LUM-EQUIPMENT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
6
Rows
6
Columns
130
.1.3.6.1.4.1.8708.2.11.2.2.1 · 1 row entry · 28 columns
The subrack list.
equipmentSubrackEntry entry .1.3.6.1.4.1.8708.2.11.2.2.1.1
An entry in the subrack list.
Indexes
equipmentSubrackIndex
Column Syntax OID
equipmentSubrackIndex
An arbitrary index assigned to each
subrack entry.
Unsigned32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.8708.2.11.2.2.1.1.1
equipmentSubrackName
The name of the subrack, for example 'sub1'
where the number indicates the subrack number.
LUM-TCMgmtNameString
Textual Convention: LUM-TCMgmtNameString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.2.1.1.2
equipmentSubrackSubrack
The number of the subrack.
LUM-TCSubrackNumberr/w
Textual Convention: LUM-TCSubrackNumber Unsigned32
Type Constraints:
range: 0..15
.1.3.6.1.4.1.8708.2.11.2.2.1.1.3
equipmentSubrackDescr
User configurable label.
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.2.1.1.4
equipmentSubrackInvPhysIndexOrZero
The row in the invPhysTable for this subrack.
Set to 0 if not known.
Unsigned32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.8708.2.11.2.2.1.1.5
equipmentSubrackAllFanUnitsFailed
All fan units in a subrack have failed.

A(ctivation): fanUnitFailed active for all fans
within a subrack.

D(e-activiation): fanUnitFailed cleared for one
fan unit.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.2.1.1.6
equipmentSubrackRowStatus
SNMP administrivia.
Manages creation and deletion of conceptual rows.
See also SNMPv2-TC.
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.8708.2.11.2.2.1.1.7
equipmentSubrackExpectedType
The expected subrack type.
EquipmentSubrackTyper/w
Textual Convention: EquipmentSubrackType Enumeration
Type Values:
0undefined
1tm300
2tm3000
3tm301
4tm101
5tm101p
6aux
7tm102
8mba1
9mba2
10mba2E
11tm102pas
12tm102pas3
13tm3000ii
14tm2000
15tm301ii
16tmFha1UDc1
17tmRfuAc1
18tmEmxp1UDc
19tmHdea1600Dc
20tm3000iie
9002ts1100Subrack2Slots
9006tm206Subrack6Slots
9011ts1100Subrack8Slots
9013ts1100Subrack12Slots
.1.3.6.1.4.1.8708.2.11.2.2.1.1.8
equipmentSubrackActualType
The actual subrack type. If an unexpected
subrack has been detected this variable can be
used to see what type of subrack has been
detected.
EquipmentSubrackType
Textual Convention: EquipmentSubrackType Enumeration
Type Values:
0undefined
1tm300
2tm3000
3tm301
4tm101
5tm101p
6aux
7tm102
8mba1
9mba2
10mba2E
11tm102pas
12tm102pas3
13tm3000ii
14tm2000
15tm301ii
16tmFha1UDc1
17tmRfuAc1
18tmEmxp1UDc
19tmHdea1600Dc
20tm3000iie
9002ts1100Subrack2Slots
9006tm206Subrack6Slots
9011ts1100Subrack8Slots
9013ts1100Subrack12Slots
.1.3.6.1.4.1.8708.2.11.2.2.1.1.9
equipmentSubrackUnexpectedType
A type of subrack not matching the expected
type is present.

A: A subrack with type different from the
expected type is present (even if the subrack
is not activated).

D: The type matches t…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.2.1.1.10
equipmentSubrackTemp
The temperature in the subrack in 0.1 degrees centigrade.
Integer32
Constraints:
range: -1000-1000
.1.3.6.1.4.1.8708.2.11.2.2.1.1.11
equipmentSubrackTempHighExceeded
The threshold for environmental temperature
in the subrack is exceeded.

A: The temperature exceeds the associated threshold.

D: Temperature is 0.5 degrees centigrade below the
associated th…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.2.1.1.12
equipmentSubrackTempThreshold
The threshold for temperature alarm in the
subrack in 0.1 degrees centigrade.
Integer32r/w
Constraints:
range: -100-800
.1.3.6.1.4.1.8708.2.11.2.2.1.1.13
equipmentSubrackDataChanged
The subrack data (dipswitches for subrackId and/or
system mode) has been changed. Changing this data might
affect the system behaviour after the next restart.

A: The subrack data has been changed since st…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.2.1.1.14
equipmentSubrackSystemModeSet
The value read from the system mode
dipswitches at startup of the CU was
diffrent from 0.

This will affect the behaviour of the
system.

If the lowest bit is set, the backup
is read from the…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.2.1.1.15
equipmentSubrackEffectiveSystemMode
The value of the system mode dipswitches
read at startup. This value determines the
system behaviour.
Unsigned32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.8708.2.11.2.2.1.1.16
equipmentSubrackCurrentSystemMode
The current value of the system mode
dipswitches. Will be used at the next
restart.
Unsigned32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.8708.2.11.2.2.1.1.17
equipmentSubrackAdminStatus
The administrative state of the subrack.

down - This subrack should not be monitored.
Suppresses alarms.

up - The subrack should be monitored.
Enumerationr/w
Enumerated Values:
1down
2up
.1.3.6.1.4.1.8708.2.11.2.2.1.1.18
equipmentSubrackOperStatus
The operational state of the subrack.

notPresent - The subrack is not available.

down - The subrack remains in the 'down'-state
when adminStatus is set to 'down'.

up - The su…
Enumeration
Enumerated Values:
1notPresent
2down
3up
.1.3.6.1.4.1.8708.2.11.2.2.1.1.19
equipmentSubrackObjectProperty
Property mask.
LUM-TCObjectProperty
Textual Convention: LUM-TCObjectProperty Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.8708.2.11.2.2.1.1.20
equipmentSubrackShelfLength
Length of the half-height slot divider shelf. To be
manually entered by the user. A value of 0 is
interpreted as 'not yet defined by user'.
Unsigned32r/w
Constraints:
range: 0-32
.1.3.6.1.4.1.8708.2.11.2.2.1.1.21
equipmentSubrackLANModuleMissing
The subrack LAN/DCN module is missing.

A(ctivation): LAN/DCN module disconnected from subrack
for more than 2 seconds.

D(e-activiation): LAN/DCN module connected to subrack
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.2.1.1.22
equipmentSubrackExpectedFirstPbSlot
The lowest slot number where it is possible to
configure a passive board. Automatically configured
to the actual value supported by hardware if the
hardware is present on subrack configuration.

If no hard…
FirstPbSlotr/w
Textual Convention: FirstPbSlot Enumeration
Type Values:
0undefined
3slot3
4slot4
13slot13
.1.3.6.1.4.1.8708.2.11.2.2.1.1.23
equipmentSubrackActualFirstPbSlot
The actual lowest slot number where it is possible
to configure a passive board.

When no subrack hardware is present, this value is
'undefined'.
FirstPbSlot
Textual Convention: FirstPbSlot Enumeration
Type Values:
0undefined
3slot3
4slot4
13slot13
.1.3.6.1.4.1.8708.2.11.2.2.1.1.24
equipmentSubrackFirstPbSlotMismatch
The expected first passive slot allows more passive
boards than the hardware supports.

