VERTIV-IMD-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
12
Rows
12
Columns
117
.1.3.6.1.4.1.21239.5.2.3.1 · 1 row entry · 12 columns
PDU general information
pduMainEntry entry .1.3.6.1.4.1.21239.5.2.3.1.1
Entry in the pduMainTable table: each entry contains an index and other sensor details
Indexes
pduMainIndex
Column Syntax OID
pduMainIndex
Table entry index value
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.21239.5.2.3.1.1.1
pduMainSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21239.5.2.3.1.1.2
pduMainName
PDU name (factory assigned)
OctetString
Constraints:
range: 1-25
.1.3.6.1.4.1.21239.5.2.3.1.1.3
pduMainLabel
PDU label (user-defined)
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.3.1.1.4
pduMainAvail
Device availability:
0 = Unavailable
1 = Available
2 = Partially Unavailable
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.3.1.1.5
pduMeterType
Current meter type:
0 = Wye
1 = Delta
Enumeration
Enumerated Values:
0wye
1delta
.1.3.6.1.4.1.21239.5.2.3.1.1.6
pduTotalName
Total Name (factory-assigned)
OctetString
Constraints:
range: 1-25
.1.3.6.1.4.1.21239.5.2.3.1.1.7
pduTotalLabel
Total Label (user-defined)
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.3.1.1.8
pduTotalRealPower
PDU total real power
wattsUnsigned32
Constraints:
range: 0-9999
.1.3.6.1.4.1.21239.5.2.3.1.1.9
pduTotalApparentPower
PDU total apparent power
volt-ampsUnsigned32
Constraints:
range: 0-9999
.1.3.6.1.4.1.21239.5.2.3.1.1.10
pduTotalPowerFactor
PDU total power factor
%Unsigned32
Constraints:
range: 0-100
.1.3.6.1.4.1.21239.5.2.3.1.1.11
pduTotalEnergy
PDU total accumulated energy in watt-hours
watt-hoursUnsigned32
Constraints:
range: 0-9999000
.1.3.6.1.4.1.21239.5.2.3.1.1.12
.1.3.6.1.4.1.21239.5.2.3.2 · 1 row entry · 15 columns
PDU phases information
pduPhaseEntry entry .1.3.6.1.4.1.21239.5.2.3.2.1
Entry in the pduPhaseTable table: each entry contains an index and other sensor details
Indexes
pduPhaseIndex
Column Syntax OID
pduPhaseIndex
Table entry index value
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.21239.5.2.3.2.1.1
pduPhaseName
PDU phase name (factory-assigned)
OctetString
Constraints:
range: 1-25
.1.3.6.1.4.1.21239.5.2.3.2.1.2
pduPhaseLabel
PDU phase label (user-defined)
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.3.2.1.3
pduPhaseVoltage
PDU phase voltage in tenths of a volt
decivolts (rms)Unsigned32
Constraints:
range: 0-3100
.1.3.6.1.4.1.21239.5.2.3.2.1.4
pduPhaseVoltageMax
Highest RMS voltage measured on this phase, since power-up or last reset. The value is given in tenths of a volt
decivolts (rms)Unsigned32
Constraints:
range: 0-3100
.1.3.6.1.4.1.21239.5.2.3.2.1.5
pduPhaseVoltageMin
Lowest RMS voltage measured on this phase, since power-up or last reset. The value is given in tenths of a volt
decivolts (rms)Unsigned32
Constraints:
range: 0-3100
.1.3.6.1.4.1.21239.5.2.3.2.1.6
pduPhaseVoltagePeak
Highest instantaneous voltage measured on this phase, since power-up or last reset. The value is given in tenths of a volt. This object may not exist on all platforms, due to hardware differences.
decivoltsUnsigned32
Constraints:
range: 0-4400
.1.3.6.1.4.1.21239.5.2.3.2.1.7
pduPhaseCurrent
PDU phase current reading in hundreths of an amp.
centiamps (rms)Unsigned32
Constraints:
range: 0-9900
.1.3.6.1.4.1.21239.5.2.3.2.1.8
pduPhaseCurrentMax
Highest RMS current measured on this phase, since power-up or last reset. The value is given in hundreths of an amp.
centiamps (rms)Unsigned32
Constraints:
range: 0-9900
.1.3.6.1.4.1.21239.5.2.3.2.1.9
pduPhaseCurrentMin
Lowest RMS current measured on this phase, since power-up or last reset. The value is given in hundreths of an amp.
