CTRON-WAN-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
16
Rows
16
Columns
216

wanConnTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.7.1.1.2 · 1 row entry · 4 columns
A list of wan connection entries. The number of wan
connection entries is given by the value of wanNumConnections.
wanConnEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.1.2.1
A wan connection entry containing objects relating to
the particular wan connection.
Indexes
wanConnIndex
Column Syntax OID
wanConnIndex mandatory
A unique value for each wan connection. Its value ranges
between 1 and the value wanNumConnections.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.1.2.1.1
wanConnNumPhysPorts mandatory
The number of physical ports that exist on this wan
connection.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.1.2.1.2
wanConnDefaultPhysPort mandatory
The default physical port for this connection. This
indicates the physical port that should be used on this wan
connection. If redundancy is not enabled, this physical port
will always be used. If redundancy is enabled…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.1.2.1.3
wanConnActivePhysPort mandatory
The physical port that is currently active for this wan
connection. The value of this object indicates the
wanPhysPortIndex for the active port.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.1.2.1.4

wanPhysPortTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.7.1.1.3 · 1 row entry · 4 columns
A list of the descriptions of the physical ports of this
platform. The number of entries is given by the value
of wanConnNumPhysPort for each Wan Connection.
wanPhysPortEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.1.3.1
A physical port entry. It contains objects relating to a
given physical port
Indexes
wanPhysPortConnectionIndex wanPhysPortIndex
Column Syntax OID
wanPhysPortConnectionIndex mandatory
A value indicating the wan connection this physical port
is located on.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.1.3.1.1
wanPhysPortIndex mandatory
A unique value for each physical port on a wan connection.
Its value ranges between 1 and the value wanConnNumPhysPorts.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.1.3.1.2
wanPhysPortType mandatory
The type of physical port that this entry describes. None
indicates that the physical port has no connector.
Enumeration
Enumerated Values:
1none
2t1
3e1
4synchronous
5dds
6di
7hdsl
8bri
9ds30
10t1DDS
.1.3.6.1.4.1.52.4.1.2.7.1.1.3.1.3
wanPhysPortSpecificMib mandatory
This object identifies an instance of the index object in
the first group of objects in the MIB specific to the
physical port.
ObjectIdentifier .1.3.6.1.4.1.52.4.1.2.7.1.1.3.1.4

wanInterfaceTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.7.1.1.4 · 1 row entry · 14 columns
The interface table for a physical port on a wan connection.
It is a list of items that are pertinent to the interfaces
that are part of this physical port. The number of entries
is dependent on the wanPhysPortType for the interface.
If the wanPhysPortType is none, there will be no entries
in the table for the port. If the wanPhysPortType is t1,
there will be 24 entries in this table for the port.
If the wanPhysPortType is e1, there will be 30 entries
in this table for the port. If the wanPhysPortType is
synchronous, there will be one entry in this table for the
port.
wanInterfaceEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.1.4.1
A wan connection physical port interface entry. It
contains objects relating to an interface that is defined
for this physical port and this wan connection.
Indexes
wanInterfaceConnectionIndex wanInterfacePhysPortIndex wanInterfaceEntryIndex
Column Syntax OID
wanInterfaceConnectionIndex mandatory
This value is the wan connection that this interface
exists on.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.1
wanInterfacePhysPortIndex mandatory
This value is the physical port of the wan connection
that this interface exists on.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.2
wanInterfaceEntryIndex mandatory
A unique value for each interface of this physical port.
It is a value between 1 and the number of interfaces that
exist for the current port. The number of interfaces for
each type of port is: 24 for a port type (wanPh…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.3
wanInterfaceEntryIfIndex mandatory
The ifIndex of the interface. This is the index of this entry
in the ifTable.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.4
wanInterfaceEntryProtocol mandatory
The protocol that should be run on this interface. Values
are equivalent to those defined for ifType in Mib-II.
Accepted values are product dependent.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.5
wanInterfaceEntryCompression mandatory
Indicates whether data compression should take
place on this interface.
Enumerationr/w
Enumerated Values:
1on
2off
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.6
wanInterfaceEntryMTU mandatory
The MTU to be negotiated for this interface. This will not
be updated with the actual MTU, which can be found in the
ifTable.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.7
wanInterfaceEntryLineCoding mandatory
This object describes the variety of Zero Code suppression
on this interface. For an interface on a Ds1 Port, the valid
values depend on the value of the Ds1ConfigLineCode object.
If that object is set to ds1xB8ZS, then…
Enumerationr/w
Enumerated Values:
1none
2jBZS
3invHDLC
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.8
wanInterfaceEntryCrcLength mandatory
The Length of the CRC for this interface. Not all platforms
will allow all options.
Enumerationr/w
Enumerated Values:
1sixteen-bits
2thirty-two-bits
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.9
wanInterfaceEntryLexProtocolEnable obsolete
This switch acts in concert with the wanInterfaceEntryProtocol
object. To activate LEX, this object should first be set to
enable (1), then set the wanInterfaceEntryProtocol to PPP. The
enable will have no effect if …
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.10
wanInterfaceEntryLexProtocolStatus obsolete
This object reflects the current state of the link. The device
is said to be bound to the router when the physical link is OK,
the LEX negotiation is successful, and the router has been
configured correctly to communic…
Enumeration
Enumerated Values:
1bound
2unbound
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.11
wanInterfaceEntryCompRatio mandatory
The ratio of uncompressed to compressed transmitted data.
If the data compression status is off, 1:1 will be displayed
OctetString
Constraints:
range: 6-6
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.12
wanInterfaceEntryCompStatus mandatory
On indicates that the compression has been successfully
negotiated and is operating. Off indicates that the
compression negotiation has failed and compression is not
operating at this time, or compression has been termi…
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.13
wanInterfaceEntryBackUpIfEnable mandatory
This object is used to select the Call-backup option.
A value of 1 is used to enable the option and a value of
2 to disable it.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.14

