cOpticalParamLowAlarmThresh

CERENT-OPTICAL-MONITOR-MIB · .1.3.6.1.4.1.3607.2.30.1.1.1.7

Object

column r/w OpticalParameterValue
This object is used to set a low alarm threshold on the 
optical parameter being monitored.
              
If the measured value of the parameter,goes lower than the 
value configured in this object, an alarm will be raised.
              
When the cOpticalMonParameterType object is set to 'power'
for the receive direction and when the interface supports
alarms based on loss of light, this object specifies the
optical power threshold for declaring loss of light. Also,
when optical amplifiers are present in the network, in the
receive direction, this value may need to be configured,
since the noise floor may be higher than the minimum
sensitivity of the receiver.

Context

MIB
CERENT-OPTICAL-MONITOR-MIB
OID
.1.3.6.1.4.1.3607.2.30.1.1.1.7
Type
column
Access
readwrite
Status
current
Parent
cOpticalMonEntry
Table
cOpticalMonTable
Siblings
10

Syntax

OpticalParameterValue
Source
OpticalParameterValue
Base type
Integer32

Values & Constraints

Type Constraints
range: -1000000..1000000

Related Objects