A(ctivation): A subrack and control unit combination
which supports fewer passive boards
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.2.1.1.25
equipmentSubrackAid
The access identifier (AID) of the product.
The format is according to GR-833.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.2.1.1.26
equipmentSubrackPhysicalLocation
The Physical location of the product.
The format is according to GR-833.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.2.1.1.27
equipmentSubrackChangeExpectedType
Command to change expected type,
used when upgrading subrack to a new version,
e.g TM3000 to TM3000/II
LUM-TCCommandString
Textual Convention: LUM-TCCommandString OctetString
.1.3.6.1.4.1.8708.2.11.2.2.1.1.28
.1.3.6.1.4.1.8708.2.11.2.3.1 · 1 row entry · 51 columns
The board list.
equipmentBoardEntry entry .1.3.6.1.4.1.8708.2.11.2.3.1.1
An entry in the board list.
One entry for each slot.
Indexes
equipmentBoardIndex
Column Syntax OID
equipmentBoardIndex
An arbitrary index assigned to each
board entry.
Unsigned32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.8708.2.11.2.3.1.1.1
equipmentBoardName
The name of the board, for example 'tpmr2500:1:2'
where the first number indicates in which sub-rack
the board is present and the second number
in which slot.
LUM-TCMgmtNameString
Textual Convention: LUM-TCMgmtNameString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.3.1.1.2
equipmentBoardExpectedType
The expected board type.
EquipmentBoardTyper/w
Textual Convention: EquipmentBoardType Enumeration
Type Values:
0undefined
1cu
2tpMr2500
3oxc8
4oxc16
5ocu2
6mxp028
7ad1AB
8ad1BA
9ad2AB
10ad2BA
11ad4AB
12ad4BA
13tpDGbE
14oa
15mdu8Ext
16mdu8Term
17ocu4
18mxp004
19ad2oaAB
20ad2oaBA
21oa2
22adcwdm
23ad1spr
24tp10G
25tpLMr2500
26cu1osc
27cu2osc
28obu
29sync2Mhz
30mxp8
31mxp16
32tpDGbED
33tpDGbEC
34tpDFcD
35tpDFcC
36tpFcGbED
37tpFcGbEC
38tpTFcD
39tpQMr
40mdu4TermAB
41mdu4TermBA
42ad1cwdm
43ad2cwdm
44tp10GLAN
45tp10GRC
46escon8
47oa1x15dBm
48oa2x15dBm
49gxp2500
50gxp2500Sfp
51gxp10G
52tpDGbEDv2
53tpDGbESfp
54tpDFcDv2
55tpDFcSfp
56ad2x1cwdm
57ad2x2cwdm
58mdu8Term2
59tpDDGbE
60fpuOas2824
61mu2F8C
62du2F8C
63tpD10GL
64tpDDGbER
65tp10GBu
66tp10GLANBu
67tp10GClBu
68tp10GLANClBu
69mdu8EvenExt
70mdu8EvenTerm
71oapre1x17dBm
72oa2x17dBm
73oiuc100200
74oapow1x17dBm
75oa1x17dBm
76gbe9Mxp10G
77ad1dwdm2F
78ad1cwdm2F
79mdu4Ext2F
80mdu4Term2F
81voa8ch
82oa1x20dBm
83oa2x20dBm
84fpuYm235
85ad4dwdm2F
86tpQMri
87oar450c
88cuSfp
89tpMr25v2
90tpD10GbE
91tpD10GbER
92mdu4ExtAB
93mdu4ExtBA
94oiuc50100
95mROADM1P800
96edu6pGbE
97tp10GClTc
98mxp4x2G5
99oa1xLG20dBm
100oa2xLG20dBm
101oa1xFG10dBm
102oa2xFG10dBm
103tp10GOtnTc
104mdu40Even
105mdu40Odd
106mdu8Ee
107mdu8Eo
108ocm2p
109msMxp
110voa8chii
111msMxpR
112msMxpDQgbe
113tp10GTcEr
114gbe10Emxp10G
115edu12pGbE
116gbeMxp10GFEC
117roadm1x4G100
118dQgbeMxpR
119tpQMS
120tpQMSR
121gbe22Emxp10G
122oa1x26dBm
123pcu2p
124mxp4x2G5Oc
125voa2ch
126msMxp10GTCEr
127msMxp10G
128msMxpQMS2G5
129gbe22Emxp10Gii
130bsu1x5Even
131bsu1x5Odd
132gbe10Emxp10Gii
133mba1
134mba1SonetDeprecated
135mba2
136mba2SonetDeprecated
137mxpmbh1Sdh
138mxpmbh1Sonet
139roadm1x8G50
140ad4Even50
141ad4Odd50
142emxp80Gii
143msMxpQMS2G5R
144mxp8iiSdh
145mxp8iiSonet
146mba2E
147mba2ptpSdh
148mba2ptpSonet
149mba2EptpSdh
150mba2EptpSonet
151mdu40EvenL
152mdu40OddL
153oa1x20dBmVg
154oa2x20dBmVg
155roadm1x2G100
156roadm1x2G50
157tpq10Gfec
158cuSfpii
159coD40ev
160coD40eve
161coD40od
162coD40ode
163dcDk652km20
164dcDk652km40
165dcDk652km60
166dcDk652km80
167dcP652km40
168dcP652km60
169dcP652km80
170dcP652km100
171dcP652km120
172emxp40Gii
173tpqmp
174tpq10GfecReg
175mdu16cl50g
176voa8chsfp
177msTp40G
178msMxp40G
179mxp10gotn
180emxp62iie
181emxp120iie
182ocudq
183tm4700
184tm4011
185tm100mxp
186tm100tp
187tm100reg
188ocuseed2p
189oa2x21seed
190oypatchcord
191tpq10gfeci
192tpq10gfecregi
193tphex10gotn
194emxp48iie
195tp100gotn
196emxp220iie
197tpmrHL16G
198fhmxp10g
199mxp100gotn
200cuSfpiii
201emxp240iie
202tpmrHL16GUni
203fpu1
204oaraed21hghyb
205oaraed21hgind
206emxp3
207dcDk652km100
208dcDk652km120
209dcP652km20
210fhau1
211fha1u1
212oa1x20dBmVg2
213oa2x20dBmVg2
214ptio10g
215fxp400gotn
216compo24
217rfu1
218coD919926
219coD927934
220coD935942
221coD943950
222oD951958
223coD919926e
224coD927934e
225coD935942e
226coD943950e
227coD951958e
228co4
229co5
230codsf20eva
231codsf20evb
232codsf4919
233codsf4926
234codsf4927
235codsf4934
236codsf4935
237codsf4942
238codsf4943
239codsf4950
240codsf4951
241codsf4958
242codsf2919
243codsf2922
244codsf2923
245codsf2926
246codsf2927
247codsf2930
248codsf2931
249codsf2934
250codsf2935
251codsf2938
252codsf2939
253codsf2942
254codsf2943
255codsf2946
256codsf2947
257codsf2950
258codsf2951
259codsf2954
260codsf2955
261codsf2958
262tp100gotnii
263roadm1x4f
264ptio100g
265oadm2ch
266emxp1u
267emxp1us
268mxp200gotn
269emxp440
270oaraed20lghyb
271roadm1x9f
