CTRON-WAN-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
16
Rows
16
Columns
216
.1.3.6.1.4.1.52.4.1.2.7.1.1.2
·
1 row entry
·
4 columns
A list of wan connection entries. The number of wan connection entries is given by the value of wanNumConnections.
A wan connection entry containing objects relating to
the particular wan connection.
the particular wan connection.
Indexes
wanConnIndex
| Column | Syntax | OID |
|---|---|---|
|
wanConnIndex
mandatory
A unique value for each wan connection. Its value ranges
between 1 and the value wanNumConnections. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.2.1.1 |
|
wanConnNumPhysPorts
mandatory
The number of physical ports that exist on this wan
connection. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.2.1.2 |
|
wanConnDefaultPhysPort
mandatory
The default physical port for this connection. This
indicates the physical port that should be used on this wan connection. If redundancy is not enabled, this physical port will always be used. If redundancy is enabled… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.2.1.3 |
|
wanConnActivePhysPort
mandatory
The physical port that is currently active for this wan
connection. The value of this object indicates the wanPhysPortIndex for the active port. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.2.1.4 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.3
·
1 row entry
·
4 columns
A list of the descriptions of the physical ports of this platform. The number of entries is given by the value of wanConnNumPhysPort for each Wan Connection.
A physical port entry. It contains objects relating to a
given physical port
given physical port
Indexes
wanPhysPortConnectionIndex wanPhysPortIndex
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
wanPhysPortConnectionIndex
mandatory
A value indicating the wan connection this physical port
is located on. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.3.1.1 |
||||||||||||||||||||
|
wanPhysPortIndex
mandatory
A unique value for each physical port on a wan connection.
Its value ranges between 1 and the value wanConnNumPhysPorts. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.3.1.2 |
||||||||||||||||||||
|
wanPhysPortType
mandatory
The type of physical port that this entry describes. None
indicates that the physical port has no connector. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.1.3.1.3 |
||||||||||||||||||||
|
wanPhysPortSpecificMib
mandatory
This object identifies an instance of the index object in
the first group of objects in the MIB specific to the physical port. |
ObjectIdentifier | .1.3.6.1.4.1.52.4.1.2.7.1.1.3.1.4 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.4
·
1 row entry
·
14 columns
The interface table for a physical port on a wan connection. It is a list of items that are pertinent to the interfaces that are part of this physical port. The number of entries is dependent on the wanPhysPortType for the interface. If the wanPhysPortType is none, there will be no entries in the table for the port. If the wanPhysPortType is t1, there will be 24 entries in this table for the port. If the wanPhysPortType is e1, there will be 30 entries in this table for the port. If the wanPhysPortType is synchronous, there will be one entry in this table for the port.
A wan connection physical port interface entry. It
contains objects relating to an interface that is defined
for this physical port and this wan connection.
contains objects relating to an interface that is defined
for this physical port and this wan connection.
Indexes
wanInterfaceConnectionIndex wanInterfacePhysPortIndex wanInterfaceEntryIndex
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
wanInterfaceConnectionIndex
mandatory
This value is the wan connection that this interface
exists on. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.1 |
||||||
|
wanInterfacePhysPortIndex
mandatory
This value is the physical port of the wan connection
that this interface exists on. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.2 |
||||||
|
wanInterfaceEntryIndex
mandatory
A unique value for each interface of this physical port.
It is a value between 1 and the number of interfaces that exist for the current port. The number of interfaces for each type of port is: 24 for a port type (wanPh… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.3 |
||||||
|
wanInterfaceEntryIfIndex
mandatory
The ifIndex of the interface. This is the index of this entry
in the ifTable. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.4 |
||||||
|
wanInterfaceEntryProtocol
mandatory
The protocol that should be run on this interface. Values
are equivalent to those defined for ifType in Mib-II. Accepted values are product dependent. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.5 |
||||||
|
wanInterfaceEntryCompression
mandatory
Indicates whether data compression should take
place on this interface. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.6 |
||||||
|
wanInterfaceEntryMTU
mandatory
The MTU to be negotiated for this interface. This will not
be updated with the actual MTU, which can be found in the ifTable. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.7 |
||||||
|
wanInterfaceEntryLineCoding
mandatory
This object describes the variety of Zero Code suppression
on this interface. For an interface on a Ds1 Port, the valid values depend on the value of the Ds1ConfigLineCode object. If that object is set to ds1xB8ZS, then… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.8 |
||||||
|
wanInterfaceEntryCrcLength
mandatory
The Length of the CRC for this interface. Not all platforms
will allow all options. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.9 |
||||||
|
wanInterfaceEntryLexProtocolEnable
obsolete
This switch acts in concert with the wanInterfaceEntryProtocol
object. To activate LEX, this object should first be set to enable (1), then set the wanInterfaceEntryProtocol to PPP. The enable will have no effect if … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.10 |
||||||
|
wanInterfaceEntryLexProtocolStatus
obsolete
This object reflects the current state of the link. The device
is said to be bound to the router when the physical link is OK, the LEX negotiation is successful, and the router has been configured correctly to communic… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.11 |
||||||
|
wanInterfaceEntryCompRatio
mandatory
The ratio of uncompressed to compressed transmitted data.
If the data compression status is off, 1:1 will be displayed |
OctetString Constraints: range: 6-6 |
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.12 |
||||||
|
wanInterfaceEntryCompStatus
mandatory
On indicates that the compression has been successfully
negotiated and is operating. Off indicates that the compression negotiation has failed and compression is not operating at this time, or compression has been termi… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.13 |
||||||
|
wanInterfaceEntryBackUpIfEnable
mandatory
This object is used to select the Call-backup option.
