cpqDaNw3xPollTime
CPQIDA-MIB ·
.1.3.6.1.4.1.232.3.2.1.1.4
Object
scalar
obsolete
Integer32
Array Controller Driver Interface Poll Time.
If the Poll Type is Polled, this value shows how frequently,
in seconds, the instrument agent requests Information from
the device driver.
For example, if the Poll Type is Polled and the Poll Time
is two, the instrument agent will poll the device driver
every two seconds.
To change the Poll Time for NetWare, unload and then
reload the instrument agent using the following commands:
UNLOAD CPQDSKSA
LOAD CPQDSKSA [/Un]
The parameter /U specifies the frequency of updates in seconds.
The variable n represents the number of seconds that the NLM
should wait before collecting new data. The minimum value is
one second. The maximum value is 300 seconds (five minutes).
Context
- MIB
- CPQIDA-MIB
- OID
.1.3.6.1.4.1.232.3.2.1.1.4- Type
- scalar
- Access
- readonly
- Status
- obsolete
- Parent
- cpqDaOsNetWare3x
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-300