272ocm8p
273ad1c2fotdr
274hdea1600
275oa1xLG20dBmb
276oa2xLG20dBmb
277oa1x20dBmVgb
278oa2x20dBmVgb
279codsf24mpo10104
280otdr8p
281coD48ev
282coD48od
1001tgCo4
1005tgCo5
1006tgCo6
1007tgCo7
1008tgCo8
1009tgCo9
1010tgCo10
1011tgCo11
1012tgCo12
1014tgCo14
1015tgCo15
1016tgCo16
1040tgCoDxxxyyy
1041tgCoD40ev
1042tgCoD40eve
1043tgCoD40od
1044tgCoD40ode
1050tgCoBSU1x5ev
1051tgCoBSU1x5od
1055tgCad86XX04
1056tgCad86XX02
1057tgCoDSF2ch9XXAB
1058tgCoDSF4ch9XXAB
1059tgCoDSF2ch9XXBA
1060tgCoDSF4ch9XXBA
1061tgTcosf2x1b
1062tgTcosf2x1d
1070tgCoD4XXX
1080tgCoDSF20
1081tgCoDSF20evA
1082tgCoDSF20evB
1083tgCoDSF20odA
1084tgCoDSF20odB
1085tgCoSFBSU1x5ev
2012tgTco12
2014tgTco14
10000acd2pGbE
10001acd5pGbE
10002acd10G
10003edu5GT
10004edu10GLT
10005edu10GLTS
20000nidGE
20001nidSfp155
20002nidSfp622
20003nidSfpVc12
20004nidSfp2488
220401ts1100EthMux4p
250101ts1100OPU
250201ts1100OPUDouble
260401ts1100PreAmpDouble
261001ts1100PreAmp
270001ts1100AttenuatorDouble
540001ts1100UnivAggDGbE
540002ts1100UnivAggDFC
540003ts1100UnivAggDGbE2
550000ts1100UnivAgg
580000ts1100UnivAgg4xGbE
581000ts1100UnivAgg2xGbE2xSTM
590000ts1100Muxponder10G
600100ts1100Nmb
600300ts1100Nmb6003
740001ts1100Tp2x4GFC
750000ts1100Conv1250Cwdm
760000ts1100Conv2500Cwdm
770000ts1100Tp2500Cwdm1
772000ts1100Tp2x2500Cwdm1
790000ts1100Tp10G
791000ts1100Tp10G7910
802001ts1100DuplexerDouble
803000ts1100MuxDemux4chPizza
803100ts1100MuxDemux4chExtPizza
803200ts1100MuxDemux8chPizza
803300ts1100MuxDemux8chExtPizza
812001ts1100Duplexer
813001ts1100MuxDemux4ch1t4
813101ts1100MuxDemux4p1ch1t4
813200ts1100MuxDemux8ch
813300ts1100MuxDemux8p1ch
813400ts1100MuxDemux8ch2
814001ts1100MuxDemux4ch5t8
814101ts1100MuxDemux4p1ch5t8
823000ts1100MuxDemux4chBidir
850100ts1100AddDropDouble
870101ts1100AddDrop
870102ts1100AddDropSingle
883001ts1100DWDMMuxDemuxExt
883101ts1100DWDMMuxDemux
900000ts1100Power9000Supply
904800ts1100Power9048Supply
912200ts1100Power9122Supply
914800ts1100Power9148Supply
922000ts1100Power9220Supply
5800002ts1100UnivAgg2xDGbE
5800003ts1100UnivAgg3xGbERep
5800004ts1100UnivAgg3x25GRep
5810002ts1100UnivAgg4xGbE2
5810003ts1100UnivAgg3xGbERep2
5900002ts1100Muxponder10G2
7910002ts1100Tp10G7910Rep
9200201tm206Fan
9221001tm206OSC1
9221002tm206OSC2
9500101tm206TAM4xesc
9510101tm206TAMln4xesc
9510201tm206TAMln4xetr
9510301tm206TAMlnFlex
9510401tm206TAMln2xfc
9510501tm206TAMlnp2xfc
9600201tm206Cu
9600202tm206Cu2
9780001tm206tp2x4gfc
9813001tm206MuxDemux4ch1t4
9813101tm206MuxDemux4p1ch1t4
9814001tm206MuxDemux4ch5t8
9814101tm206MuxDemux4p1ch5t8
9823001tm206MuxDemux4chBidir1
9823002tm206MuxDemux4chBidir2
9870101tm206AddDrop
.1.3.6.1.4.1.8708.2.11.2.3.1.1.3
equipmentBoardActualType
The actual board type. If an unexpected board
has been detected this variable can be used to
see what type of board has been detected.
EquipmentBoardType
Textual Convention: EquipmentBoardType Enumeration
Type Values:
0undefined
1cu
2tpMr2500
3oxc8
4oxc16
5ocu2
6mxp028
7ad1AB
8ad1BA
9ad2AB
10ad2BA
11ad4AB
12ad4BA
13tpDGbE
14oa
15mdu8Ext
16mdu8Term
17ocu4
18mxp004
19ad2oaAB
20ad2oaBA
21oa2
22adcwdm
23ad1spr
24tp10G
25tpLMr2500
26cu1osc
27cu2osc
28obu
29sync2Mhz
30mxp8
31mxp16
32tpDGbED
33tpDGbEC
34tpDFcD
35tpDFcC
36tpFcGbED
37tpFcGbEC
38tpTFcD
39tpQMr
40mdu4TermAB
41mdu4TermBA
42ad1cwdm
43ad2cwdm
44tp10GLAN
45tp10GRC
46escon8
47oa1x15dBm
48oa2x15dBm
49gxp2500
50gxp2500Sfp
51gxp10G
52tpDGbEDv2
53tpDGbESfp
54tpDFcDv2
55tpDFcSfp
56ad2x1cwdm
57ad2x2cwdm
58mdu8Term2
59tpDDGbE
60fpuOas2824
61mu2F8C
62du2F8C
63tpD10GL
64tpDDGbER
65tp10GBu
66tp10GLANBu
67tp10GClBu
68tp10GLANClBu
69mdu8EvenExt
70mdu8EvenTerm
71oapre1x17dBm
72oa2x17dBm
73oiuc100200
74oapow1x17dBm
75oa1x17dBm
76gbe9Mxp10G
77ad1dwdm2F
78ad1cwdm2F
79mdu4Ext2F
80mdu4Term2F
81voa8ch
82oa1x20dBm
83oa2x20dBm
84fpuYm235
85ad4dwdm2F
86tpQMri
87oar450c
88cuSfp
89tpMr25v2
90tpD10GbE
91tpD10GbER
92mdu4ExtAB
93mdu4ExtBA
94oiuc50100
95mROADM1P800
96edu6pGbE
97tp10GClTc
98mxp4x2G5
99oa1xLG20dBm
100oa2xLG20dBm
101oa1xFG10dBm
102oa2xFG10dBm
103tp10GOtnTc
104mdu40Even
105mdu40Odd
106mdu8Ee
107mdu8Eo
108ocm2p
109msMxp
110voa8chii
111msMxpR
112msMxpDQgbe
113tp10GTcEr
114gbe10Emxp10G
115edu12pGbE
116gbeMxp10GFEC
117roadm1x4G100
118dQgbeMxpR
119tpQMS
120tpQMSR
121gbe22Emxp10G
122oa1x26dBm
123pcu2p
124mxp4x2G5Oc
125voa2ch
126msMxp10GTCEr
127msMxp10G
128msMxpQMS2G5
129gbe22Emxp10Gii
130bsu1x5Even
131bsu1x5Odd
132gbe10Emxp10Gii
133mba1
134mba1SonetDeprecated
135mba2
136mba2SonetDeprecated
137mxpmbh1Sdh
138mxpmbh1Sonet
139roadm1x8G50
140ad4Even50
141ad4Odd50
142emxp80Gii
143msMxpQMS2G5R
144mxp8iiSdh
145mxp8iiSonet
146mba2E
147mba2ptpSdh
148mba2ptpSonet
149mba2EptpSdh
150mba2EptpSonet
151mdu40EvenL
152mdu40OddL
153oa1x20dBmVg
154oa2x20dBmVg
155roadm1x2G100
156roadm1x2G50
157tpq10Gfec
158cuSfpii
159coD40ev
160coD40eve
161coD40od
162coD40ode
163dcDk652km20
164dcDk652km40
165dcDk652km60
166dcDk652km80
167dcP652km40
168dcP652km60
