ATEN-PE2-CFG Table View

Table-centric layout grouping table, row, and column objects.

Tables
38
Rows
38
Columns
162
.1.3.6.1.4.1.21317.1.3.2.3.1.2 · 1 row entry · 10 columns
Station status table.
staStatusEntry entry .1.3.6.1.4.1.21317.1.3.2.3.1.2.1
Single entry containing station status info.
Indexes
staId
Column Syntax OID
staId
Station ID.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.1
staStatusFWVer
Station FW version.
If the station is not available, it returns 'station N/A'.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.2
staStatusModelName
Station model name.
If the station is not available, it returns 'station N/A'
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.3
staStatusSwitchable
Outlets of the station are switchable or not.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
-3000000staNotAvailable
1no
2yes
3mix
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.4
staStatusPerPortReading
Outlets of the station are per-port reading or not.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
-3000000staNotAvailable
1no
2yes
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.5
staStatusBankCount
Station bank count.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.6
staStatusOutletCount
Station outlet count.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.7
staStatusSensorCount
Station sensor count.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.8
staStatusHasAutoPing
The station supports auto-ping or not.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
-3000000staNotAvailable
1no
2yes
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.9
staStatusInletCount
Station inlet count.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.10
.1.3.6.1.4.1.21317.1.3.2.3.1.3 · 1 row entry · 1 columns
Station control table.
staControlEntry entry .1.3.6.1.4.1.21317.1.3.2.3.1.3.1
Single entry containing station control info.
Indexes
staId
Column Syntax OID
staControlReboot
Reboot the station.
If the station is not available, it returns value -3000000.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1no
2yes
4not-support
.1.3.6.1.4.1.21317.1.3.2.3.1.3.1.1
.1.3.6.1.4.1.21317.1.3.2.3.1.4 · 1 row entry · 3 columns
Rack config table.
rackConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.1.4.1
Single entry containing rack config info.
Indexes
staId
Column Syntax OID
rackConfigName
Display or set station's rack name.
string length: 1~32
If the station is not available, it returns 'station N/A'.
NOTE: Input string as /empty to set this object to NULL.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.21317.1.3.2.3.1.4.1.1
rackConfigRow
Display or set station's rack row number.
If the station is not available, it returns value -3000000.
Integer32r/w
Constraints:
range: 1-26
.1.3.6.1.4.1.21317.1.3.2.3.1.4.1.2
rackConfigColumn
Display or set station's rack column number.
If the station is not available, it returns value -3000000.
Integer32r/w
Constraints:
range: 1-26
.1.3.6.1.4.1.21317.1.3.2.3.1.4.1.3
.1.3.6.1.4.1.21317.1.3.2.3.2.1.1 · 1 row entry · 4 columns
Device status table.
devStatusEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.1.1.1
Single entry containing device status info.
Indexes
staId
Column Syntax OID
devStatusRatedCur
Device input Current value. unit:(0.1mA)
If the station does not support this OID, we show value 0.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.1.1.1.1
devStatusRatedVol
Device input Voltage value. unit:(0.1mV)
If the station does not support this OID, we show value 0.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.1.1.1.2
devStatusRatedPower
Device power Capacity value. unit:(0.1mVA)
If the station does not support this OID, we show value 0.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.1.1.1.3
devStatusWiredType
Device circuit wired type
Example: 1 for 1 phase, 2 for 3 phase wye, 3 for 3 phase delta
If the station does not support this OID, we show value 0.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.1.1.1.4
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2 · 1 row entry · 10 columns
Device config table.
devConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1
Single entry containing device config info.
Indexes
staId
Column Syntax OID
devConfigDevName
The name of the device.
string length: 1~39
If the station is not available, it returns 'station N/A'.
NOTE: Input string as /empty to set this object to NULL.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.1
devConfigPowerOnScheduleEn
Display or set whether power on schedule or not.
If the station is not available, it returns value -3000000.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1no-delaytime
2delaytime
3not-support
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.2
devConfigOutletsSequentialRebootEn
This function is used to enable or disable all outlet ports to sequential reboot.
If the station is not available, it returns value -3000000.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1no
2yes
3not-support
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.3
devConfigMinCurThresh
Display or set device minimum electric current measurement threshold.
Example: range 0.0~32.0 represents 0~320.
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.4
devConfigMaxCurThresh
Display or set device maximum electric current measurement threshold.
Example: range 0.0~32.0 represents 0~320
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station doe…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.5
devConfigMinVolThresh
Display or set device minimum voltage measurement threshold.
Example: range 90.0~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does not…
Integer32r/w
Constraints:
range: -3000--3000
range: 900-2600
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.6
devConfigMaxVolThresh
Display or set device maximum voltage measurement threshold.
