ATEN-PE2-CFG Table View
Table-centric layout grouping table, row, and column objects.
Tables
38
Rows
38
Columns
162
staStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.1.2
·
1 row entry
·
10 columns
Station status table.
Single entry containing station status info.
Indexes
staId
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
staId
Station ID.
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.1 |
||||||||
|
staStatusFWVer
Station FW version.
If the station is not available, it returns 'station N/A'. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.2 |
||||||||
|
staStatusModelName
Station model name.
If the station is not available, it returns 'station N/A' |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.3 |
||||||||
|
staStatusSwitchable
Outlets of the station are switchable or not.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.4 |
||||||||
|
staStatusPerPortReading
Outlets of the station are per-port reading or not.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.5 |
||||||||
|
staStatusBankCount
Station bank count.
If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.6 |
||||||||
|
staStatusOutletCount
Station outlet count.
If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.7 |
||||||||
|
staStatusSensorCount
Station sensor count.
If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.8 |
||||||||
|
staStatusHasAutoPing
The station supports auto-ping or not.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.9 |
||||||||
|
staStatusInletCount
Station inlet count.
If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.1.2.1.10 |
staControlTable
table.1.3.6.1.4.1.21317.1.3.2.3.1.3
·
1 row entry
·
1 columns
Station control table.
Single entry containing station control info.
Indexes
staId
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
staControlReboot
Reboot the station.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.1.3.1.1 |
rackConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.1.4
·
1 row entry
·
3 columns
Rack config table.
Single entry containing rack config info.
Indexes
staId
| Column | Syntax | OID |
|---|---|---|
|
rackConfigName
Display or set station's rack name.
string length: 1~32 If the station is not available, it returns 'station N/A'. NOTE: Input string as /empty to set this object to NULL. |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.3.1.4.1.1 |
|
rackConfigRow
Display or set station's rack row number.
If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: 1-26 |
.1.3.6.1.4.1.21317.1.3.2.3.1.4.1.2 |
|
rackConfigColumn
Display or set station's rack column number.
If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: 1-26 |
.1.3.6.1.4.1.21317.1.3.2.3.1.4.1.3 |
devStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.1.1
·
1 row entry
·
4 columns
Device status table.
Single entry containing device status info.
Indexes
staId
| Column | Syntax | OID |
|---|---|---|
|
devStatusRatedCur
Device input Current value. unit:(0.1mA)
If the station does not support this OID, we show value 0. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.1.1.1 |
|
devStatusRatedVol
Device input Voltage value. unit:(0.1mV)
If the station does not support this OID, we show value 0. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.1.1.2 |
|
devStatusRatedPower
Device power Capacity value. unit:(0.1mVA)
If the station does not support this OID, we show value 0. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.1.1.3 |
|
devStatusWiredType
Device circuit wired type
Example: 1 for 1 phase, 2 for 3 phase wye, 3 for 3 phase delta If the station does not support this OID, we show value 0. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.1.1.4 |
devConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.1.2
·
1 row entry
·
10 columns
Device config table.
Single entry containing device config info.
Indexes
staId
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
devConfigDevName
The name of the device.
string length: 1~39 If the station is not available, it returns 'station N/A'. NOTE: Input string as /empty to set this object to NULL. |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.1 |
||||||||
|
devConfigPowerOnScheduleEn
Display or set whether power on schedule or not.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.2 |
||||||||
|
devConfigOutletsSequentialRebootEn
This function is used to enable or disable all outlet ports to sequential reboot.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.3 |
||||||||
|
devConfigMinCurThresh
Display or set device minimum electric current measurement threshold.
Example: range 0.0~32.0 represents 0~320. NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.4 |
||||||||
|
devConfigMaxCurThresh
Display or set device maximum electric current measurement threshold.
Example: range 0.0~32.0 represents 0~320 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station doe… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.5 |
||||||||
|
devConfigMinVolThresh
Display or set device minimum voltage measurement threshold.