wanDs1ExtensionsTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.7.1.2.1 · 1 row entry · 18 columns
This table is an extension to the standard ds1 configuration
table. It is a list of items that are pertinent to ds1 ports
on a platform. There is one entry per ds1 physical port on
the platform
wanDs1ExtensionsEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.2.1.1
A ds1 extensions entry containing objects relating to
the particular ds1 physical port
Indexes
wanDs1ExtensionsEntryIndex
Column Syntax OID
wanDs1ExtensionsEntryIndex mandatory
A unique value for each ds1 physical port on the platform.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.1
wanDs1ExtensionsNumInterfaces mandatory
The number of interfaces on this physical port. This
number indicates the number of entries this physical port
uses in the ifTable.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.2
wanDs1ExtensionsToggleFracTable mandatory
Setting this object to 1 will cause the Ds1 Fractional Table
to be updated with the new values, as entered.
Setting this object to 2, will cause the Ds1 Fractional Table
to view as the table being entered.
Setting this …
Enumerationr/w
Enumerated Values:
1update-table
2display-new
3display-old
4restore-old
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.3
wanDs1ExtensionsLineBuildOut mandatory
The line build out setting for this ds1 physical port.
Unknown indicates that the setting is neither readable or
writable.
Enumerationr/w
Enumerated Values:
1unknown
2zero
3minus-7point5
4minus-15
5a133to266feet
6a266to399feet
7a399to533feet
8a533to655feet
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.4
wanDs1ExtensionsCFADuration mandatory
The length of time (in seconds), that the ds1 port will
remain in the Carrier Failure Alarm state after the
alarm condition has cleared.
Integer32r/w
Constraints:
range: 1-15
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.5
wanDs1ExtensionsDIEnable mandatory
Enables or disables Drop and Insert functionality on a
D/I WPIM. If enabled, all zero assigned timeslots will
designate D/I interface channels, if disabled all zero
channels will designate dummy channels as on a T1 o…
Enumerationr/w
Enumerated Values:
1enable
2disable
3diDataEnabled
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.6
wanDs1ExtensionsTotalValidIntervals mandatory
The number of previous intervals for which
valid data was collected for the DS1 mib, which
is currently RFC1406. This counter is similar to
RFC1406 dsx1ValidIntervals except that the count
represents the total numb…
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.7
wanDs1ExtensionsBertTestMode mandatory
This object is used to request that a type of
process be in control of the testing function.
This is used to differentiate between automated test
procedures and those manually controlled by a user.
When read, this ob…
Enumerationr/w
Enumerated Values:
1none
2internal
3manual
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.8
wanDs1ExtensionsBertRun mandatory
Controls the sending of test data over this physical
port. The data is a pattern described by
wanDs1ExtensionsBertTestPattern.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.9
wanDs1ExtensionsBertCurrentResults mandatory
Indicates the results of the testing for the
last completed sampling period. A non-negative
number is the error rate in bits per million bits.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.10
wanDs1ExtensionsBertCumulativeResults mandatory
Indicates the total number of errors since the
testing was enabled. It is not a rate.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.11
wanDs1ExtensionsBertPeakResults mandatory
Indicates the highest value of
wanDs1ExtensionsBertCurrentResults since the testing
was enabled. A non-negative number is the error rate
in bits per million bits.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.12
wanDs1ExtensionsBertAverageResult mandatory
Indicates the average value of
wanDs1ExtensionsBertCurrentResults since the testing
was enabled. A non-negative number is the error rate
in bits per million bits.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.13
wanDs1ExtensionsBertTestPattern mandatory
This object is used to specify the pattern of the
test data.
Enumerationr/w
Enumerated Values:
1patternOther
2pattern1s
3pattern63
4pattern511
5pattern2047
6pattern3in24
7patternQRSS
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.14
wanDs1ExtensionsBertSamplePeriod mandatory
This object is the duration of time in seconds at
which the current test results will be periodically
written to wanDs1ExtensionsBertCurrentResults. The
range is 1 to 3600, with a default value of 10.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.15
wanDs1ExtensionsBertNumPeriods mandatory
The number of sampling periods that have elapsed
during the current test run.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.16
wanDs1ExtensionsBertTestTraps mandatory
This object is used to enable or disable the sending
of a trap at the conclusion of the measurement period.
The trap will contain the information described by
ctDs1BertCurrentResults. The default value is disabled.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.17
wanDs1ExtensionsBertDataStatus mandatory
This object provides the operating status of the
transmission of test data packets.
Enumeration
Enumerated Values:
1idle
2waitingForLink
3waitingForLoopback
4running
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.18
.1.3.6.1.4.1.52.4.1.2.7.1.3.1 · 1 row entry · 3 columns
This table is an extension to the standard rs232-like mib.
It is a list of items that are pertinent to rs232-like ports
on a platform. There is one entry per synchronous physical
port on the platform.
wanRs232ExtensionsEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.3.1.1
A rs232-like extensions entry containing objects relating to
the particular rs232-like physical port.
Indexes
wanRs232ExtensionsEntryIndex
Column Syntax OID
wanRs232ExtensionsEntryIndex mandatory
A unique value for each rs232-like physical port on
the platform.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.3.1.1.1
wanRs232ExtensionsCTSEnable mandatory
This object indicates whether the platform should generate
CTS. When disabled the platform will not generate CTS, when
enabled, the platform will generate CTS. The actual state
of the CTS line is available in the rs-23…
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.52.4.1.2.7.1.3.1.1.2
wanRs232ExtensionsDSREnable mandatory
This object indicates whether the platform should generate
DSR. When disabled the platform will not generate DSR, when
enabled, the platform will generate DSR. The actual state
of the DSR line is available in the rs-23…
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.52.4.1.2.7.1.3.1.1.3

frDcpCircuitTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.7.1.4.1 · 1 row entry · 5 columns
A table containing data compression information about 
specific Data Link Connection Identifiers and corresponding
virtual circuit. This information is used to support the
frCircuitTable following RFC-1315.
frDcpCircuitEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.4.1.1
The data compression information regarding a single Data
Link Connection Identifier.
Indexes
frDcpCircuitIfIndex frDcpCircuitDlci
Column Syntax OID
frDcpCircuitIfIndex mandatory
The ifIndex value of ifEntry that this DCP virtual circuit
object is layered onto.
Index
Textual Convention: Index Integer32
.1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.1
frDcpCircuitDlci mandatory
The Data Link Connection Identifier for this DCP virtual
circuit object.
DLCI
Textual Convention: DLCI Integer32
.1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.2
frDcpCircuitEnable mandatory
Indicates whether data compression should take place on
this particular end side virtual circuit.
Enumerationr/w
Enumerated Values:
1on
2off
.1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.3
frDcpCircuitStatus mandatory
On indicates that the compression has been successfully
negotiated and is operating. Off indicates that the
compression negotiation has failed and compression is not
operating at this time, or compression has been termi…
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.4
frDcpCircuitRatio mandatory
The ratio of uncompressed to compressed transmitted data.
If the data compression status is off, 1:1 will be displayed
OctetString
Constraints:
range: 5-5
.1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.5

ddsConfigTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.7.1.5.1 · 1 row entry · 9 columns
The DDS Configuration Table
ddsConfigEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.5.1.1
An Entry in the DDS Configuration Table
Indexes
ddsLineIndex
Column Syntax OID
ddsLineIndex mandatory
A unique value for each dds physical port on the
platform
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.1
ddsIfIndex mandatory
Index associated with this dds physical port
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.2
ddsLineMode mandatory
DDS-PRI is full duplex 56k link, No framing in loop
data so loop speed is also 56k. Data stream:
--d1 d2 d3 d4 d5 d6 d7--

DDS-CC is full duplex 64k link. Does not require framing
bit but …
Enumerationr/w
Enumerated Values:
1ddsPri
2ddsCc
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.3
ddsLineCoding mandatory
This object describes the variety of Zero Code
suppression on this interface. JBZS refers to Jammed
Bit Zero suppression, which forces a 1 bit every 8 bit
periods. None refers to a mode in which some other
means is…
Enumerationr/w
Enumerated Values:
1ddsNone
2ddsJBZS
3otherLineCode
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.4
ddsLoopbackConfig mandatory
This variable represents the loop-back configuration
of the DDS interface. ddsNoLoop means the interface is
not in loop-back state, and LineLoop means the the
received data is looped back out.
Enumerationr/w
Enumerated Values:
1ddsNoLoop
2ddsLineLoop
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.5
ddsLineStatus mandatory
This describes the current operational
status of DDS line.
Enumeration
Enumerated Values:
1ddsNoAlarm
2ddsLossOfSignal
3ddsOutOfService
4ddsOutOfFrame
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.6
ddsTxClockSource mandatory
The source of Transmit clock.
ddsLoopTiming - indicates that the recovered receive
clock is used as transmit clock.
ddsLocalTiming - indicates that a local clock source is
used.
Enumerationr/w
Enumerated Values:
1ddsLoopTiming
2ddsLocalTiming
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.7
ddsPortInSpeed mandatory
This variable describes the current operational
receive speed of DDS line. It is a read only value
based entirely on DDS type (CC or PRI).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.8
ddsPortOutSpeed mandatory
This variable describes the current operational
transmit speed of DDS line. It is a read only value
based entirely on DDS type CC or PRI
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.9

ds1AlarmConfigTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.7.1.6.2 · 1 row entry · 9 columns
Table containing objects used to configure DS1 alarm 
functionality on a per DS1 basis.
ds1AlarmConfigEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.6.2.1
A description of a single entry.
Indexes
ds1PhysNum
Column Syntax OID
ds1PhysNum mandatory
The value for this object is equal to the value
of a unique physical connection identifier associated
with this DS1 which is clearly labeled on the device.
For those products that do not have a DS1 identifier
labeled on…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.1
ds1AlarmAdmin mandatory
Used to enable and disable the DS1 Alarm
Monitoring Application for this DS1 circuit.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.2
ds1AlarmAutoRecovery mandatory
Used to enable and disable the DS1 Alarm
Automatic Recovery feature for this DS1 circuit.
For those devices that support ds1
alarm monitoring, but do not support the automatic
recovery feature, this object always return…
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.3
ds1AlarmTrapEnable mandatory
Used to enable and disable the DS1 Alarm
SNMP Trap generation feature for this DS1 circuit.
This object operates in conjunction with configuration
of objects in the ctron-trap-mib.txt
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.4
ds1AlarmESCount mandatory
Used in conjuction with ctDs1AlarmESInterval to set
the threshold for alarm generation when the number of
Errored Seconds for a specified time interval, measured
in minutes, is exceeded. The default Errored Seconds …
Integer32r/w
Constraints:
range: 1-300
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.5
ds1AlarmESInterval mandatory
Used in conjuction with ctDs1AlarmESCount to set the
threshold for alarm generation when the number of
Errored Seconds for a specified time interval, measured
in minutes, is exceeded. The default Errored Seconds
al…
Integer32r/w
Constraints:
range: 1-15
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.6
ds1AlarmBPVErrorRate mandatory
Used to specify the negative exponent of 10, used in
monitoring Bipolar Violations (Code Violations for E1)
over intervals defined by ds1AlarmBPVInterval. For
example, for a ds1AlarmBPVErrorRate value of 6 used
with …
Integer32r/w
Constraints:
range: 5-9
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.7
ds1AlarmBPVInterval mandatory
Used to specify the interval, used in
monitoring Bipolar Violations (Code Violations for E1)
with thresholds defined by ds1AlarmBPVErrorRate. For
example, for a ds1AlarmBPVErrorRate value of 6 used
with a ds1AlarmBPV…
Integer32r/w
Constraints:
range: 1-15
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.8
ds1AlarmManualRecovery mandatory
To cause a manual recovery to occur, this object is set
to a 1. It is always read as a 1. The recovery will
occur only when automatic recovery is disabled.
Enumerationr/w
Enumerated Values:
1recover
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.9

ipPQAddressTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.7.1.7.2 · 1 row entry · 2 columns
Table containing IP addresses, used in an
IP Priority Queue Forwarding function.
ipPQAddressEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.7.2.1
A description of a single entry.
Indexes
ipPQAddressId
Column Syntax OID
ipPQAddressId mandatory
A unique value identifying an element in a sequence
of IP PQ address entries.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.52.4.1.2.7.1.7.2.1.1
ipPQIPAddress mandatory
Returns an IP address associated with a specific
entry in this table.
RFC1155-SMIIpAddress
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.52.4.1.2.7.1.7.2.1.2
.1.3.6.1.4.1.52.4.1.2.7.1.8.1 · 1 row entry · 26 columns
HDSL 15 minute performance table. This table provides the 
accumulated counts of errored seconds (ES) and unavailable 
seconds (UAS) for the HDSL line including the local, remote
units and any doublers in between during a 15 minutes period
for the last 24 hours. 
          
The table is indexed by the non-empty slot in the device and
the 15-minute history slot within the last 24 hours period.
ctWanHDSLPerformance15mEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.8.1.1
Entries in the 15 minute performance table
Indexes
ctWanHDSLPerformance15mConnIndex ctWanHDSLPerformance15mSlotIndex
Column Syntax OID
ctWanHDSLPerformance15mConnIndex mandatory
Identify the HDSL connection within the device, indexing from
1 to the maximum allowed number of HDSL connections in the
device.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.1
ctWanHDSLPerformance15mSlotIndex mandatory
Define which 15-minute slot history of the HDSL within the
24 hour period. Indexing from 1 - 97 with the first index
representing the current 15-minute history
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.2
ctWanHDSLHLULoop1UAS15m mandatory
Unavailable seconds (UAS) on LOOP 1 of the local line unit during
the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.3
ctWanHDSLHLULoop1ES15m mandatory
Errored seconds (ES) on LOOP 1 of the local line unit during
the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.4
ctWanHDSLHLULoop2UAS15m mandatory
Unavailable seconds (UAS) on LOOP 2 of the local line unit during
the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.5
ctWanHDSLHLULoop2ES15m mandatory
Errored seconds (ES) on LOOP 2 of the local line unit during
the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.6
ctWanHDSLHRULoop1UAS15m mandatory
Unavailable seconds (UAS) on LOOP 1 of the remote line unit during
the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.7
ctWanHDSLHRULoop1ES15m mandatory
Errored seconds (ES) on LOOP 1 of the remote line unit during
the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.8
ctWanHDSLHRULoop2UAS15m mandatory
Unavailable seconds (UAS) on LOOP 2 of the remote line unit during
the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.9
ctWanHDSLHRULoop2ES15m mandatory
Errored seconds (ES) on LOOP 2 of the remote line unit during
the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.10
ctWanHDSLDb1NetworkLoop1UAS15m mandatory
Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
network side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.11
ctWanHDSLDb1NetworkLoop1ES15m mandatory
Errored seconds (ES) on LOOP 1 of the first doubler unit's
network side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.12
ctWanHDSLDb1NetworkLoop2UAS15m mandatory
Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
network side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.13
ctWanHDSLDb1NetworkLoop2ES15m mandatory
Errored seconds (ES) on LOOP 2 of the first doubler unit's
network side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.14
ctWanHDSLDb1CustomerLoop1UAS15m mandatory
Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
customer side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.15
ctWanHDSLDb1CustomerLoop1ES15m mandatory
Errored seconds (ES) on LOOP 1 of the first doubler unit's
customer side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.16
ctWanHDSLDb1CustomerLoop2UAS15m mandatory
Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
customer side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.17
ctWanHDSLDb1CustomerLoop2ES15m mandatory
Errored seconds (ES) on LOOP 2 of the first doubler unit's
customer side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.18
ctWanHDSLDb2NetworkLoop1UAS15m mandatory
Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
network side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.19
ctWanHDSLDb2NetworkLoop1ES15m mandatory
Errored seconds (ES) on LOOP 2 of the second doubler unit's
network side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.20
ctWanHDSLDb2NetworkLoop2UAS15m mandatory
Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
network side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.21
ctWanHDSLDb2NetworkLoop2ES15m mandatory
Errored seconds (ES) on LOOP 2 of the second doubler unit's
network side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.22
ctWanHDSLDb2CustomerLoop1UAS15m mandatory
Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
customer side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.23
ctWanHDSLDb2CustomerLoop1ES15m mandatory
Errored seconds (ES) on LOOP 1 of the second doubler unit's
customer side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.24
ctWanHDSLDb2CustomerLoop2UAS15m mandatory
Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
customer side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.25
ctWanHDSLDb2CustomerLoop2ES15m mandatory
Errored seconds (ES) on LOOP 2 of the second doubler unit's
customer side during the 15-minute period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.26
.1.3.6.1.4.1.52.4.1.2.7.1.8.2 · 1 row entry · 26 columns
HDSL 24-hour performance table. This table provides the
accumulated counts of errored seconds (ES) and unavailable
seconds (UAS) for the HDSL line including the local, remote
units and any doublers in between during a 24-hour period
for the last 7 days.
          