Example: range 90.0~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does not…
Integer32r/w
Constraints:
range: -3000--3000
range: 900-2600
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.7
devConfigMinPowerThresh
Display or set device minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does not …
Integer32r/w
Constraints:
range: -3000--3000
range: 0-99999
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.8
devConfigMaxPowerThresh
Display or set device maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does not …
Integer32r/w
Constraints:
range: -3000--3000
range: 0-99999
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.9
devConfigMaxPDThresh
Display or set device maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the sta…
Integer32r/w
Constraints:
range: -3000--3000
range: 0-999990
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.10
.1.3.6.1.4.1.21317.1.3.2.3.2.1.3 · 1 row entry · 1 columns
Device control table.
devControlEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.1.3.1
Single entry containing device control info.
Indexes
staId
Column Syntax OID
devControlOperation
This function is used for outlet control of device.
Set off(1) to turn off for outlet control of device.
Set on(2) to turn on for all outlet control of device.
Set reboot(3) to reboot for outlet control of device.
Get t…
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1off
2on
3reboot
4nostatus
5not-support
.1.3.6.1.4.1.21317.1.3.2.3.2.1.3.1.1
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4 · 1 row entry · 5 columns
Device reading table.
devReadingEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1
Single entry containing device reading info.
Indexes
staId
Column Syntax OID
devReadingCur
Device electric current value.
This value indicates that 10,000 times.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.1
devReadingVol
Device voltage value.
This value indicates that 10,000 times.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.2
devReadingPower
Device power value.
This value indicates that 10,000 times.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.3
devReadingPD
Device power dissipation value.
This value indicates that 10,000 times.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.4
devReadingPF
Device power factor value.
This value indicates that 100 times.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.5
.1.3.6.1.4.1.21317.1.3.2.3.2.1.5 · 1 row entry · 4 columns
POP config table.
popConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.1.5.1
Single entry containing POP config info.
Indexes
staId
Column Syntax OID
popConfigOutletModeEn
Display or set whether outlet POP mode is enabled or not.
If the station is not available, it returns value -3000000.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1no
2yes
3not-support
.1.3.6.1.4.1.21317.1.3.2.3.2.1.5.1.1
popConfigLIFOModeEn
Display or set whether LIFO POP mode is enabled or not.
If the station is not available, it returns value -3000000.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1no
2yes
3not-support
.1.3.6.1.4.1.21317.1.3.2.3.2.1.5.1.2
popConfigPriorityModeEn
Display or set whether priority POP mode is enabled or not.
If the station is not available, it returns value -3000000.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1no
2yes
3not-support
.1.3.6.1.4.1.21317.1.3.2.3.2.1.5.1.3
popConfigPriorityList
Indicate Outlets' power OFF priorities under Priority POP mode.
Outlet Separator ','
Bank Separator '#'
Assign each priority in each bank by Outlet index or zero (indicate N/A) with separators in ascendant order.
e.g. f…
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.21317.1.3.2.3.2.1.5.1.4
.1.3.6.1.4.1.21317.1.3.2.3.2.1.6 · 1 row entry · 1 columns
CAP config table.
capConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.1.6.1
Single entry containing CAP config info.
Indexes
staId outletId
Column Syntax OID
capConfigModeEn
Display or set whether CAP mode is enabled or not.
If the station is not available, it returns value -3000000.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1no
2yes
.1.3.6.1.4.1.21317.1.3.2.3.2.1.6.1.1
.1.3.6.1.4.1.21317.1.3.2.3.2.1.7 · 1 row entry · 1 columns
CAP priority config table.
capPriorityConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.1.7.1
Single entry containing CAP priority config info.
Indexes
staId outletId
Column Syntax OID
capPriorityConfigOutlet
Display or set the CAP Priority of outlet.
Priority 0 means this outlet does not support this OID.
If the station is not available, it returns value -3000000.
Integer32r/w
Constraints:
range: 0-99
.1.3.6.1.4.1.21317.1.3.2.3.2.1.7.1.1
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1 · 1 row entry · 5 columns
Bank status table.
bankStatusEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1
Single entry containing bank status info.
Indexes
staId bankId
Column Syntax OID
bankId
Bank ID.
Integer32
Constraints:
range: 1-30
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.1
bankStatusRatedCur
The Bank Max Current value. unit: (0.1mA).
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.2
bankStatusAttachStatus
The bank attached status.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
-3000000staNotAvailable
1noattached
2attached
3error
4noexisted
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.3
bankStatusBreakerStatus
The breaker status.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
-3000000staNotAvailable
1off
2on
3not-support
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.4
bankStatusPhaseLayout
Display the phase layout of bank.
