aluRS232ControlLeadsSignal

ALU-PORT-MIB · .1.3.6.1.4.1.6527.6.1.2.2.2.4.5.1.29

Object

column OctetString
aluRS232ControlLeadsSignal is an array of byte values used to indicate
the current signal levels of the input and output control leads
(connected to the attached CPE). These values are the ones that get
signalled over the (physical) line. As such, they are sometimes
referred to as LINE-side values.
For network-side values, see aluRS232ControlLeadsState.
              
Each byte in the array represents the signal level of an individual
control lead. The byte order is as follows:
              
    -- DtrDsr (LSB or byte0)
    -- RtsDcdC
    -- AlbCts
    -- RdlRi
    -- DsrDtr
    -- DcdRtsI
    -- CtsAlb
    -- RiRdl (MSB or byte7)
              
A byte value of 1 represents on (or high as per AluRS232ControlLead).
A byte value of 2 represents off (or low as per AluRS232ControlLead).
All other byte values are undefined.
              
A particular byte is undefined if its config counterpart is undefined.
For example, given an X.21 interface, aluRS232ControlLeadDsrDtr is
undefined thus, aluRS232ControlLeadsSignal byte 'DtrDsr' is also
undefined.
              
Some bytes can represent something else depending on the interface
type. For example, given an RS-530, RdlRi represents LlTm.
See the respective object for details (eg. aluRS232ControlLeadRdlRi).

Context

MIB
ALU-PORT-MIB
OID
.1.3.6.1.4.1.6527.6.1.2.2.2.4.5.1.29
Type
column
Access
readonly
Status
current
Parent
aluRS232Entry
Table
aluRS232Table
Siblings
39

Syntax

OctetString

Values & Constraints

Object Constraints
range: 8-8

Related Objects

Sibling Objects