Logical Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array logical drive. The variable
cpqDaLogDrvStatus indicates the current logical drive status.
cpqDa2SpareStatusChange
.1.3.6.1.4.1.232.0.3002
Spare Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array spare drive. The variable
cpqDaSpareStatus indicates the current spare drive status.
The variable cpqDaSpareBusNumber indicates the SCSI bus number
associated with this drive.
cpqDa2PhyDrvStatusChange
.1.3.6.1.4.1.232.0.3003
Physical Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array physical drive. The variable
cpaDaPhyDrvStatus indicates the current physical drive status.
The variable cpqDaPhyDrvBusNumber indicates the SCSI bus number
associated with this drive.
cpqDa2PhyDrvThreshPassedTrap
.1.3.6.1.4.1.232.0.3004
Physical Drive Threshold Passed.
This trap signifies that the agent has detected a factory
threshold associated with one of the physical drive objects on
a drive array has been exceeded. The variable
cpqDaPhyDrvBusNumber indicates the SCSI bus number associated
with the drive.
cpqDa2AccelStatusChange
.1.3.6.1.4.1.232.0.3005
Accelerator Board Status Change.
This trap signifies that the Insight Agent has detected a
change in the cpqDaAccelStatus of array accelerator cache.
The current status is represented by the variable
cpqDaAccelStatus.
cpqDa2AccelBadDataTrap
.1.3.6.1.4.1.232.0.3006
Accelerator Board Bad Data.
This trap signifies that the agent has detected an array
accelerator cache board that has lost battery power. If data
was being stored in the accelerator memory when the server lost
power, that data has been lost.
cpqDa2AccelBatteryFailed
.1.3.6.1.4.1.232.0.3007
Accelerator Board Battery Failed.
This trap signifies that the agent has detected a battery
failure associated with the array accelerator cache board. The
current battery status is indicated by the cpqDaAccelBattery
variable.
cpqDa3LogDrvStatusChange
.1.3.6.1.4.1.232.0.3008
Logical Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array logical drive. The variable
cpqDaLogDrvStatus indicates the current logical drive status.
cpqDa3SpareStatusChange
.1.3.6.1.4.1.232.0.3009
Spare Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array spare drive. The variable
cpqDaSpareStatus indicates the current spare drive status. The
variable cpqDaSpareBusNumber indicates the SCSI bus number
associated with this drive.
cpqDa3PhyDrvStatusChange
.1.3.6.1.4.1.232.0.3010
Physical Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array physical drive. The variable
cpaDaPhyDrvStatus indicates the current physical drive status.
The variable cpqDaPhyDrvBusNumber indicates the SCSI bus number
associated with this drive.
cpqDa3PhyDrvThreshPassedTrap
.1.3.6.1.4.1.232.0.3011
Physical Drive Threshold Passed.
This trap signifies that the agent has detected a factory
threshold associated with one of the physical drive objects on
a drive array has been exceeded. The variable
cpqDaPhyDrvBusNumber indicates the SCSI bus number associated
with the drive.
cpqDa3AccelStatusChange
.1.3.6.1.4.1.232.0.3012
Accelerator Board Status Change.
This trap signifies that the agent has detected a change in the
cpqDaAccelStatus of an array accelerator cache board. The
current status is represented by the variable cpqDaAccelStatus.
cpqDa3AccelBadDataTrap
.1.3.6.1.4.1.232.0.3013
Accelerator Board Bad Data.
This trap signifies that the agent has detected an array
accelerator cache board that has lost battery power. If data
was being stored in the accelerator memory when the server lost
power, that data has been lost.
cpqDa3AccelBatteryFailed
.1.3.6.1.4.1.232.0.3014
Accelerator Board Battery Failed.
This trap signifies that the agent has detected a battery
failure associated with the array accelerator cache board. The
current battery status is indicated by the cpqDaAccelBattery
variable.
cpqDaCntlrStatusChange
.1.3.6.1.4.1.232.0.3015
Controller Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array controller. The variable
cpqDaCntlrBoardStatus indicates the current controller status.
User Action: If the board status is generalFailure(3), the
you may need to replace the controller. If the board status
is cableProblem(4), check the cable connections between the
controller and the storage system.
cpqDaCntlrActive
.1.3.6.1.4.1.232.0.3016
Controller Active.
This trap signifies that the agent has detected that a backup
array controller in a duplexed pair has switched over to the
active role. The variable cpqDaCntlrSlot indicates the
active controller slot and cpqDaCntlrPartnerSlot indicates the
backup.
User Action: Check the partner controller for problems.