Example: range 90.0~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -3000--3000range: 900-2600 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.6 |
||||||||
|
devConfigMaxVolThresh
Display or set device maximum voltage measurement threshold.
Example: range 90.0~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -3000--3000range: 900-2600 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.7 |
||||||||
|
devConfigMinPowerThresh
Display or set device minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not … |
Integer32r/w Constraints: range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.8 |
||||||||
|
devConfigMaxPowerThresh
Display or set device maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not … |
Integer32r/w Constraints: range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.9 |
||||||||
|
devConfigMaxPDThresh
Display or set device maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the sta… |
Integer32r/w Constraints: range: -3000--3000range: 0-999990 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.10 |
devControlTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.1.3
·
1 row entry
·
1 columns
Device control table.
Single entry containing device control info.
Indexes
staId
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
devControlOperation
This function is used for outlet control of device.
Set off(1) to turn off for outlet control of device. Set on(2) to turn on for all outlet control of device. Set reboot(3) to reboot for outlet control of device. Get t… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.1.3.1.1 |
devReadingTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.1.4
·
1 row entry
·
5 columns
Device reading table.
Single entry containing device reading info.
Indexes
staId
| Column | Syntax | OID |
|---|---|---|
|
devReadingCur
Device electric current value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.1 |
|
devReadingVol
Device voltage value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.2 |
|
devReadingPower
Device power value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.3 |
|
devReadingPD
Device power dissipation value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.4 |
|
devReadingPF
Device power factor value.
This value indicates that 100 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.4.1.5 |
popConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.1.5
·
1 row entry
·
4 columns
POP config table.
Single entry containing POP config info.
Indexes
staId
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
popConfigOutletModeEn
Display or set whether outlet POP mode is enabled or not.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.1.5.1.1 |
||||||||
|
popConfigLIFOModeEn
Display or set whether LIFO POP mode is enabled or not.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.1.5.1.2 |
||||||||
|
popConfigPriorityModeEn
Display or set whether priority POP mode is enabled or not.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.1.5.1.3 |
||||||||
|
popConfigPriorityList
Indicate Outlets' power OFF priorities under Priority POP mode.
Outlet Separator ',' Bank Separator '#' Assign each priority in each bank by Outlet index or zero (indicate N/A) with separators in ascendant order. e.g. f… |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.5.1.4 |
capConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.1.6
·
1 row entry
·
1 columns
CAP config table.
Single entry containing CAP config info.
Indexes
staId outletId
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
capConfigModeEn
Display or set whether CAP mode is enabled or not.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.1.6.1.1 |
capPriorityConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.1.7
·
1 row entry
·
1 columns
CAP priority config table.
Single entry containing CAP priority config info.
Indexes
staId outletId
| Column | Syntax | OID |
|---|---|---|
|
capPriorityConfigOutlet
Display or set the CAP Priority of outlet.
Priority 0 means this outlet does not support this OID. If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: 0-99 |
.1.3.6.1.4.1.21317.1.3.2.3.2.1.7.1.1 |
bankStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.2.1
·
1 row entry
·
5 columns
Bank status table.
Single entry containing bank status info.
Indexes
staId bankId
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
bankId
Bank ID.
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.1 |
||||||||||||||||
|
bankStatusRatedCur
The Bank Max Current value. unit: (0.1mA).
If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.2 |
||||||||||||||||
|
bankStatusAttachStatus
The bank attached status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.3 |
||||||||||||||||
|
bankStatusBreakerStatus
The breaker status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.4 |
||||||||||||||||
|
bankStatusPhaseLayout
Display the phase layout of bank.
Example: range 1 ~ 3 represents Line1-LineNeutral ~ Line3-lineNeutral. 4 ~ 6 represents Line1-Line2, Line2-Line3, Line3-Line1. If the station does not support this OID, it retur… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.2.1.1.5 |
bankConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.2.2
·
1 row entry
·
8 columns
Bank config table.
Single entry containing bank config info.
Indexes
staId bankId
| Column | Syntax | OID |
|---|---|---|
|
bankConfigName
Display or set the name of the bank.
