cOpticalMonTable
table.1.3.6.1.4.1.3607.2.30.1.1
·
1 row entry
·
11 columns
This table provides objects to monitor optical parameters in a network element. It also provides objects for setting high and low threshold levels, with configurable severities, on these monitored parameters.
An entry in the cOpticalMonTable provides objects to
monitor an optical parameter and set threshold levels
on that parameter, at an optical interface.
Note that the set of monitored optical parameters may v…
monitor an optical parameter and set threshold levels
on that parameter, at an optical interface.
Note that the set of monitored optical parameters may v…
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
cOpticalMonDirection
This object is an index into the cOpticalMonTable
and indicates the direction monitored for the optical interface, in this entry. |
OpticalIfDirection Textual Convention: OpticalIfDirection EnumerationType Values:
|
.1.3.6.1.4.1.3607.2.30.1.1.1.1 |
||||||||||||||||||||||
|
cOpticalMonParameterType
This object is an index into the cOpticalMonTable
and specifies the optical parameter that is being monitored, in this entry. |
OpticalParameterType Textual Convention: OpticalParameterType EnumerationType Values:
|
.1.3.6.1.4.1.3607.2.30.1.1.1.2 |
||||||||||||||||||||||
|
cOpticalParameterValue
This object gives the value measured for the particular
optical parameter specified by the cOpticalMonParameterType object. |
OpticalParameterValue Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.1.1.1.3 |
||||||||||||||||||||||
|
cOpticalParamHighAlarmThresh
This object is used to set a high alarm threshold on the
optical parameter being monitored. If the measured value of the parameter,is greater than the value configured in this object, an alarm will be r… |
OpticalParameterValuer/w Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.1.1.1.4 |
||||||||||||||||||||||
|
cOpticalParamHighWarning15MinThresh
This object is used to set a high warning 15 minute threshold
on the optical parameter being monitored. If the measured value of the parameter,is greater than the value configured in this object, an al… |
OpticalParameterValuer/w Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.1.1.1.5 |
||||||||||||||||||||||
|
cOpticalParamHighWarning1DayThresh
This object is used to set a high warning 1 day threshold on
the optical parameter being monitored. If the measured value of the parameter,is greater than the value configured in this object, an alarm … |
OpticalParameterValuer/w Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.1.1.1.6 |
||||||||||||||||||||||
|
cOpticalParamLowAlarmThresh
This object is used to set a low alarm threshold on the
optical parameter being monitored. If the measured value of the parameter,goes lower than the value configured in this object, an alarm will be ra… |
OpticalParameterValuer/w Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.1.1.1.7 |
||||||||||||||||||||||
|
cOpticalParamLowWarning15MinThresh
This object is used to set a low warning 15 minute threshold
on the optical parameter being monitored. If the measured value of the parameter,goes lower than the value configured in this object, an alar… |
OpticalParameterValuer/w Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.1.1.1.8 |
||||||||||||||||||||||
|
cOpticalParamLowWarning1DayThresh
This object is used to set a low warning 1 day threshold
on the optical parameter being monitored. If the measured value of the parameter,goes lower than the value configured in this object, an alarm w… |
OpticalParameterValuer/w Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.1.1.1.9 |
||||||||||||||||||||||
|
cOpticalParamLowDegradeThresh
This object is used to set a low degrade threshold
on the optical parameter being monitored. If the measured value of the parameter,goes lower than the value configured in this object, a degrade alarm … |
OpticalParameterValuer/w Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.1.1.1.10 |
||||||||||||||||||||||
|
cOpticalParamHighDegradeThresh
This object is used to set a high degrade threshold
on the optical parameter being monitored. If the measured value of the parameter,goes lower than the value configured in this object, a degrade alarm… |
OpticalParameterValuer/w Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.1.1.1.11 |
cOpticalPMCurrentTable
table.1.3.6.1.4.1.3607.2.30.2.1
·
1 row entry
·
6 columns
This table stores performance monitoring data for the various optical parameters, collected over the current interval.
An entry in the cOpticalPMCurrentTable. It contains
performance monitoring data for an optical parameter,
collected over the current interval.
Note that the set of monitored optical parameters may vary
base…
performance monitoring data for an optical parameter,
collected over the current interval.
