CERENT-OPTICAL-MONITOR-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
25
.1.3.6.1.4.1.3607.2.30.1.1 · 1 row entry · 11 columns
This table provides objects to monitor optical
parameters in a network element. It also provides
objects for setting high and low threshold levels, with
configurable severities, on these monitored parameters.
cOpticalMonEntry entry .1.3.6.1.4.1.3607.2.30.1.1.1
An entry in the cOpticalMonTable provides objects to
monitor an optical parameter and set threshold levels
on that parameter, at an optical interface.

Note that the set of monitored optical parameters may v…
Indexes
IF-MIBifIndex cOpticalMonDirection cOpticalMonParameterType
Column Syntax OID
cOpticalMonDirection
This object is an index into the cOpticalMonTable
and indicates the direction monitored for the
optical interface, in this entry.
OpticalIfDirection
Textual Convention: OpticalIfDirection Enumeration
Type Values:
1receive
2transmit
3notApplicable
.1.3.6.1.4.1.3607.2.30.1.1.1.1
cOpticalMonParameterType
This object is an index into the cOpticalMonTable
and specifies the optical parameter that is being monitored,
in this entry.
OpticalParameterType
Textual Convention: OpticalParameterType Enumeration
Type Values:
1power
2acPower
3apdTemp
4laserTemp
5biasCurrent
6peltierCurrent
7xcvrVoltage
8voa
9gain
10oscPower
11addPower
.1.3.6.1.4.1.3607.2.30.1.1.1.2
cOpticalParameterValue
This object gives the value measured for the particular
optical parameter specified by the cOpticalMonParameterType
object.
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.3
cOpticalParamHighAlarmThresh
This object is used to set a high alarm threshold on the
optical parameter being monitored.

If the measured value of the parameter,is greater than the
value configured in this object, an alarm will be r…
OpticalParameterValuer/w
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.4
cOpticalParamHighWarning15MinThresh
This object is used to set a high warning 15 minute threshold
on the optical parameter being monitored.

If the measured value of the parameter,is greater than the
value configured in this object, an al…
OpticalParameterValuer/w
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.5
cOpticalParamHighWarning1DayThresh
This object is used to set a high warning 1 day threshold on
the optical parameter being monitored.

If the measured value of the parameter,is greater than the
value configured in this object, an alarm …
OpticalParameterValuer/w
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.6
cOpticalParamLowAlarmThresh
This object is used to set a low alarm threshold on the
optical parameter being monitored.

If the measured value of the parameter,goes lower than the
value configured in this object, an alarm will be ra…
OpticalParameterValuer/w
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.7
cOpticalParamLowWarning15MinThresh
This object is used to set a low warning 15 minute threshold
on the optical parameter being monitored.

If the measured value of the parameter,goes lower than the
value configured in this object, an alar…
OpticalParameterValuer/w
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.8
cOpticalParamLowWarning1DayThresh
This object is used to set a low warning 1 day threshold
on the optical parameter being monitored.

If the measured value of the parameter,goes lower than the
value configured in this object, an alarm w…
OpticalParameterValuer/w
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.9
cOpticalParamLowDegradeThresh
This object is used to set a low degrade threshold
on the optical parameter being monitored.

If the measured value of the parameter,goes lower than the
value configured in this object, a degrade alarm …
OpticalParameterValuer/w
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.10
cOpticalParamHighDegradeThresh
This object is used to set a high degrade threshold
on the optical parameter being monitored.

If the measured value of the parameter,goes lower than the
value configured in this object, a degrade alarm…
OpticalParameterValuer/w
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.11
.1.3.6.1.4.1.3607.2.30.2.1 · 1 row entry · 6 columns
This table stores performance monitoring data for the
various optical parameters, collected over the current
interval.
cOpticalPMCurrentEntry entry .1.3.6.1.4.1.3607.2.30.2.1.1
An entry in the cOpticalPMCurrentTable. It contains
performance monitoring data for an optical parameter,
collected over the current interval.

