NBS-SFF-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
111
.1.3.6.1.4.1.629.204.1.1.1 · 1 row entry · 27 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsSffMsaTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-SFF-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-SFF-MIB::nbsSffMsaTable'
Operations, Administration, and Management information
nbsSffMsaEntry row .1.3.6.1.4.1.629.204.1.1.1.1
Represents a SFF MSA details of a port.
Column Syntax OID
ifIndex from MIB2
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.629.204.1.1.1.1.1
The MSA Identifier as reported in the MSA memory map, +1.

Some of these MSA Identifiers are also represented in
nbsCmmcPortType from the NBS-CMMC-MIB:

nbsSffMsaIdentifier nbsCmmcPortType
-…
Enumeration
Enumerated Values:
1unknown
2gbic
3moduleSolderedToBoard
4sfpTransceiver
5threeHundredPinXBI
6xenpak
7xfp
8xff
9xfpe
10xpak
11x2
12dwdm
13qsfp
14qsfpPlus
15cfp
16cxp
130mrvCxp
.1.3.6.1.4.1.629.204.1.1.1.1.2
The field should be set to 04h for all SFP modules indicating
serial ID module definition.

Not supported value: 0
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.1.1.1.3
The Optical Connector as reported in the MSA memory map, +1.

Here is the list of values:
1 - unknown
2 - SC
3 - Fiber Channel Style 1 copper connector
4 - Fiber Channel Style 2 copper connector
5 - BNC/TN…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.1.1.1.4
The following bit significant indicators define the
electronic or optical interfaces that are supported by the
SFP transceiver. At least one bit shall be set in this field.
For Fibre Channel SFPs, the Fibre Channel spee…
OctetString
Constraints:
range: 8-11
.1.3.6.1.4.1.629.204.1.1.1.1.5
The encoding value indicates the serial encoding mechanism
that is the nominal design target of the particular
transceiver. The value shall be contained in the serial data.
For XFPs this object must return notSupported,…
Enumeration
Enumerated Values:
1notSupported
2lineCode8To10
3lineCode4To5
4nrz
5manchester
6sonetScrambled
7unspecified
.1.3.6.1.4.1.629.204.1.1.1.1.6
The nominal bit rate (BR, nominal) is specified in units of
100 Megabits per second, rounded off to the nearest 100
Megabits per second. The bit rate includes those bits
necessary to encode and delimit the signal as wel…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.1.1.1.7
This value specifies the link length that is supported by the
transceiver while operating in compliance with the applicable
standards using single mode fiber. The value is in units of
kilometers. A value of 255 means th…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.1.1.1.8
This value specifies the link length that is supported by the
transceiver while operating in compliance with the applicable
standards using single mode fiber. The value is in units of
100 meters. A value of 255 means th…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.1.1.1.9
This value specifies link length that is supported by the
transceiver while operating in compliance with applicable
standards using 50 micron multimode OM2 [500MHz*km at 850nm,]
fiber. The value is in units of 10 meters…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.1.1.1.10
This value specifies link length that is supported by the
transceiver while operating in compliance with applicable
standards using 62.5 micron multimode OM1 [200 MHz*km at
850nm, 500 MHz*km at 1310nm] fiber. The value …
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.1.1.1.11
This value specifies the minimum link length that is supported
by the transceiver while operating in compliance with the
applicable standards using copper cable. The value is in units
of 1 meter. A value of 255 means th…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.1.1.1.12
The vendor name is a 16 character field that contains ASCII
characters, The vendor name shall be the full name of the
corporation, a commonly accepted abbreviation of the name of
the corporation, the SCSI company code f…
OctetString
Constraints:
range: 0-16
.1.3.6.1.4.1.629.204.1.1.1.1.13
The vendor organizationally unique identifier field (vendor
OUI) is a 3-byte field that contains the IEEE Company
Identifier for the vendor. A value of all zero in the 3-byte
field indicates that the Vendor OUI is unspe…
OctetString
Constraints:
range: 3-3
.1.3.6.1.4.1.629.204.1.1.1.1.14
The vendor part number (vendor PN) is a 16-byte field that
contains ASCII characters, left-aligned, defining the vendor
part number or product name.