A value of 1 is used to enable the option and a value of 2 to disable it. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.1.4.1.14 |
.1.3.6.1.4.1.52.4.1.2.7.1.2.1
·
1 row entry
·
18 columns
This table is an extension to the standard ds1 configuration table. It is a list of items that are pertinent to ds1 ports on a platform. There is one entry per ds1 physical port on the platform
A ds1 extensions entry containing objects relating to
the particular ds1 physical port
the particular ds1 physical port
Indexes
wanDs1ExtensionsEntryIndex
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
wanDs1ExtensionsEntryIndex
mandatory
A unique value for each ds1 physical port on the platform.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.1 |
||||||||||||||||
|
wanDs1ExtensionsNumInterfaces
mandatory
The number of interfaces on this physical port. This
number indicates the number of entries this physical port uses in the ifTable. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.2 |
||||||||||||||||
|
wanDs1ExtensionsToggleFracTable
mandatory
Setting this object to 1 will cause the Ds1 Fractional Table
to be updated with the new values, as entered. Setting this object to 2, will cause the Ds1 Fractional Table to view as the table being entered. Setting this … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.3 |
||||||||||||||||
|
wanDs1ExtensionsLineBuildOut
mandatory
The line build out setting for this ds1 physical port.
Unknown indicates that the setting is neither readable or writable. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.4 |
||||||||||||||||
|
wanDs1ExtensionsCFADuration
mandatory
The length of time (in seconds), that the ds1 port will
remain in the Carrier Failure Alarm state after the alarm condition has cleared. |
Integer32r/w Constraints: range: 1-15 |
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.5 |
||||||||||||||||
|
wanDs1ExtensionsDIEnable
mandatory
Enables or disables Drop and Insert functionality on a
D/I WPIM. If enabled, all zero assigned timeslots will designate D/I interface channels, if disabled all zero channels will designate dummy channels as on a T1 o… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.6 |
||||||||||||||||
|
wanDs1ExtensionsTotalValidIntervals
mandatory
The number of previous intervals for which
valid data was collected for the DS1 mib, which is currently RFC1406. This counter is similar to RFC1406 dsx1ValidIntervals except that the count represents the total numb… |
RFC1155-SMICounter Textual Convention: RFC1155-SMICounter Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.7 |
||||||||||||||||
|
wanDs1ExtensionsBertTestMode
mandatory
This object is used to request that a type of
process be in control of the testing function. This is used to differentiate between automated test procedures and those manually controlled by a user. When read, this ob… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.8 |
||||||||||||||||
|
wanDs1ExtensionsBertRun
mandatory
Controls the sending of test data over this physical
port. The data is a pattern described by wanDs1ExtensionsBertTestPattern. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.9 |
||||||||||||||||
|
wanDs1ExtensionsBertCurrentResults
mandatory
Indicates the results of the testing for the
last completed sampling period. A non-negative number is the error rate in bits per million bits. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.10 |
||||||||||||||||
|
wanDs1ExtensionsBertCumulativeResults
mandatory
Indicates the total number of errors since the
testing was enabled. It is not a rate. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.11 |
||||||||||||||||
|
wanDs1ExtensionsBertPeakResults
mandatory
Indicates the highest value of
wanDs1ExtensionsBertCurrentResults since the testing was enabled. A non-negative number is the error rate in bits per million bits. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.12 |
||||||||||||||||
|
wanDs1ExtensionsBertAverageResult
mandatory
Indicates the average value of
wanDs1ExtensionsBertCurrentResults since the testing was enabled. A non-negative number is the error rate in bits per million bits. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.13 |
||||||||||||||||
|
wanDs1ExtensionsBertTestPattern
mandatory
This object is used to specify the pattern of the
test data. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.14 |
||||||||||||||||
|
wanDs1ExtensionsBertSamplePeriod
mandatory
This object is the duration of time in seconds at
which the current test results will be periodically written to wanDs1ExtensionsBertCurrentResults. The range is 1 to 3600, with a default value of 10. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.15 |
||||||||||||||||
|
wanDs1ExtensionsBertNumPeriods
mandatory
The number of sampling periods that have elapsed
during the current test run. |
RFC1155-SMICounter Textual Convention: RFC1155-SMICounter Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.16 |
||||||||||||||||
|
wanDs1ExtensionsBertTestTraps
mandatory
This object is used to enable or disable the sending
of a trap at the conclusion of the measurement period. The trap will contain the information described by ctDs1BertCurrentResults. The default value is disabled. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.17 |
||||||||||||||||
|
wanDs1ExtensionsBertDataStatus
mandatory
This object provides the operating status of the
transmission of test data packets. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.2.1.1.18 |
.1.3.6.1.4.1.52.4.1.2.7.1.3.1
·
1 row entry
·
3 columns
This table is an extension to the standard rs232-like mib. It is a list of items that are pertinent to rs232-like ports on a platform. There is one entry per synchronous physical port on the platform.
A rs232-like extensions entry containing objects relating to
the particular rs232-like physical port.
the particular rs232-like physical port.
Indexes
wanRs232ExtensionsEntryIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
wanRs232ExtensionsEntryIndex
mandatory
A unique value for each rs232-like physical port on
the platform. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.3.1.1.1 |
||||
|
wanRs232ExtensionsCTSEnable
mandatory
This object indicates whether the platform should generate
CTS. When disabled the platform will not generate CTS, when enabled, the platform will generate CTS. The actual state of the CTS line is available in the rs-23… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.3.1.1.2 |
||||
|
wanRs232ExtensionsDSREnable
mandatory
This object indicates whether the platform should generate
DSR. When disabled the platform will not generate DSR, when enabled, the platform will generate DSR. The actual state of the DSR line is available in the rs-23… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.3.1.1.3 |
.1.3.6.1.4.1.52.4.1.2.7.1.4.1
·
1 row entry
·
5 columns
A table containing data compression information about specific Data Link Connection Identifiers and corresponding virtual circuit. This information is used to support the frCircuitTable following RFC-1315.
