slSonetAutomaticPulseTime
SL-SONET-MIB ·
.1.3.6.1.4.1.4515.1.6.7.1.1.5
Object
column
r/w
Enumeration
Automatic restart Pulse time (in automatic mode) - 2+-0.25 sec.
Context
- MIB
- SL-SONET-MIB
- OID
.1.3.6.1.4.1.4515.1.6.7.1.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- slSonetAlsEntry
- Table
- slSonetAlsTable
- Siblings
- 7
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | ms1750 |
2 | ms2000 |
3 | ms2250 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| slSonetAlsMode Enable/Disable the ALS algorithm.
Note that the if the Laser Admin Status is 'down' the
ALS mechanism is not operational. | column | Enumeration | .1.3.6.1.4.1.4515.1.6.7.1.1.1 |
| slSonetLosDeclareTime Time to declare optical LOS present or clear: 550 +- 50 msec. | column | Enumeration | .1.3.6.1.4.1.4515.1.6.7.1.1.2 |
| slSonetTestPulseTime Manual restart for test Pulse time (in manual restart) - 90+-10 sec. | column | Enumeration | .1.3.6.1.4.1.4515.1.6.7.1.1.3 |
| slSonetManualPulseTime Manual restart Pulse time (in manual mode) - 2+-0.25 sec. | column | Enumeration | .1.3.6.1.4.1.4515.1.6.7.1.1.4 |
| slSonetAutomaticDelayTime In Automatic mode. The delay between two laser re-activations. | column | Integer32 | .1.3.6.1.4.1.4515.1.6.7.1.1.6 |
| slSonetLaserTestActivate Activate the laser for test operation. | column | Enumeration | .1.3.6.1.4.1.4515.1.6.7.1.1.7 |
| slSonetLaserManualActivate Activate the laser manual operation. | column | Enumeration | .1.3.6.1.4.1.4515.1.6.7.1.1.8 |