Unlike the MSA standard, agent returns size 0 string if…
OctetString
Constraints:
range: 0-16
.1.3.6.1.4.1.629.204.1.1.1.1.15
The vendor revision number (vendor rev) is a 4-byte field that
contains ASCII characters, defining the vendor's product
revision number.

Unlike the MSA standard, agent returns size 0 string if the
part nu…
OctetString
Constraints:
range: 0-4
.1.3.6.1.4.1.629.204.1.1.1.1.16
The check code is a one byte code that can be used to verify
that the first 64 (0-63) bytes of serial information in the
SFP transceiver is valid.Returns yes if checksum matches, no
if checksum doesn't match. For XFPs, …
Enumeration
Enumerated Values:
1no
2yes
.1.3.6.1.4.1.629.204.1.1.1.1.17
Byte 65 Bit 1. Signal as defined in the specification
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.1.1.1.18
Byte 65 Bit 2. Signal as defined in the specification
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.1.1.1.19
Byte 65 Bit 3.TX_FAULT signal implemented. Reset definition
in Section III and Laser Fault condition, Generated by laser
safety system.
Enumeration
Enumerated Values:
1off
2on
.1.3.6.1.4.1.629.204.1.1.1.1.20
Byte 65 Bit 4.TX_DISABLE is implemented and disables the
serial output.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.1.1.1.21
Byte 65 Bit 5.If this bit is set then active control of the
rate select pin is required to change rates. If bit is not
set, no control of pin is required. In all cases, compliance
with multiple rate standards should be …
Enumeration
Enumerated Values:
1no
2yes
.1.3.6.1.4.1.629.204.1.1.1.1.22
The upper bit rate limit at which the SFP transceiver will
still meet its specifications (BR, max) is specified in units
of 1% above the nominal bit rate. A value of zero indicates
that this field is not specified.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.1.1.1.23
The lower bit rate limit at which the SFP transceiver will
still meet its specifications (BR, min) is specified in units
of 1% below the nominal bit rate. A value of zero indicates
that this field is not specified.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.1.1.1.24
The vendor serial number (vendor SN) is a 16 character field
that contains ASCII characters, left-aligned and padded on
the right with ASCII spaces (20h), defining the vendor's
serial number for the SFP transceiver. A v…
OctetString
Constraints:
range: 0-16
.1.3.6.1.4.1.629.204.1.1.1.1.25
The date code is an 8-byte field that contains the vendor's
date code in ASCII characters. The date code is mandatory.
OctetString
Constraints:
range: 6-8
.1.3.6.1.4.1.629.204.1.1.1.1.26
The check code is a one byte code that can be used to verify
that the first 32 bytes of extended serial information in the
SFP transceiver is valid. The check code shall be the low
order 8 bits of the sum of the content…
Enumeration
Enumerated Values:
1no
2yes
.1.3.6.1.4.1.629.204.1.1.1.1.27
.1.3.6.1.4.1.629.204.1.2.1 · 1 row entry · 19 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsSffWdmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-SFF-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-SFF-MIB::nbsSffWdmTable'
Operations, Administration, and Management information
nbsSffWdmEntry row .1.3.6.1.4.1.629.204.1.2.1.1
Represents WDM properties of a port.
Column Syntax OID
Extended identifier of class of Power.
Enumeration
Enumerated Values:
1under1W
2oneToOneAndHalfW
3overOneAndHalfW
4reserved
.1.3.6.1.4.1.629.204.1.2.1.1.1
Extended identifier of class of Temperature.
class0 - Temperature in [-5, 70C]
class1 - Temperature in [-40, 85C]
class2 - reserved
class3 - defined by MIB objects nbsSffDwdmMaxCaseTemperature &
nbsSffDwdmMinCa…
Enumeration
Enumerated Values:
1class0
2class1
3class2
4class3
.1.3.6.1.4.1.629.204.1.2.1.1.2
Extended identifier of class of WDM.