centiamps (rms)Unsigned32
Constraints:
range: 0-9900
.1.3.6.1.4.1.21239.5.2.3.2.1.10
pduPhaseCurrentPeak
Highest instantaneous current measured on ths phase, since power-up or last reset. The value is given in hundreths of an amp. This object may not exist on all platforms, due to hardware differences.
centiampsUnsigned32
Constraints:
range: 0-15000
.1.3.6.1.4.1.21239.5.2.3.2.1.11
pduPhaseRealPower
Real power for phase in watts
wattsUnsigned32
Constraints:
range: 0-9999
.1.3.6.1.4.1.21239.5.2.3.2.1.12
pduPhaseApparentPower
Apparent power for phase in volt-amps
volt-ampsUnsigned32
Constraints:
range: 0-9999
.1.3.6.1.4.1.21239.5.2.3.2.1.13
pduPhasePowerFactor
Power factor for phase
%Unsigned32
Constraints:
range: 0-100
.1.3.6.1.4.1.21239.5.2.3.2.1.14
pduPhaseEnergy
Accumulated energy for phase in watt-hours
watt-hoursUnsigned32
Constraints:
range: 0-9999000
.1.3.6.1.4.1.21239.5.2.3.2.1.15
.1.3.6.1.4.1.21239.5.2.3.3 · 1 row entry · 7 columns
PDU breaker information
pduBreakerEntry entry .1.3.6.1.4.1.21239.5.2.3.3.1
Entry in the pduBreakerTable table: each entry contains an index and other sensor details
Indexes
pduBreakerIndex
Column Syntax OID
pduBreakerIndex
Table entry index value
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.21239.5.2.3.3.1.1
pduBreakerName
PDU breaker name (factory-assigned)
OctetString
Constraints:
range: 1-25
.1.3.6.1.4.1.21239.5.2.3.3.1.2
pduBreakerLabel
PDU breaker label (user-defined)
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.3.3.1.3
pduBreakerCurrent
PDU breaker current reading in hundreths of an amp
centiamps (rms)Unsigned32
Constraints:
range: 0-9900
.1.3.6.1.4.1.21239.5.2.3.3.1.4
pduBreakerCurrentMax
Highest RMS current measured on this breaker, since power-up or last reset. The value is given in hundreths of an amp.
centiamps (rms)Unsigned32
Constraints:
range: 0-9900
.1.3.6.1.4.1.21239.5.2.3.3.1.5
pduBreakerCurrentMin
Lowest RMS current measured on this breaker, since power-up or last reset. The value is given in hundreths of an amp.
centiamps (rms)Unsigned32
Constraints:
range: 0-9900
.1.3.6.1.4.1.21239.5.2.3.3.1.6
pduBreakerCurrentPeak
Highest instantaneous current measured on this breaker, since power-up or last reset. The value is given in hundreths of an amp. This object may not exist on all platforms, due to hardware differences.
centiampsUnsigned32
Constraints:
range: 0-15000
.1.3.6.1.4.1.21239.5.2.3.3.1.7
.1.3.6.1.4.1.21239.5.2.3.4 · 1 row entry · 7 columns
PDU line current information
pduLineEntry entry .1.3.6.1.4.1.21239.5.2.3.4.1
Entry in the pduLineTable table: each entry contains an index and other sensor details
Indexes
pduLineIndex
Column Syntax OID
pduLineIndex
Table entry index value
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.21239.5.2.3.4.1.1
pduLineName
PDU line name (factory-assigned)
OctetString
Constraints:
range: 1-25
.1.3.6.1.4.1.21239.5.2.3.4.1.2
pduLineLabel
PDU line label (user-defined)
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.3.4.1.3
pduLineCurrent
PDU line current reading in hundreths of an amp
centiamps (rms)Unsigned32
Constraints:
range: 0-9900
.1.3.6.1.4.1.21239.5.2.3.4.1.4
pduLineCurrentMax
Highest RMS current measured on this line, since power-up or last reset. The value is given in hundreths of an amp.
centiamps (rms)Unsigned32
Constraints:
range: 0-9900
.1.3.6.1.4.1.21239.5.2.3.4.1.5
pduLineCurrentMin
Lowest RMS current measured on this line, since power-up or last reset. The value is given in hundreths of an amp.