When this model does not support the OID, we show n/a. string length: 0~15 If the station is not available, it returns 'station N/A'. NOTE: Input string as /empty to set this object … |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.1 |
|
bankConfigMinCurThresh
Display or set the bank minimum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station d… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.2 |
|
bankConfigMaxCurThresh
Display or set the bank maximum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station d… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.3 |
|
bankConfigMinVolThresh
Display or set the bank minimum voltage measurement threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does … |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-2600 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.4 |
|
bankConfigMaxVolThresh
Display or set the bank maximum voltage measurement threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does … |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-2600 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.5 |
|
bankConfigMinPowerThresh
Display or set the bank minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.6 |
|
bankConfigMaxPowerThresh
Display or set the bank maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.7 |
|
bankConfigMaxPDThresh
Display or set the bank maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the st… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-999990 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.2.1.8 |
bankControlTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.2.3
·
1 row entry
·
1 columns
Bank control table.
Single entry containing bank control info.
Indexes
staId bankId
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
bankControlOperation
This function is used for outlet control of bank.
Set off(1) to turn off for outlet control of bank. Set on(2) to turn on for all outlet control of bank. Set reboot(3) to reboot for outlet control of bank. Get this obje… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.2.3.1.1 |
bankReadingTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.2.4
·
1 row entry
·
5 columns
Bank reading table.
Single entry containing bank reading info.
Indexes
staId bankId
| Column | Syntax | OID |
|---|---|---|
|
bankReadingCur
Bank electric current value.
This value indicates that 10,000 times. If this measurement value is not available, it returns value -1000000. If the station does not support this OID, it returns value -2000000. If the sta… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.1 |
|
bankReadingVol
Bank voltage value.
This value indicates that 10,000 times. If this measurement value is not available, it returns value -1000000. If the station does not support this OID, it returns value -2000000. If the station is n… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.2 |
|
bankReadingPower
Bank power value.
This value indicates that 10,000 times. If this measurement value is not available, it returns value -1000000. If the station does not support this OID, it returns value -2000000. If the station is not… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.3 |
|
bankReadingPD
Bank power dissipation value.
This value indicates that 10,000 times. If this measurement value is not available, it returns value -1000000. If the station does not support this OID, it returns value -2000000. If the st… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.4 |
|
bankReadingPF
Bank power Factor value.
This value indicates that 100 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.2.4.1.5 |
outletStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.3.1
·
1 row entry
·
5 columns
Outlet status table.
Single entry containing outlet status info.
Indexes
staId outletId
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
outletId
Outlet ID.
|
Integer32 Constraints: range: 1-42 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.1 |
||||||||||||||||
|
outletStatusRatedCur
Outlet Max Current value. unit: (0.1mA).
If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.2 |
||||||||||||||||
|
outletStatusSwitchable
Outlet switchable.
If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.3 |
||||||||||||||||
|
outletStatusAutoPing
Outlet latest auto-ping result.
If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.4 |
||||||||||||||||
|
outletStatusPhaseLayout
Display the phase layout of outlet.
Example: range 1 ~ 3 represents Line1-LineNeutral ~ Line3-lineNeutral. 4 ~ 6 represents Line1-Line2, Line2-Line3, Line3-Line1. If the station does not support this OID, it retur… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.1.1.5 |
outletConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.3.2
·
1 row entry
·
21 columns
Outlet config table.
Single entry containing outlet config info.
Indexes
staId outletId
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
outletConfigName
Display or set the name of the outlet.
If the station does not support this OID, we show n/a. string length: 0~48 If the station is not available, it returns 'station N/A'. NOTE: Input string as /empty to set this ob… |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.1 |
||||||||||
|
outletConfigConfirmationEn
Display or set the confirmation of the outlet.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.2 |
||||||||||
|
outletConfigOnDelayTime
Display or set the ON delay time of the outlet.
When this model does not support the OID, we show value -1. If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: -1-999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.3 |
||||||||||
|
outletConfigOffDelayTime
Display or set the OFF delay time of the outlet.
