devConfigDevName
ATEN-PE2-CFG ·
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.1
Object
The name of the device. string length: 1~39 If the station is not available, it returns 'station N/A'. NOTE: Input string as /empty to set this object to NULL.
Context
- MIB
- ATEN-PE2-CFG
- OID
.1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.1- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- devConfigEntry
- Table
- devConfigTable
- Siblings
- 9
Syntax
RFC1213-MIBDisplayString
- Source
- RFC1213-MIBDisplayString
- Base type
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| devConfigMaxPDThresh Display or set device maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990
NOTICE: Minimum threshold should be smaller than maximum t… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.10 |
| devConfigPowerOnScheduleEn Display or set whether power on schedule or not.
If the station is not available, it returns value -3000000. | column | Enumeration | .1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.2 |
| devConfigOutletsSequentialRebootEn This function is used to enable or disable all outlet ports to sequential reboot.
If the station is not available, it returns value -3000000. | column | Enumeration | .1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.3 |
| devConfigMinCurThresh Display or set device minimum electric current measurement threshold.
Example: range 0.0~32.0 represents 0~320.
NOTICE: Minimum threshold should be smaller than maximum threshold.… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.4 |
| devConfigMaxCurThresh Display or set device maximum electric current measurement threshold.
Example: range 0.0~32.0 represents 0~320
NOTICE: Minimum threshold should be smaller than maximum threshold… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.5 |
| devConfigMinVolThresh Display or set device minimum voltage measurement threshold.
Example: range 90.0~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Emp… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.6 |
| devConfigMaxVolThresh Display or set device maximum voltage measurement threshold.
Example: range 90.0~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold.
Emp… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.7 |
| devConfigMinPowerThresh Display or set device minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empt… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.8 |
| devConfigMaxPowerThresh Display or set device maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
Empt… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.1.2.1.9 |