169dcP652km80
170dcP652km100
171dcP652km120
172emxp40Gii
173tpqmp
174tpq10GfecReg
175mdu16cl50g
176voa8chsfp
177msTp40G
178msMxp40G
179mxp10gotn
180emxp62iie
181emxp120iie
182ocudq
183tm4700
184tm4011
185tm100mxp
186tm100tp
187tm100reg
188ocuseed2p
189oa2x21seed
190oypatchcord
191tpq10gfeci
192tpq10gfecregi
193tphex10gotn
194emxp48iie
195tp100gotn
196emxp220iie
197tpmrHL16G
198fhmxp10g
199mxp100gotn
200cuSfpiii
201emxp240iie
202tpmrHL16GUni
203fpu1
204oaraed21hghyb
205oaraed21hgind
206emxp3
207dcDk652km100
208dcDk652km120
209dcP652km20
210fhau1
211fha1u1
212oa1x20dBmVg2
213oa2x20dBmVg2
214ptio10g
215fxp400gotn
216compo24
217rfu1
218coD919926
219coD927934
220coD935942
221coD943950
222oD951958
223coD919926e
224coD927934e
225coD935942e
226coD943950e
227coD951958e
228co4
229co5
230codsf20eva
231codsf20evb
232codsf4919
233codsf4926
234codsf4927
235codsf4934
236codsf4935
237codsf4942
238codsf4943
239codsf4950
240codsf4951
241codsf4958
242codsf2919
243codsf2922
244codsf2923
245codsf2926
246codsf2927
247codsf2930
248codsf2931
249codsf2934
250codsf2935
251codsf2938
252codsf2939
253codsf2942
254codsf2943
255codsf2946
256codsf2947
257codsf2950
258codsf2951
259codsf2954
260codsf2955
261codsf2958
262tp100gotnii
263roadm1x4f
264ptio100g
265oadm2ch
266emxp1u
267emxp1us
268mxp200gotn
269emxp440
270oaraed20lghyb
271roadm1x9f
272ocm8p
273ad1c2fotdr
274hdea1600
275oa1xLG20dBmb
276oa2xLG20dBmb
277oa1x20dBmVgb
278oa2x20dBmVgb
279codsf24mpo10104
280otdr8p
281coD48ev
282coD48od
1001tgCo4
1005tgCo5
1006tgCo6
1007tgCo7
1008tgCo8
1009tgCo9
1010tgCo10
1011tgCo11
1012tgCo12
1014tgCo14
1015tgCo15
1016tgCo16
1040tgCoDxxxyyy
1041tgCoD40ev
1042tgCoD40eve
1043tgCoD40od
1044tgCoD40ode
1050tgCoBSU1x5ev
1051tgCoBSU1x5od
1055tgCad86XX04
1056tgCad86XX02
1057tgCoDSF2ch9XXAB
1058tgCoDSF4ch9XXAB
1059tgCoDSF2ch9XXBA
1060tgCoDSF4ch9XXBA
1061tgTcosf2x1b
1062tgTcosf2x1d
1070tgCoD4XXX
1080tgCoDSF20
1081tgCoDSF20evA
1082tgCoDSF20evB
1083tgCoDSF20odA
1084tgCoDSF20odB
1085tgCoSFBSU1x5ev
2012tgTco12
2014tgTco14
10000acd2pGbE
10001acd5pGbE
10002acd10G
10003edu5GT
10004edu10GLT
10005edu10GLTS
20000nidGE
20001nidSfp155
20002nidSfp622
20003nidSfpVc12
20004nidSfp2488
220401ts1100EthMux4p
250101ts1100OPU
250201ts1100OPUDouble
260401ts1100PreAmpDouble
261001ts1100PreAmp
270001ts1100AttenuatorDouble
540001ts1100UnivAggDGbE
540002ts1100UnivAggDFC
540003ts1100UnivAggDGbE2
550000ts1100UnivAgg
580000ts1100UnivAgg4xGbE
581000ts1100UnivAgg2xGbE2xSTM
590000ts1100Muxponder10G
600100ts1100Nmb
600300ts1100Nmb6003
740001ts1100Tp2x4GFC
750000ts1100Conv1250Cwdm
760000ts1100Conv2500Cwdm
770000ts1100Tp2500Cwdm1
772000ts1100Tp2x2500Cwdm1
790000ts1100Tp10G
791000ts1100Tp10G7910
802001ts1100DuplexerDouble
803000ts1100MuxDemux4chPizza
803100ts1100MuxDemux4chExtPizza
803200ts1100MuxDemux8chPizza
803300ts1100MuxDemux8chExtPizza
812001ts1100Duplexer
813001ts1100MuxDemux4ch1t4
813101ts1100MuxDemux4p1ch1t4
813200ts1100MuxDemux8ch
813300ts1100MuxDemux8p1ch
813400ts1100MuxDemux8ch2
814001ts1100MuxDemux4ch5t8
814101ts1100MuxDemux4p1ch5t8
823000ts1100MuxDemux4chBidir
850100ts1100AddDropDouble
870101ts1100AddDrop
870102ts1100AddDropSingle
883001ts1100DWDMMuxDemuxExt
883101ts1100DWDMMuxDemux
900000ts1100Power9000Supply
904800ts1100Power9048Supply
912200ts1100Power9122Supply
914800ts1100Power9148Supply
922000ts1100Power9220Supply
5800002ts1100UnivAgg2xDGbE
5800003ts1100UnivAgg3xGbERep
5800004ts1100UnivAgg3x25GRep
5810002ts1100UnivAgg4xGbE2
5810003ts1100UnivAgg3xGbERep2
5900002ts1100Muxponder10G2
7910002ts1100Tp10G7910Rep
9200201tm206Fan
9221001tm206OSC1
9221002tm206OSC2
9500101tm206TAM4xesc
9510101tm206TAMln4xesc
9510201tm206TAMln4xetr
9510301tm206TAMlnFlex
9510401tm206TAMln2xfc
9510501tm206TAMlnp2xfc
9600201tm206Cu
9600202tm206Cu2
9780001tm206tp2x4gfc
9813001tm206MuxDemux4ch1t4
9813101tm206MuxDemux4p1ch1t4
9814001tm206MuxDemux4ch5t8
9814101tm206MuxDemux4p1ch5t8
9823001tm206MuxDemux4chBidir1
9823002tm206MuxDemux4chBidir2
9870101tm206AddDrop
.1.3.6.1.4.1.8708.2.11.2.3.1.1.4
equipmentBoardDescr
User configurable label.
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.3.1.1.5
equipmentBoardSubrack
The number of the subrack where the board is
located.
LUM-TCSubrackNumberr/w
Textual Convention: LUM-TCSubrackNumber Unsigned32
Type Constraints:
range: 0..15
.1.3.6.1.4.1.8708.2.11.2.3.1.1.6
equipmentBoardSlot
The slot where the board is located.
LUM-TCSlotNumberr/w
Textual Convention: LUM-TCSlotNumber Unsigned32
Type Constraints:
range: 0..22
.1.3.6.1.4.1.8708.2.11.2.3.1.1.7
equipmentBoardTemp
The temperature on the board in 0.1 degrees
centigrade.
Integer32
Constraints:
range: -1000-1000
.1.3.6.1.4.1.8708.2.11.2.3.1.1.8
equipmentBoardInvPhysIndexOrZero
The row in the invPhysTable for this board.
Set to 0 if not known.
Unsigned32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.8708.2.11.2.3.1.1.9
equipmentBoardLedTest
LED test for the board.

