outletConfigAutoPingIntervalSec
ATEN-PE2-CFG ·
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.16
Object
column
r/w
Integer32
Display or set the outlet auto-ping pinging interval in seconds. Example: range 10 ~ 600 Empty value: -3000. If the station does not support this OID, it returns value -2000000. If the station is not available, it returns value -3000000.
Context
- MIB
- ATEN-PE2-CFG
- OID
.1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.16- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- outletConfigEntry
- Table
- outletConfigTable
- Siblings
- 20
Syntax
Integer32
Values & Constraints
Object Constraints
range: -2000000--2000000
range: -3000--3000
range: 0-60
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| outletConfigName Display or set the name of the outlet.
If the station does not support this OID, we show n/a.
string length: 0~48
If the station is not available, it returns 'station N/A'.
NOT… | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.1 |
| outletConfigMinVolThresh Display or set the outlet minimum voltage measurement threshold.
Example: range 90.0 ~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.10 |
| outletConfigMaxVolThresh Display or set the outlet maximum voltage measurement threshold.
Example: range 90.0 ~260.0 represents 900~2600
NOTICE: Minimum threshold should be smaller than maximum threshold… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.11 |
| outletConfigMinPowerThresh Display or set the outlet minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
E… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.12 |
| outletConfigMaxPowerThresh Display or set the outlet maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999
NOTICE: Minimum threshold should be smaller than maximum threshold.
E… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.13 |
| outletConfigMaxPDThresh Display or set the outlet maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990
NOTICE: Minimum threshold should be smaller than maximu… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.14 |
| outletConfigAutoPingContFailTimes Display or set the outlet auto-ping continuously-failed time to reset outlet.
Example: range 0 ~ 5
Empty value: -3000.
If the station does not support this OID, it returns value -… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.15 |
| outletConfigAutoPingRetryTimes Display or set the outlet auto-ping max retry times.
Example: range 0 ~ 5
Empty value: -3000.
If the station does not support this OID, it returns value -2000000.
If the station i… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.17 |
| outletConfigAutoPingPowerUpDelaySec Display or set the outlet auto-ping first-ping-delay in seconds after outlet switches on.
Example: range 10 ~ 600
Empty value: -3000.
If the station does not support this OID, it … | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.18 |
| outletConfigAutoPingRemoteIPAddr Outlet auto-ping destination IP address.
If the station does not support this OID, it returns value '0.0.0.0'.
If the station is not available, it returns '0.0.0.0'. | column | RFC1155-SMIIpAddress | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.19 |
| outletConfigConfirmationEn Display or set the confirmation of the outlet.
If the station is not available, it returns value -3000000. | column | Enumeration | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.2 |
| outletConfigAutoPingEnable Display or set the outlet auto-ping enable state.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -3000000. | column | Enumeration | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.20 |
| outletConfigAutoPingEnableReboot Display or set the outlet auto-ping reboot enable state.
If the station does not support this OID, it returns value -2000000.
If the station is not available, it returns value -30… | column | Enumeration | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.21 |
| outletConfigOnDelayTime Display or set the ON delay time of the outlet.
When this model does not support the OID, we show value -1.
If the station is not available, it returns value -3000000. | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.3 |
| outletConfigOffDelayTime Display or set the OFF delay time of the outlet.
When this model does not support the OID, we show value -1.
If the station is not available, it returns value -3000000. | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.4 |
| outletConfigShutdownMethod Display or set the shutdown method of the outlet.
If the station is not available, it returns value -3000000. | column | Enumeration | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.5 |
| outletConfigMAC Display or set the MAC address of shutdown method.
The value is hex format with length 12.
If the station does not support this OID, it return '00-00-00-00-00-00'.
If the station … | column | SNMPv2-TCMacAddress | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.6 |
| outletConfigLocalAccessLock Display or set whether the local access of the outlet is locked by remote or not.
If the station is not available, it returns value -3000000. | column | Enumeration | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.7 |
| outletConfigMinCurThresh Display or set the outlet minimum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160
NOTICE: Minimum threshold should be smaller than maximum thres… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.8 |
| outletConfigMaxCurThresh Display or set the outlet maximum electric current measurement threshold.
Example: range 0.0 ~16.0 represents 0~160
NOTICE: Minimum threshold should be smaller than maximum thres… | column | Integer32 | .1.3.6.1.4.1.21317.1.3.2.3.2.3.2.1.9 |