CISCO-OPTICAL-MONITOR-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
37
.1.3.6.1.4.1.9.9.264.1.1.1 · 1 row entry · 19 columns
This table provides objects to monitor optical
parameters in a network element. It also provides
objects for setting high and low threshold levels, with
configurable severities, on these monitored parameters.
cOpticalMonEntry entry .1.3.6.1.4.1.9.9.264.1.1.1.1
An entry in the cOpticalMonTable provides objects to
monitor an optical parameter and set threshold levels
on that parameter, at an optical interface.

Note that the set of monitored optical parameters may v…
Indexes
IF-MIBifIndex cOpticalMonDirection cOpticalMonLocation cOpticalMonParameterType
Column Syntax OID
cOpticalMonDirection
This object indicates the direction monitored for the
optical interface, in this entry.
OpticalIfDirection
Textual Convention: OpticalIfDirection Enumeration
Type Values:
1receive
2transmit
3notApplicable
.1.3.6.1.4.1.9.9.264.1.1.1.1.1
cOpticalMonLocation
This object indicates whether the optical characteristics are
measured before or after adjustment (e.g. optical amplification
or attenuation), at this interface.
OpticalIfMonLocation
Textual Convention: OpticalIfMonLocation Enumeration
Type Values:
1beforeAdjustment
2afterAdjustment
3notApplicable
.1.3.6.1.4.1.9.9.264.1.1.1.1.2
cOpticalMonParameterType
This object specifies the optical parameter that is being
monitored in this entry.
OpticalParameterType
Textual Convention: OpticalParameterType Enumeration
Type Values:
1power
2acPower
3ambientTemp
4laserTemp
5biasCurrent
6peltierCurrent
7xcvrVoltage
.1.3.6.1.4.1.9.9.264.1.1.1.1.3
cOpticalParameterValue
This object gives the value measured for the particular
optical parameter specified by the cOpticalMonParameterType
object.
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.1.1.1.4
cOpticalParamHighAlarmThresh
This object is used to set a high alarm threshold on the
optical parameter being monitored.

An alarm condition will be raised if the value given by
cOpticalParameterValue goes from below the value configu…
OpticalParameterValuer/w
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.1.1.1.5
cOpticalParamHighAlarmSev
This object is used to specify a severity level associated
with the high alarm threshold given by the
cOpticalParamHighAlarmThresh object. The values 'notAlarmed',
'notReported', and 'cleared' do not apply.
OpticalAlarmSeverityr/w
Textual Convention: OpticalAlarmSeverity Enumeration
Type Values:
1critical
2major
3minor
4notAlarmed
5notReported
6cleared
.1.3.6.1.4.1.9.9.264.1.1.1.1.6
cOpticalParamHighWarningThresh
This object is used to set a high warning threshold on
the optical parameter being monitored.

A threshold crossing condition will be indicated if the value
given by cOpticalParameterValue goes from below …
OpticalParameterValuer/w
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.1.1.1.7
cOpticalParamHighWarningSev
This object is used to specify a severity level associated
with the high warning threshold given by the
cOpticalParamHighWarningThresh object. The values 'critical',
'major', and 'cleared' do not apply.

T…
OpticalAlarmSeverityr/w
Textual Convention: OpticalAlarmSeverity Enumeration
Type Values:
1critical
2major
3minor
4notAlarmed
5notReported
6cleared
.1.3.6.1.4.1.9.9.264.1.1.1.1.8
cOpticalParamLowAlarmThresh
This object is used to set a low alarm threshold on the
optical parameter being monitored.

An alarm condition will be raised if the value given by
cOpticalParameterValue goes from above the value configur…
OpticalParameterValuer/w
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.1.1.1.9
cOpticalParamLowAlarmSev
This object is used to specify a severity level associated
with the low alarm threshold given by the
cOpticalParamLowAlarmThresh object. The values 'notAlarmed',
'notReported', and 'cleared' do not apply.
OpticalAlarmSeverityr/w
Textual Convention: OpticalAlarmSeverity Enumeration
Type Values:
1critical
2major
3minor
4notAlarmed
5notReported
6cleared
.1.3.6.1.4.1.9.9.264.1.1.1.1.10
cOpticalParamLowWarningThresh
This object is used to set a low warning threshold on
the optical parameter being monitored.

A threshold crossing condition will be indicated if the value
given by cOpticalParameterValue goes from above t…
OpticalParameterValuer/w
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.1.1.1.11
cOpticalParamLowWarningSev
This object is used to specify a severity level associated
with the low warning threshold given by the
cOpticalParamLowWarningThresh object. The values 'critical',
'major', and 'cleared' do not apply.