When this model does not support the OID, we show value -1. If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: -1-999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.4 |
||||||||||
|
outletConfigShutdownMethod
Display or set the shutdown method of the outlet.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.5 |
||||||||||
|
outletConfigMAC
Display or set the MAC address of shutdown method.
The value is hex format with length 12. If the station does not support this OID, it return '00-00-00-00-00-00'. If the station is not available, it returns '00-00-00-0… |
SNMPv2-TCMacAddressr/w Textual Convention: SNMPv2-TCMacAddress OctetStringType Constraints: range: 6 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.6 |
||||||||||
|
outletConfigLocalAccessLock
Display or set whether the local access of the outlet is locked by remote or not.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.7 |
||||||||||
|
outletConfigMinCurThresh
Display or set the outlet minimum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.8 |
||||||||||
|
outletConfigMaxCurThresh
Display or set the outlet maximum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.9 |
||||||||||
|
outletConfigMinVolThresh
Display or set the outlet minimum voltage measurement threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station doe… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-2600 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.10 |
||||||||||
|
outletConfigMaxVolThresh
Display or set the outlet maximum voltage measurement threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station doe… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-2600 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.11 |
||||||||||
|
outletConfigMinPowerThresh
Display or set the outlet minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does n… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.12 |
||||||||||
|
outletConfigMaxPowerThresh
Display or set the outlet maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does n… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.13 |
||||||||||
|
outletConfigMaxPDThresh
Display or set the outlet maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the … |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-999990 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.14 |
||||||||||
|
outletConfigAutoPingContFailTimes
Display or set the outlet auto-ping continuously-failed time to reset outlet.
Example: range 0 ~ 5 Empty value: -3000. If the station does not support this OID, it returns value -2000000. If the station is not available… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-10 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.15 |
||||||||||
|
outletConfigAutoPingIntervalSec
Display or set the outlet auto-ping pinging interval in seconds.
Example: range 10 ~ 600 Empty value: -3000. If the station does not support this OID, it returns value -2000000. If the station is not available, it retur… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-60 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.16 |
||||||||||
|
outletConfigAutoPingRetryTimes
Display or set the outlet auto-ping max retry times.
Example: range 0 ~ 5 Empty value: -3000. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -30000… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-10 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.17 |
||||||||||
|
outletConfigAutoPingPowerUpDelaySec
Display or set the outlet auto-ping first-ping-delay in seconds after outlet switches on.
Example: range 10 ~ 600 Empty value: -3000. If the station does not support this OID, it returns value -2000000. If the station i… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-60 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.18 |
||||||||||
|
outletConfigAutoPingRemoteIPAddr
Outlet auto-ping destination IP address.
If the station does not support this OID, it returns value '0.0.0.0'. If the station is not available, it returns '0.0.0.0'. |
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.19 |
||||||||||
|
outletConfigAutoPingEnable
Display or set the outlet auto-ping enable state.
If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.20 |
||||||||||
|
outletConfigAutoPingEnableReboot
Display or set the outlet auto-ping reboot enable state.
If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.21 |
outletControlTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.3.3
·
1 row entry
·
1 columns
Outlet control table.
Single entry containing outlet control info.
Indexes
staId outletId
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
outletControlOperation
This function is used for the outlet control.
Set off(1) to turn off the outlet. Set on(2) to turn on the outlet. Set reboot(3) to reboot the outlet. pending(3), fault(5), noauth(6), not-suport(7), pop(8) can't be set. … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.3.1.1 |
outletReadingTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.3.4
·
1 row entry
·
5 columns
Outlet reading table.
Single entry containing outlet reading info.
Indexes
staId outletId
| Column | Syntax | OID |
|---|---|---|
|
outletReadingCur
Outlet electric current value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.1 |
|
outletReadingVol
Outlet voltage value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.2 |
|
outletReadingPower
Outlet power value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.3 |
|
outletReadingPD
Outlet power dissipation value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.4 |
|
outletReadingPF
Outlet Power Factor value.