The data compression information regarding a single Data
Link Connection Identifier.
Link Connection Identifier.
Indexes
frDcpCircuitIfIndex frDcpCircuitDlci
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
frDcpCircuitIfIndex
mandatory
The ifIndex value of ifEntry that this DCP virtual circuit
object is layered onto. |
Index Textual Convention: Index Integer32 |
.1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.1 |
||||
|
frDcpCircuitDlci
mandatory
The Data Link Connection Identifier for this DCP virtual
circuit object. |
DLCI Textual Convention: DLCI Integer32 |
.1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.2 |
||||
|
frDcpCircuitEnable
mandatory
Indicates whether data compression should take place on
this particular end side virtual circuit. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.3 |
||||
|
frDcpCircuitStatus
mandatory
On indicates that the compression has been successfully
negotiated and is operating. Off indicates that the compression negotiation has failed and compression is not operating at this time, or compression has been termi… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.4 |
||||
|
frDcpCircuitRatio
mandatory
The ratio of uncompressed to compressed transmitted data.
If the data compression status is off, 1:1 will be displayed |
OctetString Constraints: range: 5-5 |
.1.3.6.1.4.1.52.4.1.2.7.1.4.1.1.5 |
.1.3.6.1.4.1.52.4.1.2.7.1.5.1
·
1 row entry
·
9 columns
The DDS Configuration Table
An Entry in the DDS Configuration Table
Indexes
ddsLineIndex
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
ddsLineIndex
mandatory
A unique value for each dds physical port on the
platform |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.1 |
||||||||
|
ddsIfIndex
mandatory
Index associated with this dds physical port
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.2 |
||||||||
|
ddsLineMode
mandatory
DDS-PRI is full duplex 56k link, No framing in loop
data so loop speed is also 56k. Data stream: --d1 d2 d3 d4 d5 d6 d7-- DDS-CC is full duplex 64k link. Does not require framing bit but … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.3 |
||||||||
|
ddsLineCoding
mandatory
This object describes the variety of Zero Code
suppression on this interface. JBZS refers to Jammed Bit Zero suppression, which forces a 1 bit every 8 bit periods. None refers to a mode in which some other means is… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.4 |
||||||||
|
ddsLoopbackConfig
mandatory
This variable represents the loop-back configuration
of the DDS interface. ddsNoLoop means the interface is not in loop-back state, and LineLoop means the the received data is looped back out. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.5 |
||||||||
|
ddsLineStatus
mandatory
This describes the current operational
status of DDS line. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.6 |
||||||||
|
ddsTxClockSource
mandatory
The source of Transmit clock.
ddsLoopTiming - indicates that the recovered receive clock is used as transmit clock. ddsLocalTiming - indicates that a local clock source is used. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.7 |
||||||||
|
ddsPortInSpeed
mandatory
This variable describes the current operational
receive speed of DDS line. It is a read only value based entirely on DDS type (CC or PRI). |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.8 |
||||||||
|
ddsPortOutSpeed
mandatory
This variable describes the current operational
transmit speed of DDS line. It is a read only value based entirely on DDS type CC or PRI |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.5.1.1.9 |
.1.3.6.1.4.1.52.4.1.2.7.1.6.2
·
1 row entry
·
9 columns
Table containing objects used to configure DS1 alarm functionality on a per DS1 basis.
A description of a single entry.
Indexes
ds1PhysNum
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
ds1PhysNum
mandatory
The value for this object is equal to the value
of a unique physical connection identifier associated with this DS1 which is clearly labeled on the device. For those products that do not have a DS1 identifier labeled on… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.1 |
||||
|
ds1AlarmAdmin
mandatory
Used to enable and disable the DS1 Alarm
Monitoring Application for this DS1 circuit. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.2 |
||||
|
ds1AlarmAutoRecovery
mandatory
Used to enable and disable the DS1 Alarm
Automatic Recovery feature for this DS1 circuit. For those devices that support ds1 alarm monitoring, but do not support the automatic recovery feature, this object always return… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.3 |
||||
|
ds1AlarmTrapEnable
mandatory
Used to enable and disable the DS1 Alarm
SNMP Trap generation feature for this DS1 circuit. This object operates in conjunction with configuration of objects in the ctron-trap-mib.txt |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.4 |
||||
|
ds1AlarmESCount
mandatory
Used in conjuction with ctDs1AlarmESInterval to set
the threshold for alarm generation when the number of Errored Seconds for a specified time interval, measured in minutes, is exceeded. The default Errored Seconds … |
Integer32r/w Constraints: range: 1-300 |
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.5 |
||||
|
ds1AlarmESInterval
mandatory
Used in conjuction with ctDs1AlarmESCount to set the
threshold for alarm generation when the number of Errored Seconds for a specified time interval, measured in minutes, is exceeded. The default Errored Seconds al… |
Integer32r/w Constraints: range: 1-15 |
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.6 |
||||
|
ds1AlarmBPVErrorRate
mandatory
Used to specify the negative exponent of 10, used in
monitoring Bipolar Violations (Code Violations for E1) over intervals defined by ds1AlarmBPVInterval. For example, for a ds1AlarmBPVErrorRate value of 6 used with … |
Integer32r/w Constraints: range: 5-9 |
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.7 |
||||
|
ds1AlarmBPVInterval
mandatory
Used to specify the interval, used in
monitoring Bipolar Violations (Code Violations for E1) with thresholds defined by ds1AlarmBPVErrorRate. For example, for a ds1AlarmBPVErrorRate value of 6 used with a ds1AlarmBPV… |
Integer32r/w Constraints: range: 1-15 |
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.8 |
||||
|
ds1AlarmManualRecovery
mandatory
To cause a manual recovery to occur, this object is set
to a 1. It is always read as a 1. The recovery will occur only when automatic recovery is disabled. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.7.1.6.2.1.9 |
.1.3.6.1.4.1.52.4.1.2.7.1.7.2
·
1 row entry
·
2 columns
Table containing IP addresses, used in an IP Priority Queue Forwarding function.