1 - No WDM
2 - CWDM
3 - DWDM
4 - Reserved
Enumeration
Enumerated Values:
1noWdm
2cwdm
3dwdm
4reserved
.1.3.6.1.4.1.629.204.1.2.1.1.3
This value specifies the link length in kilometers that is
supported by the transceiver while operating in compliance
with the applicable standards using single mode fiber.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.2.1.1.4
This field defines the maximum operating case temperature in
Celsius. For WDMs, this value is in byte 15 in A0h, For XFPs,
this value is in byte 190.
Integer32
Constraints:
range: -2147483647-2147483647
.1.3.6.1.4.1.629.204.1.2.1.1.5
This field defines the minimum operating case temperature
in Celsius.
Integer32
Constraints:
range: -2147483647-2147483647
.1.3.6.1.4.1.629.204.1.2.1.1.6
This field defines the maximum supply current, in milli Amps,
which the module will consume under worst case conditions.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.2.1.1.7
This specifies the tuning range from 1 to 63, where 1
indicates this module is not tunable by user commands.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.2.1.1.8
This field identifies the densest channel spacing the module
is compatible with and the number of channels over which the
module may be tuned by user command.
Enumeration
Enumerated Values:
1notTunable
2ghz50
3ghz100
4ghz200
.1.3.6.1.4.1.629.204.1.2.1.1.9
DWDM Variable Decission Threshold.
Enumeration
Enumerated Values:
1notSupported
2supported
.1.3.6.1.4.1.629.204.1.2.1.1.10
DWDM Wavelength monitor type in A2 byte.
Enumeration
Enumerated Values:
1wavelength
2laserTemperature
.1.3.6.1.4.1.629.204.1.2.1.1.11
DWDM Extended Transmit Power Type.
Enumeration
Enumerated Values:
1pwrDefault
2pwrExtended
.1.3.6.1.4.1.629.204.1.2.1.1.12
DWDM Variable Optical Atttenuator.
Enumeration
Enumerated Values:
1notImplemented
2implemented
.1.3.6.1.4.1.629.204.1.2.1.1.13
DWDM Pilot Tone Functionality.
Enumeration
Enumerated Values:
1pilotToneNone
2pilotToneDetection
3pilotToneInjection
4pilotToneInjectionDetection
5pilotToneEnhanced
.1.3.6.1.4.1.629.204.1.2.1.1.14
DWDM Optional Interrupt Pin.
Enumeration
Enumerated Values:
1notSupported
2supported
.1.3.6.1.4.1.629.204.1.2.1.1.15
Nominal transmitter output wavelength.

For SFPs, per Specification for DWDM SFP Transceiver,
section 2.2.1, The laser wavelength
is equal to the 16 bit integer value in nm (16 bit value with
byte 60 as hi…
OctetString
Constraints:
range: 0-150
.1.3.6.1.4.1.629.204.1.2.1.1.16
Nominal transmitter frequency, in MHz
NBS-MIBNbsTcMHz
Type Constraints:
range: 1..4294967295
.1.3.6.1.4.1.629.204.1.2.1.1.17
ITU Channel Band
NBS-CMMCENUM-MIBNbsCmmcChannelBand
Type Values:
0notSupported
1cBand
2hBand
3lBand
4qBand
.1.3.6.1.4.1.629.204.1.2.1.1.18
ITU Channel Number
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.2.1.1.19
.1.3.6.1.4.1.629.204.1.3.1 · 1 row entry · 63 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsSffDiagsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-SFF-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-SFF-MIB::nbsSffDiagsTable'
Operations, Administration, and Management information
nbsSffDiagsEntry row .1.3.6.1.4.1.629.204.1.3.1.1
Represents Digital Diagnostics of a port.
Column Syntax OID
The rate identifier byte refers to several (optional) industry
standard definitions of Rate_Select or Application_Select
control behaviors, intended to manage transceiver optimization
for multiple operating rates.
Enumeration
Enumerated Values:
1notSupported
2rate421G
3rate842GRx
4rate842GRxTx
5rate842GTx
.1.3.6.1.4.1.629.204.1.3.1.1.1
This value specifies link length that is supported by the
transceiver while operating in compliance with applicable
standards using 50 micron multimode OM3 [2000 MHz*km] fiber.
