cpqDaPhyDrvStatus
CPQIDA-MIB ·
.1.3.6.1.4.1.232.3.2.5.1.1.6
Object
column
mandatory
Enumeration
Physical Drive Status.
This shows the status of the physical drive.
The following values are valid for the physical drive status:
Other (1)
Indicates that the instrument agent does not recognize
the drive. You may need to upgrade your instrument agent
and/or driver software.
Ok (2)
Indicates the drive is functioning properly.
Failed (3)
Indicates that the drive is no longer operating and
should be replaced.
Predictive Failure(4)
Indicates that the drive has a predictive failure error and
should be replaced.
Erasing(5)
Indicates that the drive is being erased.
Erase Done(6)
Indicates that the drive has been erased and is now in an
offline state.
Erase Queued(7)
Indicates that an erase operation is currently queued for
the drive.
SSD Wear Out(8)
Indicates that a solid state drive is approaching the maximum
usage limit for writes (wear out) and should be replaced as soon
as possible.
Not Authenticated(9)
Indicates the physical drive could not be authenticated as a genuine
HP hard drive. The array controller will no longer control the drive
LEDs. Please replace the hard drive with a genuine HP hard drive.