cOpticalParamHighDegradeThresh
CERENT-OPTICAL-MONITOR-MIB ·
.1.3.6.1.4.1.3607.2.30.1.1.1.11
Object
column
r/w
OpticalParameterValue
This object is used to set a high degrade threshold
on the optical parameter being monitored.
If the measured value of the parameter,goes lower than the
value configured in this object, a degrade alarm will be raised.
Context
- MIB
- CERENT-OPTICAL-MONITOR-MIB
- OID
.1.3.6.1.4.1.3607.2.30.1.1.1.11- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- cOpticalMonEntry
- Table
- cOpticalMonTable
- Siblings
- 10
Syntax
OpticalParameterValue
- Source
- OpticalParameterValue
- Base type
Integer32
Values & Constraints
Type Constraints
range: -1000000..1000000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cOpticalMonDirection This object is an index into the cOpticalMonTable
and indicates the direction monitored for the
optical interface, in this entry. | column | OpticalIfDirection | .1.3.6.1.4.1.3607.2.30.1.1.1.1 |
| cOpticalParamLowDegradeThresh This object is used to set a low degrade threshold
on the optical parameter being monitored.
If the measured value of the parameter,goes lower than the
value con… | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.10 |
| cOpticalMonParameterType This object is an index into the cOpticalMonTable
and specifies the optical parameter that is being monitored,
in this entry. | column | OpticalParameterType | .1.3.6.1.4.1.3607.2.30.1.1.1.2 |
| cOpticalParameterValue This object gives the value measured for the particular
optical parameter specified by the cOpticalMonParameterType
object. | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.3 |
| cOpticalParamHighAlarmThresh This object is used to set a high alarm threshold on the
optical parameter being monitored.
If the measured value of the parameter,is greater than the
value confi… | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.4 |
| cOpticalParamHighWarning15MinThresh This object is used to set a high warning 15 minute threshold
on the optical parameter being monitored.
If the measured value of the parameter,is greater than the… | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.5 |
| cOpticalParamHighWarning1DayThresh This object is used to set a high warning 1 day threshold on
the optical parameter being monitored.
If the measured value of the parameter,is greater than the
va… | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.6 |
| cOpticalParamLowAlarmThresh This object is used to set a low alarm threshold on the
optical parameter being monitored.
If the measured value of the parameter,goes lower than the
value config… | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.7 |
| cOpticalParamLowWarning15MinThresh This object is used to set a low warning 15 minute threshold
on the optical parameter being monitored.
If the measured value of the parameter,goes lower than the
… | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.8 |
| cOpticalParamLowWarning1DayThresh This object is used to set a low warning 1 day threshold
on the optical parameter being monitored.
If the measured value of the parameter,goes lower than the
val… | column | OpticalParameterValue | .1.3.6.1.4.1.3607.2.30.1.1.1.9 |