The…
OpticalAlarmSeverityr/w
Textual Convention: OpticalAlarmSeverity Enumeration
Type Values:
1critical
2major
3minor
4notAlarmed
5notReported
6cleared
.1.3.6.1.4.1.9.9.264.1.1.1.1.12
cOpticalParamAlarmStatus
This object is used to indicate the current status of
the thresholds for the monitored optical parameter
on the interface.

If a threshold is currently being exceeded on the
interface, the corresponding bi…
OpticalAlarmStatus
Textual Convention: OpticalAlarmStatus OctetString
Type Constraints:
range: 1
.1.3.6.1.4.1.9.9.264.1.1.1.1.13
cOpticalParamAlarmCurMaxThresh
This object indicates the threshold value of the highest
severity threshold that is currently being exceeded
on the interface, for the optical parameter.
If no threshold value is currently being
exceeded, then the value…
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.1.1.1.14
cOpticalParamAlarmCurMaxSev
This object indicates the maximum severity of any thresholds
that are currently being exceeded on the interface, for the
optical parameter.
OpticalAlarmSeverity
Textual Convention: OpticalAlarmSeverity Enumeration
Type Values:
1critical
2major
3minor
4notAlarmed
5notReported
6cleared
.1.3.6.1.4.1.9.9.264.1.1.1.1.15
cOpticalParamAlarmLastChange
This object specifies the value of sysUpTime at the last time
a threshold related to a particular optical parameter was
exceeded or cleared on the interface.
SNMPv2-TCTimeStamp
Textual Convention: SNMPv2-TCTimeStamp Unsigned32
.1.3.6.1.4.1.9.9.264.1.1.1.1.16
cOpticalMon15MinValidIntervals
This object gives the number of previous 15 minute
intervals for which valid performance monitoring data
has been stored on the interface.

The value of this object will be n (where n is the maximum
number…
Unsigned32
Constraints:
range: 0-96
.1.3.6.1.4.1.9.9.264.1.1.1.1.17
cOpticalMon24HrValidIntervals
This object gives the number of previous 24 hour
intervals for which valid performance monitoring data
has been stored on the interface.

The value of this object will be 0 if the measurement
was (re-)star…
Unsigned32
Constraints:
range: 0-1
.1.3.6.1.4.1.9.9.264.1.1.1.1.18
cOpticalParamThreshSource
This object indicates if the current value of a particular
threshold in this entry is user configured value or it is
a system default value. It also allows user to specify
the list of thresholds for this entry which s…
Bitsr/w
Enumerated Values:
0highAlarmDefThresh
1highWarnDefThresh
2lowAlarmDefThresh
3lowWarnDefThresh
.1.3.6.1.4.1.9.9.264.1.1.1.1.19
.1.3.6.1.4.1.9.9.264.1.1.5 · 1 row entry · 1 columns
This table contains the list of optical interfaces
populated in cOpticalMonTable.
cOpticalMonIfEntry entry .1.3.6.1.4.1.9.9.264.1.1.5.1
An entry containing the information for a particular optical interface.
Indexes
IF-MIBifIndex
Column Syntax OID
cOpticalMonIfTimeInSlot
This object indicates when this optical transceiver was detected by the
system.
secondsSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.264.1.1.5.1.1
.1.3.6.1.4.1.9.9.264.1.2.1 · 1 row entry · 8 columns
This table contains performance monitoring data for the
various optical parameters, collected over the current 15
minute or the current 24 hour interval.
cOpticalPMCurrentEntry entry .1.3.6.1.4.1.9.9.264.1.2.1.1
An entry in the cOpticalPMCurrentTable. It contains
performance monitoring data for a monitored optical
parameter at an interface, collected over the current 15
minute or the current 24 hour interval.

