cOpticalParamLowWarning15MinThresh
CERENT-OPTICAL-MONITOR-MIB ·
.1.3.6.1.4.1.3607.2.30.1.1.1.8
Object
column
r/w
OpticalParameterValue
This object is used to set a low warning 15 minute threshold
on the optical parameter being monitored.
If the measured value of the parameter,goes lower than the
value configured in this object, an alarm will be raised.
Context
- MIB
- CERENT-OPTICAL-MONITOR-MIB
- OID
.1.3.6.1.4.1.3607.2.30.1.1.1.8- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- cOpticalMonEntry
- Table
- cOpticalMonTable
- Siblings
- 10
Syntax
OpticalParameterValue
- Source
- OpticalParameterValue
- Base type
Integer32
Values & Constraints
Type Constraints
range: -1000000..1000000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cOpticalMonDirection This object is an index into the cOpticalMonTable
and indicates the direction monitored for the
optical interface, in this entry. | column | OpticalIfDirection | .1.3.6.1.4.1.3607.2.30.1.1.1.1 |
| cOpticalParamLowDegradeThresh This object is used to set a low degrade threshold
on the optical parameter being monitored.
If the measured value of the parameter,goes lower than the
value con… | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.10 |
| cOpticalParamHighDegradeThresh This object is used to set a high degrade threshold
on the optical parameter being monitored.
If the measured value of the parameter,goes lower than the
value co… | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.11 |
| cOpticalMonParameterType This object is an index into the cOpticalMonTable
and specifies the optical parameter that is being monitored,
in this entry. | column | OpticalParameterType | .1.3.6.1.4.1.3607.2.30.1.1.1.2 |
| cOpticalParameterValue This object gives the value measured for the particular
optical parameter specified by the cOpticalMonParameterType
object. | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.3 |
| cOpticalParamHighAlarmThresh This object is used to set a high alarm threshold on the
optical parameter being monitored.
If the measured value of the parameter,is greater than the
value confi… | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.4 |
| cOpticalParamHighWarning15MinThresh This object is used to set a high warning 15 minute threshold
on the optical parameter being monitored.
If the measured value of the parameter,is greater than the… | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.5 |
| cOpticalParamHighWarning1DayThresh This object is used to set a high warning 1 day threshold on
the optical parameter being monitored.
If the measured value of the parameter,is greater than the
va… | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.6 |
| cOpticalParamLowAlarmThresh This object is used to set a low alarm threshold on the
optical parameter being monitored.
If the measured value of the parameter,goes lower than the
value config… | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.7 |
| cOpticalParamLowWarning1DayThresh This object is used to set a low warning 1 day threshold
on the optical parameter being monitored.
If the measured value of the parameter,goes lower than the
val… | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.9 |