A description of a single entry.
Indexes
ipPQAddressId
| Column | Syntax | OID |
|---|---|---|
|
ipPQAddressId
mandatory
A unique value identifying an element in a sequence
of IP PQ address entries. |
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.52.4.1.2.7.1.7.2.1.1 |
|
ipPQIPAddress
mandatory
Returns an IP address associated with a specific
entry in this table. |
RFC1155-SMIIpAddress Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.52.4.1.2.7.1.7.2.1.2 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1
·
1 row entry
·
26 columns
HDSL 15 minute performance table. This table provides the
accumulated counts of errored seconds (ES) and unavailable
seconds (UAS) for the HDSL line including the local, remote
units and any doublers in between during a 15 minutes period
for the last 24 hours.
The table is indexed by the non-empty slot in the device and
the 15-minute history slot within the last 24 hours period.
Entries in the 15 minute performance table
Indexes
ctWanHDSLPerformance15mConnIndex ctWanHDSLPerformance15mSlotIndex
| Column | Syntax | OID |
|---|---|---|
|
ctWanHDSLPerformance15mConnIndex
mandatory
Identify the HDSL connection within the device, indexing from
1 to the maximum allowed number of HDSL connections in the device. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.1 |
|
ctWanHDSLPerformance15mSlotIndex
mandatory
Define which 15-minute slot history of the HDSL within the
24 hour period. Indexing from 1 - 97 with the first index representing the current 15-minute history |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.2 |
|
ctWanHDSLHLULoop1UAS15m
mandatory
Unavailable seconds (UAS) on LOOP 1 of the local line unit during
the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.3 |
|
ctWanHDSLHLULoop1ES15m
mandatory
Errored seconds (ES) on LOOP 1 of the local line unit during
the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.4 |
|
ctWanHDSLHLULoop2UAS15m
mandatory
Unavailable seconds (UAS) on LOOP 2 of the local line unit during
the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.5 |
|
ctWanHDSLHLULoop2ES15m
mandatory
Errored seconds (ES) on LOOP 2 of the local line unit during
the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.6 |
|
ctWanHDSLHRULoop1UAS15m
mandatory
Unavailable seconds (UAS) on LOOP 1 of the remote line unit during
the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.7 |
|
ctWanHDSLHRULoop1ES15m
mandatory
Errored seconds (ES) on LOOP 1 of the remote line unit during
the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.8 |
|
ctWanHDSLHRULoop2UAS15m
mandatory
Unavailable seconds (UAS) on LOOP 2 of the remote line unit during
the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.9 |
|
ctWanHDSLHRULoop2ES15m
mandatory
Errored seconds (ES) on LOOP 2 of the remote line unit during
the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.10 |
|
ctWanHDSLDb1NetworkLoop1UAS15m
mandatory
Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
network side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.11 |
|
ctWanHDSLDb1NetworkLoop1ES15m
mandatory
Errored seconds (ES) on LOOP 1 of the first doubler unit's
network side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.12 |
|
ctWanHDSLDb1NetworkLoop2UAS15m
mandatory
Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
network side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.13 |
|
ctWanHDSLDb1NetworkLoop2ES15m
mandatory
Errored seconds (ES) on LOOP 2 of the first doubler unit's
network side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.14 |
|
ctWanHDSLDb1CustomerLoop1UAS15m
mandatory
Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
customer side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.15 |
|
ctWanHDSLDb1CustomerLoop1ES15m
mandatory
Errored seconds (ES) on LOOP 1 of the first doubler unit's
customer side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.16 |
|
ctWanHDSLDb1CustomerLoop2UAS15m
mandatory
Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
customer side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.17 |
|
ctWanHDSLDb1CustomerLoop2ES15m
mandatory
Errored seconds (ES) on LOOP 2 of the first doubler unit's
customer side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.18 |
|
ctWanHDSLDb2NetworkLoop1UAS15m
mandatory
Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
network side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.19 |
|
ctWanHDSLDb2NetworkLoop1ES15m
mandatory
Errored seconds (ES) on LOOP 2 of the second doubler unit's
network side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.20 |
|
ctWanHDSLDb2NetworkLoop2UAS15m
mandatory
Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
network side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.21 |
|
ctWanHDSLDb2NetworkLoop2ES15m
mandatory
Errored seconds (ES) on LOOP 2 of the second doubler unit's
network side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.22 |
|
ctWanHDSLDb2CustomerLoop1UAS15m
mandatory
Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
customer side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.23 |
|
ctWanHDSLDb2CustomerLoop1ES15m
mandatory
Errored seconds (ES) on LOOP 1 of the second doubler unit's
customer side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.24 |
|
ctWanHDSLDb2CustomerLoop2UAS15m
mandatory
Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
customer side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.25 |
|
ctWanHDSLDb2CustomerLoop2ES15m
mandatory
Errored seconds (ES) on LOOP 2 of the second doubler unit's
customer side during the 15-minute period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.1.1.26 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2
·
1 row entry
·
26 columns
HDSL 24-hour performance table. This table provides the
accumulated counts of errored seconds (ES) and unavailable
seconds (UAS) for the HDSL line including the local, remote
units and any doublers in between during a 24-hour period
for the last 7 days.
