgMonitorShutDownFlag Monitor shutdown flag | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.21239.5.2.30.1.3.1.20 |
| vrcMainCfgFirstOnPassword First on password value | column | Integer32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.21 |
| vrcMainCfgFilterMaintSetting Filter maintenance setting | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.21239.5.2.30.1.3.1.22 |
| vrcMainCfgFilterMaintRemindTime Time between filter maintenance reminders in days | column | days Integer32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.23 |
| vrcMainCfgFilterMaintRemindCtrl Filter maintenance reminder:
1 = close
2 = suspend
3 = open | column | Enumeration | .1.3.6.1.4.1.21239.5.2.30.1.3.1.24 |
| vrcMainCfgCommonAlarmOutputDir Common alarm output direction | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.21239.5.2.30.1.3.1.25 |
| vrcMainCfgHpAbnAlarmSetting Abnormal high pressure alarm value in tenths of a bar | column | decibars Integer32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.26 |
| vrcMainCfgLpAlarmCtrl Low pressure alarm control:
2 = suspend
3 = open | column | Enumeration | .1.3.6.1.4.1.21239.5.2.30.1.3.1.27 |
| vrcMainCfgHpAlarmCtrl High pressure alarm control:
2 = suspend
3 = open | column | Enumeration | .1.3.6.1.4.1.21239.5.2.30.1.3.1.28 |
| vrcMainCfgLpFreqAlarmCtrl Low pressure frequently alarm control:
2 = suspend
3 = open | column | Enumeration | .1.3.6.1.4.1.21239.5.2.30.1.3.1.29 |
| vrcMainCfgSystemTimeYear System time - year | column | Integer32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.3 |
| vrcMainCfgHpFreqAlarmCtrl High pressure frequently alarm control:
2 = suspend
3 = open | column | Enumeration | .1.3.6.1.4.1.21239.5.2.30.1.3.1.30 |
| vrcMainCfgLpSensorFailAlarmCtrl Low pressure sensor failure alarm control:
2 = suspend
3 = open | column | Enumeration | .1.3.6.1.4.1.21239.5.2.30.1.3.1.31 |
| vrcMainCfgHpSensorFailAlarmCtrl High pressure sensor failure alarm control:
2 = suspend
3 = open | column | Enumeration | .1.3.6.1.4.1.21239.5.2.30.1.3.1.32 |
| vrcMainCfgHighWaterAlarmCtrl High water alarm control:
1 = close
2 = suspend
3 = open | column | Enumeration | .1.3.6.1.4.1.21239.5.2.30.1.3.1.33 |
| vrcMainCfgEevCommFailAlarmCtrl Eev communication failure alarm:
2 = suspend
3 = open | column | Enumeration | .1.3.6.1.4.1.21239.5.2.30.1.3.1.35 |
| vrcMainCfgSystemTimeMonth System time - month | column | Integer32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.4 |
| vrcMainCfgSystemTimeDay System time - day | column | Integer32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.5 |
| vrcMainCfgSystemTimeHour System time - hour | column | Integer32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.6 |
| vrcMainCfgSystemTimeMin System time - minutes | column | Integer32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.7 |
| vrcMainCfgSystemTimeSec System time - seconds | column | Integer32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.8 |
| vrcMainCfgEevShtSettingMin Min Eev sht in tenths of a degree. Units are given by temperatureUnits
field in deviceInfo. The settable range is determined by the current
temperature units.
Celsius: 50 to 20… | column | decidegrees SNMPv2-SMIInteger32 | .1.3.6.1.4.1.21239.5.2.30.1.3.1.9 |