cOpticalPMIntervalParamType
CERENT-OPTICAL-MONITOR-MIB ·
.1.3.6.1.4.1.3607.2.30.2.2.1.2
Object
column
OpticalParameterType
This object is an index into the cOpticalPMIntervalTable and specifies the optical parameter that is being monitored, in this entry.
Context
- MIB
- CERENT-OPTICAL-MONITOR-MIB
- OID
.1.3.6.1.4.1.3607.2.30.2.2.1.2- Type
- column
- Access
- noaccess
- Status
- current
- Parent
- cOpticalPMIntervalEntry
- Table
- cOpticalPMIntervalTable
- Siblings
- 7
Syntax
OpticalParameterType
- Source
- OpticalParameterType
- Base type
Enumeration
Values & Constraints
Type Values
1 | power |
2 | acPower |
3 | apdTemp |
4 | laserTemp |
5 | biasCurrent |
6 | peltierCurrent |
7 | xcvrVoltage |
8 | voa |
9 | gain |
10 | oscPower |
11 | addPower |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cOpticalPMIntervalDirection This object is an index into the cOpticalPMIntervalTable
and indicates the direction monitored
for the optical interface, in this entry. | column | OpticalIfDirection | .1.3.6.1.4.1.3607.2.30.2.2.1.1 |
| cOpticalPMIntervalPeriod This object is an index into the
cOpticalPMIntervalTable and indicates whether the
optical parameter values given in this entry, are collected
over a period of 15 minutes or 24 ho… | column | CERENT-TCCerentPeriod | .1.3.6.1.4.1.3607.2.30.2.2.1.3 |
| cOpticalPMIntervalNumber This object is an index into the cOpticalPMIntervalTable.
It is a number between 1 and 96, which identifies the
interval for which the set of optical parameter values is
availabl… | column | Integer32 | .1.3.6.1.4.1.3607.2.30.2.2.1.4 |
| cOpticalPMIntervalMaxParam This object gives the maximum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval. | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.2.2.1.5 |
| cOpticalPMIntervalMinParam This object gives the minimum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval. | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.2.2.1.6 |
| cOpticalPMIntervalMeanParam This object gives the average value of the measured optical
parameter, in a particular 15 minute or 24 hour interval. | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.2.2.1.7 |
| cOpticalPMIntervalValidData This variable indicates if the data for this
interval is valid. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.3607.2.30.2.2.1.8 |