The table is indexed by the non-empty slot in the device and
the 24-hour history slot within the last 7 days period.
ctWanHDSLPerformance24hEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.8.2.1
Entries in the 24-hour ctWanHDSLPerformance table
Indexes
ctWanHDSLPerformance24hConnIndex ctWanHDSLPerformance24hSlotIndex
Column Syntax OID
ctWanHDSLPerformance24hConnIndex mandatory
Identify the HDSL connection within the device, indexing from
1 to the maximum allowed number of HDSL connections in the
device.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.1
ctWanHDSLPerformance24hSlotIndex mandatory
Define which 24-hour slot history of the HDSL within the
last 7 days period. Indexing from 1 - 8 with the first index
representing the current 24 hour history
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.2
ctWanHDSLHLULoop1UAS24h mandatory
Unavailable seconds (UAS) on LOOP 1 of the local line unit during
the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.3
ctWanHDSLHLULoop1ES24h mandatory
Errored seconds (ES) on LOOP 1 of the local line unit during
the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.4
ctWanHDSLHLULoop2UAS24h mandatory
Unavailable seconds (UAS) on LOOP 2 of the local line unit during
the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.5
ctWanHDSLHLULoop2ES24h mandatory
Errored seconds (ES) on LOOP 2 of the local line unit during
the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.6
ctWanHDSLHRULoop1UAS24h mandatory
Unavailable seconds (UAS) on LOOP 1 of the remote line unit during
the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.7
ctWanHDSLHRULoop1ES24h mandatory
Errored seconds (ES) on LOOP 1 of the remote line unit during
the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.8
ctWanHDSLHRULoop2UAS24h mandatory
Unavailable seconds (UAS) on LOOP 2 of the remote line unit during
the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.9
ctWanHDSLHRULoop2ES24h mandatory
Errored seconds (ES) on LOOP 2 of the remote line unit during
the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.10
ctWanHDSLDb1NetworkLoop1UAS24h mandatory
Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
network side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.11
ctWanHDSLDb1NetworkLoop1ES24h mandatory
Errored seconds (ES) on LOOP 1 of the first doubler unit's
network side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.12
ctWanHDSLDb1NetworkLoop2UAS24h mandatory
Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
network side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.13
ctWanHDSLDb1NetworkLoop2ES24h mandatory
Errored seconds (ES) on LOOP 2 of the first doubler unit's
network side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.14
ctWanHDSLDb1CustomerLoop1UAS24h mandatory
Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
customer side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.15
ctWanHDSLDb1CustomerLoop1ES24h mandatory
Errored seconds (ES) on LOOP 1 of the first doubler unit's
customer side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.16
ctWanHDSLDb1CustomerLoop2UAS24h mandatory
Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
customer side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.17
ctWanHDSLDb1CustomerLoop2ES24h mandatory
Errored seconds (ES) on LOOP 2 of the first doubler unit's
customer side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.18
ctWanHDSLDb2NetworkLoop1UAS24h mandatory
Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
network side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.19
ctWanHDSLDb2NetworkLoop1ES24h mandatory
Errored seconds (ES) on LOOP 1 of the second doubler unit's
network side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.20
ctWanHDSLDb2NetworkLoop2UAS24h mandatory
Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
network side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.21
ctWanHDSLDb2NetworkLoop2ES24h mandatory
Errored seconds (ES) on LOOP 2 of the second doubler unit's
network side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.22
ctWanHDSLDb2CustomerLoop1UAS24h mandatory
Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
customer side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.23
ctWanHDSLDb2CustomerLoop1ES24h mandatory
Errored seconds (ES) on LOOP 1 of the second doubler unit's
customer side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.24
ctWanHDSLDb2CustomerLoop2UAS24h mandatory
Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
customer side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.25
ctWanHDSLDb2CustomerLoop2ES24h mandatory
Errored seconds (ES) on LOOP 2 of the second doubler unit's
customer side during the 24-hour period.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.26
.1.3.6.1.4.1.52.4.1.2.7.1.8.3 · 1 row entry · 51 columns
This table collects the statistics for the Signal noise ratio 
(SNR), and the pulse attenuation of the HDSL line, including
the local, remote units and the doublers in between.
ctWanHDSLStatisticsEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.8.3.1
Entries of the HDSL statistics table
Indexes
ctWanHDSLStatisticsHLUConnIndex
Column Syntax OID
ctWanHDSLStatisticsHLUConnIndex mandatory
Identify the HDSL connection occupied in the device,
indexing from 1 to the maximum allowed connections in
the device.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.1
ctWanHDSLSNRHLULoop1 mandatory
Current SNR on LOOP 1 of the local line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.2
ctWanHDSLSNRLowHLULoop1 mandatory
Lowest SNR on LOOP 1 of the local line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.3
ctWanHDSLSNRHighHLULoop1 mandatory
Highest SNR on LOOP 1 of the local line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.4
ctWanHDSLSNRHLULoop2 mandatory
Current SNR on LOOP 2 of the local line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.5
ctWanHDSLSNRLowHLULoop2 mandatory
Lowest SNR on LOOP 2 of the local line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.6
ctWanHDSLSNRHighHLULoop2 mandatory
Highest SNR on LOOP 2 of the local line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.7
ctWanHDSLPulseAttenuationHLULoop1 mandatory
pulse Attenuation on LOOP 1 of the local line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.8
ctWanHDSLPulseAttenuationHLULoop2 mandatory
pulse Attenuation on LOOP 2 of the local line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.9
ctWanHDSLBitStat1HLU mandatory
A byte value which contains product specific information:

