prtExVc2TxBitCode

RAD-MIB · .1.3.6.1.4.1.164.3.2.3.2.5.1.20

Object

column r/w OctetString
- - - For MP & FCD - - -
              
This object represents 4 parameters, by 2 Octets :
Tx D Bit Code-MSB nibble,
Tx C Bit Code-    nibble,
Tx B Bit Code-    nibble,
Tx A Bit Code-LSB nibble.
              
Each nibble:
0 hex = 0000 = Not Applicable
1 hex = 0001 = M lead
2 hex = 0010 = M lead inverse
3 hex = 0011 = Reverse Polarity
4 hex = 0100 = Metering Pulse
5 hex = 0101 = Forced 1
6 hex = 0110 = Forced 0
7-F hex - not used (invalid values)
This object will be RO if prtExVc2SigProfile is NOT manual.
              
              
- - - For WR II - - -
              
This object represents the following 4 parameters by 2 Octets:
1. On/Off hook signaling transmission mode from the FXS towards the T1/E1 (MSB nibble 1).
2. Default signaling bits that are not in use (nibble 2).
3. Ring Detection signaling transmission mode from the FXO towards the T1/E1(nibble 3).
4. M (Mouth) Signaling transmission mode from the E&M towards the T1/E1(LSB nibble 4). 
              
Each nibble:
	---------------------------------------------------------------------------------------
	Value          On/Off Hook       Default sig.      Ring Detect.        M (Mouth)
	---------------------------------------------------------------------------------------
0 hex = 0000   Not Applicable    Not Applicable.  Not Applicable	   Not Applicable
1 hex = 0001   Tx A bit			 Values 1-3 are	  Tx A bit			   Tx A bit
2 hex = 0010   Tx A bit inverse	 for On/Off Hook  Tx A bit inv.	  	   Tx A bit inv.
3 hex = 0011   Tx B bit			 A,B,A Inv,B Inv. Tx B bit			   Tx B bit
4 hex = 0100   Tx B bit inverse	 Values 4-7 are	  Tx B bit inv.		   Tx B bit inv.
5 hex = 0101   not Used-invalid	 for On/Off Hook  not Used-invalid	   not Used-invalid
6 hex = 0110   not Used-invalid	 A, A Inverse.	  not Used-invalid 	   not Used-invalid
7 hex = 0111   not Used-invalid			 		  not Used-invalid	   not Used-invalid	 
8 hex = 1000   not Used-invalid	 Values 8-11 are  not Used-invalid	   not Used-invalid
9 hex = 1001   not Used-invalid	 for On/Off Hook  not Used-invalid	   not Used-invalid
	A hex = 1010   not used-invalid	 B, B Inverse.	  not Used-invalid	   not Used-invalid
	B hex = 1011   not used-invalid	 The Bits order:  not Used-invalid	   not Used-invalid
C-F hex 	   not used-invalid	 ABCD			  not Used-invalid	   not Used-invalid
              
              
Default value: 11 11

Context

MIB
RAD-MIB
OID
.1.3.6.1.4.1.164.3.2.3.2.5.1.20
Type
column
Access
readwrite
Status
current
Parent
prtVc2CnfgEntry
Table
prtVc2CnfgTable
Siblings
39

Syntax

OctetString

Values & Constraints

Enumerated Values
2restoreT1secFast
3restoreT10sec62411
4ccittE1

Related Objects

Sibling Objects