tnOamPingCtlInterval

TN-OAM-TEST-MIB · .1.3.6.1.4.1.7483.6.1.2.11.1.4.1.21

Object

column r/w milliseconds Unsigned32
The value of tnOamPingCtlInterval specifies the time to wait between
the transmission of one OAM Echo request and the next.
              
The applicability, range, and default value of the interval specified
using the tnOamPingCtlInterval vary with tnOamPingCtlTestMode and
tnOamIcmpPingCtlRapid, as shown in the following table in seconds.
              
tnOamPingCtlTestMode   Supported Values (sec)           Default (sec)
'ethCfmLoopback'         1, 2, .. 10                           5
'ethCfmTwoWayDelay'      0.1, 0.2, .. 0.9;  1, 2, .. 10        5
'ethCfmOneWayDelay'      0.1, 0.2, .. 0.9;  1, 2, .. 10        5
'ethCfmTwoWaySlm'        0.1, 0.2, .. 0.9;  1, 2, .. 10        5
'ethCfmTwoWayLm'         0.1, 1, 10                            1
'icmpPing' with RAPID    0.01, 0.02, .. 100.00                 0.01
'icmpPing' without RAPID 1, 2, .. 10000                        1
'p2mpLspPing'            not applicable
otherwise                1, 2, .. 10                           1
              
Following are the allowed value for 1830 TPS:
{33, 100, 1000} - all values in decimilliseconds
{1, 10, 60, 600} - all values in seconds.

Context

MIB
TN-OAM-TEST-MIB
OID
.1.3.6.1.4.1.7483.6.1.2.11.1.4.1.21
Type
column
Access
readwrite
Status
current
Units
milliseconds
Parent
tnOamPingCtlEntry
Table
tnOamPingCtlTable
Siblings
37

Syntax

milliseconds Unsigned32

Values & Constraints

Object Constraints
range: 1-90000

Related Objects

Sibling Objects