SL-SONET-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
6
Rows
6
Columns
47
.1.3.6.1.4.1.4515.1.6.1.1 · 1 row entry · 18 columns
The SONET/SDH configuration table. This table has objects 
for configuring sonet lines.
slSonetConfigEntry entry .1.3.6.1.4.1.4515.1.6.1.1.1
An entry in the table. There is an entry for each SONET line
in the table. Entries are automatically created for an
ifType value of sonet(39). 'ifAdminStatus' from the ifTable
must be used to enable or disable a line…
Indexes
IF-MIBifIndex
Column Syntax OID
slSonetConfigFrameScramble
This object is used to disable or enable the Scrambling
option in SONET line. Please refer to GR-253-CORE for
frame scrambling.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.4515.1.6.1.1.1.1
slSonetConfigType
This object represents the configured line type for Trunks:
sonetSts48c(5) - 1 x Sts48 (2.5GbTrunk)
sonetSts192c(12) - 1 x Sts192 (10Gb Trunk)
sonetStsOther(13) - for OC-n interfaces see slSonetFsTable.
Enumerationr/w
Enumerated Values:
1sonetSts3
2sonetSts3c
3sonetSts12
4sonetSts12c
5sonetSts48c
6sonetSts3cx4
7sonetSts48
8sonetSts3cx16
9sonetSts3x16
10sonetSts12cx4
11sonetSts12x4
12sonetSts192c
13sonetStsOther
.1.3.6.1.4.1.4515.1.6.1.1.1.2
slSonetConfigDccSelection
This object selects the DCC type.
Enumerationr/w
Enumerated Values:
1sonetLineDcc
2sonetSectionDcc
3sonetInband
.1.3.6.1.4.1.4515.1.6.1.1.1.3
slSonetResetAllCounters
Setting this variable to 1 will cause all of the counters
(performance regsters) on this SONET interface to be initialized
to zero (0).
Enumerationr/w
Enumerated Values:
1resetCounters
.1.3.6.1.4.1.4515.1.6.1.1.1.4
slSonetPortThresholdTrapEnable
This variable indicates whether threshold traps
should be generated for this SONET interface.
Enumerationr/w
Enumerated Values:
1enabled
2disabled
.1.3.6.1.4.1.4515.1.6.1.1.1.5
slSonetConfigSdThreshold
This object contains the Bit Error Rate threshold for
Signal Degrade detection on the working line. Once this
threshold is exceeded, an APS switch will occur.
This value is 10 to -n where n is between 5 and 9
(read-writ…
Integer32r/w
Constraints:
range: 5-9
.1.3.6.1.4.1.4515.1.6.1.1.1.6
slSonetConfigSfThreshold
This object contains the Bit Error Rate threshold for
Signal Fault detection on the working line. Once this
threshold is exceeded, an APS switch will occur.
This value is 10 to the -n, where n is between 3 and 5.
(read-…
Integer32r/w
Constraints:
range: 3-5
.1.3.6.1.4.1.4515.1.6.1.1.1.7
slSonetCompression
This object applies only for trunk ports.
It specifies if the packets should be compressed.
0 - Means no POS compression,
1 - Means POS compression with CRC-32.
2 - Means POS compression with CRC-16.
Note that the two …
Enumerationr/w
Enumerated Values:
0uncompress
1posCompress32
2posCompress16
.1.3.6.1.4.1.4515.1.6.1.1.1.9
slSonetOverheadTunneling
The section and line overhead tunneling configuration:
none(0) - no tunneling support
lineDcc(1) - line DCC tunneling
k1k2(2) - line DCC + protection k byte
full(3) - all transport overhead bytes are tunnel…
Enumerationr/w
Enumerated Values:
0none
1lineDcc
2k1k2
3full
.1.3.6.1.4.1.4515.1.6.1.1.1.10
slSonetLopBitmask
The LOP status. Each bit of the bits represent the status
of the LOP alarm in corresponding STS.
For a path with more than a single STS, only the value of the
first STS in the path is relevant.
This object is relevant o…
SNMPv2-SMICounter64
Textual Convention: SNMPv2-SMICounter64 Unsigned64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.4515.1.6.1.1.1.11
slSonetTdmTrunk
This object is applicable only to the OC-n ports.
TRUE - means that the OC-n port is used as a TDM Trunk.
FLASE - means normal OC-n port.
SNMPv2-TCTruthValuer/w
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.4515.1.6.1.1.1.12
slSonetFsApply
Writing to this object activate the slSonetFsTable setting.
This allow the NMS to do many changes to the slSonetFsTable
and then APPLY them at once. This prevent from going through
unconsistent steps.
This object always…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4515.1.6.1.1.1.13
slSonetTxLte
The SS bits to transmit (bits 5,6 in H1,H1*).
Enumerationr/w
Enumerated Values:
1ssb00
2ssb10
5auto
.1.3.6.1.4.1.4515.1.6.1.1.1.14
slSonetReceivedLte
The detected LTE type, according to the received SS bits
(bits 5,6 in H1,H1*).