Example: range 1 ~ 3 represents Line1-LineNeutral ~ Line3-lineNeutral.
4 ~ 6 represents Line1-Line2, Line2-Line3, Line3-Line1.
If the station does not support this OID, it retur…
Enumeration
Enumerated Values:
-3000000staNotAvailable
-2000000not-support
1l1-n
2l2-n
3l3-n
4l1-l2
5l2-l3
6l3-l1
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.5
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2 · 1 row entry · 8 columns
Bank config table.
bankConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1
Single entry containing bank config info.
Indexes
staId bankId
Column Syntax OID
bankConfigName
Display or set the name of the bank.
When this model does not support the OID, we show n/a.
string length: 0~15
If the station is not available, it returns 'station N/A'.
NOTE: Input string as /empty to set this object …
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.1
bankConfigMinCurThresh
Display or set the bank minimum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station d…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.2
bankConfigMaxCurThresh
Display or set the bank maximum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station d…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.3
bankConfigMinVolThresh
Display or set the bank minimum voltage measurement threshold.
Example: range 90.0 ~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does …
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 900-2600
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.4
bankConfigMaxVolThresh
Display or set the bank maximum voltage measurement threshold.
Example: range 90.0 ~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does …
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 900-2600
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.5
bankConfigMinPowerThresh
Display or set the bank minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does not…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-99999
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.6
bankConfigMaxPowerThresh
Display or set the bank maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does not…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-99999
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.7
bankConfigMaxPDThresh
Display or set the bank maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the st…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-999990
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.8
.1.3.6.1.4.1.21317.1.3.2.3.2.2.3 · 1 row entry · 1 columns
Bank control table.
bankControlEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.2.3.1
Single entry containing bank control info.
Indexes
staId bankId
Column Syntax OID
bankControlOperation
This function is used for outlet control of bank.
Set off(1) to turn off for outlet control of bank.
Set on(2) to turn on for all outlet control of bank.
Set reboot(3) to reboot for outlet control of bank.
Get this obje…
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1off
2on
3reboot
4nostatus
5not-support
.1.3.6.1.4.1.21317.1.3.2.3.2.2.3.1.1
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4 · 1 row entry · 5 columns
Bank reading table.
bankReadingEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1
Single entry containing bank reading info.
Indexes
staId bankId
Column Syntax OID
bankReadingCur
Bank electric current value.
This value indicates that 10,000 times.
If this measurement value is not available, it returns value -1000000.
If the station does not support this OID, it returns value -2000000.
If the sta…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.1
bankReadingVol
Bank voltage value.
This value indicates that 10,000 times.
If this measurement value is not available, it returns value -1000000.
If the station does not support this OID, it returns value -2000000.
If the station is n…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.2
bankReadingPower
Bank power value.
This value indicates that 10,000 times.
If this measurement value is not available, it returns value -1000000.
If the station does not support this OID, it returns value -2000000.
If the station is not…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.3
bankReadingPD
Bank power dissipation value.
This value indicates that 10,000 times.
If this measurement value is not available, it returns value -1000000.
If the station does not support this OID, it returns value -2000000.
If the st…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.4
bankReadingPF
Bank power Factor value.
This value indicates that 100 times.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.5
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1 · 1 row entry · 5 columns
Outlet status table.
outletStatusEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1
Single entry containing outlet status info.
Indexes
staId outletId
Column Syntax OID
outletId
Outlet ID.
Integer32
Constraints:
range: 1-42
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.1
outletStatusRatedCur
Outlet Max Current value. unit: (0.1mA).
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.2
outletStatusSwitchable
Outlet switchable.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
-3000000staNotAvailable
-2000000not-support
1no
2yes
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.3
outletStatusAutoPing
Outlet latest auto-ping result.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
-3000000staNotAvailable
-2000000not-support
1na
2online
3not-reachable
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.4
outletStatusPhaseLayout
Display the phase layout of outlet.
Example: range 1 ~ 3 represents Line1-LineNeutral ~ Line3-lineNeutral.
4 ~ 6 represents Line1-Line2, Line2-Line3, Line3-Line1.
If the station does not support this OID, it retur…
Enumeration
Enumerated Values:
-3000000staNotAvailable
-2000000not-support
1l1-n
2l2-n
3l3-n
4l1-l2
5l2-l3
6l3-l1
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.5
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2 · 1 row entry · 21 columns
Outlet config table.
outletConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1
Single entry containing outlet config info.
Indexes
staId outletId
Column Syntax OID
outletConfigName
Display or set the name of the outlet.
If the station does not support this OID, we show n/a.
string length: 0~48
If the station is not available, it returns 'station N/A'.