centiamps (rms)Unsigned32
Constraints:
range: 0-9900
.1.3.6.1.4.1.21239.5.2.3.4.1.6
pduLineCurrentPeak
Highest instantaneous current measured on this line, since power-up or last reset. The value is given in hundreths of an amp. This object may not exist on all platforms, due to hardware differences.
centiampsUnsigned32
Constraints:
range: 0-15000
.1.3.6.1.4.1.21239.5.2.3.4.1.7
.1.3.6.1.4.1.21239.5.2.4 · 1 row entry · 5 columns
Remote Temperature (RT) sensor
tempSensorEntry entry .1.3.6.1.4.1.21239.5.2.4.1
Entry in the tempSensorTable table: each entry contains an index and other sensor details
Indexes
tempSensorIndex
Column Syntax OID
tempSensorIndex
Table entry index value
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.21239.5.2.4.1.1
tempSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21239.5.2.4.1.2
tempSensorLabel
User-defined label
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.4.1.3
tempSensorAvail
Device availability:
0 = Unavailable
1 = Available
2 = Partially Unavailable
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.4.1.4
tempSensorTemp
Temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
decidegreesInteger32
Constraints:
range: -400-2540
.1.3.6.1.4.1.21239.5.2.4.1.5
.1.3.6.1.4.1.21239.5.2.5 · 1 row entry · 8 columns
Remote Airflow, Humidity, Temperature and Dewpoint (AFHT3) Sensor
airFlowSensorEntry entry .1.3.6.1.4.1.21239.5.2.5.1
Entry in the airFlowSensorTable table: each entry contains an index and other sensor details
Indexes
airFlowSensorIndex
Column Syntax OID
airFlowSensorIndex
Table entry index value
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.21239.5.2.5.1.1
airFlowSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21239.5.2.5.1.2
airFlowSensorLabel
User-defined label
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.5.1.3
airFlowSensorAvail
Device availability:
0 = Unavailable
1 = Available
2 = Partially Unavailable
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.5.1.4
airFlowSensorTemp
Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
decidegreesInteger32
Constraints:
range: -400-2540
.1.3.6.1.4.1.21239.5.2.5.1.5
airFlowSensorFlow
Airflow reading. Still air will be less than 20, while rushing air will be around 100.
Integer32
Constraints:
range: 0-100
.1.3.6.1.4.1.21239.5.2.5.1.6
airFlowSensorHumidity
Humidity reading
%Integer32
Constraints:
range: 0-100
.1.3.6.1.4.1.21239.5.2.5.1.7
airFlowSensorDewPoint
Dewpoint reading in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
decidegreesInteger32
Constraints:
range: -400-2540
.1.3.6.1.4.1.21239.5.2.5.1.8
.1.3.6.1.4.1.21239.5.2.6 · 1 row entry · 7 columns
Remote Dew Point sensor
dewPointSensorEntry entry .1.3.6.1.4.1.21239.5.2.6.1
Entry in the dewPointSensorTable table: each entry contains an index and other sensor details
Indexes
dewPointSensorIndex
Column Syntax OID
dewPointSensorIndex
Table entry index value
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.21239.5.2.6.1.1
dewPointSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21239.5.2.6.1.2
dewPointSensorName
User-defined label
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21239.5.2.6.1.3
dewPointSensorAvail
Device availability:
0 = Unavailable
1 = Available
2 = Partially Unavailable
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.6.1.4
dewPointSensorTemp
Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
decidegreesInteger32
Constraints:
range: -40-200
.1.3.6.1.4.1.21239.5.2.6.1.5
dewPointSensorHumidity
Humidity reading
%Integer32
Constraints:
range: 0-100
.1.3.6.1.4.1.21239.5.2.6.1.6
dewPointSensorDewPoint
Current reading for Dew-point in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
decidegreesInteger32
Constraints:
range: -40-200
.1.3.6.1.4.1.21239.5.2.6.1.7
.1.3.6.1.4.1.21239.5.2.7 · 1 row entry · 7 columns
Remote CCAT sensor
ccatSensorEntry entry .1.3.6.1.4.1.21239.5.2.7.1
Entry in the ccatSensorTable table: each entry contains an index and other sensor details
Indexes
ccatSensorIndex
Column Syntax OID
ccatSensorIndex
Table entry index value
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.21239.5.2.7.1.1
ccatSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21239.5.2.7.1.2
ccatSensorName
User-defined label
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21239.5.2.7.1.3
ccatSensorAvail
Device availability:
0 = Unavailable
1 = Available
2 = Partially Unavailable