The value is in units of 10 meters. A valu…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.2
Nominal transmitter output wavelength at room temperature. 16
bit value with byte 60 as high order byte and byte 61 as low
order byte. The laser wavelength is equal to the the 16 bit
integer value in nm. This field allo…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.3
Byte 64, bit 0. Value of 1 identifies a conventional
limiting (or unspecified) receiver output. Value of 2
identifies a linear receiver output.
Enumeration
Enumerated Values:
1no
2yes
.1.3.6.1.4.1.629.204.1.3.1.1.4
Byte 64, bit 1. Value 1 identifies Power Level 1 (or
unspecified) requirements. Value 2 identifies a Power
Level2 requirements.
Enumeration
Enumerated Values:
1level1
2level2
.1.3.6.1.4.1.629.204.1.3.1.1.5
Byte 64, bit 2. Value 1 identifies a conventional
uncooled (or unspecified) laser implementation. Value 2
identifies a cooled laser transmitter implementation.
Enumeration
Enumerated Values:
1uncooled
2cooled
.1.3.6.1.4.1.629.204.1.3.1.1.6
Byte 92, bit 2 indicates whether or not it is necessary for
the host to perform an address change sequence before
accessing information at 2-wire serial address A2h. If this
bit is not set, the host may simply read from…
Enumeration
Enumerated Values:
1no
2yes
.1.3.6.1.4.1.629.204.1.3.1.1.7
Byte 92, bit 3 indicates whether the received power
measurement represents average input optical power or OMA.
If the bit is set, average power is monitored. If it is not,
OMA is monitored. For XFPs, the address locatio…
Enumeration
Enumerated Values:
1oma
2averagePower
.1.3.6.1.4.1.629.204.1.3.1.1.8
Byte 92, bit 4 Externally Calibrated
Two calibration options are possible if bit 6 has been set
indicating that digital diagnostic monitoring has been
implemented. If bit 4 is set, the reported values are A/D
counts whi…
Enumeration
Enumerated Values:
1no
2yes
.1.3.6.1.4.1.629.204.1.3.1.1.9
Byte 92, bit 5 Internally Calibrated.
Two calibration options are possible if bit 6 has been set
indicating that digital diagnostic monitoring has been
implemented. If bit 5, Internally calibrated is set, the
transceive…
Enumeration
Enumerated Values:
1no
2yes
.1.3.6.1.4.1.629.204.1.3.1.1.10
Byte 92, bit 6. If this bit is set indicating that digital
diagnostic monitoring has been implemented, received power
monitoring, transmitted power monitoring, bias current
monitoring, supply voltage monitoring and temp…
Enumeration
Enumerated Values:
1no
2yes
.1.3.6.1.4.1.629.204.1.3.1.1.11
Byte 93 bit 1. Optional Rate Select control implemented per
SFF-8431. Sets to 1 if not implemented, 2 if implemented.
Enumeration
Enumerated Values:
1notImplemented
2implemented
.1.3.6.1.4.1.629.204.1.3.1.1.12
Based on byte 93 bit 2. Optional Application Select control
implemented per SFF-8079. Sets to 1 if not
implemented, 2 if implemented.
Enumeration
Enumerated Values:
1notImplemented
2implemented
.1.3.6.1.4.1.629.204.1.3.1.1.13
Based on byte 93 bit 3. Optional soft RATE_SELECT control and
monitoring implemented. Sets to 1 if not implemented,
2 if implemented.
Enumeration
Enumerated Values:
1notImplemented
2implemented
.1.3.6.1.4.1.629.204.1.3.1.1.14
Based on byte 93 bit 4. Optional soft RX_LOS monitoring
implemented. Sets to 1 if not implemented, 2 if implemented.
Enumeration
Enumerated Values:
1notImplemented
2implemented
.1.3.6.1.4.1.629.204.1.3.1.1.15
Based on byte 93 bit 5. Optional soft TX_FAULT monitoring
implemented. Sets to 1 if not implemented, 2 if implemented.