NOTE: Input string as /empty to set this ob…
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.1
outletConfigConfirmationEn
Display or set the confirmation of the outlet.
If the station is not available, it returns value -3000000.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1no
2yes
3noauth
4not-support
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.2
outletConfigOnDelayTime
Display or set the ON delay time of the outlet.
When this model does not support the OID, we show value -1.
If the station is not available, it returns value -3000000.
Integer32r/w
Constraints:
range: -1-999
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.3
outletConfigOffDelayTime
Display or set the OFF delay time of the outlet.
When this model does not support the OID, we show value -1.
If the station is not available, it returns value -3000000.
Integer32r/w
Constraints:
range: -1-999
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.4
outletConfigShutdownMethod
Display or set the shutdown method of the outlet.
If the station is not available, it returns value -3000000.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1kill-the-power
2wake-on-lan
3after-ac-back
4not-support
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.5
outletConfigMAC
Display or set the MAC address of shutdown method.
The value is hex format with length 12.
If the station does not support this OID, it return '00-00-00-00-00-00'.
If the station is not available, it returns '00-00-00-0…
SNMPv2-TCMacAddressr/w
Textual Convention: SNMPv2-TCMacAddress OctetString
Type Constraints:
range: 6
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.6
outletConfigLocalAccessLock
Display or set whether the local access of the outlet is locked by remote or not.
If the station is not available, it returns value -3000000.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1unlocked
2locked
3not-support
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.7
outletConfigMinCurThresh
Display or set the outlet minimum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.8
outletConfigMaxCurThresh
Display or set the outlet maximum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.9
outletConfigMinVolThresh
Display or set the outlet minimum voltage measurement threshold.
Example: range 90.0 ~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station doe…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 900-2600
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.10
outletConfigMaxVolThresh
Display or set the outlet maximum voltage measurement threshold.
Example: range 90.0 ~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station doe…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 900-2600
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.11
outletConfigMinPowerThresh
Display or set the outlet minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does n…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-99999
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.12
outletConfigMaxPowerThresh
Display or set the outlet maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does n…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-99999
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.13
outletConfigMaxPDThresh
Display or set the outlet maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the …
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-999990
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.14
outletConfigAutoPingContFailTimes
Display or set the outlet auto-ping continuously-failed time to reset outlet.
Example: range 0 ~ 5
Empty value: -3000.
If the station does not support this OID, it returns value -2000000.
If the station is not available…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-10
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.15
outletConfigAutoPingIntervalSec
Display or set the outlet auto-ping pinging interval in seconds.
Example: range 10 ~ 600
Empty value: -3000.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it retur…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-60
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.16
outletConfigAutoPingRetryTimes
Display or set the outlet auto-ping max retry times.
Example: range 0 ~ 5
Empty value: -3000.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -30000…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-10
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.17
outletConfigAutoPingPowerUpDelaySec
Display or set the outlet auto-ping first-ping-delay in seconds after outlet switches on.
Example: range 10 ~ 600
Empty value: -3000.
If the station does not support this OID, it returns value -2000000.
If the station i…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-60
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.18
outletConfigAutoPingRemoteIPAddr
Outlet auto-ping destination IP address.
If the station does not support this OID, it returns value '0.0.0.0'.
If the station is not available, it returns '0.0.0.0'.
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.19
outletConfigAutoPingEnable
Display or set the outlet auto-ping enable state.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
-2000000not-support
1disable
2enable
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.20
outletConfigAutoPingEnableReboot
Display or set the outlet auto-ping reboot enable state.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
-2000000not-support
1disable
2enable
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.21
.1.3.6.1.4.1.21317.1.3.2.3.2.3.3 · 1 row entry · 1 columns
Outlet control table.
outletControlEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.3.3.1
Single entry containing outlet control info.
Indexes
staId outletId
Column Syntax OID
outletControlOperation
This function is used for the outlet control.
Set off(1) to turn off the outlet.
Set on(2) to turn on the outlet.
Set reboot(3) to reboot the outlet.
pending(3), fault(5), noauth(6), not-suport(7), pop(8) can't be set.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1off
2on
3pending
4reboot
5fault
6noauth
7not-support
8pop
.1.3.6.1.4.1.21317.1.3.2.3.2.3.3.1.1
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4 · 1 row entry · 5 columns
Outlet reading table.
outletReadingEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1
Single entry containing outlet reading info.
Indexes
staId outletId
Column Syntax OID
outletReadingCur
Outlet electric current value.
This value indicates that 10,000 times.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.1
outletReadingVol
Outlet voltage value.
This value indicates that 10,000 times.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.2
outletReadingPower
Outlet power value.