Enumeration
Enumerated Values:
1ssb00
2ssb10
3ssb01
4ssb11
5ssbinv
.1.3.6.1.4.1.4515.1.6.1.1.1.15
slSonetResetPmThreshold
Setting this variable to 1 will reset the PM threshold
parameters to the factory defaults.
Enumerationr/w
Enumerated Values:
1resetCounters
.1.3.6.1.4.1.4515.1.6.1.1.1.16
slSonetResetAlsParams
Setting this variable to 1 will reset the ALS
parameters to the factory defaults.
Enumerationr/w
Enumerated Values:
1resetCounters
.1.3.6.1.4.1.4515.1.6.1.1.1.17
slSonetTransceiverType
The tranceiver type.
Enumeration
Enumerated Values:
1none
2shortWave
3longWave
.1.3.6.1.4.1.4515.1.6.1.1.1.18
slSonetTransceiverMedia
The tranceiver media.
Enumeration
Enumerated Values:
1none
2sm
3mm
.1.3.6.1.4.1.4515.1.6.1.1.1.19
.1.3.6.1.4.1.4515.1.6.2.1.1 · 1 row entry · 5 columns
The SONET/SDH Trace table. This table contains 
objects for tracing the sonet section and path.
slSonetTraceEntry entry .1.3.6.1.4.1.4515.1.6.2.1.1.1
An entry in the trace table. Entries exist for active sonet
interfaces. The objects in this table are used to verify
continued connection between the two ends of the line.
Indexes
IF-MIBifIndex
Column Syntax OID
slSonetTraceMode
Determine the Trace Message Mode.
Enumerationr/w
Enumerated Values:
1enable
2disable
3monitoring
.1.3.6.1.4.1.4515.1.6.2.1.1.1.1
slSonetTraceToTransmit
Sonet Trace To Transmit. This is string that
is transmitted to perform Sonet trace
diagnostics. The trace string is repetitively
transmited so that a trace receiving terminal can
verify its continued connection to t…
OctetStringr/w
Constraints:
range: 0-62
.1.3.6.1.4.1.4515.1.6.2.1.1.1.2
slSonetTraceToExpect
Sonet Trace Massage To Expect. The receiving terminal
verifies if the incoming string matches this string.
The value of 'slSonetTraceFailure' indicates whether a
trace mismatch occurred. The default value is a
zero-…
OctetStringr/w
Constraints:
range: 0-62
.1.3.6.1.4.1.4515.1.6.2.1.1.1.3
slSonetTraceFailure
The value of this object is set to 'true' when Sonet
Section received trace does not match the
'slSonetTraceToExpect'.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.4515.1.6.2.1.1.1.4
slSonetTraceReceived
This object is used to view the Sonet Trace Message that
is received by the receiving terminal.
The Agent is responsible to pad the end of the string with <CR><LF>.
OctetString
Constraints:
range: 0-62
.1.3.6.1.4.1.4515.1.6.2.1.1.1.5
.1.3.6.1.4.1.4515.1.6.2.2.1 · 1 row entry · 4 columns
The SONET/SDH Signal Label table. This table contains 
signal label for the sonet path.
slSonetSlEntry entry .1.3.6.1.4.1.4515.1.6.2.2.1.1
An entry in the SONET/SDH Signal Label table. The entries
exist for active sonet lines. The objects in this table are
used to verify continued connection between the two ends of
the line.
Indexes
IF-MIBifIndex
Column Syntax OID
slSonetSlToTransmit
Sonet Signal Label To Transmit.
SignalLabelr/w
Textual Convention: SignalLabel Enumeration
Type Values:
0sigUnequipped
1sigEquipped
2sigPathFloatVt
3sigPathLoackedVt
4sigPathAsynchDs3
5sigPathSyntran
18sigPathAsyncDs4na
19sigPathAtm
20sigPathDqdb
21sigPathFddi
22sigPathHdlc
27sigPathGfp
.1.3.6.1.4.1.4515.1.6.2.2.1.1.2
slSonetSlToExpect
Sonet Signal Label To Expect.
SignalLabelr/w
Textual Convention: SignalLabel Enumeration
Type Values:
0sigUnequipped
1sigEquipped
2sigPathFloatVt
3sigPathLoackedVt
4sigPathAsynchDs3
5sigPathSyntran
18sigPathAsyncDs4na
19sigPathAtm
20sigPathDqdb
21sigPathFddi
22sigPathHdlc
27sigPathGfp
.1.3.6.1.4.1.4515.1.6.2.2.1.1.3
slSonetSlFailure
The value of this object is set to 'true' when Sonet
received signal label does not match the 'slSonetSlToExpect'.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.4515.1.6.2.2.1.1.4
slSonetSlReceived
This object is used to view the Sonet Signal Label that is
received by the receiving terminal.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.4515.1.6.2.2.1.1.5
.1.3.6.1.4.1.4515.1.6.6.1 · 1 row entry · 7 columns
The POS PM Table.
slSonetPosEntry entry .1.3.6.1.4.1.4515.1.6.6.1.1
The entries exist for active Trunk sonet lines
ifType = pos(171). The objects in this table are
used to moitor the POS layer.