Enumeration
Enumerated Values:
1notImplemented
2implemented
.1.3.6.1.4.1.629.204.1.3.1.1.16
Based on byte 93 bit 6. Optional soft TX_DISABLE control and
monitoring implemented.Sets to 1 if not implemented, 2 if
implemented.
Enumeration
Enumerated Values:
1notImplemented
2implemented
.1.3.6.1.4.1.629.204.1.3.1.1.17
Based on byte 93 bit 7. Optional Alarm/warning flags
implemented for all monitored quantities.Sets to 1 if
not implemented, 2 if implemented. See Table 3.18
Enumeration
Enumerated Values:
1notImplemented
2implemented
.1.3.6.1.4.1.629.204.1.3.1.1.18
Byte 94 contains an unsigned integer that indicates which
feature set(s) are implemented in the transceiver.
Enumeration
Enumerated Values:
1notSupported
2rev9dot3of8472
3rev9dot5of8472
4rev10dot2of8472
5rev10dot4of8472
6rev11dot0of8472
7rev11dot3of8472
8rev11dot4of8472
9rev12dot0of8472
256unallocated
.1.3.6.1.4.1.629.204.1.3.1.1.19
Module temperature in centigradese.
Integer32
Constraints:
range: -2147483647-2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.20
Predefined temperature for low alarm threshold in
Centigrades.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.21
Predefined temperature for low warning threshold in
Centigrades
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.22
Predefined temperature for high warning threshold in
Centigrades
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.23
Predefined temperature for high alarm threshold in
Centigrades
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.24
Internally measured supply voltage in transceiver in the
units of Volts. Bytes 98 & 99 of Address A2h
OctetString
Constraints:
range: 0-16
.1.3.6.1.4.1.629.204.1.3.1.1.25
Predefined voltage for low alarm threshold in the
units of Volts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.26
Predefined voltage for low warning threshold in the
units of Volts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.27
Predefined voltage for high warning threshold in the
units of Volts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.28
Predefined voltage for high alarm threshold in the
units of Volts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.29
Internally measured TX Bias Current in the units of mA.
Bytes 100 & 101 of Address A2h
OctetString
Constraints:
range: 0-16
.1.3.6.1.4.1.629.204.1.3.1.1.30
Predefined bias current for low alarm threshold in the
units of mA
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.31
Predefined bias current for low warning threshold in
the units of mA
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.32
Predefined bias current for high warning threshold in the
units of mA
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.33
Predefined bias current for high alarm threshold in the
units of mA
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.34
Measured TX output power in the units of dBm.
OctetString
Constraints:
range: 0-16
.1.3.6.1.4.1.629.204.1.3.1.1.35
Predefined Tx output power for low alarm threshold in the
units of dBm.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.36
Predefined Tx output power for low warning threshold in the
units of dBm.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.37
Predefined Tx output power for high warning threshold in the
units of dBm.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.38
Predefined Tx output power for high alarm threshold in
the units of dBm.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.39
Measured received optical power.
Received power, RX_PWR, is given in uW by the
following equation:
Rx_PWR (uW) = Rx_PWR(4) * Rx_PWR AD
4 (16 bit unsigned integer) +
Rx_PWR(3) * Rx_PWR AD
3 (16 bit unsigned integer) +
Rx…
OctetString
Constraints:
range: 0-16
.1.3.6.1.4.1.629.204.1.3.1.1.40
Predefined Rx input power for low alarm threshold in
the units of dBm.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.41
Predefined Rx input power for low warning threshold in
the units of dBm.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.42
Predefined Rx input power for high warning threshold in the
units of dBm.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.43
Predefined Rx input power for high alarm threshold in
the units of dBm.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.44
Indicates transceiver has achieved power up and data is ready.
Bit remains high until data is ready to be read at which time
the device sets the bit low. Byte 110, bit 0 of A2h
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.45
Digital state of the RX_LOS Output Pin. Updated within 100ms
of change on pin. Byte 110, bit 1 of A2h
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.46
Digital state of the TX Fault Output Pin. Updated within
100ms of change on pin. Byte 110, bit 2 of A2h
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.47
Read/write bit that allows software rate select control.