This value indicates that 100 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.4.1.5 |
outletAutoPingIpTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.3.5
·
1 row entry
·
2 columns
Outlet auto-ping table.
Single entry containing outlet auto-ping ip info.
Indexes
staId outletId
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
outletConfigAutoPingRemoteIPType
Represents the type of the corresponding instance
of outletConfigAutoPingRemoteIP object. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.3.5.1.1 |
||||
|
outletConfigAutoPingRemoteIP
Outlet auto-ping destination IP address.
If the station does not support this OID, it returns value '0.0.0.0'. If the station is not available, it returns '0.0.0.0'. |
INET-ADDRESS-MIBInetAddressr/w Textual Convention: INET-ADDRESS-MIBInetAddress OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.21317.1.3.2.3.2.3.5.1.2 |
lineStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.4.1
·
1 row entry
·
2 columns
Line status table.
Single entry containing line status info.
Indexes
staId lineId
| Column | Syntax | OID |
|---|---|---|
|
lineId
Line ID.
|
Integer32 Constraints: range: 1-3 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.1.1.1 |
|
lineStatusRatedCur
The Max Line Current value. unit: (0.1mA)
If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.1.1.2 |
lineConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.4.2
·
1 row entry
·
6 columns
Line config table.
Single entry containing line config info.
Indexes
staId lineId
| Column | Syntax | OID |
|---|---|---|
|
lineConfigMinCurThresh
Display or set the line Minimum current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not s… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.1 |
|
lineConfigMaxCurThresh
Display or set the line Maximum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station d… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.2 |
|
lineConfigMinVolThresh
Display or set the line minimum voltage measurement threshold.
Example: range 90.0 ~380.0 represents 900~3800 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does … |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-3800 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.3 |
|
lineConfigMaxVolThresh
Display or set the line maximum voltage measurement threshold.
Example: range 90.0 ~380.0 represents 900~3800 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does … |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-3800 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.4 |
|
lineConfigMinPowerThresh
Display or set the line minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.5 |
|
lineConfigMaxPowerThresh
Display or set the line maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.2.1.6 |
lineReadingTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.4.3
·
1 row entry
·
3 columns
Line reading table.
Single entry containing line reading info.
Indexes
staId lineId
| Column | Syntax | OID |
|---|---|---|
|
lineReadingCur
Line current value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.3.1.1 |
|
lineReadingVol
Line voltage value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.3.1.2 |
|
lineReadingPower
Line power value.
This value indicates that 10,000 times. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.4.3.1.3 |
neutralStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.4.4
·
1 row entry
·
1 columns
Line reading table.
Single entry containing line reading info.
Indexes
staId
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
neutralStatusLeakageCur
Neutral leakage current status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.2.4.4.1.1 |
inletStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.5.1
·
1 row entry
·
2 columns
Inlet status table.
Single entry containing inlet status info.
Indexes
staId inletId
| Column | Syntax | OID |
|---|---|---|
|
inletId
Line ID.
|
Integer32 Constraints: range: 1-3 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.1.1.1 |
|
inletStatusRatedCur
The Inlet Max Current value. unit: (0.1mA).
If device is phase wye, then means L1 or L2 or L3 current. If device is phase delta, then means L1L2 or L2L3 or L3L1 current. If the station does not support this OID, it retu… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.1.1.2 |
inletConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.5.2
·
1 row entry
·
7 columns
Inlet config table.
Single entry containing inlet config info.
Indexes
staId inletId
| Column | Syntax | OID |
|---|---|---|
|
inletConfigMinCurThresh
Display or set the inlet Minimum current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not … |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.1 |
|
inletConfigMaxCurThresh
Display or set the inlet Maximum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station … |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.2 |
|
inletConfigMinVolThresh
Display or set the inlet minimum voltage measurement threshold.
Example: range 90.0 ~380.0 represents 900~3800 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-3800 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.3 |
|
inletConfigMaxVolThresh
Display or set the inlet maximum voltage measurement threshold.
