pduOutletSwitchState
VERTIV-V5-MIB ·
.1.3.6.1.4.1.21239.5.2.3.5.1.4
Object
column
Enumeration
Switch state of the outlet: 1 = Outlet is on 2 = Outlet is off 3 = Outlet is on, but will turn off after a delay 4 = Outlet is off, but will turn on after a delay 5 = Starting reboot cycle, outlet is on, but will go to the rebootOff(6) state after a delay 6 = Rebooting, outlet is off, but it will turn on after a delay 7 = Cannot get outlet state
Context
- MIB
- VERTIV-V5-MIB
- OID
.1.3.6.1.4.1.21239.5.2.3.5.1.4- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pduOutletSwitchEntry
- Table
- pduOutletSwitchTable
- Siblings
- 12
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | on |
2 | off |
3 | on2off |
4 | off2on |
5 | rebootOn |
6 | rebootOff |
7 | unavailable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pduOutletSwitchIndex Table entry index value | column | Integer32 | .1.3.6.1.4.1.21239.5.2.3.5.1.1 |
| pduOutletSwitchRebootDelay Seconds to wait before powering off the outlet, during
rebootAfterDelay(7) operation. Changing this value has no effect on
pending actions. See pduOutletSwitchControl for more inf… | column | Integer32 | .1.3.6.1.4.1.21239.5.2.3.5.1.10 |
| pduOutletSwitchRebootHoldDelay Seconds to hold the outlet off, before powering on the outlet, during
rebootAfterDelay(7) operation. Changing this value has no effect on
pending actions. See pduOutletSwitchContr… | column | Integer32 | .1.3.6.1.4.1.21239.5.2.3.5.1.11 |
| pduOutletSwitchPoaAction The outlet is set to this state during power-up. The action can be
have one the following values:
1 = Outlet will be turned on
2 = Outlet will stay off
3 = Outlet will be set to l… | column | Enumeration | .1.3.6.1.4.1.21239.5.2.3.5.1.12 |
| pduOutletSwitchPoaDelay Seconds to wait before setting the outlet to the
pduOutletSwitchPoaAction state. The delay starts at power-up. | column | Integer32 | .1.3.6.1.4.1.21239.5.2.3.5.1.13 |
| pduOutletSwitchName PDU outlet name (factory-assigned) | column | OctetString | .1.3.6.1.4.1.21239.5.2.3.5.1.2 |
| pduOutletSwitchLabel PDU outlet label (user-defined) | column | OctetString | .1.3.6.1.4.1.21239.5.2.3.5.1.3 |
| pduOutletSwitchRelayFailure Tells if the outlet relay has failed. In normal operation, the value
will be false(2). | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.21239.5.2.3.5.1.5 |
| pduOutletSwitchControl Used for manual control of the outlet. If the outlet is in manual
mode, this field can be set to one of the following values:
1 = Cancel pending operation
2 = Turn outlet on
3 = A… | column | Enumeration | .1.3.6.1.4.1.21239.5.2.3.5.1.6 |
| pduOutletSwitchTimeToAction Seconds until an outlet state change. The value of
pduOutletSwitchState tells what state the outlet will be set, after
the delay. | column | Integer32 | .1.3.6.1.4.1.21239.5.2.3.5.1.7 |
| pduOutletSwitchOnDelay Seconds to wait before powering on the outlet, during onAfterDelay(3)
operation. Changing this value has no effect on pending actions. | column | Integer32 | .1.3.6.1.4.1.21239.5.2.3.5.1.8 |
| pduOutletSwitchOffDelay Seconds to wait before powering off the outlet, during
offAfterDelay(5) operation. Changing this value has no effect on
pending actions. | column | Integer32 | .1.3.6.1.4.1.21239.5.2.3.5.1.9 |