This value indicates that 10,000 times.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.3
outletReadingPD
Outlet power dissipation value.
This value indicates that 10,000 times.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.4
outletReadingPF
Outlet Power Factor value.
This value indicates that 100 times.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.5
.1.3.6.1.4.1.21317.1.3.2.3.2.3.5 · 1 row entry · 2 columns
Outlet auto-ping table.
outletAutoPingIpEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.3.5.1
Single entry containing outlet auto-ping ip info.
Indexes
staId outletId
Column Syntax OID
outletConfigAutoPingRemoteIPType
Represents the type of the corresponding instance
of outletConfigAutoPingRemoteIP object.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
1ipv4
2ipv6
.1.3.6.1.4.1.21317.1.3.2.3.2.3.5.1.1
outletConfigAutoPingRemoteIP
Outlet auto-ping destination IP address.
If the station does not support this OID, it returns value '0.0.0.0'.
If the station is not available, it returns '0.0.0.0'.
INET-ADDRESS-MIBInetAddressr/w
Textual Convention: INET-ADDRESS-MIBInetAddress OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21317.1.3.2.3.2.3.5.1.2
.1.3.6.1.4.1.21317.1.3.2.3.2.4.1 · 1 row entry · 2 columns
Line status table.
lineStatusEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.4.1.1
Single entry containing line status info.
Indexes
staId lineId
Column Syntax OID
lineId
Line ID.
Integer32
Constraints:
range: 1-3
.1.3.6.1.4.1.21317.1.3.2.3.2.4.1.1.1
lineStatusRatedCur
The Max Line Current value. unit: (0.1mA)
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.4.1.1.2
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2 · 1 row entry · 6 columns
Line config table.
lineConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1
Single entry containing line config info.
Indexes
staId lineId
Column Syntax OID
lineConfigMinCurThresh
Display or set the line Minimum current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does not s…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.1
lineConfigMaxCurThresh
Display or set the line Maximum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station d…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.2
lineConfigMinVolThresh
Display or set the line minimum voltage measurement threshold.
Example: range 90.0 ~380.0 represents 900~3800
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does …
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 900-3800
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.3
lineConfigMaxVolThresh
Display or set the line maximum voltage measurement threshold.
Example: range 90.0 ~380.0 represents 900~3800
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does …
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 900-3800
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.4
lineConfigMinPowerThresh
Display or set the line minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does not…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-99999
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.5
lineConfigMaxPowerThresh
Display or set the line maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does not…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-99999
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.6
.1.3.6.1.4.1.21317.1.3.2.3.2.4.3 · 1 row entry · 3 columns
Line reading table.
lineReadingEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.4.3.1
Single entry containing line reading info.
Indexes
staId lineId
Column Syntax OID
lineReadingCur
Line current value.
This value indicates that 10,000 times.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.4.3.1.1
lineReadingVol
Line voltage value.
This value indicates that 10,000 times.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.4.3.1.2
lineReadingPower
Line power value.
This value indicates that 10,000 times.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.4.3.1.3
.1.3.6.1.4.1.21317.1.3.2.3.2.4.4 · 1 row entry · 1 columns
Line reading table.
neutralStatusEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.4.4.1
Single entry containing line reading info.
Indexes
staId
Column Syntax OID
neutralStatusLeakageCur
Neutral leakage current status.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
-3000000staNotAvailable
1no-detection
2detection
3not-support
.1.3.6.1.4.1.21317.1.3.2.3.2.4.4.1.1
.1.3.6.1.4.1.21317.1.3.2.3.2.5.1 · 1 row entry · 2 columns
Inlet status table.
inletStatusEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.5.1.1
Single entry containing inlet status info.
Indexes
staId inletId
Column Syntax OID
inletId
Line ID.
Integer32
Constraints:
range: 1-3
.1.3.6.1.4.1.21317.1.3.2.3.2.5.1.1.1
inletStatusRatedCur
The Inlet Max Current value. unit: (0.1mA).
If device is phase wye, then means L1 or L2 or L3 current.
If device is phase delta, then means L1L2 or L2L3 or L3L1 current.
If the station does not support this OID, it retu…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.5.1.1.2
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2 · 1 row entry · 7 columns
Inlet config table.
inletConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1
Single entry containing inlet config info.
Indexes
staId inletId
Column Syntax OID
inletConfigMinCurThresh
Display or set the inlet Minimum current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does not …
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.1
inletConfigMaxCurThresh
Display or set the inlet Maximum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station …
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.2
inletConfigMinVolThresh
Display or set the inlet minimum voltage measurement threshold.
Example: range 90.0 ~380.0 represents 900~3800
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 900-3800
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.3
inletConfigMaxVolThresh
Display or set the inlet maximum voltage measurement threshold.