off - Normal operation.

on - Light all leds.
Enumerationr/w
Enumerated Values:
1off
2on
.1.3.6.1.4.1.8708.2.11.2.3.1.1.10
equipmentBoardAdminStatus
The administrative state of the board.

down - The board should be inactive.
Alarms are suppressed.

service - The board is activated but alarms are
suppressed. Intended for use during servic…
LUM-TCBoardOrInterfaceAdminStatusr/w
Textual Convention: LUM-TCBoardOrInterfaceAdminStatus Enumeration
Type Values:
1down
2service
3up
.1.3.6.1.4.1.8708.2.11.2.3.1.1.11
equipmentBoardOperStatus
The operational state of the board.

notPresent - The board is not available.

down - The board remains in the 'down'-state
when adminStatus is set to 'down' or if there is
a fault preventing…
LUM-TCBoardOrInterfaceOperStatus
Textual Convention: LUM-TCBoardOrInterfaceOperStatus Enumeration
Type Values:
1notPresent
2down
3up
.1.3.6.1.4.1.8708.2.11.2.3.1.1.12
equipmentBoardLastChangeTime
The time when the operational state of the
board entry was last changed.
SNMPv2-TCDateAndTime
Textual Convention: SNMPv2-TCDateAndTime OctetString
Type Constraints:
range: 8
range: 11
.1.3.6.1.4.1.8708.2.11.2.3.1.1.13
equipmentBoardRowStatus
SNMP administrivia.
Manages creation and deletion of conceptual rows.
See also SNMPv2-TC.
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.8708.2.11.2.3.1.1.14
equipmentBoardMissing
There is no board present in a slot where the
expected board type is defined. Suppressed if
administrative status is down.

A(ctivation): Card out of place (COP) indication
active for more than 2 seconds.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.15
equipmentBoardUnexpectedType
A type of board not matching the expected type
is present and active in the same slot.
Since the default value for the type is
'undefined' this alarm is raised when inserting
an unconfigured board.

A: A b…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.16
equipmentBoardTempHighExceeded
The threshold for environmental temperature
on the board is exceeded.

A: The temperature exceeds the associated
threshold.

D: Temperature is 0.5 degrees centigrade
below the associated thre…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.17
equipmentBoardCommunicationFailure
Communication between the control unit and the
the board has failed completely.

A: There is a board present but there has been
no communication established within 20 seconds.

D: Communicati…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.18
equipmentBoardInterworkFailed
Communication between the control unit and the
board has failed due to incompatible software.

A: The control unit and the board have
in-compatible software.

D: The control unit and the boar…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.19
equipmentBoardSecondaryPowerFailed
Secondary DC power (1.8 or 2.5 V) failure.

A: The secondary DC power on the board has
failed.

D: The secondary DC power is present.

Note: If primary power fails a
'communicat…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.20
equipmentBoardVitalDataMissing
Product data vital for the safe operation
of the equipment is missing.

A: Product data missing.

D: Product data present.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.21
equipmentBoardNonVitalDataMissing
Administrative product data is missing.

A: Product data missing.

D: Product data present.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.22
equipmentBoardUnderMaintenance
The board is undergoing maintenance, adminStatus
is set to service.

A: AdminStatus is set to service.

D: AdminStatus is set to another value.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.23
equipmentBoardTempThreshold
The threshold for temperature alarm on the
board in 0.1 degrees centigrade.
Integer32r/w
Constraints:
range: 0-800
.1.3.6.1.4.1.8708.2.11.2.3.1.1.24
equipmentBoardSwVersionMismatch
The version of the board SW does not match
the SW version running och the main CU.

For versions to match, the release number,
e.g. 'r2b', must be the same. The build
number is not required to be the same.…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.25
equipmentBoardObjectProperty
Property mask.
LUM-TCObjectProperty
Textual Convention: LUM-TCObjectProperty Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.8708.2.11.2.3.1.1.26
equipmentBoardTempLow
The low threshold for environmental temperature
on the board is exceeded.

A: The temperature exceeds the associated
low threshold.

D: Temperature is 0.5 degrees centigrade
above the associa…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.27
equipmentBoardTempVeryHigh
The very high threshold for environmental
temperature on the board is exceeded.

A: The temperature exceeds the associated
threshold.

D: Temperature is 0.5 degrees centigrade
below the assoc…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.28
equipmentBoardReconfigure
Applicable for cu, cu2osc, cuSfp, cuSfpii and voa8chii.

Reconfigure cu or cu2osc board to cuSfp.
Reconfigure cu2osc or cuSfp board to cuSfpii.
Reconfigure older CU-board to cuSfpiii.
Reconfigure voa8chii …
LUM-TCCommandString
Textual Convention: LUM-TCCommandString OctetString
.1.3.6.1.4.1.8708.2.11.2.3.1.1.29
equipmentBoardLedStatus
LED status for the board.
This is primarily intended for debugging
Enumeration
Enumerated Values:
1clear
2minor
3major
.1.3.6.1.4.1.8708.2.11.2.3.1.1.30
equipmentBoardModuleInfo
Information (for example firmware and serial number) about the module.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.3.1.1.31
equipmentBoardNewSwActivatedButNotRestarted
A new SW version on the board has been activated,
but the board has not been rebooted. This means that
after the next reboot, a new SW will be active.

For the main CU, this also means that the backup
will…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.32
equipmentBoardLowTemperature
The environmental temperature on the board
is below startuptemperature (+3 centigrade).

A: The temperature is below +3 degrees centigrade.

D: Temperature has increased to +5 degrees centigr…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.33
equipmentBoardTempLowThreshold
The threshold for low temperature alarm on the
board in 0.1 degrees centigrade.
Integer32
Constraints:
range: -400-400
.1.3.6.1.4.1.8708.2.11.2.3.1.1.34
equipmentBoardAdditionalInfo
Additional information about the board,
e.g. FPGA revision.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.3.1.1.35
equipmentBoardBootError
The card fails to boot.

A: The card fails to boot.

D: The card boot successfully.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.36
equipmentBoardHardwareError
A hardware error occured.

A: A hardware error occured.

D: No hardware error.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.37
equipmentBoardLowDiskSpace
Low disk space in the board.

A: Not enough disk space.

D: Disk space is enough.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.38
equipmentBoardClockDrift
Clock frequency is out of range.

A: Clock frequency out is out of range.

D: Clock frequency is in range.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.39
equipmentBoardPostponeFwUpgrade
Postpone activation of new traffic firmware when
the board software is upgraded next time. If no
firmware changes are available when upgrading this
option will not have any effect.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.8708.2.11.2.3.1.1.40
equipmentBoardActivatePendingFwCommand
Command to activate a pending firmware upgrade.
LUM-TCCommandString
Textual Convention: LUM-TCCommandString OctetString
.1.3.6.1.4.1.8708.2.11.2.3.1.1.41
equipmentBoardFwActivationPending
Firmware activation has been postponed in a
previous software upgrade.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.42
equipmentBoardFeatureNotSupported
A configuration request has failed since the chosen
feature is not supported by the active firmware.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.43
equipmentBoardFwReloadNeeded
The traffic HW has been programmed by a version
of the system that does not offer a supported
upgrade path to the currently running version.
This typically happens after a downgrade
or rollback of the SW. The state of t…
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.44
equipmentBoardFwContextUnknown
The running version of the SW cannot recover
the settings of the traffic HW/FW. The state
of the traffic HW is unknown. A reset of the
traffic unit is recommended.
This will cause a short traffic hit.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.45
equipmentBoardBoardVariant
Determines board configuration.