Note …
Indexes
cOpticalPMCurrentPeriod IF-MIBifIndex cOpticalPMCurrentDirection cOpticalPMCurrentLocation cOpticalPMCurrentParamType
Column Syntax OID
cOpticalPMCurrentPeriod
This object indicates whether the optical parameter values
given in this entry are collected over the current 15 minute or
the current 24 hour interval.
OpticalPMPeriod
Textual Convention: OpticalPMPeriod Enumeration
Type Values:
1fifteenMin
2twentyFourHour
.1.3.6.1.4.1.9.9.264.1.2.1.1.1
cOpticalPMCurrentDirection
This object indicates the direction monitored for the optical
interface, in this entry.
OpticalIfDirection
Textual Convention: OpticalIfDirection Enumeration
Type Values:
1receive
2transmit
3notApplicable
.1.3.6.1.4.1.9.9.264.1.2.1.1.2
cOpticalPMCurrentLocation
This object indicates whether the optical characteristics are
measured before or after adjustment (e.g. optical amplification
or attenuation), at this interface.
OpticalIfMonLocation
Textual Convention: OpticalIfMonLocation Enumeration
Type Values:
1beforeAdjustment
2afterAdjustment
3notApplicable
.1.3.6.1.4.1.9.9.264.1.2.1.1.3
cOpticalPMCurrentParamType
This object specifies the optical parameter that is being
monitored, in this entry.
OpticalParameterType
Textual Convention: OpticalParameterType Enumeration
Type Values:
1power
2acPower
3ambientTemp
4laserTemp
5biasCurrent
6peltierCurrent
7xcvrVoltage
.1.3.6.1.4.1.9.9.264.1.2.1.1.4
cOpticalPMCurrentMaxParam
This object gives the maximum value measured for the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.2.1.1.5
cOpticalPMCurrentMinParam
This object gives the minimum value measured for the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.2.1.1.6
cOpticalPMCurrentMeanParam
This object gives the average value of the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.2.1.1.7
cOpticalPMCurrentUnavailSecs
This object is used to indicate the number of seconds,
in the current 15 minute or the current 24 hour interval, for
which the optical performance data is not accounted for.

In the receive direction, the …
Integer32
Constraints:
range: 0-86400
.1.3.6.1.4.1.9.9.264.1.2.1.1.8
.1.3.6.1.4.1.9.9.264.1.2.2 · 1 row entry · 9 columns
This table stores performance monitoring data for the
various optical parameters, collected over previous
intervals.
          
This table can have entries for one complete 24 hour
interval and up to 96 complete 15 minute
intervals. A system is required to store at least
4 completed 15 minute intervals. The number of valid
15 minute intervals in this table is indicated by the
cOpticalMon15MinValidIntervals object and the number of
valid 24 hour intervals is indicated by the
cOpticalMon24HrValidIntervals object.
cOpticalPMIntervalEntry entry .1.3.6.1.4.1.9.9.264.1.2.2.1
An entry in the cOpticalPMIntervalTable. It contains
performance monitoring data for an optical parameter,
collected over a previous interval.

Note that the set of monitored optical parameters may vary
base…
Indexes
cOpticalPMIntervalPeriod cOpticalPMIntervalNumber IF-MIBifIndex cOpticalPMIntervalDirection cOpticalPMIntervalLocation cOpticalPMIntervalParamType
Column Syntax OID
cOpticalPMIntervalPeriod
This object indicates whether the optical parameter values,
given in this entry, are collected over a period of 15 minutes
or 24 hours.
OpticalPMPeriod
Textual Convention: OpticalPMPeriod Enumeration
Type Values:
1fifteenMin
2twentyFourHour
.1.3.6.1.4.1.9.9.264.1.2.2.1.1
cOpticalPMIntervalNumber
A number between 1 and 96, which identifies the
interval for which the set of optical parameter values is
available. The interval identified by 1 is the most recently
completed 15 minute or 24 hour interval, and the int…
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.9.9.264.1.2.2.1.2
cOpticalPMIntervalDirection
This object indicates the direction monitored for the optical
interface, in this entry.
OpticalIfDirection
Textual Convention: OpticalIfDirection Enumeration
Type Values:
1receive
2transmit
3notApplicable
.1.3.6.1.4.1.9.9.264.1.2.2.1.3
cOpticalPMIntervalLocation
This object indicates whether the optical characteristics
are measured before or after adjustment (e.g.
optical amplification or attenuation), at this interface.
OpticalIfMonLocation
Textual Convention: OpticalIfMonLocation Enumeration
Type Values:
1beforeAdjustment
2afterAdjustment
3notApplicable
.1.3.6.1.4.1.9.9.264.1.2.2.1.4
cOpticalPMIntervalParamType
This object specifies the optical parameter that is being
monitored, in this entry.
OpticalParameterType
Textual Convention: OpticalParameterType Enumeration
Type Values:
1power
2acPower
3ambientTemp
4laserTemp
5biasCurrent
6peltierCurrent
7xcvrVoltage
.1.3.6.1.4.1.9.9.264.1.2.2.1.5
cOpticalPMIntervalMaxParam
This object gives the maximum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval.
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.2.2.1.6
cOpticalPMIntervalMinParam
This object gives the minimum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval.
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.2.2.1.7
cOpticalPMIntervalMeanParam
This object gives the average value of the measured optical
parameter, in a particular 15 minute or 24 hour interval.
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.2.2.1.8
cOpticalPMIntervalUnavailSecs
This object is used to indicate the number of seconds,
in the particular 15 minute or 24 hour interval, for which the
optical performance data is not accounted for.

In the receive direction, the performan…
Integer32
Constraints:
range: 0-86400