Example: range 90.0 ~380.0 represents 900~3800
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 900-3800
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.4
inletConfigMinPowerThresh
Display or set the inlet minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does no…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-99999
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.5
inletConfigMaxPowerThresh
Display or set the inlet maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does no…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-99999
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.6
inletConfigMaxPDThresh
Display or set the inlet maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the s…
Integer32r/w
Constraints:
range: -2000000--2000000
range: -3000--3000
range: 0-999990
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.7
.1.3.6.1.4.1.21317.1.3.2.3.2.5.3 · 1 row entry · 4 columns
Inlet reading table.
inletReadingEntry entry .1.3.6.1.4.1.21317.1.3.2.3.2.5.3.1
Single entry containing inlet reading info.
Indexes
staId inletId
Column Syntax OID
inletReadingCur
Inlet current value.
If device is phase wye, then means L1 or L2 or L3 current.
If device is phase delta, then means L1L2 or L2L3 or L3L1 current.
This value indicates that 10,000 times.
If the station does not support …
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.5.3.1.1
inletReadingVol
Inlet voltage value.
If device is phase wye, then means L1 or L2 or L3 voltage.
If device is phase delta, then means L1L2 or L2L3 or L3L1 voltage.
This value indicates that 10,000 times.
If the station does not support …
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.5.3.1.2
inletReadingPower
Inlet power value.
If device is phase wye, then means L1 or L2 or L3 power.
If device is phase delta, then means L1L2 or L2L3 or L3L1 power.
This value indicates that 10,000 times.
If the station does not support this O…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.5.3.1.3
inletReadingPD
Inlet power value.
If device is phase wye, then means L1 or L2 or L3 power dissipation.
If device is phase delta, then means L1L2 or L2L3 or L3L1 power dissipation.
This value indicates that 10,000 times.
If the station…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.2.5.3.1.4
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3 · 1 row entry · 8 columns
Sensor config table.
Use port/addr as indexes to access sensor configurations.
sensorConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1
Single entry containing sensor config info.
Indexes
staId sensorPort sensorAddr
Column Syntax OID
sensorPort
Sensor Port Number.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.1
sensorAddr
Sensor Address.
Integer32
Constraints:
range: 1-31
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.2
sensorConfigMinTempThresh
Display or set sensor minimum temperature measurement threshold.
Example: range -20.0 ~ 60.0 represents -200~600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station doe…
Integer32r/w
Constraints:
range: -3000--3000
range: -200-600
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.3
sensorConfigMaxTempThresh
Display or set sensor maximum temperature measurement threshold.
Example: range -20.0 ~ 60.0 represents -200~600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station doe…
Integer32r/w
Constraints:
range: -3000--3000
range: -200-600
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.4
sensorConfigMinHumThresh
Display or set sensor minimum humidity measurement threshold.
Example: range 10.0 ~ 95.0 represents 100~950
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does not…
Integer32r/w
Constraints:
range: -3000--3000
range: 100-950
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.5
sensorConfigMaxHumThresh
Display or set sensor maximum humidity measurement threshold.
Example: range 10.0 ~ 95.0 represents 100~950
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station does not…
Integer32r/w
Constraints:
range: -3000--3000
range: 100-950
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.6
sensorConfigMinPressThresh
Display or set sensor minimum pressure measurement threshold.
Example: range -250.0 ~ 250.0 represents -2500 ~ 2500
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station …
Integer32r/w
Constraints:
range: -3000--3000
range: -2500-2500
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.7
sensorConfigMaxPressThresh
Display or set sensor maximum pressure measurement threshold.
Example: range -250.0 ~ 250.0 represents -2500 ~ 2500
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empty value: -3000.
If the station …
Integer32r/w
Constraints:
range: -3000--3000
range: -2500-2500
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.8
.1.3.6.1.4.1.21317.1.3.2.3.3.1.4 · 1 row entry · 3 columns
Sensor reading table.
Use port/addr as indexes to access sensor readings.
sensorReadingEntry entry .1.3.6.1.4.1.21317.1.3.2.3.3.1.4.1
Single entry containing sensor reading info.
Indexes
staId sensorPort sensorAddr
Column Syntax OID
sensorReadingTemp
Sensor's Temperature value.
This value indicates that 1,000 times.
If this measurement value is not available, it returns value -1000000.
If the station does not support this OID, it returns value -2000000.
If the stati…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.3.1.4.1.1
sensorReadingHum
Sensor's Humidity value.
This value indicates that 1,000 times.
If this measurement value is not available, it returns value -1000000.
If the station does not support this OID, it returns value -2000000.
If the station …
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.3.1.4.1.2
sensorReadingPress
Sensor's Pressure value.