dualMuxponderProt - 2x Muxponder with protection
hexTransponder - 6x Transponder
tripleMuxponderProt - 3x Muxponder with protection
quadTransponderProt - 4x Transpon…
Enumerationr/w
Enumerated Values:
1dualMuxponderProt
2hexTransponder
3tripleMuxponderProt
4quadTransponderProt
2147483647notApplicable
.1.3.6.1.4.1.8708.2.11.2.3.1.1.46
equipmentBoardCabinetConnectivity
Monitor Cabinet status if enabled. Alarm is raised if connection is lost.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.8708.2.11.2.3.1.1.47
equipmentBoardCabinetConnectionFailure
Connection to the cabinet has failed.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.3.1.1.48
equipmentBoardOperationalVariant
Operational Variant mode of board, Normal or OpenFlow Controlled.
Enumerationr/w
Enumerated Values:
1normal
2openFlowControlled
.1.3.6.1.4.1.8708.2.11.2.3.1.1.49
equipmentBoardAid
The access identifier (AID) of the product.
The format is according to GR-833.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.3.1.1.50
equipmentBoardPhysicalLocation
The Physical location of the product.
The format is according to GR-833.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.3.1.1.51
.1.3.6.1.4.1.8708.2.11.2.4.1 · 1 row entry · 17 columns
The list of power supplies.
equipmentPowerEntry entry .1.3.6.1.4.1.8708.2.11.2.4.1.1
An entry in the power supply list.
Indexes
equipmentPowerIndex
Column Syntax OID
equipmentPowerIndex
An arbitrary index assigned to each power module.
Unsigned32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.8708.2.11.2.4.1.1.1
equipmentPowerName
The name of the power module.
For example 'pow:1:2'.
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.8708.2.11.2.4.1.1.2
equipmentPowerSubrack
The number of the subrack in which the power
module is present.
LUM-TCSubrackNumber
Textual Convention: LUM-TCSubrackNumber Unsigned32
Type Constraints:
range: 0..15
.1.3.6.1.4.1.8708.2.11.2.4.1.1.3
equipmentPowerSlot
The number of the slot in which the power
module is present.
Unsigned32
Constraints:
range: 1-2
.1.3.6.1.4.1.8708.2.11.2.4.1.1.4
equipmentPowerType
The the type of power module.

ac - AC power supply (230V).

dc - DC power supply (48V).
Enumeration
Enumerated Values:
0undefined
1ac
2dc
.1.3.6.1.4.1.8708.2.11.2.4.1.1.5
equipmentPowerInvPhysIndexOrZero
The row in the invPhysTable for this power
module. Set to 0 if not known.
Unsigned32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.8708.2.11.2.4.1.1.9
equipmentPowerAdminStatus
The administrative state of the power module.

down - This power module is not monitored.
Suppresses alarms.

up - The power module is monitored.
Enumerationr/w
Enumerated Values:
1down
2up
.1.3.6.1.4.1.8708.2.11.2.4.1.1.10
equipmentPowerOperStatus
The operational state of the power module.

notPresent - The power module is not present.

down - The module is not active or there are
faults preventing it from going to the
'up'-state.
Enumeration
Enumerated Values:
1notPresent
2down
3up
.1.3.6.1.4.1.8708.2.11.2.4.1.1.11
equipmentPowerRowStatus
Manages creation and deletion of conceptual rows.
See also SNMPv2-TC.
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.8708.2.11.2.4.1.1.12
equipmentPowerACPowerFailed
AC power supply failed (230 V).

A(ctivation): Active HW indication.

D(e-activation): Inactive HW indication.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.4.1.1.13
equipmentPowerDCPowerFailed
DC power supply failed (48 V).

A: Active HW indication.

D: Inactive HW indication.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.4.1.1.14
equipmentPowerTemperatureHigh
The built-in temperature monitoring of the power
module thinks it is too hot.

A: Active HW indication.

D: Inactive HW indication.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.4.1.1.15
equipmentPowerModuleMissing
The power module is not available.

A: Active HW indication.

D: Inactive HW indication.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.4.1.1.16
equipmentPowerObjectProperty
Property mask.
LUM-TCObjectProperty
Textual Convention: LUM-TCObjectProperty Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.8708.2.11.2.4.1.1.17
equipmentPowerDCPowerFailedSeverity
The severity of DC Power failed alarm.
LUM-ALARM-MIBAlarmPerceivedSeverityr/w
Textual Convention: LUM-ALARM-MIBAlarmPerceivedSeverity Enumeration
Type Values:
0undefined
1cleared
2indeterminate
3warning
4minor
5major
6critical
.1.3.6.1.4.1.8708.2.11.2.4.1.1.18
equipmentPowerAid
The access identifier (AID) of the product.
The format is according to GR-833.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.4.1.1.19
equipmentPowerPhysicalLocation
The Physical location of the product.
The format is according to GR-833.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.4.1.1.20
.1.3.6.1.4.1.8708.2.11.2.5.1 · 1 row entry · 14 columns
The list of fan modules.
equipmentFanEntry entry .1.3.6.1.4.1.8708.2.11.2.5.1.1
An entry in the fan module list.
Indexes
equipmentFanIndex
Column Syntax OID
equipmentFanIndex
An arbitrary index assigned to each fan module.
Unsigned32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.8708.2.11.2.5.1.1.1
equipmentFanName
The name of the fan module.
For example 'fan:1:2', where the first number
indicates the subrack and the second number the
fan slot.
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.8708.2.11.2.5.1.1.2
equipmentFanSubrack
The number of the subrack in which the fan
module is present.
LUM-TCSubrackNumber
Textual Convention: LUM-TCSubrackNumber Unsigned32
Type Constraints:
range: 0..15
.1.3.6.1.4.1.8708.2.11.2.5.1.1.3
equipmentFanSlot
The number of the fan-slot in which the fan
module is present.
Unsigned32
Constraints:
range: 1-3
.1.3.6.1.4.1.8708.2.11.2.5.1.1.4
equipmentFanInvPhysIndexOrZero
The row in the invPhysTable for this fan module.
Set to 0 if not known.
Unsigned32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.8708.2.11.2.5.1.1.5
equipmentFanAdminStatus
The administrative state of the fan module.

down - This fan module should not be monitored.
Suppresses alarms. Useful if a subrack has only
one fan for some reason.

up - The fan module shou…
Enumerationr/w
Enumerated Values:
1down
2up
.1.3.6.1.4.1.8708.2.11.2.5.1.1.6
equipmentFanOperStatus
The operational state of the fan module.

Note: It is not possible to distinguish between
a missing fan and a failed fan. Therefore
'notPresent' is currently not used.

down - The fan module …
Enumeration
Enumerated Values:
1notPresent
2down
3up
.1.3.6.1.4.1.8708.2.11.2.5.1.1.7
equipmentFanRowStatus
Manages creation and deletion of conceptual rows.
See also SNMPv2-TC.
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.8708.2.11.2.5.1.1.8
equipmentFanUnitFailed
The fan module has failed or is absent.

A(ctivation): Active HW indication.

D(e-activation): Inactive HW indication.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.5.1.1.9
equipmentFanMainUnitFailed
The main fan module has failed or is absent.

A(ctivation): Active HW indication.

D(e-activation): Inactive HW indication.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.5.1.1.10
equipmentFanObjectProperty
Property mask.
LUM-TCObjectProperty
Textual Convention: LUM-TCObjectProperty Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.8708.2.11.2.5.1.1.11
equipmentFanFanFault
The Fan malfunction or fan speed differs from the set speed.

A(ctivation): Active HW indication.