The table is indexed by the non-empty slot in the device and
the 24-hour history slot within the last 7 days period.
Entries in the 24-hour ctWanHDSLPerformance table
Indexes
ctWanHDSLPerformance24hConnIndex ctWanHDSLPerformance24hSlotIndex
| Column | Syntax | OID |
|---|---|---|
|
ctWanHDSLPerformance24hConnIndex
mandatory
Identify the HDSL connection within the device, indexing from
1 to the maximum allowed number of HDSL connections in the device. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.1 |
|
ctWanHDSLPerformance24hSlotIndex
mandatory
Define which 24-hour slot history of the HDSL within the
last 7 days period. Indexing from 1 - 8 with the first index representing the current 24 hour history |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.2 |
|
ctWanHDSLHLULoop1UAS24h
mandatory
Unavailable seconds (UAS) on LOOP 1 of the local line unit during
the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.3 |
|
ctWanHDSLHLULoop1ES24h
mandatory
Errored seconds (ES) on LOOP 1 of the local line unit during
the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.4 |
|
ctWanHDSLHLULoop2UAS24h
mandatory
Unavailable seconds (UAS) on LOOP 2 of the local line unit during
the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.5 |
|
ctWanHDSLHLULoop2ES24h
mandatory
Errored seconds (ES) on LOOP 2 of the local line unit during
the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.6 |
|
ctWanHDSLHRULoop1UAS24h
mandatory
Unavailable seconds (UAS) on LOOP 1 of the remote line unit during
the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.7 |
|
ctWanHDSLHRULoop1ES24h
mandatory
Errored seconds (ES) on LOOP 1 of the remote line unit during
the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.8 |
|
ctWanHDSLHRULoop2UAS24h
mandatory
Unavailable seconds (UAS) on LOOP 2 of the remote line unit during
the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.9 |
|
ctWanHDSLHRULoop2ES24h
mandatory
Errored seconds (ES) on LOOP 2 of the remote line unit during
the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.10 |
|
ctWanHDSLDb1NetworkLoop1UAS24h
mandatory
Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
network side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.11 |
|
ctWanHDSLDb1NetworkLoop1ES24h
mandatory
Errored seconds (ES) on LOOP 1 of the first doubler unit's
network side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.12 |
|
ctWanHDSLDb1NetworkLoop2UAS24h
mandatory
Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
network side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.13 |
|
ctWanHDSLDb1NetworkLoop2ES24h
mandatory
Errored seconds (ES) on LOOP 2 of the first doubler unit's
network side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.14 |
|
ctWanHDSLDb1CustomerLoop1UAS24h
mandatory
Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
customer side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.15 |
|
ctWanHDSLDb1CustomerLoop1ES24h
mandatory
Errored seconds (ES) on LOOP 1 of the first doubler unit's
customer side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.16 |
|
ctWanHDSLDb1CustomerLoop2UAS24h
mandatory
Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
customer side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.17 |
|
ctWanHDSLDb1CustomerLoop2ES24h
mandatory
Errored seconds (ES) on LOOP 2 of the first doubler unit's
customer side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.18 |
|
ctWanHDSLDb2NetworkLoop1UAS24h
mandatory
Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
network side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.19 |
|
ctWanHDSLDb2NetworkLoop1ES24h
mandatory
Errored seconds (ES) on LOOP 1 of the second doubler unit's
network side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.20 |
|
ctWanHDSLDb2NetworkLoop2UAS24h
mandatory
Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
network side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.21 |
|
ctWanHDSLDb2NetworkLoop2ES24h
mandatory
Errored seconds (ES) on LOOP 2 of the second doubler unit's
network side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.22 |
|
ctWanHDSLDb2CustomerLoop1UAS24h
mandatory
Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
customer side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.23 |
|
ctWanHDSLDb2CustomerLoop1ES24h
mandatory
Errored seconds (ES) on LOOP 1 of the second doubler unit's
customer side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.24 |
|
ctWanHDSLDb2CustomerLoop2UAS24h
mandatory
Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
customer side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.25 |
|
ctWanHDSLDb2CustomerLoop2ES24h
mandatory
Errored seconds (ES) on LOOP 2 of the second doubler unit's
customer side during the 24-hour period. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.2.1.26 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3
·
1 row entry
·
51 columns
This table collects the statistics for the Signal noise ratio (SNR), and the pulse attenuation of the HDSL line, including the local, remote units and the doublers in between.