bit 0 - System in AIS on the local line unit.
1 - System in AIS on the remote line unit.
2 - Channels are reversed on the remote line u…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.10
ctWanHDSLSNRHRULoop1 mandatory
Current SNR on LOOP 1 of the remote line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.11
ctWanHDSLSNRLowHRULoop1 mandatory
Lowest SNR on LOOP 1 of the remote line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.12
ctWanHDSLSNRHighHRULoop1 mandatory
Highest SNR on LOOP 1 of the remote line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.13
ctWanHDSLSNRHRULoop2 mandatory
Current SNR on LOOP 2 of the remote line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.14
ctWanHDSLSNRLowHRULoop2 mandatory
Lowest SNR on LOOP 2 of the remote line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.15
ctWanHDSLSNRHighHRULoop2 mandatory
Highest SNR on LOOP 2 of the remote line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.16
ctWanHDSLPulseAttenuationHRULoop1 mandatory
pulse Attenuation on LOOP 1 of the remote line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.17
ctWanHDSLPulseAttenuationHRULoop2 mandatory
pulse Attenuation on LOOP 2 of the remote line unit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.18
ctWanHDSLDs1FrameHRU mandatory
Byte value shows DS1 frame and code information for the remote
line unit (HiGain only):

bit 0:1 -
0 - frame format is SF.
1 - frame format is ESF.
2 - Frame format is unframed.
3 - no act…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.19
ctWanHDSLSNRDb1NetworkLoop1 mandatory
Current SNR on LOOP 1 of doubler 1's network side
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.20
ctWanHDSLSNRLowDb1NetworkLoop1 mandatory
Lowest SNR on LOOP 1 of doubler 1's network side
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.21
ctWanHDSLSNRHighDb1NetworkLoop1 mandatory
Highest SNR on LOOP 1 of doubler 1's network side
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.22
ctWanHDSLSNRDb1NetworkLoop2 mandatory
Current SNR on LOOP 2 of doubler 1's network side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.23
ctWanHDSLSNRLowDb1NetworkLoop2 mandatory
Lowest SNR on LOOP 2 of doubler 1's network side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.24
ctWanHDSLSNRHighDb1NetworkLoop2 mandatory
Highest SNR on LOOP 2 of doubler 1's network side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.25
ctWanHDSLSNRDb1CustomerLoop1 mandatory
Current SNR on LOOP 1 of doubler 1's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.26
ctWanHDSLSNRLowDb1CustomerLoop1 mandatory
Lowest SNR on LOOP 1 of doubler 1's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.27
ctWanHDSLSNRHighDb1CustomerLoop1 mandatory
Highest SNR on LOOP 1 of doubler 1's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.28
ctWanHDSLSNRDb1CustomerLoop2 mandatory
Current SNR on LOOP 2 of doubler 1's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.29
ctWanHDSLSNRLowDb1CustomerLoop2 mandatory
Lowest SNR on LOOP 2 of doubler 1's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.30
ctWanHDSLSNRHighDb1CustomerLoop2 mandatory
Highest SNR on LOOP 2 of doubler 1's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.31
ctWanHDSLPulseAttenuationDb1NetworkLoop1 mandatory
Pulse Attenuation on LOOP 1 of doubler 1's network side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.32
ctWanHDSLPulseAttenuationDb1NetworkLoop2 mandatory
Pulse Attenuation on LOOP 2 of doubler 1's network side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.33
ctWanHDSLPulseAttenuationDb1CustomerLoop1 mandatory
Pulse Attenuation on LOOP 1 of doubler 1's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.34
ctWanHDSLPulseAttenuationDb1CustomerLoop2 mandatory
pulse Attenuation on LOOP 2 of doubler 1's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.35
ctWanHDSLSNRDb2NetworkLoop1 mandatory
Current SNR on LOOP 1 of doubler 2's network side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.36
ctWanHDSLSNRLowDb2NetworkLoop1 mandatory
Lowest SNR on LOOP 1 of doubler 2's network side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.37
ctWanHDSLSNRHighDb2NetworkLoop1 mandatory
Highest SNR on LOOP 1 of doubler 2's network side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.38
ctWanHDSLSNRDb2NetworkLoop2 mandatory
Current SNR on LOOP 2 of doubler 2's network side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.39
ctWanHDSLSNRLowDb2NetworkLoop2 mandatory
Lowest SNR on LOOP 2 of doubler 2's network side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.40
ctWanHDSLSNRHighDb2NetworkLoop2 mandatory
Highest SNR on LOOP 2 of doubler 2's network side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.41
ctWanHDSLSNRDb2CustomerLoop1 mandatory
Current SNR on LOOP 1 of doubler 2's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.42
ctWanHDSLSNRLowDb2CustomerLoop1 mandatory
Lowest SNR on LOOP 1 of doubler 2's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.43
ctWanHDSLSNRHighDb2CustomerLoop1 mandatory
Highest SNR on LOOP 1 of doubler 2's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.44
ctWanHDSLSNRDb2CustomerLoop2 mandatory
Current SNR on LOOP 2 of doubler 2's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.45
ctWanHDSLSNRLowDb2CustomerLoop2 mandatory
Lowest SNR on LOOP 2 of doubler 2's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.46
ctWanHDSLSNRHighDb2CustomerLoop2 mandatory
Highest SNR on LOOP 2 of doubler 2's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.47
ctWanHDSLPulseAttenuationDb2NetworkLoop1 mandatory
Pulse Attenuation on LOOP 1 of doubler 2's network side
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.48
ctWanHDSLPulseAttenuationDb2NetworkLoop2 mandatory
Pulse Attenuation on LOOP 2 of doubler 2's network side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.49
ctWanHDSLPulseAttenuationDb2CustomerLoop1 mandatory
pulse Attenuation on LOOP 1 of doubler 2's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.50
ctWanHDSLPulseAttenuationDb2CustomerLoop2 mandatory
Pulse Attenuation on LOOP 2 of doubler 2's customer side.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.51

ctWanHDSLTestTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.7.1.8.4 · 1 row entry · 4 columns
Test result for the HDSL line, the current test results only
apply to the local line unit.
ctWanHDSLTestEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.8.4.1
Entries of the HDSL test results table.
Indexes
ctWanHDSLTestHLUConnIndex
Column Syntax OID
ctWanHDSLTestHLUConnIndex mandatory
Identify the slot of the HDSL within the device that the user
wants to conduct the line unit test. Slot number start from
1 to maximum slots available in the device.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.4.1.1
ctWanHDSLTestMode mandatory
This object may only be successfully set on a master device.
When this object is set, the local unit's test mode is
defined by these values when set:

1 - Normal operation
3 - Self test mode
4 - P…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.4.1.2
ctWanHDSLHLUTestResult mandatory
Test result for the local line unit (1 - test failed, 0 - success):
bit 0 - 2180 DS1 frame sync test (HiGain only)
1 - 2180 DS1 data test (HiGain only)
2 - LIU DS1 frame sync test (HiGain only)
3 - LIU DS1 d…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.4.1.3
ctWanHDSLHRUTestResult mandatory
Test results for the remote line unit,
Bit definitions correspond to those defined for
ctWanHDSLHLUTestResult.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.4.1.4

ctWanHDSLAlarmsTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.7.1.8.5 · 1 row entry · 3 columns
This table collects the existing alarms information for the HDSL
line, including the local, remote line units and the doublers.
ctWanHDSLAlarmsEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.8.5.1
Entries for the ctWanHDSL alarms information
Indexes
ctWanHDSLAlarmsHLUConnIndex
Column Syntax OID
ctWanHDSLAlarmsHLUConnIndex mandatory
Identify which HDSL connection within the device that
the user wants to retrieve the alarm information.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.5.1.1
ctWanHDSLAlarmsBackplane mandatory
Specific information that's related to the HDSL alarms, each bit
in the two bytes value has the following meaning if set:

Bit 0 : Local Loss of Signal on DS1 line (HiGain only).
1 : Remote Loss of Si…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.5.1.2
ctWanHDSLAlarmsES mandatory
A two bytes value for the Errored Second indication of the HDSL
line unit, including local, remote line units and the doublers.
each bit in the two bytes value has the following meaning if set:

Bit 0 : …
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.5.1.3
.1.3.6.1.4.1.52.4.1.2.7.1.8.6 · 1 row entry · 35 columns
HDSL Alarm History table. This table provides the accumulated 
counts of Errored Seconds (ES) and Loss of Sync words (LOS)
as well as the time stamp of the above events occurred for both
of the HDSL loops.
          