This value indicates that 1,000 times.
If this measurement value is not available, it returns value -1000000.
If the station does not support this OID, it returns value -2000000.
If the station …
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.21317.1.3.2.3.3.1.4.1.3
.1.3.6.1.4.1.21317.1.3.2.3.3.2.1 · 1 row entry · 2 columns
Dry contact status table.
dryContactStatusEntry entry .1.3.6.1.4.1.21317.1.3.2.3.3.2.1.1
Single entry containing dry contact status info.
Indexes
staId dryContactId
Column Syntax OID
dryContactId
Dry contact ID.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.21317.1.3.2.3.3.2.1.1.1
dryContactStatus
Display dry contact status.
close(0) represents door close.
open(1) represents door open.
not-attached(2) represents door sensor don't attach to device.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
-3000000staNotAvailable
0close
1open
2not-attached
10not-support
.1.3.6.1.4.1.21317.1.3.2.3.3.2.1.1.2
.1.3.6.1.4.1.21317.1.3.2.3.3.2.2 · 1 row entry · 1 columns
Dry contact config table.
dryContactConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.3.2.2.1
Single entry containing dry contact config info.
Indexes
staId dryContactId
Column Syntax OID
dryContactConfigType
Display or set dry contact type.
If the station is not available, it returns value -3000000.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
0notinstalled
1photo
2inductiveproximity
3reed
4waterleakage
5smoke
10not-support
.1.3.6.1.4.1.21317.1.3.2.3.3.2.2.1.1
.1.3.6.1.4.1.21317.1.3.2.3.4.1 · 1 row entry · 1 columns
Net status table.
netStatusEntry entry .1.3.6.1.4.1.21317.1.3.2.3.4.1.1
Single entry containing net status info.
Indexes
staId
Column Syntax OID
netStatusMAC
Station MAC address.
The value is hex format with length 12.
If the station does not support this OID, it return '00-00-00-00-00-00'.
If the station is not available, it returns '00-00-00-00-00-00'.
SNMPv2-TCMacAddress
Textual Convention: SNMPv2-TCMacAddress OctetString
Type Constraints:
range: 6
.1.3.6.1.4.1.21317.1.3.2.3.4.1.1.1
.1.3.6.1.4.1.21317.1.3.2.3.4.2 · 1 row entry · 3 columns
HTTP config table.
httpConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.4.2.1
Single entry containing HTTP config info.
Indexes
staId
Column Syntax OID
httpConfigHttpPort
Display or set the HTTP port of the station.
If the station is not available, it returns value -3000000.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.21317.1.3.2.3.4.2.1.1
httpConfigHttpsPort
Display or set the HTTPs port of the station.
If the station is not available, it returns value -3000000.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.21317.1.3.2.3.4.2.1.2
httpConfigHttpsOnlyEn
Display or set whether to use HTTPS only or HTTP/HTTPS for the web page.
If the station is not available, it returns value -3000000.
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1no
2yes
.1.3.6.1.4.1.21317.1.3.2.3.4.2.1.3
.1.3.6.1.4.1.21317.1.3.2.3.4.3 · 1 row entry · 8 columns
Net config table.
netConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.4.3.1
Single entry containing net config info.
Indexes
staId netCablePort
Column Syntax OID
netCablePort
Network Port Number.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.1
netConfigAutoIP
Display or set IPv4 address automatically or not
Enumerationr/w
Enumerated Values:
1no
2yes
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.2
netConfigIPv4
Display or set fixed IPv4 address
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.3
netConfigSubMask
Display or set subnet mask address
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.4
netConfigGateway
Display or set gateway address
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.5
netConfigAutoDNS
Display or set DNS address automatically or not
Enumerationr/w
Enumerated Values:
1no
2yes
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.6
netConfigPreferDNSIPv4
Display or set prefer DNS address
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.7
netConfigAlterDNSIPv4
Display or set alternate DNS address
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.8
.1.3.6.1.4.1.21317.1.3.2.3.5.1.1 · 1 row entry · 2 columns
Trap config table.
trapConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.5.1.1.1
Single entry containing trap config info.
Indexes
staId
Column Syntax OID
trapConfigEn
Display or set whether this trap entry is enabled or not.
You should set the username/auth-password/priv-password first, when choosing snmpv3.
You should set the community string first, when choosing snmpv1/v2c.
If the …
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1no
2yes
.1.3.6.1.4.1.21317.1.3.2.3.5.1.1.1.1
trapConfigVer
Display or set SNMP trap version for sending trap.
You should set the username/auth-password/priv-password first, when choosing snmpv3.
You should set the community string first, when choosing snmpv1/v2c.