Entries of the HDSL statistics table
Indexes
ctWanHDSLStatisticsHLUConnIndex
| Column | Syntax | OID |
|---|---|---|
|
ctWanHDSLStatisticsHLUConnIndex
mandatory
Identify the HDSL connection occupied in the device,
indexing from 1 to the maximum allowed connections in the device. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.1 |
|
ctWanHDSLSNRHLULoop1
mandatory
Current SNR on LOOP 1 of the local line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.2 |
|
ctWanHDSLSNRLowHLULoop1
mandatory
Lowest SNR on LOOP 1 of the local line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.3 |
|
ctWanHDSLSNRHighHLULoop1
mandatory
Highest SNR on LOOP 1 of the local line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.4 |
|
ctWanHDSLSNRHLULoop2
mandatory
Current SNR on LOOP 2 of the local line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.5 |
|
ctWanHDSLSNRLowHLULoop2
mandatory
Lowest SNR on LOOP 2 of the local line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.6 |
|
ctWanHDSLSNRHighHLULoop2
mandatory
Highest SNR on LOOP 2 of the local line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.7 |
|
ctWanHDSLPulseAttenuationHLULoop1
mandatory
pulse Attenuation on LOOP 1 of the local line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.8 |
|
ctWanHDSLPulseAttenuationHLULoop2
mandatory
pulse Attenuation on LOOP 2 of the local line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.9 |
|
ctWanHDSLBitStat1HLU
mandatory
A byte value which contains product specific information:
bit 0 - System in AIS on the local line unit. 1 - System in AIS on the remote line unit. 2 - Channels are reversed on the remote line u… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.10 |
|
ctWanHDSLSNRHRULoop1
mandatory
Current SNR on LOOP 1 of the remote line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.11 |
|
ctWanHDSLSNRLowHRULoop1
mandatory
Lowest SNR on LOOP 1 of the remote line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.12 |
|
ctWanHDSLSNRHighHRULoop1
mandatory
Highest SNR on LOOP 1 of the remote line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.13 |
|
ctWanHDSLSNRHRULoop2
mandatory
Current SNR on LOOP 2 of the remote line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.14 |
|
ctWanHDSLSNRLowHRULoop2
mandatory
Lowest SNR on LOOP 2 of the remote line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.15 |
|
ctWanHDSLSNRHighHRULoop2
mandatory
Highest SNR on LOOP 2 of the remote line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.16 |
|
ctWanHDSLPulseAttenuationHRULoop1
mandatory
pulse Attenuation on LOOP 1 of the remote line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.17 |
|
ctWanHDSLPulseAttenuationHRULoop2
mandatory
pulse Attenuation on LOOP 2 of the remote line unit.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.18 |
|
ctWanHDSLDs1FrameHRU
mandatory
Byte value shows DS1 frame and code information for the remote
line unit (HiGain only): bit 0:1 - 0 - frame format is SF. 1 - frame format is ESF. 2 - Frame format is unframed. 3 - no act… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.19 |
|
ctWanHDSLSNRDb1NetworkLoop1
mandatory
Current SNR on LOOP 1 of doubler 1's network side
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.20 |
|
ctWanHDSLSNRLowDb1NetworkLoop1
mandatory
Lowest SNR on LOOP 1 of doubler 1's network side
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.21 |
|
ctWanHDSLSNRHighDb1NetworkLoop1
mandatory
Highest SNR on LOOP 1 of doubler 1's network side
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.22 |
|
ctWanHDSLSNRDb1NetworkLoop2
mandatory
Current SNR on LOOP 2 of doubler 1's network side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.23 |
|
ctWanHDSLSNRLowDb1NetworkLoop2
mandatory
Lowest SNR on LOOP 2 of doubler 1's network side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.24 |
|
ctWanHDSLSNRHighDb1NetworkLoop2
mandatory
Highest SNR on LOOP 2 of doubler 1's network side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.25 |
|
ctWanHDSLSNRDb1CustomerLoop1
mandatory
Current SNR on LOOP 1 of doubler 1's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.26 |
|
ctWanHDSLSNRLowDb1CustomerLoop1
mandatory
Lowest SNR on LOOP 1 of doubler 1's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.27 |
|
ctWanHDSLSNRHighDb1CustomerLoop1
mandatory
Highest SNR on LOOP 1 of doubler 1's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.28 |
|
ctWanHDSLSNRDb1CustomerLoop2
mandatory
Current SNR on LOOP 2 of doubler 1's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.29 |
|
ctWanHDSLSNRLowDb1CustomerLoop2
mandatory
Lowest SNR on LOOP 2 of doubler 1's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.30 |
|
ctWanHDSLSNRHighDb1CustomerLoop2
mandatory
Highest SNR on LOOP 2 of doubler 1's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.31 |
|
ctWanHDSLPulseAttenuationDb1NetworkLoop1
mandatory
Pulse Attenuation on LOOP 1 of doubler 1's network side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.32 |
|
ctWanHDSLPulseAttenuationDb1NetworkLoop2
mandatory
Pulse Attenuation on LOOP 2 of doubler 1's network side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.33 |
|
ctWanHDSLPulseAttenuationDb1CustomerLoop1
mandatory
Pulse Attenuation on LOOP 1 of doubler 1's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.34 |
|
ctWanHDSLPulseAttenuationDb1CustomerLoop2
mandatory
pulse Attenuation on LOOP 2 of doubler 1's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.35 |
|
ctWanHDSLSNRDb2NetworkLoop1
mandatory
Current SNR on LOOP 1 of doubler 2's network side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.36 |
|
ctWanHDSLSNRLowDb2NetworkLoop1
mandatory
Lowest SNR on LOOP 1 of doubler 2's network side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.37 |
|
ctWanHDSLSNRHighDb2NetworkLoop1
mandatory
Highest SNR on LOOP 1 of doubler 2's network side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.38 |
|
ctWanHDSLSNRDb2NetworkLoop2
mandatory
Current SNR on LOOP 2 of doubler 2's network side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.39 |
|
ctWanHDSLSNRLowDb2NetworkLoop2
mandatory
Lowest SNR on LOOP 2 of doubler 2's network side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.40 |
|
ctWanHDSLSNRHighDb2NetworkLoop2
mandatory
Highest SNR on LOOP 2 of doubler 2's network side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.41 |
|
ctWanHDSLSNRDb2CustomerLoop1
mandatory
Current SNR on LOOP 1 of doubler 2's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.42 |
|
ctWanHDSLSNRLowDb2CustomerLoop1
mandatory
Lowest SNR on LOOP 1 of doubler 2's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.43 |
|
ctWanHDSLSNRHighDb2CustomerLoop1
mandatory
Highest SNR on LOOP 1 of doubler 2's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.44 |
|
ctWanHDSLSNRDb2CustomerLoop2
mandatory
Current SNR on LOOP 2 of doubler 2's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.45 |
|
ctWanHDSLSNRLowDb2CustomerLoop2
mandatory
Lowest SNR on LOOP 2 of doubler 2's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.46 |
|
ctWanHDSLSNRHighDb2CustomerLoop2
mandatory
Highest SNR on LOOP 2 of doubler 2's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.47 |
|
ctWanHDSLPulseAttenuationDb2NetworkLoop1
mandatory
Pulse Attenuation on LOOP 1 of doubler 2's network side
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.48 |
|
ctWanHDSLPulseAttenuationDb2NetworkLoop2
mandatory
Pulse Attenuation on LOOP 2 of doubler 2's network side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.49 |
|
ctWanHDSLPulseAttenuationDb2CustomerLoop1
mandatory
pulse Attenuation on LOOP 1 of doubler 2's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.50 |
|
ctWanHDSLPulseAttenuationDb2CustomerLoop2
mandatory
Pulse Attenuation on LOOP 2 of doubler 2's customer side.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.3.1.51 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.4
·
1 row entry
·
4 columns
Test result for the HDSL line, the current test results only apply to the local line unit.