The time stamps show the date in MMDDYYYYHHMM format.
ctWanHDSLAlarmHistoryEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.8.6.1
Entries in the Alarm History table
Indexes
ctWanHDSLAlarmHistoryConnIndex
Column Syntax OID
ctWanHDSLAlarmHistoryConnIndex mandatory
Defines which HDSL connection's alarm history within the
device.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.1
ctWanHDSLAlHistLLOSFirst mandatory
Time stamp of the first time the DS1 Loss Of Signal (LOS)
occurred on the local side of the HDSL.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.2
ctWanHDSLAlHistLLOSLast mandatory
Time stamp of the last time the DS1 Loss Of Signal (LOS)
occurred on the local side of the HDSL.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.3
ctWanHDSLAlHistLLOSCurrent mandatory
Set if the DS1 Loss Of Signal (LOS) still occurred on the
local side of the HDSL.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.4
ctWanHDSLAlHistLLOSCount mandatory
Number of times the DS1 Loss Of Signal (LOS) occurred since
we last cleared the alarm history on the local side of the HDSL.
(HiGain only)
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.5
ctWanHDSLAlHistRLOSFirst mandatory
Time stamp of the first time the DS1 Loss Of Signal (LOS)
occurred on the remote side of the HDSL. (HiGain only)
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.6
ctWanHDSLAlHistRLOSLast mandatory
Time stamp of the last time the DS1 Loss Of Signal (LOS) occurred
on the remote side of the HDSL. (HiGain only)
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.7
ctWanHDSLAlHistRLOSCurrent mandatory
Set if the DS1 Loss Of Signal (LOS) still occurred on the remote
site of the HDSL. (HiGain only)
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.8
ctWanHDSLAlHistRLOSCount mandatory
Number of times the DS1 Loss Of Signal (LOS) occurred since we
last cleared the alarm history on the remote site of the HDSL.
(HiGain only)
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.9
ctWanHDSLAlHistLOSW1First mandatory
Time stamp of the first time the Loss Of Sync Word (LOSW) occurred
on the LOOP 1 of the HDSL link.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.10
ctWanHDSLAlHistLOSW1Last mandatory
Time stamp of the last time the Loss Of Sync Word (LOSW) occurred
on the LOOP 1 of the HDSL link.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.11
ctWanHDSLAlHistLOSW1Current mandatory
Set if the Loss Of Sync Word (LOSW) still occurred on the LOOP 1
of the HDSL link.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.12
ctWanHDSLAlHistLOSW1Count mandatory
Number of times the Loss Of Sync Word (LOSW) occurred since we
last cleared the history on the LOOP 1 of the HDSL link.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.13
ctWanHDSLAlHistLOSW2First mandatory
Time stamp of the first time the Loss Of Sync Word (LOSW) occurred
on the LOOP 2 of the HDSL link.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.14
ctWanHDSLAlHistLOSW2Last mandatory
Time stamp of the last time the Loss Of Sync Word (LOSW) occurred
on the LOOP 2 of the HDSL link.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.15
ctWanHDSLAlHistLOSW2Current mandatory
Set if the Loss Of Sync Word (LOSW) still occurred on the LOOP 2
of the HDSL link.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.16
ctWanHDSLAlHistLOSW2Count mandatory
Number of times the Loss Of Sync Word (LOSW) occurred since we
last cleared the history on the LOOP 2 of the HDSL link.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.17
ctWanHDSLAlHistES1First mandatory
Time stamp of the first time the Errored Seconds (ES) occurred
on the LOOP 1 of the HDSL link.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.18
ctWanHDSLAlHistES1Last mandatory
Time stamp of the last time the Errored Seconds (ES) occurred
on the LOOP 1 of the HDSL link.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.19
ctWanHDSLAlHistES1Current mandatory
Set if the Errored Seconds (ES) still occurred on the LOOP 1 of
the HDSL link.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.20
ctWanHDSLAlHistES1Count mandatory
Number of times the Errored Seconds (ES) occurred since we last
cleared the alarm history on the LOOP 1 of the HDSL link.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.21
ctWanHDSLAlHistES2First mandatory
Time stamp of the first time the Errored Seconds (ES) occurred
on the LOOP 2 of the HDSL link.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.22
ctWanHDSLAlHistES2Last mandatory
Time stamp of the last time the Errored Seconds (ES) occurred
on the LOOP 2 of the HDSL link.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.23
ctWanHDSLAlHistES2Current mandatory
Set if the Errored Seconds (ES) still occurred on the LOOP 2 of
the HDSL link.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.24
ctWanHDSLAlHistES2Count mandatory
Number of times the Errored Seconds (ES) occurred since we last
cleared the history on the LOOP 2 of the HDSL link.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.25
ctWanHDSLAlHistMargin1First mandatory
Time stamp of the first time the alarms exceeded the
Margin Threshold on LOOP 1 of the HDSL link.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.26
ctWanHDSLAlHistMargin1Last mandatory
Time stamp of the last time the alarms exceeded the Margin
Threshold on the LOOP 1 of the HDSL link.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.27
ctWanHDSLAlHistMargin1Current mandatory
Set if the alarms still exceeded the Margin Threshold
on the LOOP 1 of the HDSL link.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.28
ctWanHDSLAlHistMargin1Count mandatory
Number of times the alarm exceeded the Margin Threshold since
we last cleared the alarm history on the LOOP 1 of the HDSL link.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.29
ctWanHDSLAlHistMargin2First mandatory
Time stamp of the first time the alarms exceeded the Margin
Threshold on LOOP 2 of the HDSL link.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.30
ctWanHDSLAlHistMargin2Last mandatory
Time stamp of the last time the alarms exceeded the Margin
Threshold on the LOOP 2 of the HDSL link.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.31
ctWanHDSLAlHistMargin2Current mandatory
Set if the alarms still exceeded the Margin Threshold
on the LOOP 2 of the HDSL link.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.32
ctWanHDSLAlHistMargin2Count mandatory
Number of times the alarm exceeded the Margin Threshold since
we last cleared the alarm history on the LOOP 2 of the HDSL link.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.33
ctWanHDSLAlHistCleared mandatory
Time stamp of the time user requested to clear the alarm history.
OctetString
Constraints:
range: 12-12
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.34
ctWanHDSLAlHistClearit mandatory
set to a 1 to clear the alarm history.
A read of this value always returns a 1.

NOTE: the setting of this object also causes the SNR low
value, SNR high value, and the performance history to be
reset.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.35
.1.3.6.1.4.1.52.4.1.2.7.1.8.7 · 1 row entry · 3 columns
HDSL Loopback table. This table provides the certain loopback 
settings for the HDSL link.
ctWanHDSLLoopbacksEntry entry .1.3.6.1.4.1.52.4.1.2.7.1.8.7.1
Entries in the HDSL Loopback table.
Indexes
ctWanHDSLLoopbacksHLUConnIndex
Column Syntax OID
ctWanHDSLLoopbacksHLUConnIndex mandatory
Identify the HDSL connection within the device
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.7.1.1
ctWanHDSLLoopbacksAdminType mandatory
This is the requested loopback type for the HDSL.

loopbacks setting:
1 : Smartjack - loopback to network at remote line unit.
2 : Loopback to network at local line unit.
3 : Loopback to netw…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.7.1.2
ctWanHDSLLoopbacksOperType mandatory
This is the operational loopback type for the HDSL.

loopbacks setting:
1 : Smartjack - loopback to network at remote line unit.
2 : Loopback to network at local line unit.
3 : Loopback to ne…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.7.1.8.7.1.3