If this was the result of a user initiated switch over,
no action is required.
cpqDa4SpareStatusChange
.1.3.6.1.4.1.232.0.3017
Spare Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array spare drive. The variable
cpqDaSpareStatus indicates the current spare drive status.
User Action: If the spare drive status is failed, replace
the drive.
cpqDa4PhyDrvStatusChange
.1.3.6.1.4.1.232.0.3018
Physical Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array physical drive. The variable
cpaDaPhyDrvStatus indicates the current physical drive status.
User Action: If the physical drive failed or predicting
failure, replace the drive.
cpqDa4PhyDrvThreshPassedTrap
.1.3.6.1.4.1.232.0.3019
Physical Drive Threshold Passed.
This trap signifies that the agent has detected a factory
threshold associated with one of the physical drive objects on
a drive array has been exceeded.
User Action: If the physical drive is predicting failure,
replace the drive.
cpqDaTapeLibraryStatusChange
.1.3.6.1.4.1.232.0.3020
Tape Library Status Change.
This trap signifies that the agent has detected a change in
the status of a tape library. The variable
cpqDaTapeLibraryStatus indicates the current tape library
status. The variable cpqDaTapeLibraryScsiTarget indicates
the SCSI ID of the tape library.
User Action: If the tape library is failed, check the tape
library front panel.
cpqDaTapeLibraryDoorStatusChange
.1.3.6.1.4.1.232.0.3021
Tape Library Door Status Change.
This trap signifies that the agent has detected a change in
the door status of a tape library. The variable
cpqDaTapeLibraryDoorStatus indicates the current tape library
door status. The variable cpqDaTapeLibraryScsiTarget indicates
the the SCSI ID of the tape library.
User Action: If the tape library door is open, close the tape
library door.
cpqDaTapeDriveStatusChange
.1.3.6.1.4.1.232.0.3022
Tape Drive Status Change.
This trap signifies that the agent has detected a change in
the status of a tape drive. The variable cpqDaTapeDrvStatus
indicates the current tape status. The variable
cpqDaTapeDrvScsiIdIndex indicates the the SCSI ID of the tape
drive.
User Action: If the tape is failed, check the tape and
all SCSI connections.
cpqDaTapeDriveCleaningRequired
.1.3.6.1.4.1.232.0.3023
Tape Drive Cleaning Required trap.
The agent has detected a tape drive that needs to have a
cleaning tape inserted and run. This will cause the tape
drive heads to be cleaned.
cpqDaTapeDriveCleanTapeReplace
.1.3.6.1.4.1.232.0.3024
Tape Drive Cleaning Tape Needs Replacing.
The agent has detected that an autoloader tape unit has a
cleaning tape that has been fully used and therefore needs to
be replaced with a new cleaning tape.
cpqDa5AccelStatusChange
.1.3.6.1.4.1.232.0.3025
Accelerator Board Status Change.
This trap signifies that the agent has detected a change in
the status of an array accelerator cache board. The current
status is represented by the variable cpqDaAccelStatus.
User Action: If the accelerator board status is permDisabled(5),
you may need to replace the accelerator board.
cpqDa5AccelBadDataTrap
.1.3.6.1.4.1.232.0.3026
Accelerator Board Bad Data.
This trap signifies that the agent has detected an array
accelerator cache board that has lost battery power. If
data was being stored in the accelerator cache memory when the
server lost power, that data has been lost.
User Action: Verify that no data has been lost.
cpqDa5AccelBatteryFailed
.1.3.6.1.4.1.232.0.3027
Accelerator Board Battery Failed.
This trap signifies that the agent has detected a battery
failure associated with the array accelerator cache board.
User Action: Replace the Accelerator Cache Board.
cpqDa5CntlrStatusChange
.1.3.6.1.4.1.232.0.3028
Controller Status Change.
This trap signifies that the agent has detected a change in
the status of a drive array controller. The variable
cpqDaCntlrBoardStatus indicates the current controller status.
User Action: If the board status is generalFailure(3), you
may need to replace the controller. If the board status is
cableProblem(4), check the cable connections between the
controller and the storage system.
cpqDa5PhyDrvStatusChange
.1.3.6.1.4.1.232.0.3029
Physical Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array physical drive. The variable
cpaDaPhyDrvStatus indicates the current physical drive status.
User Action: If the physical drive status is failed(3) or
predictiveFailure(4), replace the drive.
cpqDa5PhyDrvThreshPassedTrap
.1.3.6.1.4.1.232.0.3030
Physical Drive Threshold Passed.
This trap signifies that the agent has detected a factory
threshold associated with one of the physical drive objects
on a drive array has been exceeded.
User Action: Replace the physical drive.
cpqDa2TapeLibraryStatusChange
.1.3.6.1.4.1.232.0.3031
Tape Library Status Change.
