tmnxEqMdaSyncENotCompatible

TIMETRA-CHASSIS-MIB · .1.3.6.1.4.1.6527.3.1.3.2.1.0.49

Object

notification
The tmnxEqMdaSyncENotCompatible notification is generated when an MDA
card is inserted into a slot of an IOM. The MDA is compatible with the
currently provisioned MDA, but the currently configured synchronous
ethernet, tmnxMDASynchronousEthernet, is not compatible with the
inserted MDA.
          
[EFFECT] Though services can still be created, if the
tmnxMdaNotifyType is the same as the tmnxMDAEquippedType then the MDA
will fail to operate as configured and will be in a failed state.
          
[RECOVERY] Change the configuration to reflect the capabilities of the
MDA port, or switch out/re-provision the MDA for one that is
compatible.

Context

MIB
TIMETRA-CHASSIS-MIB
OID
.1.3.6.1.4.1.6527.3.1.3.2.1.0.49
Type
notification
Status
current
Parent
tmnxChassisNotification
Siblings
228

Syntax

No syntax metadata recorded.

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects
Notification Objects