cOpticalPMCurrentParamType
CISCO-OPTICAL-MONITOR-MIB ·
.1.3.6.1.4.1.9.9.264.1.2.1.1.4
Object
column
OpticalParameterType
This object specifies the optical parameter that is being monitored, in this entry.
Context
- MIB
- CISCO-OPTICAL-MONITOR-MIB
- OID
.1.3.6.1.4.1.9.9.264.1.2.1.1.4- Type
- column
- Access
- noaccess
- Status
- current
- Parent
- cOpticalPMCurrentEntry
- Table
- cOpticalPMCurrentTable
- Siblings
- 7
Syntax
OpticalParameterType
- Source
- OpticalParameterType
- Base type
Enumeration
Values & Constraints
Type Values
1 | power |
2 | acPower |
3 | ambientTemp |
4 | laserTemp |
5 | biasCurrent |
6 | peltierCurrent |
7 | xcvrVoltage |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cOpticalPMCurrentPeriod This object indicates whether the optical parameter values
given in this entry are collected over the current 15 minute or
the current 24 hour interval. | column | OpticalPMPeriod | .1.3.6.1.4.1.9.9.264.1.2.1.1.1 |
| cOpticalPMCurrentDirection This object indicates the direction monitored for the optical
interface, in this entry. | column | OpticalIfDirection | .1.3.6.1.4.1.9.9.264.1.2.1.1.2 |
| cOpticalPMCurrentLocation This object indicates whether the optical characteristics are
measured before or after adjustment (e.g. optical amplification
or attenuation), at this interface. | column | OpticalIfMonLocation | .1.3.6.1.4.1.9.9.264.1.2.1.1.3 |
| cOpticalPMCurrentMaxParam This object gives the maximum value measured for the monitored
optical parameter, in the current 15 minute or the current
24 hour interval. | column | OpticalParameterValue | .1.3.6.1.4.1.9.9.264.1.2.1.1.5 |
| cOpticalPMCurrentMinParam This object gives the minimum value measured for the monitored
optical parameter, in the current 15 minute or the current
24 hour interval. | column | OpticalParameterValue | .1.3.6.1.4.1.9.9.264.1.2.1.1.6 |
| cOpticalPMCurrentMeanParam This object gives the average value of the monitored
optical parameter, in the current 15 minute or the current
24 hour interval. | column | OpticalParameterValue | .1.3.6.1.4.1.9.9.264.1.2.1.1.7 |
| cOpticalPMCurrentUnavailSecs This object is used to indicate the number of seconds,
in the current 15 minute or the current 24 hour interval, for
which the optical performance data is not accounted for.
… | column | Integer32 | .1.3.6.1.4.1.9.9.264.1.2.1.1.8 |