Example: range 90.0 ~380.0 represents 900~3800 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 900-3800 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.4 |
|
inletConfigMinPowerThresh
Display or set the inlet minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does no… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.5 |
|
inletConfigMaxPowerThresh
Display or set the inlet maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does no… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-99999 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.6 |
|
inletConfigMaxPDThresh
Display or set the inlet maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the s… |
Integer32r/w Constraints: range: -2000000--2000000range: -3000--3000range: 0-999990 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.2.1.7 |
inletReadingTable
table.1.3.6.1.4.1.21317.1.3.2.3.2.5.3
·
1 row entry
·
4 columns
Inlet reading table.
Single entry containing inlet reading info.
Indexes
staId inletId
| Column | Syntax | OID |
|---|---|---|
|
inletReadingCur
Inlet current value.
If device is phase wye, then means L1 or L2 or L3 current. If device is phase delta, then means L1L2 or L2L3 or L3L1 current. This value indicates that 10,000 times. If the station does not support … |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.3.1.1 |
|
inletReadingVol
Inlet voltage value.
If device is phase wye, then means L1 or L2 or L3 voltage. If device is phase delta, then means L1L2 or L2L3 or L3L1 voltage. This value indicates that 10,000 times. If the station does not support … |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.3.1.2 |
|
inletReadingPower
Inlet power value.
If device is phase wye, then means L1 or L2 or L3 power. If device is phase delta, then means L1L2 or L2L3 or L3L1 power. This value indicates that 10,000 times. If the station does not support this O… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.3.1.3 |
|
inletReadingPD
Inlet power value.
If device is phase wye, then means L1 or L2 or L3 power dissipation. If device is phase delta, then means L1L2 or L2L3 or L3L1 power dissipation. This value indicates that 10,000 times. If the station… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.2.5.3.1.4 |
sensorConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.3.1.3
·
1 row entry
·
8 columns
Sensor config table. Use port/addr as indexes to access sensor configurations.
Single entry containing sensor config info.
Indexes
staId sensorPort sensorAddr
| Column | Syntax | OID |
|---|---|---|
|
sensorPort
Sensor Port Number.
|
Integer32 Constraints: range: 1-4 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.1 |
|
sensorAddr
Sensor Address.
|
Integer32 Constraints: range: 1-31 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.2 |
|
sensorConfigMinTempThresh
Display or set sensor minimum temperature measurement threshold.
Example: range -20.0 ~ 60.0 represents -200~600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station doe… |
Integer32r/w Constraints: range: -3000--3000range: -200-600 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.3 |
|
sensorConfigMaxTempThresh
Display or set sensor maximum temperature measurement threshold.
Example: range -20.0 ~ 60.0 represents -200~600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station doe… |
Integer32r/w Constraints: range: -3000--3000range: -200-600 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.4 |
|
sensorConfigMinHumThresh
Display or set sensor minimum humidity measurement threshold.
Example: range 10.0 ~ 95.0 represents 100~950 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -3000--3000range: 100-950 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.5 |
|
sensorConfigMaxHumThresh
Display or set sensor maximum humidity measurement threshold.
Example: range 10.0 ~ 95.0 represents 100~950 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station does not… |
Integer32r/w Constraints: range: -3000--3000range: 100-950 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.6 |
|
sensorConfigMinPressThresh
Display or set sensor minimum pressure measurement threshold.
Example: range -250.0 ~ 250.0 represents -2500 ~ 2500 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station … |
Integer32r/w Constraints: range: -3000--3000range: -2500-2500 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.7 |
|
sensorConfigMaxPressThresh
Display or set sensor maximum pressure measurement threshold.
Example: range -250.0 ~ 250.0 represents -2500 ~ 2500 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the station … |
Integer32r/w Constraints: range: -3000--3000range: -2500-2500 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.3.1.8 |
sensorReadingTable
table.1.3.6.1.4.1.21317.1.3.2.3.3.1.4
·
1 row entry
·
3 columns
Sensor reading table. Use port/addr as indexes to access sensor readings.
