tmnxEqWrongCard

TIMETRA-CHASSIS-MIB · .1.3.6.1.4.1.6527.3.1.3.2.1.0.10

Object

notification
[CAUSE] Generated when the wrong type of card is inserted into a slot of
the chassis.  Even though a card may be physically supported by
the slot, it may have been administratively configured to allow
only certain card types in a particular slot location.  The card
type may be IOM (or XCM), Fabric, MDA (or XMA), CPM module, etc.
          
[EFFECT] The effect is dependent on the card that has been incorrectly
inserted. Incorrect IOM (or XCM) or MDA (or XMA) insertion will cause
a loss of service for all services running on that card.
          
[RECOVERY] Insert the correct card into the correct slot, and ensure
the slot is configured for the correct type of card.