Writing 1 selects full bandwidth operation. This bit is
OR'd with the hard Rate_Select, AS(0) or RS(0) pin value.
See Table 3.11 for timing requirements. Default …
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.48
Digital state of the SFP Rate_Select Input Pin. Updated within
100ms of change on pin. Note: This pin is also known as AS(0)
in SFF-8079 and RS(0) in SFF-8431. Byte 110, bit 4 of A2h
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.49
Reserved for digital state of input pin AS(1) per SFF-8079 and
RS(1) per SFF-8431. Updated within 100ms of change on pin. See
A2h Byte 118, Bit 3 for Soft RS(1) Select control information.
Byte 110, bit 5 of A2h
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.50
Read/write bit that allows software disable of laser.
Writing 1 disables laser. See Table 3.11 for enable/
disable timing requirements. This bit is OR d with the hard
TX_DISABLE pin value. Note, per SFP MSA TX_DISABLE p…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.51
Digital state of the TX Disable Input Pin. Updated within
100ms of change on pin.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.52
Fixed decimal (unsigned) calibration data, laser bias
current measured in mA.
OctetString
Constraints:
range: 0-16
.1.3.6.1.4.1.629.204.1.3.1.1.53
Fixed decimal (signed two's complement) calibration data,
laser bias current measured in mA.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.54
Fixed decimal (unsigned) calibration data, transmitter
coupled output power in the units of dBm.
OctetString
Constraints:
range: 0-16
.1.3.6.1.4.1.629.204.1.3.1.1.55
Fixed decimal (signed two's complement) calibration data,
transmitter coupled output power in the units of dBm.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.56
Fixed decimal (unsigned) calibration data, internal module
temperature in C
OctetString
Constraints:
range: 0-16
.1.3.6.1.4.1.629.204.1.3.1.1.57
Fixed decimal (signed two's complement) calibration data,
internal module temperature in C
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.58
Fixed decimal (unsigned) calibration data, internal module
supply voltage in Volts.
OctetString
Constraints:
range: 0-16
.1.3.6.1.4.1.629.204.1.3.1.1.59
Fixed decimal (signed two's complement) calibration data,
internal module supply voltage in Volts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.204.1.3.1.1.60
Reserved for SFF-8431 Power Level (maximum power dissipation)
enable.
Value of zero disables Power Level 2 (1.0 Watt max).
Value of one enables Power Level 2 (1.5 Watt max).
Refer to Table 3.7 for Power Level declaratio…
Enumeration
Enumerated Values:
1off
2on
.1.3.6.1.4.1.629.204.1.3.1.1.61
Reserved for SFF-8431 Power Level (maximum power dissipation)
status.Value of zero indicates Power Level 1 operation
(1.0 Watt max) Value of one indicates Power Level 2 operation
(1.5 Watt max).Refer to Table 3.7 for Po…
Enumeration
Enumerated Values:
1off
2on
.1.3.6.1.4.1.629.204.1.3.1.1.62
Read/write bit that allows software Tx rate control. Writing
1 selects full speed Tx operation. This bit is OR d with the
hard RS(1) pin value.See Table 3.11 for timing requirements.
Default at power up is logic zero/lo…
Enumeration
Enumerated Values:
1off
2on
.1.3.6.1.4.1.629.204.1.3.1.1.63
.1.3.6.1.4.1.629.204.1.4.2 · 1 row entry · 2 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsSffMsxTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-SFF-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-SFF-MIB::nbsSffMsxTable'
Non-standardized extensions to the Multi-Source Agreement
nbsSffMsxEntry row .1.3.6.1.4.1.629.204.1.4.2.1
Pluggable Transceiver information and settings yet to be
standardized
Column Syntax OID
MIB2 ifIndex of this port
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.629.204.1.4.2.1.1
Some Gigabit Ethernet compatible SFP transeivers, such as
SFP-FDSGMII-M and SFP-FDSGMII-LR, have a built-in SGMII PHY.
Those that do require special autonegotiation processing,
without which autonegotiation will fail an…
Enumerationr/w
Enumerated Values:
1notSupported
2no
3yes
.1.3.6.1.4.1.629.204.1.4.2.1.2