Entries of the HDSL test results table.
Indexes
ctWanHDSLTestHLUConnIndex
| Column | Syntax | OID |
|---|---|---|
|
ctWanHDSLTestHLUConnIndex
mandatory
Identify the slot of the HDSL within the device that the user
wants to conduct the line unit test. Slot number start from 1 to maximum slots available in the device. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.4.1.1 |
|
ctWanHDSLTestMode
mandatory
This object may only be successfully set on a master device.
When this object is set, the local unit's test mode is defined by these values when set: 1 - Normal operation 3 - Self test mode 4 - P… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.4.1.2 |
|
ctWanHDSLHLUTestResult
mandatory
Test result for the local line unit (1 - test failed, 0 - success):
bit 0 - 2180 DS1 frame sync test (HiGain only) 1 - 2180 DS1 data test (HiGain only) 2 - LIU DS1 frame sync test (HiGain only) 3 - LIU DS1 d… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.4.1.3 |
|
ctWanHDSLHRUTestResult
mandatory
Test results for the remote line unit,
Bit definitions correspond to those defined for ctWanHDSLHLUTestResult. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.4.1.4 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.5
·
1 row entry
·
3 columns
This table collects the existing alarms information for the HDSL line, including the local, remote line units and the doublers.
Entries for the ctWanHDSL alarms information
Indexes
ctWanHDSLAlarmsHLUConnIndex
| Column | Syntax | OID |
|---|---|---|
|
ctWanHDSLAlarmsHLUConnIndex
mandatory
Identify which HDSL connection within the device that
the user wants to retrieve the alarm information. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.5.1.1 |
|
ctWanHDSLAlarmsBackplane
mandatory
Specific information that's related to the HDSL alarms, each bit
in the two bytes value has the following meaning if set: Bit 0 : Local Loss of Signal on DS1 line (HiGain only). 1 : Remote Loss of Si… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.5.1.2 |
|
ctWanHDSLAlarmsES
mandatory
A two bytes value for the Errored Second indication of the HDSL
line unit, including local, remote line units and the doublers. each bit in the two bytes value has the following meaning if set: Bit 0 : … |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.5.1.3 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6
·
1 row entry
·
35 columns
HDSL Alarm History table. This table provides the accumulated
counts of Errored Seconds (ES) and Loss of Sync words (LOS)
as well as the time stamp of the above events occurred for both
of the HDSL loops.
The time stamps show the date in MMDDYYYYHHMM format.
Entries in the Alarm History table
Indexes
ctWanHDSLAlarmHistoryConnIndex
| Column | Syntax | OID |
|---|---|---|
|
ctWanHDSLAlarmHistoryConnIndex
mandatory
Defines which HDSL connection's alarm history within the
device. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.1 |
|
ctWanHDSLAlHistLLOSFirst
mandatory
Time stamp of the first time the DS1 Loss Of Signal (LOS)
occurred on the local side of the HDSL. |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.2 |
|
ctWanHDSLAlHistLLOSLast
mandatory
Time stamp of the last time the DS1 Loss Of Signal (LOS)
occurred on the local side of the HDSL. |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.3 |
|
ctWanHDSLAlHistLLOSCurrent
mandatory
Set if the DS1 Loss Of Signal (LOS) still occurred on the
local side of the HDSL. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.4 |
|
ctWanHDSLAlHistLLOSCount
mandatory
Number of times the DS1 Loss Of Signal (LOS) occurred since
we last cleared the alarm history on the local side of the HDSL. (HiGain only) |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.5 |
|
ctWanHDSLAlHistRLOSFirst
mandatory
Time stamp of the first time the DS1 Loss Of Signal (LOS)
occurred on the remote side of the HDSL. (HiGain only) |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.6 |
|
ctWanHDSLAlHistRLOSLast
mandatory
Time stamp of the last time the DS1 Loss Of Signal (LOS) occurred
on the remote side of the HDSL. (HiGain only) |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.7 |
|
ctWanHDSLAlHistRLOSCurrent
mandatory
Set if the DS1 Loss Of Signal (LOS) still occurred on the remote
site of the HDSL. (HiGain only) |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.8 |
|
ctWanHDSLAlHistRLOSCount
mandatory
Number of times the DS1 Loss Of Signal (LOS) occurred since we
last cleared the alarm history on the remote site of the HDSL. (HiGain only) |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.9 |
|
ctWanHDSLAlHistLOSW1First
mandatory
Time stamp of the first time the Loss Of Sync Word (LOSW) occurred
on the LOOP 1 of the HDSL link. |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.10 |
|
ctWanHDSLAlHistLOSW1Last
mandatory
Time stamp of the last time the Loss Of Sync Word (LOSW) occurred
on the LOOP 1 of the HDSL link. |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.11 |
|
ctWanHDSLAlHistLOSW1Current
mandatory
Set if the Loss Of Sync Word (LOSW) still occurred on the LOOP 1
of the HDSL link. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.12 |
|
ctWanHDSLAlHistLOSW1Count
mandatory
Number of times the Loss Of Sync Word (LOSW) occurred since we
last cleared the history on the LOOP 1 of the HDSL link. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.13 |
|
ctWanHDSLAlHistLOSW2First
mandatory