D(e-activation): Inactive HW indication.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.5.1.1.12
equipmentFanAid
The access identifier (AID) of the product.
The format is according to GR-833.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.5.1.1.13
equipmentFanPhysicalLocation
The Physical location of the product.
The format is according to GR-833.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.5.1.1.14
.1.3.6.1.4.1.8708.2.11.2.9.1 · 1 row entry · 10 columns
The slot list.
equipmentSlotEntry entry .1.3.6.1.4.1.8708.2.11.2.9.1.1
An entry in the slot list.
One entry for each slot.
Indexes
equipmentSlotIndex
Column Syntax OID
equipmentSlotIndex
An arbitrary index assigned to each
slot entry.
Unsigned32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.8708.2.11.2.9.1.1.1
equipmentSlotName
The name of the slot, for example 'tpmr2500:1:2'
where the first number indicates in which sub-rack
the slot is present and the second number
in which slot.
LUM-TCMgmtNameString
Textual Convention: LUM-TCMgmtNameString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.9.1.1.2
equipmentSlotSubrack
The number of the subrack in which the slot
is present.
LUM-TCSubrackNumber
Textual Convention: LUM-TCSubrackNumber Unsigned32
Type Constraints:
range: 0..15
.1.3.6.1.4.1.8708.2.11.2.9.1.1.3
equipmentSlotSlot
The slot number.
LUM-TCSlotNumber
Textual Convention: LUM-TCSlotNumber Unsigned32
Type Constraints:
range: 0..22
.1.3.6.1.4.1.8708.2.11.2.9.1.1.4
equipmentSlotAdminStatus
The administrative state of the slot.

down - The slot is not monitored.

up - The interface should be activated.
LUM-TCAdminStatusr/w
Textual Convention: LUM-TCAdminStatus Enumeration
Type Values:
1down
2up
.1.3.6.1.4.1.8708.2.11.2.9.1.1.5
equipmentSlotUsageState
Tells if the slot is used or not.

used - Slot is used.

notUsed - Slot is not used.
Enumeration
Enumerated Values:
1notUsed
2used
.1.3.6.1.4.1.8708.2.11.2.9.1.1.6
equipmentSlotEmptySlot
Slot is empty, alarm only applicable for systems with mendatory slot usage

A: Slot is empty.