Single entry containing sensor reading info.
Indexes
staId sensorPort sensorAddr
| Column | Syntax | OID |
|---|---|---|
|
sensorReadingTemp
Sensor's Temperature value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the station does not support this OID, it returns value -2000000. If the stati… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.4.1.1 |
|
sensorReadingHum
Sensor's Humidity value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the station does not support this OID, it returns value -2000000. If the station … |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.4.1.2 |
|
sensorReadingPress
Sensor's Pressure value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the station does not support this OID, it returns value -2000000. If the station … |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.3.3.1.4.1.3 |
dryContactStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.3.2.1
·
1 row entry
·
2 columns
Dry contact status table.
Single entry containing dry contact status info.
Indexes
staId dryContactId
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
dryContactId
Dry contact ID.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.21317.1.3.2.3.3.2.1.1.1 |
||||||||||
|
dryContactStatus
Display dry contact status.
close(0) represents door close. open(1) represents door open. not-attached(2) represents door sensor don't attach to device. If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.3.2.1.1.2 |
dryContactConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.3.2.2
·
1 row entry
·
1 columns
Dry contact config table.
Single entry containing dry contact config info.
Indexes
staId dryContactId
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
dryContactConfigType
Display or set dry contact type.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.3.2.2.1.1 |
netStatusTable
table.1.3.6.1.4.1.21317.1.3.2.3.4.1
·
1 row entry
·
1 columns
Net status table.
Single entry containing net status info.
Indexes
staId
| Column | Syntax | OID |
|---|---|---|
|
netStatusMAC
Station MAC address.
The value is hex format with length 12. If the station does not support this OID, it return '00-00-00-00-00-00'. If the station is not available, it returns '00-00-00-00-00-00'. |
SNMPv2-TCMacAddress Textual Convention: SNMPv2-TCMacAddress OctetStringType Constraints: range: 6 |
.1.3.6.1.4.1.21317.1.3.2.3.4.1.1.1 |
httpConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.4.2
·
1 row entry
·
3 columns
HTTP config table.
Single entry containing HTTP config info.
Indexes
staId
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
httpConfigHttpPort
Display or set the HTTP port of the station.
If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.21317.1.3.2.3.4.2.1.1 |
||||||
|
httpConfigHttpsPort
Display or set the HTTPs port of the station.
If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.21317.1.3.2.3.4.2.1.2 |
||||||
|
httpConfigHttpsOnlyEn
Display or set whether to use HTTPS only or HTTP/HTTPS for the web page.
If the station is not available, it returns value -3000000. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.4.2.1.3 |
netConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.4.3
·
1 row entry
·
8 columns
Net config table.
Single entry containing net config info.
Indexes
staId netCablePort
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
netCablePort
Network Port Number.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.1 |
||||
|
netConfigAutoIP
Display or set IPv4 address automatically or not
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.2 |
||||
|
netConfigIPv4
Display or set fixed IPv4 address
|
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.3 |
||||
|
netConfigSubMask
Display or set subnet mask address
|
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.4 |
||||
|
netConfigGateway
Display or set gateway address
|
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.5 |
||||
|
netConfigAutoDNS
Display or set DNS address automatically or not
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.6 |
||||
|
netConfigPreferDNSIPv4
Display or set prefer DNS address
|
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.7 |
||||
|
netConfigAlterDNSIPv4
Display or set alternate DNS address
|
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.3.4.3.1.8 |
trapConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.5.1.1
·
1 row entry
·
2 columns
Trap config table.
Single entry containing trap config info.
Indexes
staId
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
trapConfigEn
Display or set whether this trap entry is enabled or not.
You should set the username/auth-password/priv-password first, when choosing snmpv3. You should set the community string first, when choosing snmpv1/v2c. If the … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.5.1.1.1.1 |
||||||||
|
trapConfigVer
Display or set SNMP trap version for sending trap.