Time stamp of the first time the Loss Of Sync Word (LOSW) occurred
on the LOOP 2 of the HDSL link. |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.14 |
|
ctWanHDSLAlHistLOSW2Last
mandatory
Time stamp of the last time the Loss Of Sync Word (LOSW) occurred
on the LOOP 2 of the HDSL link. |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.15 |
|
ctWanHDSLAlHistLOSW2Current
mandatory
Set if the Loss Of Sync Word (LOSW) still occurred on the LOOP 2
of the HDSL link. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.16 |
|
ctWanHDSLAlHistLOSW2Count
mandatory
Number of times the Loss Of Sync Word (LOSW) occurred since we
last cleared the history on the LOOP 2 of the HDSL link. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.17 |
|
ctWanHDSLAlHistES1First
mandatory
Time stamp of the first time the Errored Seconds (ES) occurred
on the LOOP 1 of the HDSL link. |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.18 |
|
ctWanHDSLAlHistES1Last
mandatory
Time stamp of the last time the Errored Seconds (ES) occurred
on the LOOP 1 of the HDSL link. |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.19 |
|
ctWanHDSLAlHistES1Current
mandatory
Set if the Errored Seconds (ES) still occurred on the LOOP 1 of
the HDSL link. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.20 |
|
ctWanHDSLAlHistES1Count
mandatory
Number of times the Errored Seconds (ES) occurred since we last
cleared the alarm history on the LOOP 1 of the HDSL link. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.21 |
|
ctWanHDSLAlHistES2First
mandatory
Time stamp of the first time the Errored Seconds (ES) occurred
on the LOOP 2 of the HDSL link. |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.22 |
|
ctWanHDSLAlHistES2Last
mandatory
Time stamp of the last time the Errored Seconds (ES) occurred
on the LOOP 2 of the HDSL link. |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.23 |
|
ctWanHDSLAlHistES2Current
mandatory
Set if the Errored Seconds (ES) still occurred on the LOOP 2 of
the HDSL link. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.24 |
|
ctWanHDSLAlHistES2Count
mandatory
Number of times the Errored Seconds (ES) occurred since we last
cleared the history on the LOOP 2 of the HDSL link. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.25 |
|
ctWanHDSLAlHistMargin1First
mandatory
Time stamp of the first time the alarms exceeded the
Margin Threshold on LOOP 1 of the HDSL link. |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.26 |
|
ctWanHDSLAlHistMargin1Last
mandatory
Time stamp of the last time the alarms exceeded the Margin
Threshold on the LOOP 1 of the HDSL link. |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.27 |
|
ctWanHDSLAlHistMargin1Current
mandatory
Set if the alarms still exceeded the Margin Threshold
on the LOOP 1 of the HDSL link. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.28 |
|
ctWanHDSLAlHistMargin1Count
mandatory
Number of times the alarm exceeded the Margin Threshold since
we last cleared the alarm history on the LOOP 1 of the HDSL link. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.29 |
|
ctWanHDSLAlHistMargin2First
mandatory
Time stamp of the first time the alarms exceeded the Margin
Threshold on LOOP 2 of the HDSL link. |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.30 |
|
ctWanHDSLAlHistMargin2Last
mandatory
Time stamp of the last time the alarms exceeded the Margin
Threshold on the LOOP 2 of the HDSL link. |
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.31 |
|
ctWanHDSLAlHistMargin2Current
mandatory
Set if the alarms still exceeded the Margin Threshold
on the LOOP 2 of the HDSL link. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.32 |
|
ctWanHDSLAlHistMargin2Count
mandatory
Number of times the alarm exceeded the Margin Threshold since
we last cleared the alarm history on the LOOP 2 of the HDSL link. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.33 |
|
ctWanHDSLAlHistCleared
mandatory
Time stamp of the time user requested to clear the alarm history.
|
OctetString Constraints: range: 12-12 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.34 |
|
ctWanHDSLAlHistClearit
mandatory
set to a 1 to clear the alarm history.
A read of this value always returns a 1. NOTE: the setting of this object also causes the SNR low value, SNR high value, and the performance history to be reset. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.35 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.7
·
1 row entry
·
3 columns
HDSL Loopback table. This table provides the certain loopback settings for the HDSL link.
Entries in the HDSL Loopback table.
Indexes
ctWanHDSLLoopbacksHLUConnIndex
| Column | Syntax | OID |
|---|---|---|
|
ctWanHDSLLoopbacksHLUConnIndex
mandatory
Identify the HDSL connection within the device
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.7.1.1 |
|
ctWanHDSLLoopbacksAdminType
mandatory
This is the requested loopback type for the HDSL.
loopbacks setting: 1 : Smartjack - loopback to network at remote line unit. 2 : Loopback to network at local line unit. 3 : Loopback to netw… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.7.1.2 |
|
ctWanHDSLLoopbacksOperType
mandatory
This is the operational loopback type for the HDSL.
loopbacks setting: 1 : Smartjack - loopback to network at remote line unit. 2 : Loopback to network at local line unit. 3 : Loopback to ne… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.7.1.8.7.1.3 |