This trap signifies that the agent has detected a change in
the status of a tape library. The variable
cpqDaTapeLibraryStatus indicates the current tape library
status. The variable cpqDaTapeLibraryScsiTarget indicates
the SCSI ID of the tape library.
User Action: If the tape library is failed, check the tape
library front panel.
cpqDa2TapeDriveStatusChange
.1.3.6.1.4.1.232.0.3032
Tape Drive Status Change.
This trap signifies that the agent has detected a change in
the status of a tape drive. The variable cpqDaTapeDrvStatus
indicates the current tape status. The variable
cpqDaTapeDrvScsiIdIndex indicates the the SCSI ID of the tape
drive.
User Action: If the tape is failed, check the tape and
all SCSI connections.
cpqDa6CntlrStatusChange
.1.3.6.1.4.1.232.0.3033
Controller Status Change.
This trap signifies that the agent has detected a change in
the status of a drive array controller. The variable
cpqDaCntlrBoardStatus indicates the current controller status.
User Action: If cpqDaCntlrBoardStatus is `generalFailure(3)`, you
may need to reboot the server or replace the controller.
After the system is rebooted, check the variable
cpqDaCntlrLastLockupCode for last lockup code of the controller.
If cpqDaCntlrBoardStatus is `cableProblem(4)`, check the cable
connections between the controller and the storage system. If
cpqDaCntlrBoardStatus is `cacheModuleMissing(6)`, the array
controller is operating in an unsupported configuration and
requires that a cache module be attached to the controller.
cpqDa6LogDrvStatusChange
.1.3.6.1.4.1.232.0.3034
Logical Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array logical drive. The variable
cpqDaLogDrvStatus indicates the current logical drive status.
cpqDa6SpareStatusChange
.1.3.6.1.4.1.232.0.3035
Spare Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array spare drive. The variable
cpqDaSpareStatus indicates the current spare drive status.
User Action: If the spare drive status is failed, replace
the drive.
cpqDa6PhyDrvStatusChange
.1.3.6.1.4.1.232.0.3036
Physical Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array physical drive. The variable
cpaDaPhyDrvStatus indicates the current physical drive status.
User Action: If the physical drive status is failed(3) or
predictiveFailure(4), replace the drive.
cpqDa6PhyDrvThreshPassedTrap
.1.3.6.1.4.1.232.0.3037
Physical Drive Threshold Passed.
This trap signifies that the agent has detected a factory
threshold associated with one of the physical drive objects
on a drive array has been exceeded.
User Action: Replace the physical drive.
cpqDa6AccelStatusChange
.1.3.6.1.4.1.232.0.3038
Storage - Controller Write Cache Status Changed.
This trap signifies that the agent has detected a change in
the status of a cache. The current status is represented by
the variable cpqDaAccelStatus.
cpqDa6AccelBadDataTrap
.1.3.6.1.4.1.232.0.3039
Storage - Controller Write Cache Data Lost.
This trap signifies that the agent has detected a controller cache
module that has lost backup power. If data was being stored in the
cache module memory when the server lost power, that data has been lost.
The backup power source is indicated by cpqDaAccelBackupPowerSource.
cpqDa6AccelBatteryFailed
.1.3.6.1.4.1.232.0.3040
Cache Module Board Backup Power Source Failed.
This trap signifies that the agent has detected a backup
power source failure associated with the cache module
board. The backup power source is indicated by
cpqDaAccelBackupPowerSource.
User Action: Replace the Backup Power Source.
cpqDa6TapeLibraryStatusChange
.1.3.6.1.4.1.232.0.3041
Tape Library Status Change.
This trap signifies that the agent has detected a change in
the status of a tape library. The variable
cpqDaTapeLibraryStatus indicates the current tape library
status. The variable cpqDaTapeLibraryScsiTarget indicates
the SCSI ID of the tape library.
User Action: If cpqDaTapeLibraryStatus is `failed(4)`, check the
tape library front panel.
cpqDa6TapeLibraryDoorStatusChange
.1.3.6.1.4.1.232.0.3042
Tape Library Door Status Change.
This trap signifies that the agent has detected a change in
the door status of a tape library. The variable
cpqDaTapeLibraryDoorStatus indicates the current tape library
door status. The variable cpqDaTapeLibraryScsiTarget indicates
the the SCSI ID of the tape library.
User Action: If cpqDaTapeLibraryDoorStatus is `open(4)`, close the
tape library door.
cpqDa6TapeDriveStatusChange
.1.3.6.1.4.1.232.0.3043
Tape Drive Status Change.