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.7.1.4
ccatSensorValue
CCAT sensor reading
Integer32
Constraints:
range: -100-5000
.1.3.6.1.4.1.21239.5.2.7.1.5
ccatSensorType
CCAT sensor type
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21239.5.2.7.1.6
ccatSensorDescription
CCAT sensor value description
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21239.5.2.7.1.7
.1.3.6.1.4.1.21239.5.2.8 · 1 row entry · 14 columns
Remote Temperature x 3, Humidity and Dewpoint Sensor
t3hdSensorEntry entry .1.3.6.1.4.1.21239.5.2.8.1
Entry in the t3hdSensorTable table: each entry contains an index and other sensor details
Indexes
t3hdSensorIndex
Column Syntax OID
t3hdSensorIndex
Table entry index value
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.21239.5.2.8.1.1
t3hdSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21239.5.2.8.1.2
t3hdSensorLabel
User-defined label
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.8.1.3
t3hdSensorAvail
Device availability:
0 = Unavailable
1 = Available
2 = Partially Unavailable
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.8.1.4
t3hdSensorIntLabel
Internal label (user-defined)
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.8.1.5
t3hdSensorIntTemp
Internal temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
decidegreesInteger32
Constraints:
range: -400-2540
.1.3.6.1.4.1.21239.5.2.8.1.6
t3hdSensorIntHumidity
Internal Humidity
%Integer32
Constraints:
range: 0-100
.1.3.6.1.4.1.21239.5.2.8.1.7
t3hdSensorIntDewPoint
Internal dewpoint in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
decidegreesInteger32
Constraints:
range: -400-2540
.1.3.6.1.4.1.21239.5.2.8.1.8
t3hdSensorExtAAvail
External A status:
0 =Unavailable
1 =Available
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.8.1.9
t3hdSensorExtALabel
External A label (user-defined)
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.8.1.10
t3hdSensorExtATemp
External A temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
decidegreesInteger32
Constraints:
range: -400-2540
.1.3.6.1.4.1.21239.5.2.8.1.11
t3hdSensorExtBAvail
External B status:
0 = Unavailable
1 = Available
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.8.1.12
t3hdSensorExtBLabel
External B label (user-defined)
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.8.1.13
t3hdSensorExtBTemp
External B temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
decidegreesInteger32
Constraints:
range: -400-2540
.1.3.6.1.4.1.21239.5.2.8.1.14
.1.3.6.1.4.1.21239.5.2.9 · 1 row entry · 7 columns
Remote Temperature, Humidity and Dewpoint (THD) Sensor
thdSensorEntry entry .1.3.6.1.4.1.21239.5.2.9.1
Entry in the thdSensorTable table: each entry contains an index and other sensor details
Indexes
thdSensorIndex
Column Syntax OID
thdSensorIndex
Table entry index value
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.21239.5.2.9.1.1
thdSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21239.5.2.9.1.2
thdSensorLabel
User-defined label
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.9.1.3
thdSensorAvail
Device availability:
0 = Unavailable
1 = Available
2 = Partially Unavailable
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.9.1.4
thdSensorTemp
Temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
decidegreesInteger32
Constraints:
range: -400-2540
.1.3.6.1.4.1.21239.5.2.9.1.5
thdSensorHumidity
Humidity value
%Integer32
Constraints:
range: 0-100
.1.3.6.1.4.1.21239.5.2.9.1.6
thdSensorDewPoint
Dewpoint value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
decidegreesInteger32
Constraints:
range: -400-2540
.1.3.6.1.4.1.21239.5.2.9.1.7
.1.3.6.1.4.1.21239.5.2.10 · 1 row entry · 15 columns
Remote Power Manager Sensor
rpmSensorEntry entry .1.3.6.1.4.1.21239.5.2.10.1
Entry in the rpmSensorTable table: each entry contains an index and other sensor details
Indexes
rpmSensorIndex
Column Syntax OID
rpmSensorIndex
Table entry index value
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.21239.5.2.10.1.1
rpmSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21239.5.2.10.1.2
rpmSensorName
Friendly Name
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21239.5.2.10.1.3
rpmSensorAvail
Device availability
0 = Unavailable
1 = Available
2 = Partially Unavailable
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.10.1.4
rpmSensorEnergy
RPM Sensor Accumulated Energy
kWhSNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.10.1.5