If the station…
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1v1
2v2c
3v3
.1.3.6.1.4.1.21317.1.3.2.3.5.1.1.1.2
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2 · 1 row entry · 7 columns
SNMP agent trap setup table. If users want to use trap, 
they must set enable trap, IP and community first.
trapReceiverConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1
Single entry containing trap receiver config info.
Indexes
staId trapReceiverConfigIdx
Column Syntax OID
trapReceiverConfigIdx
Index of trap receiver.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.1
trapReceiverConfigIp
Trap receiver IP address.
If the station does not support this OID, it returns value '0.0.0.0'.
If the station is not available, it returns '0.0.0.0'.
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.2
trapReceiverConfigPort
NMS trap port to be used by agent to send trap.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.3
trapReceiverConfigCommunity
If use SNMPv1/v2c to receive trap should set this community string.
MAX string length: 20
If the station does not support this OID, it returns value 'not-support'.
If the station is not available, it returns 'station N/…
OctetStringr/w
Constraints:
range: 0-20
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.4
trapReceiverConfigUsername
If use SNMPv3 to receive trap should set this username string.
MAX string length: 20.
If the station does not support this OID, it returns value 'not-support'.
If the station is not available, it returns 'station N/A'.
OctetStringr/w
Constraints:
range: 0-20
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.5
trapReceiverConfigAuthPwd
If use SNMPv3 to receive trap should set this auth password string.
MAX string length: 20
If the station does not support this OID, it returns value 'not-support'.
If the station is not available, it returns 'station N/…
OctetStringr/w
Constraints:
range: 8-20
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.6
trapReceiverConfigPrivacyPwd
If use SNMPv3 to receive trap should set this privacy password string.
MAX string length: 20
If the station does not support this OID, it returns value 'not-support'.
If the station is not available, it returns 'station…
OctetStringr/w
Constraints:
range: 8-20
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.7
.1.3.6.1.4.1.21317.1.3.2.3.5.1.3 · 1 row entry · 3 columns
Trap Receiver Ip table.
trapReceiverIpEntry entry .1.3.6.1.4.1.21317.1.3.2.3.5.1.3.1
Single entry containing trap receiver ip info.
Indexes
staId trapReceiverIpIdx
Column Syntax OID
trapReceiverIpIdx
Index of trap receiver.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.21317.1.3.2.3.5.1.3.1.1
trapReceiverIpType
Represents the type of the corresponding instance
of trapReceiverIp object.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
1ipv4
2ipv6
.1.3.6.1.4.1.21317.1.3.2.3.5.1.3.1.2
trapReceiverIp
Outlet auto-ping destination IP address.
If the station does not support this OID, it returns value '0.0.0.0'.
If the station is not available, it returns '0.0.0.0'.
INET-ADDRESS-MIBInetAddressr/w
Textual Convention: INET-ADDRESS-MIBInetAddress OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.21317.1.3.2.3.5.1.3.1.3
.1.3.6.1.4.1.21317.1.3.2.3.50.1 · 1 row entry · 1 columns
Trap notification config table.
trapNotifConfigEntry entry .1.3.6.1.4.1.21317.1.3.2.3.50.1.1
Single entry containing trap notification config info.
Indexes
staId
Column Syntax OID
trapNotifConfigEn
Display or set whether this trap entry is enabled or not.
You should set the username/auth-password/priv-password first, when choosing snmpv3.
You should set the community string first, when choosing snmpv1/v2c.
If the …
Enumerationr/w
Enumerated Values:
-3000000staNotAvailable
1no
2yes
.1.3.6.1.4.1.21317.1.3.2.3.50.1.1.1
.1.3.6.1.4.1.21317.1.3.2.3.50.2 · 1 row entry · 5 columns
Trap notification alarm table.
trapNotifAlarmEntry entry .1.3.6.1.4.1.21317.1.3.2.3.50.2.1
Single entry containing trap notification alarm info.
Indexes
staId
Column Syntax OID
trapNotifAlarmBreakerStatus
Station breaker alarm status.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
-3000000staNotAvailable
0normal
1alarm
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.1
trapNotifAlarmCurrentStatus
Station current alarm status.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
-3000000staNotAvailable
0normal
1alarm
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.2
trapNotifAlarmVoltageStatus
Station voltage alarm status.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
-3000000staNotAvailable
0normal
1alarm
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.3
trapNotifAlarmPowerStatus
Station power alarm status.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
-3000000staNotAvailable
0normal
1alarm
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.4
trapNotifAlarmSensorStatus
Station sensor alarm status.
If the station is not available, it returns value -3000000.
Enumeration
Enumerated Values:
-3000000staNotAvailable
0normal
1alarm
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.5