cpqDaLogDrvRebuildBlks
CPQIDA-MIB ·
.1.3.6.1.4.1.232.3.2.3.1.1.6
Object
Logical Drive Rebuild Blocks Remaining.
After a failed physical drive has been replaced, the physical
drive must have its data rebuilt. This value shows how many
blocks of data still need to be rebuilt. When the value
reaches zero, the rebuilding process is complete. The drive
array continues to operate in interim recovery mode while a
drive is rebuilding.
When a logical volume is Expanding, the drive must redistribute
the logical volume data across the physical drives. This value
shows how many blocks of data still need to be redistributed.
When the value reaches zero, the expand process is complete.
The drive array continues to operate normally while the drive
is expanding.
This value is only valid if the Logical Drive Status is
rebuilding (7) or expanding (12).