tnOamPingCtlTimeOut

TN-OAM-TEST-MIB · .1.3.6.1.4.1.7483.6.1.2.11.1.4.1.19

Object

column r/w milliseconds Unsigned32
The value of tnOamPingCtlTimeOut specifies the time-out value,
in milliseconds, to be used during a test run.
              
Timers (with duration configured using the tnOamPingCtlTimeOut value)
are used in one of two ways during a test run.
1.  Per Probe:  a timer is started each time a probe is sent.  If the
    timer expires before the probe response arrives, the probe is
    declared failed.  This is the traditional time-out method for a
    sequence of probes.
    OR
2.  Per Test:  a timer is started once per test run, when the last
    probe of the test run is sent.  ANY probe which does not have a
    response when the timer expires is declared failed.
              
'Per Probe' or 'Per Test' is chosen based on the
tnOamPingCtlTestMode value.  The choice is not configurable.
              
The accepted minimum, maximum, and default values for
tnOamPingCtlTimeOut depend on tnOamPingCtlTestMode, as shown in the
following table in seconds.  The table also shows the timer usage
for the test mode.
              
tnOamPingCtlTestMode      Min     Max      Def     Timer Usage
----------------------    ---     ---      ---     -----------
'atmPing'                 1       10       5       Per Probe
'dnsPing'                 1       120      5       Per Probe
'ethCfmLoopback'          1       10       5       Per Probe
'ethCfmTwoWayDelay'       1       10       5       Per Test
'ethCfmOneWayDelay'       1       10       5       Per Test
'ethCfmTwoWaySlm'         1       10       5       Per Test
'ethCfmTwoWayLm'          1000    10000    1000    Per Test
'icmpPing'                1       10       5       Per Test
'lspPing'                 1       10       5       Per Probe
'macPing'                 1       10       5       Per Probe
'mfibPing'                1       100      5       Per Probe
'mtuPing'                 1       10       5       Per Probe
'p2mpLspPing'             1       120      10      Per Probe
'sdpPing'                 1       10       5       Per Probe
'vccvPing'                1       10       5       Per Probe
'vprnPing'                1       100      5       Per Probe
otherwise  .........  the value of tnOamPingCtlTimeOut is irrelevant

Context

MIB
TN-OAM-TEST-MIB
OID
.1.3.6.1.4.1.7483.6.1.2.11.1.4.1.19
Type
column
Access
readwrite
Status
current
Units
milliseconds
Parent
tnOamPingCtlEntry
Table
tnOamPingCtlTable
Siblings
37

Syntax

milliseconds Unsigned32

Values & Constraints

Object Constraints
range: 1-120000

Related Objects

Sibling Objects