cpqDaPhyDrvDrqTimeouts
CPQIDA-MIB ·
.1.3.6.1.4.1.232.3.2.5.1.1.26
Object
DRQ Timeouts.
The number of times that a physical drive continued to request
data, but did not get a command completion during the reference
time (phyDrvRefTime). This value increases every time a DRQ
timeout occurs for the physical drive.
A defective drive or cable may cause DRQ timeouts to occur.
If you see an increase in these errors, complete the following
steps for the monitored system:
1. Check the cables connecting the drive to ensure that
they are intact.
2. If the cables are properly connected, schedule server down
time to run diagnostics to verify that a problem exists.
If the value is not supported, it is set to 4,294,967,295.
Context
- MIB
- CPQIDA-MIB
- OID
.1.3.6.1.4.1.232.3.2.5.1.1.26- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqDaPhyDrvEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQIDA-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQIDA-MIB::cpqDaPhyDrvDrqTimeouts'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CPQIDA-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQIDA-MIB::cpqDaPhyDrvDrqTimeouts.<cpqDaPhyDrvCntlrIndex>.<cpqDaPhyDrvIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CPQIDA-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQIDA-MIB::cpqDaPhyDrvDrqTimeouts'
Syntax
- Source
- RFC1155-SMICounter
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295