You should set the username/auth-password/priv-password first, when choosing snmpv3. You should set the community string first, when choosing snmpv1/v2c. If the station… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.5.1.1.1.2 |
trapReceiverConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.5.1.2
·
1 row entry
·
7 columns
SNMP agent trap setup table. If users want to use trap, they must set enable trap, IP and community first.
Single entry containing trap receiver config info.
Indexes
staId trapReceiverConfigIdx
| Column | Syntax | OID |
|---|---|---|
|
trapReceiverConfigIdx
Index of trap receiver.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.1 |
|
trapReceiverConfigIp
Trap receiver IP address.
If the station does not support this OID, it returns value '0.0.0.0'. If the station is not available, it returns '0.0.0.0'. |
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.2 |
|
trapReceiverConfigPort
NMS trap port to be used by agent to send trap.
If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.3 |
|
trapReceiverConfigCommunity
If use SNMPv1/v2c to receive trap should set this community string.
MAX string length: 20 If the station does not support this OID, it returns value 'not-support'. If the station is not available, it returns 'station N/… |
OctetStringr/w Constraints: range: 0-20 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.4 |
|
trapReceiverConfigUsername
If use SNMPv3 to receive trap should set this username string.
MAX string length: 20. If the station does not support this OID, it returns value 'not-support'. If the station is not available, it returns 'station N/A'. … |
OctetStringr/w Constraints: range: 0-20 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.5 |
|
trapReceiverConfigAuthPwd
If use SNMPv3 to receive trap should set this auth password string.
MAX string length: 20 If the station does not support this OID, it returns value 'not-support'. If the station is not available, it returns 'station N/… |
OctetStringr/w Constraints: range: 8-20 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.6 |
|
trapReceiverConfigPrivacyPwd
If use SNMPv3 to receive trap should set this privacy password string.
MAX string length: 20 If the station does not support this OID, it returns value 'not-support'. If the station is not available, it returns 'station… |
OctetStringr/w Constraints: range: 8-20 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.2.1.7 |
trapReceiverIpTable
table.1.3.6.1.4.1.21317.1.3.2.3.5.1.3
·
1 row entry
·
3 columns
Trap Receiver Ip table.
Single entry containing trap receiver ip info.
Indexes
staId trapReceiverIpIdx
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
trapReceiverIpIdx
Index of trap receiver.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.3.1.1 |
||||
|
trapReceiverIpType
Represents the type of the corresponding instance
of trapReceiverIp object. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.5.1.3.1.2 |
||||
|
trapReceiverIp
Outlet auto-ping destination IP address.
If the station does not support this OID, it returns value '0.0.0.0'. If the station is not available, it returns '0.0.0.0'. |
INET-ADDRESS-MIBInetAddressr/w Textual Convention: INET-ADDRESS-MIBInetAddress OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.21317.1.3.2.3.5.1.3.1.3 |
trapNotifConfigTable
table.1.3.6.1.4.1.21317.1.3.2.3.50.1
·
1 row entry
·
1 columns
Trap notification config table.
Single entry containing trap notification config info.
Indexes
staId
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
trapNotifConfigEn
Display or set whether this trap entry is enabled or not.
You should set the username/auth-password/priv-password first, when choosing snmpv3. You should set the community string first, when choosing snmpv1/v2c. If the … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.50.1.1.1 |
trapNotifAlarmTable
table.1.3.6.1.4.1.21317.1.3.2.3.50.2
·
1 row entry
·
5 columns
Trap notification alarm table.
Single entry containing trap notification alarm info.
Indexes
staId
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
trapNotifAlarmBreakerStatus
Station breaker alarm status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.1 |
||||||
|
trapNotifAlarmCurrentStatus
Station current alarm status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.2 |
||||||
|
trapNotifAlarmVoltageStatus
Station voltage alarm status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.3 |
||||||
|
trapNotifAlarmPowerStatus
Station power alarm status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.4 |
||||||
|
trapNotifAlarmSensorStatus
Station sensor alarm status.
If the station is not available, it returns value -3000000. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.3.50.2.1.5 |