prtExVc2RxBitOutput

RAD-MIB · .1.3.6.1.4.1.164.3.2.3.2.5.1.21

Object

column r/w OctetString
- - - For MP (VC-Q card only) & FCD - - -
This object represents 3  parameters by 2 Octets:
Spare       -MSB nibble, always=0 hex
E Lead Output          -    nibble,
Reverse Polarity Output-    nibble,
Metering Pulse Output  -LSB nibble.
              
Each nibble:
0 hex = 0000 = Not Applicable
1 hex = 0001 = Rx A bit
2 hex = 0010 = Rx A bit inverse
3 hex = 0011 = Rx B bit
4 hex = 0100 = Rx B bit inverse
5 hex = 0101 = Rx C bit
6 hex = 0110 = Rx C bit inverse
7 hex = 0111 = Rx D bit
8 hex = 1000 = Rx D bit inverse
9 hex = 1001 = none
A-F hex - not used (invalid values)
This object will be RO if prtExVc2SigProfile is NOT manual.
              
- - - For MP (VC-8, VC-16, VC-16A cards) - - - 
              
This object represents 4 parameters, by 2 Octets :
Tx D Bit Code-MSB nibble,
Tx C Bit Code-    nibble,
Tx B Bit Code-    nibble,
Tx A Bit Code-LSB nibble.
              
Each nibble:
0 hex = 0000 = Not Applicable
1 hex = 0001 = not used (invalid value)
2 hex = 0010 = not used (invalid value)
3 hex = 0011 = not used (invalid value)
4 hex = 0100 = not used (invalid value)
5 hex = 0101 = Forced 1
6 hex = 0110 = Forced 0
7-F hex - not used (invalid values)
This object will be RO.
              
                    
- - - For WR II - - -
              
This object represents the following 2 parameters in 1 Octet:
1. On/Off hook signaling receive mode from the T1/E1 into the FXS/FXO (MSB nibble 1).
2. E (Ear) Signaling receive mode from the T1/E1 into the E&M (LSB nibble 2). 
              
Each nibble:
	---------------------------------------------------------------------------------------
	Value          On/Off Hook       E (Ear)
	---------------------------------------------------------------------------------------
0 hex = 0000   Not Applicable    Not Applicable
1 hex = 0001   Rx A bit			 Rx A bit
2 hex = 0010   Rx A bit inverse	 Rx A bit inverse
3 hex = 0011   Rx B bit			 Rx B bit
4 hex = 0100   Rx B bit inverse	 Rx B bit inverse
5-F hex 	   not used-invalid	 not Used-invalid
              
	Default value: 11

Context

MIB
RAD-MIB
OID
.1.3.6.1.4.1.164.3.2.3.2.5.1.21
Type
column
Access
readwrite
Status
current
Parent
prtVc2CnfgEntry
Table
prtVc2CnfgTable
Siblings
39

Syntax

OctetString

Values & Constraints

Enumerated Values
2notsupported
3forcedIdle
4forcedBusy
5busyIdle
6idleBusy

Related Objects