Indexes
IF-MIBifIndex
Column Syntax OID
slSonetPosFcs
The Number of FCS Errors.
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4515.1.6.6.1.1.1
slSonetPosAbort
The Number of Aborted packets.
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4515.1.6.6.1.1.2
slSonetPosMinViolation
The Number of Minimum length violation packets.
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4515.1.6.6.1.1.3
slSonetPosMaxViolation
The Number of Maximum length violation packets.
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4515.1.6.6.1.1.4
slSonetPosRxfifoDiscard
The Number of packets discarded due to RXFIFO error.
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4515.1.6.6.1.1.5
slSonetPosPacketReceived
The Number of packets received.
SNMPv2-SMICounter64
Textual Convention: SNMPv2-SMICounter64 Unsigned64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.4515.1.6.6.1.1.6
slSonetPosPacketReceivedOk
The Number of error free packets.
SNMPv2-SMICounter64
Textual Convention: SNMPv2-SMICounter64 Unsigned64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.4515.1.6.6.1.1.7
.1.3.6.1.4.1.4515.1.6.7.1 · 1 row entry · 8 columns
The ALS configuration Table.
slSonetAlsEntry entry .1.3.6.1.4.1.4515.1.6.7.1.1
The entries exist for active sonet lines
ifType = sonet(39). The objects in this table are
used to configure the ALS algorithm.
Indexes
IF-MIBifIndex
Column Syntax OID
slSonetAlsMode
Enable/Disable the ALS algorithm.
Note that the if the Laser Admin Status is 'down' the
ALS mechanism is not operational.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.4515.1.6.7.1.1.1
slSonetLosDeclareTime
Time to declare optical LOS present or clear: 550 +- 50 msec.
Enumerationr/w
Enumerated Values:
1ms500
2ms550
3ms600
.1.3.6.1.4.1.4515.1.6.7.1.1.2
slSonetTestPulseTime
Manual restart for test Pulse time (in manual restart) - 90+-10 sec.
Enumerationr/w
Enumerated Values:
1s80
2s90
3s100
.1.3.6.1.4.1.4515.1.6.7.1.1.3
slSonetManualPulseTime
Manual restart Pulse time (in manual mode) - 2+-0.25 sec.
Enumerationr/w
Enumerated Values:
1ms1750
2ms2000
3ms2250
.1.3.6.1.4.1.4515.1.6.7.1.1.4
slSonetAutomaticPulseTime
Automatic restart Pulse time (in automatic mode) - 2+-0.25 sec.
Enumerationr/w
Enumerated Values:
1ms1750
2ms2000
3ms2250
.1.3.6.1.4.1.4515.1.6.7.1.1.5
slSonetAutomaticDelayTime
In Automatic mode. The delay between two laser re-activations.
Integer32r/w
Constraints:
range: 60-300
.1.3.6.1.4.1.4515.1.6.7.1.1.6
slSonetLaserTestActivate
Activate the laser for test operation.
Enumerationr/w
Enumerated Values:
1activate
.1.3.6.1.4.1.4515.1.6.7.1.1.7
slSonetLaserManualActivate
Activate the laser manual operation.
Enumerationr/w
Enumerated Values:
1activate
.1.3.6.1.4.1.4515.1.6.7.1.1.8
.1.3.6.1.4.1.4515.1.6.8.1 · 1 row entry · 5 columns
The frame structure configuration Table.
In order to define a new path the NMS should create and configure
an entry in this table.
The table is also used to monitor the status of the LOP
alarm per path.
slSonetFsEntry entry .1.3.6.1.4.1.4515.1.6.8.1.1
The entries exist for sonet paths
ifType = sonet(39). The objects in this table are
used to configure the frame structure.
Each OC-N line interface shall maintain a static
table with number of lines equal to the N.
In…
Indexes
slSonetFsIfIndex slSonetFsSts
Column Syntax OID
slSonetFsIfIndex
The interface index.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.4515.1.6.8.1.1.1
slSonetFsSts
The number of the first STS in the path.
Note that no all values are legal because there is no
support for combus with mixed structure
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4515.1.6.8.1.1.2
slSonetFsWidth
The number STS's in the path.
The width is only valid for the first STS in the path.
The other STSs of the path will have width=0.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4515.1.6.8.1.1.3
slSonetFsFullPathTermination
FALSE - means partial path termination (only LOP alarm).
TRUE - include full support for path Alarms and PM counters.
SNMPv2-TCTruthValuer/w
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.4515.1.6.8.1.1.4
slSonetFsGranularity
This value is set by the NMS according to the configured frame structure.
Each VC-3 that is mapped to AUG-1 via VC-4 should have the value vc4(1).
Otherwise the value should be vc3(2).
Enumerationr/w
Enumerated Values:
1vc4
2vc3
.1.3.6.1.4.1.4515.1.6.8.1.1.5