aluRS232HoldTimeDown

ALU-PORT-MIB · .1.3.6.1.4.1.6527.6.1.2.2.2.4.5.1.28

Object

column r/w deci-seconds Unsigned32
The value of aluRS232HoldTimeDown is used to configure the 
hold-timer for link down event dampening. This guards against 
reporting excessive interface transitions. This is implemented 
by not advertising subsequent transitions of the interface to 
upper layer protocols until the configured timer has expired. 
A value of zero (0) indicates that a down transition is reported
immediately.

Context

MIB
ALU-PORT-MIB
OID
.1.3.6.1.4.1.6527.6.1.2.2.2.4.5.1.28
Type
column
Access
readwrite
Status
current
Units
deci-seconds
Parent
aluRS232Entry
Table
aluRS232Table
Siblings
39

Syntax

deci-seconds Unsigned32

Values & Constraints

Object Constraints
range: 0-100

Related Objects

Sibling Objects