Note that the set of monitored optical parameters may vary
base…
Indexes
IF-MIBifIndex cOpticalPMCurrentDirection cOpticalPMCurrentParamType cOpticalPMCurrentPeriod
Column Syntax OID
cOpticalPMCurrentDirection
This object is an index into the cOpticalPMCurrentTable
and indicates the direction monitored
for the optical interface, in this entry.
OpticalIfDirection
Textual Convention: OpticalIfDirection Enumeration
Type Values:
1receive
2transmit
3notApplicable
.1.3.6.1.4.1.3607.2.30.2.1.1.1
cOpticalPMCurrentParamType
This object is an index into the
cOpticalPMCurrentTable and specifies the optical parameter
that is being monitored, in this entry.
OpticalParameterType
Textual Convention: OpticalParameterType Enumeration
Type Values:
1power
2acPower
3apdTemp
4laserTemp
5biasCurrent
6peltierCurrent
7xcvrVoltage
8voa
9gain
10oscPower
11addPower
.1.3.6.1.4.1.3607.2.30.2.1.1.2
cOpticalPMCurrentPeriod
This object is an index into the
cOpticalPMCurrentTable and indicates whether the
optical parameter values given in this entry, are collected
over a period of 15 minutes or 24 hours.
CERENT-TCCerentPeriod
Textual Convention: CERENT-TCCerentPeriod Enumeration
Type Values:
1unknown
5minutes1
10minutes15
20hour1
30day1
.1.3.6.1.4.1.3607.2.30.2.1.1.3
cOpticalPMCurrentMaxParam
This object gives the maximum value measured for the optical
parameter, in the current 15 minute or 24 hour interval.
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.2.1.1.4
cOpticalPMCurrentMinParam
This object gives the minimum value measured for the optical
parameter, in the current 15 minute or 24 hour interval.
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.2.1.1.5
cOpticalPMCurrentMeanParam
This object gives the average value of the measured optical
parameter, in the current 15 minute or 24 hour interval.
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.2.1.1.6
.1.3.6.1.4.1.3607.2.30.2.2 · 1 row entry · 8 columns
This table stores performance monitoring data for the
various optical parameters, collected over current and 
previous intervals.
          
This table can have entries for up to 96 complete 15 minute  
intervals.
cOpticalPMIntervalEntry entry .1.3.6.1.4.1.3607.2.30.2.2.1
An entry in the cOpticalPMIntervalTable. It contains
performance monitoring data for an optical parameter,
collected over current and previous intervals.

Note that the set of monitored optical parameters ma…
Indexes
IF-MIBifIndex cOpticalPMIntervalDirection cOpticalPMIntervalParamType cOpticalPMIntervalPeriod cOpticalPMIntervalNumber
Column Syntax OID
cOpticalPMIntervalDirection
This object is an index into the cOpticalPMIntervalTable
and indicates the direction monitored
for the optical interface, in this entry.
OpticalIfDirection
Textual Convention: OpticalIfDirection Enumeration
Type Values:
1receive
2transmit
3notApplicable
.1.3.6.1.4.1.3607.2.30.2.2.1.1
cOpticalPMIntervalParamType
This object is an index into the
cOpticalPMIntervalTable and specifies the optical parameter
that is being monitored, in this entry.
OpticalParameterType
Textual Convention: OpticalParameterType Enumeration
Type Values:
1power
2acPower
3apdTemp
4laserTemp
5biasCurrent
6peltierCurrent
7xcvrVoltage
8voa
9gain
10oscPower
11addPower
.1.3.6.1.4.1.3607.2.30.2.2.1.2
cOpticalPMIntervalPeriod
This object is an index into the
cOpticalPMIntervalTable and indicates whether the
optical parameter values given in this entry, are collected
over a period of 15 minutes or 24 hours.
CERENT-TCCerentPeriod
Textual Convention: CERENT-TCCerentPeriod Enumeration
Type Values:
1unknown
5minutes1
10minutes15
20hour1
30day1
.1.3.6.1.4.1.3607.2.30.2.2.1.3
cOpticalPMIntervalNumber
This object is an index into the cOpticalPMIntervalTable.
It is a number between 1 and 96, which identifies the
interval for which the set of optical parameter values is
available. The interval identified by 1 is the m…
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3607.2.30.2.2.1.4
cOpticalPMIntervalMaxParam
This object gives the maximum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval.
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.2.2.1.5
cOpticalPMIntervalMinParam
This object gives the minimum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval.
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.2.2.1.6
cOpticalPMIntervalMeanParam
This object gives the average value of the measured optical
parameter, in a particular 15 minute or 24 hour interval.
OpticalParameterValue
Textual Convention: OpticalParameterValue Integer32
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.2.2.1.7
cOpticalPMIntervalValidData
This variable indicates if the data for this
interval is valid.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.3607.2.30.2.2.1.8