Note that the set of monitored optical parameters may vary
base…
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
cOpticalPMCurrentDirection
This object is an index into the cOpticalPMCurrentTable
and indicates the direction monitored for the optical interface, in this entry. |
OpticalIfDirection Textual Convention: OpticalIfDirection EnumerationType Values:
|
.1.3.6.1.4.1.3607.2.30.2.1.1.1 |
||||||||||||||||||||||
|
cOpticalPMCurrentParamType
This object is an index into the
cOpticalPMCurrentTable and specifies the optical parameter that is being monitored, in this entry. |
OpticalParameterType Textual Convention: OpticalParameterType EnumerationType Values:
|
.1.3.6.1.4.1.3607.2.30.2.1.1.2 |
||||||||||||||||||||||
|
cOpticalPMCurrentPeriod
This object is an index into the
cOpticalPMCurrentTable and indicates whether the optical parameter values given in this entry, are collected over a period of 15 minutes or 24 hours. |
CERENT-TCCerentPeriod Textual Convention: CERENT-TCCerentPeriod EnumerationType Values:
|
.1.3.6.1.4.1.3607.2.30.2.1.1.3 |
||||||||||||||||||||||
|
cOpticalPMCurrentMaxParam
This object gives the maximum value measured for the optical
parameter, in the current 15 minute or 24 hour interval. |
OpticalParameterValue Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.2.1.1.4 |
||||||||||||||||||||||
|
cOpticalPMCurrentMinParam
This object gives the minimum value measured for the optical
parameter, in the current 15 minute or 24 hour interval. |
OpticalParameterValue Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.2.1.1.5 |
||||||||||||||||||||||
|
cOpticalPMCurrentMeanParam
This object gives the average value of the measured optical
parameter, in the current 15 minute or 24 hour interval. |
OpticalParameterValue Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.2.1.1.6 |
cOpticalPMIntervalTable
table.1.3.6.1.4.1.3607.2.30.2.2
·
1 row entry
·
8 columns
This table stores performance monitoring data for the
various optical parameters, collected over current and
previous intervals.
This table can have entries for up to 96 complete 15 minute
intervals.
An entry in the cOpticalPMIntervalTable. It contains
performance monitoring data for an optical parameter,
collected over current and previous intervals.
Note that the set of monitored optical parameters ma…
performance monitoring data for an optical parameter,
collected over current and previous intervals.
Note that the set of monitored optical parameters ma…
Indexes
IF-MIBifIndex cOpticalPMIntervalDirection cOpticalPMIntervalParamType cOpticalPMIntervalPeriod cOpticalPMIntervalNumber
| Column | Syntax | OID | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
cOpticalPMIntervalDirection
This object is an index into the cOpticalPMIntervalTable
and indicates the direction monitored for the optical interface, in this entry. |
OpticalIfDirection Textual Convention: OpticalIfDirection EnumerationType Values:
|
.1.3.6.1.4.1.3607.2.30.2.2.1.1 |
||||||||||||||||||||||
|
cOpticalPMIntervalParamType
This object is an index into the
cOpticalPMIntervalTable and specifies the optical parameter that is being monitored, in this entry. |
OpticalParameterType Textual Convention: OpticalParameterType EnumerationType Values:
|
.1.3.6.1.4.1.3607.2.30.2.2.1.2 |
||||||||||||||||||||||
|
cOpticalPMIntervalPeriod
This object is an index into the
cOpticalPMIntervalTable and indicates whether the optical parameter values given in this entry, are collected over a period of 15 minutes or 24 hours. |
CERENT-TCCerentPeriod Textual Convention: CERENT-TCCerentPeriod EnumerationType Values:
|
.1.3.6.1.4.1.3607.2.30.2.2.1.3 |
||||||||||||||||||||||
|
cOpticalPMIntervalNumber
This object is an index into the cOpticalPMIntervalTable.
It is a number between 1 and 96, which identifies the interval for which the set of optical parameter values is available. The interval identified by 1 is the m… |
Integer32 Constraints: range: 1-96 |
.1.3.6.1.4.1.3607.2.30.2.2.1.4 |
||||||||||||||||||||||
|
cOpticalPMIntervalMaxParam
This object gives the maximum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval. |
OpticalParameterValue Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.2.2.1.5 |
||||||||||||||||||||||
|
cOpticalPMIntervalMinParam
This object gives the minimum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval. |
OpticalParameterValue Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.2.2.1.6 |
||||||||||||||||||||||
|
cOpticalPMIntervalMeanParam
This object gives the average value of the measured optical
parameter, in a particular 15 minute or 24 hour interval. |
OpticalParameterValue Textual Convention: OpticalParameterValue Integer32Type Constraints: range: -1000000..1000000 |
.1.3.6.1.4.1.3607.2.30.2.2.1.7 |
||||||||||||||||||||||
|
cOpticalPMIntervalValidData
This variable indicates if the data for this
interval is valid. |
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|