D: No empty slot.
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.9.1.1.7
equipmentSlotEquipped
Is the entity equipped.
LUM-TCTruthValueWithNA
Textual Convention: LUM-TCTruthValueWithNA Enumeration
Type Values:
0true
1false
2147483646notAvailable
2147483647notApplicable
.1.3.6.1.4.1.8708.2.11.2.9.1.1.8
equipmentSlotAid
The access identifier (AID) of the slot.
The format is according to GR-833.
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.8708.2.11.2.9.1.1.9
equipmentSlotPhysicalLocation
The physical location of the slot.
The format is according to GR-833.
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.8708.2.11.2.9.1.1.10
.1.3.6.1.4.1.8708.2.11.2.10.1 · 1 row entry · 10 columns
The module list.
equipmentOpticalModuleEntry entry .1.3.6.1.4.1.8708.2.11.2.10.1.1
An entry in the module list.
Indexes
equipmentOpticalModuleIndex
Column Syntax OID
equipmentOpticalModuleIndex
An arbitrary index assigned to each entry.
Unsigned32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.8708.2.11.2.10.1.1.1
equipmentOpticalModuleHostBoardType
The actual board type hosting the optical module.
EquipmentBoardType
Textual Convention: EquipmentBoardType Enumeration
Type Values:
0undefined
1cu
2tpMr2500
3oxc8
4oxc16
5ocu2
6mxp028
7ad1AB
8ad1BA
9ad2AB
10ad2BA
11ad4AB
12ad4BA
13tpDGbE
14oa
15mdu8Ext
16mdu8Term
17ocu4
18mxp004
19ad2oaAB
20ad2oaBA
21oa2
22adcwdm
23ad1spr
24tp10G
25tpLMr2500
26cu1osc
27cu2osc
28obu
29sync2Mhz
30mxp8
31mxp16
32tpDGbED
33tpDGbEC
34tpDFcD
35tpDFcC
36tpFcGbED
37tpFcGbEC
38tpTFcD
39tpQMr
40mdu4TermAB
41mdu4TermBA
42ad1cwdm
43ad2cwdm
44tp10GLAN
45tp10GRC
46escon8
47oa1x15dBm
48oa2x15dBm
49gxp2500
50gxp2500Sfp
51gxp10G
52tpDGbEDv2
53tpDGbESfp
54tpDFcDv2
55tpDFcSfp
56ad2x1cwdm
57ad2x2cwdm
58mdu8Term2
59tpDDGbE
60fpuOas2824
61mu2F8C
62du2F8C
63tpD10GL
64tpDDGbER
65tp10GBu
66tp10GLANBu
67tp10GClBu
68tp10GLANClBu
69mdu8EvenExt
70mdu8EvenTerm
71oapre1x17dBm
72oa2x17dBm
73oiuc100200
74oapow1x17dBm
75oa1x17dBm
76gbe9Mxp10G
77ad1dwdm2F
78ad1cwdm2F
79mdu4Ext2F
80mdu4Term2F
81voa8ch
82oa1x20dBm
83oa2x20dBm
84fpuYm235
85ad4dwdm2F
86tpQMri
87oar450c
88cuSfp
89tpMr25v2
90tpD10GbE
91tpD10GbER
92mdu4ExtAB
93mdu4ExtBA
94oiuc50100
95mROADM1P800
96edu6pGbE
97tp10GClTc
98mxp4x2G5
99oa1xLG20dBm
100oa2xLG20dBm
101oa1xFG10dBm
102oa2xFG10dBm
103tp10GOtnTc
104mdu40Even
105mdu40Odd
106mdu8Ee
107mdu8Eo
108ocm2p
109msMxp
110voa8chii
111msMxpR
112msMxpDQgbe
113tp10GTcEr
114gbe10Emxp10G
115edu12pGbE
116gbeMxp10GFEC
117roadm1x4G100
118dQgbeMxpR
119tpQMS
120tpQMSR
121gbe22Emxp10G
122oa1x26dBm
123pcu2p
124mxp4x2G5Oc
125voa2ch
126msMxp10GTCEr
127msMxp10G
128msMxpQMS2G5
129gbe22Emxp10Gii
130bsu1x5Even
131bsu1x5Odd
132gbe10Emxp10Gii
133mba1
134mba1SonetDeprecated
135mba2
136mba2SonetDeprecated
137mxpmbh1Sdh
138mxpmbh1Sonet
139roadm1x8G50
140ad4Even50
141ad4Odd50
142emxp80Gii
143msMxpQMS2G5R
144mxp8iiSdh
145mxp8iiSonet
146mba2E
147mba2ptpSdh
148mba2ptpSonet
149mba2EptpSdh
150mba2EptpSonet
151mdu40EvenL
152mdu40OddL
153oa1x20dBmVg
154oa2x20dBmVg
155roadm1x2G100
156roadm1x2G50
157tpq10Gfec
158cuSfpii
159coD40ev
160coD40eve
161coD40od
162coD40ode
163dcDk652km20
164dcDk652km40
165dcDk652km60
166dcDk652km80
167dcP652km40
168dcP652km60
169dcP652km80
170dcP652km100
171dcP652km120
172emxp40Gii
173tpqmp
174tpq10GfecReg
175mdu16cl50g
176voa8chsfp
177msTp40G
178msMxp40G
179mxp10gotn
180emxp62iie
181emxp120iie
182ocudq
183tm4700
184tm4011
185tm100mxp
186tm100tp
187tm100reg
188ocuseed2p
189oa2x21seed
190oypatchcord
191tpq10gfeci
192tpq10gfecregi
193tphex10gotn
194emxp48iie
195tp100gotn
196emxp220iie
197tpmrHL16G
198fhmxp10g
199mxp100gotn
200cuSfpiii
201emxp240iie
202tpmrHL16GUni
203fpu1
204oaraed21hghyb
205oaraed21hgind
206emxp3
207dcDk652km100
208dcDk652km120
209dcP652km20
210fhau1
211fha1u1
212oa1x20dBmVg2
213oa2x20dBmVg2
214ptio10g
215fxp400gotn
216compo24
217rfu1
218coD919926
219coD927934
220coD935942
221coD943950
222oD951958
223coD919926e
224coD927934e
225coD935942e
226coD943950e
227coD951958e
228co4
229co5
230codsf20eva
231codsf20evb
232codsf4919
233codsf4926
234codsf4927
235codsf4934
236codsf4935
237codsf4942
238codsf4943
239codsf4950
240codsf4951
241codsf4958
242codsf2919
243codsf2922
244codsf2923
245codsf2926
246codsf2927
247codsf2930
248codsf2931
249codsf2934
250codsf2935
251codsf2938
252codsf2939
253codsf2942
254codsf2943
255codsf2946
256codsf2947
257codsf2950
258codsf2951
259codsf2954
260codsf2955
261codsf2958
262tp100gotnii
263roadm1x4f
264ptio100g
265oadm2ch
266emxp1u
267emxp1us
268mxp200gotn
269emxp440
270oaraed20lghyb
271roadm1x9f
272ocm8p
273ad1c2fotdr
274hdea1600
275oa1xLG20dBmb
276oa2xLG20dBmb
277oa1x20dBmVgb
278oa2x20dBmVgb
279codsf24mpo10104
280otdr8p
281coD48ev
282coD48od
1001tgCo4
1005tgCo5
1006tgCo6
1007tgCo7
1008tgCo8
1009tgCo9
1010tgCo10
1011tgCo11
1012tgCo12
1014tgCo14
1015tgCo15
1016tgCo16
1040tgCoDxxxyyy
1041tgCoD40ev
1042tgCoD40eve
1043tgCoD40od
1044tgCoD40ode
1050tgCoBSU1x5ev
1051tgCoBSU1x5od
1055tgCad86XX04
1056tgCad86XX02
1057tgCoDSF2ch9XXAB
1058tgCoDSF4ch9XXAB
1059tgCoDSF2ch9XXBA
1060tgCoDSF4ch9XXBA
1061tgTcosf2x1b
1062tgTcosf2x1d
1070tgCoD4XXX
1080tgCoDSF20
1081tgCoDSF20evA
1082tgCoDSF20evB
1083tgCoDSF20odA
1084tgCoDSF20odB
1085tgCoSFBSU1x5ev
2012tgTco12
2014tgTco14
10000acd2pGbE
10001acd5pGbE
10002acd10G
10003edu5GT
10004edu10GLT
10005edu10GLTS
20000nidGE
20001nidSfp155
20002nidSfp622
20003nidSfpVc12
20004nidSfp2488
220401ts1100EthMux4p
250101ts1100OPU
250201ts1100OPUDouble
260401ts1100PreAmpDouble
261001ts1100PreAmp
270001ts1100AttenuatorDouble
540001ts1100UnivAggDGbE
540002ts1100UnivAggDFC
540003ts1100UnivAggDGbE2
550000ts1100UnivAgg
580000ts1100UnivAgg4xGbE
581000ts1100UnivAgg2xGbE2xSTM
590000ts1100Muxponder10G
600100ts1100Nmb
600300ts1100Nmb6003
740001ts1100Tp2x4GFC
750000ts1100Conv1250Cwdm
760000ts1100Conv2500Cwdm
770000ts1100Tp2500Cwdm1
772000ts1100Tp2x2500Cwdm1
790000ts1100Tp10G
791000ts1100Tp10G7910
802001ts1100DuplexerDouble
803000ts1100MuxDemux4chPizza
803100ts1100MuxDemux4chExtPizza
803200ts1100MuxDemux8chPizza
803300ts1100MuxDemux8chExtPizza
812001ts1100Duplexer
813001ts1100MuxDemux4ch1t4
813101ts1100MuxDemux4p1ch1t4
813200ts1100MuxDemux8ch
813300ts1100MuxDemux8p1ch
813400ts1100MuxDemux8ch2
814001ts1100MuxDemux4ch5t8
814101ts1100MuxDemux4p1ch5t8
823000ts1100MuxDemux4chBidir
850100ts1100AddDropDouble
870101ts1100AddDrop
870102ts1100AddDropSingle
883001ts1100DWDMMuxDemuxExt
883101ts1100DWDMMuxDemux
900000ts1100Power9000Supply
904800ts1100Power9048Supply
912200ts1100Power9122Supply
914800ts1100Power9148Supply
922000ts1100Power9220Supply
5800002ts1100UnivAgg2xDGbE
5800003ts1100UnivAgg3xGbERep
5800004ts1100UnivAgg3x25GRep
5810002ts1100UnivAgg4xGbE2
5810003ts1100UnivAgg3xGbERep2
5900002ts1100Muxponder10G2
7910002ts1100Tp10G7910Rep
9200201tm206Fan
9221001tm206OSC1
9221002tm206OSC2
9500101tm206TAM4xesc
9510101tm206TAMln4xesc
9510201tm206TAMln4xetr
9510301tm206TAMlnFlex
9510401tm206TAMln2xfc
9510501tm206TAMlnp2xfc
9600201tm206Cu
9600202tm206Cu2
9780001tm206tp2x4gfc
9813001tm206MuxDemux4ch1t4
9813101tm206MuxDemux4p1ch1t4
9814001tm206MuxDemux4ch5t8
9814101tm206MuxDemux4p1ch5t8
9823001tm206MuxDemux4chBidir1
9823002tm206MuxDemux4chBidir2
9870101tm206AddDrop
.1.3.6.1.4.1.8708.2.11.2.10.1.1.2
equipmentOpticalModuleType
The type of optical module,
for example monitor, switch, wss, amp etc
LUM-TCMgmtNameString
Textual Convention: LUM-TCMgmtNameString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.10.1.1.3
equipmentOpticalModuleName
The management name of the interface,
for example 'module:[HostBoardType]:[ moduleType]:[subrack]:[slot]'.
LUM-TCMgmtNameString
Textual Convention: LUM-TCMgmtNameString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.10.1.1.4
equipmentOpticalModuleSubrack
The number of the subrack where the module
is located.
LUM-TCSubrackNumber
Textual Convention: LUM-TCSubrackNumber Unsigned32
Type Constraints:
range: 0..15
.1.3.6.1.4.1.8708.2.11.2.10.1.1.5
equipmentOpticalModuleSlot
The number of the slot where the module is
located.
LUM-TCSlotNumber
Textual Convention: LUM-TCSlotNumber Unsigned32
Type Constraints:
range: 0..22
.1.3.6.1.4.1.8708.2.11.2.10.1.1.6
equipmentOpticalModuleFirmwareVersion
Firmware version of the module.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.10.1.1.7
equipmentOpticalModuleSerialNumber
Serial number of the module.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.8708.2.11.2.10.1.1.8
equipmentOpticalModuleWarmingUpState
Module is warming up, the optics has not reached a stable
state.

True: Module is warming up.

False: Module is ready and optics have reached stable state.
LUM-TCTruthValueWithNA
Textual Convention: LUM-TCTruthValueWithNA Enumeration
Type Values:
0true
1false
2147483646notAvailable
2147483647notApplicable
.1.3.6.1.4.1.8708.2.11.2.10.1.1.9
equipmentOpticalModuleFailure
The module is experiencing a failure.

A(ctivation): The module has failed

D(e-activation): The module is OK again
LUM-TCFaultStatus
Textual Convention: LUM-TCFaultStatus Enumeration
Type Values:
1ok
2alarm
.1.3.6.1.4.1.8708.2.11.2.10.1.1.10