This trap signifies that the agent has detected a change in
the status of a tape drive. The variable cpqDaTapeDrvStatus
indicates the current tape status. The variable
cpqDaTapeDrvScsiIdIndex indicates the the SCSI ID of the tape
drive.
User Action: If cpqDaTapeDrvStatus is `failed(4)`, check the tape
and all SCSI connections.
cpqDa6TapeDriveCleaningRequired
.1.3.6.1.4.1.232.0.3044
Tape Drive Cleaning Required trap.
The agent has detected a tape drive that needs to have a
cleaning tape inserted and run. This will cause the tape
drive heads to be cleaned.
cpqDa6TapeDriveCleanTapeReplace
.1.3.6.1.4.1.232.0.3045
Tape Drive Cleaning Tape Needs Replacing.
The agent has detected that an autoloader tape unit has a
cleaning tape that has been fully used and therefore needs to
be replaced with a new cleaning tape.
cpqDa7PhyDrvStatusChange
.1.3.6.1.4.1.232.0.3046
Physical Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array physical drive. The variable
cpaDaPhyDrvStatus indicates the current physical drive status.
User Action: If cpaDaPhyDrvStatus is `failed(3)`,
`predictiveFailure(4)`, `ssdWearOut(8)`, or `notAuthenticated(9)`,
replace the drive.
cpqDa7SpareStatusChange
.1.3.6.1.4.1.232.0.3047
Spare Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array spare drive. The variable
cpqDaSpareStatus indicates the current spare drive status.
User Action: If cpqDaSpareStatus is `failed(3)`, replace the
drive.
cpqDaCntlrPartnerStatusChange
.1.3.6.1.4.1.232.0.3048
Partner Controller Status Change.
This trap signifies that the agent has detected a change in
the status of a drive array partner controller. The variable
cpqDaCntlrPartnerBoardStatus indicates the current partner
controller status. The variable cpqDaCntlrSerialNumber indicates
the controller serial number and cpqDaCntlrPartnerSerialNumber
indicates the partner controller serial number.
User Action: Check the partner controller for problems. If lost
communication with the partner controller is the result of a user
initiated action, no remedial action is required.
cpqDaPhyDrvSSDWearStatusChange
.1.3.6.1.4.1.232.0.3049
Solid State Disk Wear Status Change.
This trap signifies that the agent has detected a change in the
SSD wear status of a drive array physical drive. The variable
cpqDaPhyDrvSSDWearStatus indicates the current SSD wear status.
User Action: If cpqDaPhyDrvSSDWearStatus is `ssdWearOut(6)`, replace
the drive.
cpqDaSmartArraySecureEraseFailed
.1.3.6.1.4.1.232.0.3903
Secure Erase of Smart Array has failed.
cpqDaLogDrvStatusChange
.1.3.6.1.4.1.232.3.0.1
Logical Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array logical drive. The variable
cpqDaLogDrvStatus indicates the current logical drive status.
cpqDaSpareStatusChange
.1.3.6.1.4.1.232.3.0.2
Spare Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array spare drive. The variable
cpqDaSpareStatus indicates the current spare drive status. The
variable cpqDaSpareBusNumber indicates the SCSI bus number
associated with this drive.
cpqDaPhyDrvStatusChange
.1.3.6.1.4.1.232.3.0.3
Physical Drive Status Change.
This trap signifies that the agent has detected a change in the
status of a drive array physical drive. The variable
cpaDaPhyDrvStatus indicates the current physical drive status.
The variable cpqDaPhyDrvBusNumber indicates the SCSI bus number
associated with this drive.
cpqDaPhyDrvThreshPassedTrap
.1.3.6.1.4.1.232.3.0.4
Physical Drive Threshold Passed.
This trap signifies that the agent has detected a factory
threshold associated with one of the physical drive objects on
a drive array has been exceeded. The variable
cpqDaPhyDrvBusNumber indicates the SCSI bus number associated
with the drive.
cpqDaAccelStatusChange
.1.3.6.1.4.1.232.3.0.5
Accelerator Board Status Change.
This trap signifies that the agent has detected a change in the
cpqDaAccelStatus of an array accelerator write cache. The
current status is represented by the variable cpqDaAccelStatus.
cpqDaAccelBadDataTrap
.1.3.6.1.4.1.232.3.0.6
Accelerator Board Bad Data.
This trap signifies that the agent has detected an array
accelerator cache board that has lost battery power. If data
was being stored in the accelerator memory when the server lost
power, that data has been lost.
cpqDaAccelBatteryFailed
.1.3.6.1.4.1.232.3.0.7
Accelerator Board Battery Failed.
This trap signifies that the agent has detected a battery
failure associated with the array accelerator cache board.
The current battery status is indicated by the
cpqDaAccelBattery variable.