rpmSensorVoltage
RPM Sensor Voltage
Volts (rms)SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.10.1.6
rpmSensorVoltageMax
RPM Sensor Voltage (Max)
Volts (rms)SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.10.1.7
rpmSensorVoltageMin
RPM Sensor Voltage (Min)
Volts (rms)SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.10.1.8
rpmSensorVoltagePeak
RPM Sensor Voltage (Peak)
VoltsSNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.10.1.9
rpmSensorCurrent
RPM Sensor Current reading in deciAmps
0.1 Amps (rms)SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.10.1.10
rpmSensorRealPower
RPM Sensor Real Power
WattsSNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.10.1.11
rpmSensorApparentPower
RPM Sensor Apparent Power
Volt-AmpsSNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.10.1.12
rpmSensorPowerFactor
RPM Sensor Power Factor
%SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.10.1.13
rpmSensorOutlet1
RPM Sensor Outlet 1 State: 0 = off, 1 = on
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.10.1.14
rpmSensorOutlet2
RPM Sensor Outlet 2 State:
0 = off
1 = on
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.10.1.15
.1.3.6.1.4.1.21239.5.2.11 · 1 row entry · 13 columns
Analog measurement (A2D) sensor (voltage, current, or dry-contact)
a2dSensorEntry entry .1.3.6.1.4.1.21239.5.2.11.1
Entry in the a2dSensorTable table: each entry contains an index and other sensor details
Indexes
a2dSensorIndex
Column Syntax OID
a2dSensorIndex
Table entry index value
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.21239.5.2.11.1.1
a2dSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21239.5.2.11.1.2
a2dSensorLabel
User-defined label
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.11.1.3
a2dSensorAvail
Device availability:
0 = Unavailable
1 = Available
2 = Partially Unavailable
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.21239.5.2.11.1.4
a2dSensorValue
Analog measurement value, within either a user-defined or preset range, depending on a2dSensorMode.
Integer32
Constraints:
range: -1000000-1000000
.1.3.6.1.4.1.21239.5.2.11.1.5
a2dSensorDisplayValue
For current/voltage modes, the analog value is given as a string. In binary modes, the value is either a2dSensorLowLabel or a2dSensorHighLabel, based on a2dSensorValue.
OctetString
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.11.1.6
a2dSensorMode
Binary modes have two states represented by the values 0 (low) or 1 (high). These correspond to a2dSensorLowLabel and a2dSensorHighLabel. Current and voltage modes provide a scaled value from a2dSensorMin to a2dSensorMa…
Enumerationr/w
Enumerated Values:
1door
2powerFailure
3flood
4wscLeak
5wscFault
6smoke
7ivsNegGnd
8ivsPosGnd
9customVoltage
10customBinary
11customCurrent
.1.3.6.1.4.1.21239.5.2.11.1.7
a2dSensorUnits
The units for the analog value. If a2dSensorMode is customVoltage(9) or customCurrent(11), then this field has a user-defined value. Otherwise, the value is fixed, based on mode.
OctetStringr/w
Constraints:
range: 0-7
.1.3.6.1.4.1.21239.5.2.11.1.8
a2dSensorMin
Minimum analog value, given as an integer. The analog measurement is scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is customVoltage(9) or customCurrent(11), then this field has a user-defined value.…
Integer32r/w
Constraints:
range: -1000000-1000000
.1.3.6.1.4.1.21239.5.2.11.1.9
a2dSensorMax
Maximum analog value, given as an integer. The analog measurement is scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is customVoltage(9) or customCurrent(11), then this field has a user-defined value.…
Integer32r/w
Constraints:
range: -1000000-1000000
.1.3.6.1.4.1.21239.5.2.11.1.10
a2dSensorLowLabel
Label for 0 (low) binary value. This field is only applicable if a2dSensorMode is one of the binary modes. If a2dSensorMode is customBinary(10), then this field is user-defined. Otherwise, it has a pre-defined value bas…
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.11.1.11
a2dSensorHighLabel
Label for 1 (high) binary value. The field is only applicable if a2dSensorMode is one of the binary modes. If a2dSensorMode is customBinary(10), then this field is user-defined. Otherwise, it has a pre-defined value bas…
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.11.1.12
a2dSensorAnalogLabel
Label for the analog measurement
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.21239.5.2.11.1.13