cOpticalPMIntervalEntry
CERENT-OPTICAL-MONITOR-MIB ·
.1.3.6.1.4.1.3607.2.30.2.2.1
Object
row
An entry in the cOpticalPMIntervalTable. It contains
performance monitoring data for an optical parameter,
collected over current and previous intervals.
Note that the set of monitored optical parameters may vary
based on interface type and direction.
Examples of interfaces that can have an entry in this table
include optical transceivers, optical amplifiers, and optical
attenuators.
Context
- MIB
- CERENT-OPTICAL-MONITOR-MIB
- OID
.1.3.6.1.4.1.3607.2.30.2.2.1- Type
- row
- Status
- current
- Parent
- cOpticalPMIntervalTable
- Table
- cOpticalPMIntervalTable
- Children
- 8
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cOpticalPMIntervalDirection This object is an index into the cOpticalPMIntervalTable
and indicates the direction monitored
for the optical interface, in this entry. | column | OpticalIfDirection | .1.3.6.1.4.1.3607.2.30.2.2.1.1 |
| cOpticalPMIntervalParamType This object is an index into the
cOpticalPMIntervalTable and specifies the optical parameter
that is being monitored, in this entry. | column | OpticalParameterType | .1.3.6.1.4.1.3607.2.30.2.2.1.2 |
| cOpticalPMIntervalPeriod This object is an index into the
cOpticalPMIntervalTable and indicates whether the
optical parameter values given in this entry, are collected
over a period of 15 minutes or 24 ho… | column | CERENT-TCCerentPeriod | .1.3.6.1.4.1.3607.2.30.2.2.1.3 |
| cOpticalPMIntervalNumber This object is an index into the cOpticalPMIntervalTable.
It is a number between 1 and 96, which identifies the
interval for which the set of optical parameter values is
availabl… | column | Integer32 | .1.3.6.1.4.1.3607.2.30.2.2.1.4 |
| cOpticalPMIntervalMaxParam This object gives the maximum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval. | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.2.2.1.5 |
| cOpticalPMIntervalMinParam This object gives the minimum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval. | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.2.2.1.6 |
| cOpticalPMIntervalMeanParam This object gives the average value of the measured optical
parameter, in a particular 15 minute or 24 hour interval. | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.2.2.1.7 |
| cOpticalPMIntervalValidData This variable indicates if the data for this
interval is valid. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.3607.2.30.2.2.1.8 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| IF-MIBifIndex A unique value, greater than zero, for each interface. It
is recommended that values are assigned contiguously
starting from 1. The value for each interface sub-layer
must remai… | column | InterfaceIndex | .1.3.6.1.2.1.2.2.1.1 |
| cOpticalPMIntervalDirection This object is an index into the cOpticalPMIntervalTable
and indicates the direction monitored
for the optical interface, in this entry. | column | OpticalIfDirection | .1.3.6.1.4.1.3607.2.30.2.2.1.1 |
| cOpticalPMIntervalParamType This object is an index into the
cOpticalPMIntervalTable and specifies the optical parameter
that is being monitored, in this entry. | column | OpticalParameterType | .1.3.6.1.4.1.3607.2.30.2.2.1.2 |
| cOpticalPMIntervalPeriod This object is an index into the
cOpticalPMIntervalTable and indicates whether the
optical parameter values given in this entry, are collected
over a period of 15 minutes or 24 ho… | column | CERENT-TCCerentPeriod | .1.3.6.1.4.1.3607.2.30.2.2.1.3 |
| cOpticalPMIntervalNumber This object is an index into the cOpticalPMIntervalTable.
It is a number between 1 and 96, which identifies the
interval for which the set of optical parameter values is
availabl… | column | Integer32 | .1.3.6.1.4.1.3607.2.30.2.2.1.4 |