tnDot1agCfmMepSlmTWTimeout
TN-IEEE8021-CFM-MIB ·
.1.3.6.1.4.1.7483.6.1.2.52.7.5.1.6
Object
column
r/w
seconds Unsigned32
The value of tnDot1agCfmMepSlmTWTimeout specifies the time-out value, in seconds, to wait for a Synthetic Loss Measurement (SLM) message to reply for the two-way SLM test. Upon expiration of the timeout period, the agent assumes that the message response will not be received. Any response received after the timeout period has expired is silently discarded.
Context
- MIB
- TN-IEEE8021-CFM-MIB
- OID
.1.3.6.1.4.1.7483.6.1.2.52.7.5.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- tnDot1agCfmMepSlmTWTestEntry
- Table
- tnDot1agCfmMepSlmTWTestTable
- Siblings
- 9
Syntax
seconds Unsigned32
Values & Constraints
Object Constraints
range: 1-10
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tnDot1agCfmMepSlmTWTestStatus The value of tnDot1agCfmMepSlmTWTestStatus specifies the operational
state of the two-way Synthetic Loss Measurement (SLM) test.
To issue a two-way SLM test the use… | column | TN-TC-MIBTmnxEnabledDisabled | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.1 |
| tnDot1agCfmMepSlmTWIntrvlUnits The value of tnDot1agCfmMepSlmTWIntrvlUnits, in conjuction with
tnDot1agCfmMepSlmTWInterval, specifies the interval between Synthetic
Loss Measurement (SLM) messages sent by the t… | column | Enumeration | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.10 |
| tnDot1agCfmMepSlmTWTestId The value of tnDot1agCfmMepSlmTWTestId indicates the test identifier
used to initiate the two-way Synthetic Loss Measurement (SLM) test. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.2 |
| tnDot1agCfmMepSlmTWMacAddress The value of tnDot1agCfmMepSlmTWMacAddress specifies the MAC address
used as a target for the two-way Synthetic Loss Measurement (SLM) test.
This object MUST be set… | column | SNMPv2-TCMacAddress | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.3 |
| tnDot1agCfmMepSlmTWPriority The value of tnDot1agCfmMepSlmTWPriority specifies the priority used
in the generated test frame for the two-way Synthetic Loss Measurement
(SLM) test. | column | Unsigned32 | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.4 |
| tnDot1agCfmMepSlmTWInterval The value of tnDot1agCfmMepSlmTWInterval specifies the delay, in
seconds, between Synthetic Loss Measurement (SLM) messages for the
two-way SLM test.
Following ar… | column | seconds Unsigned32 | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.5 |
| tnDot1agCfmMepSlmTWDataSize The value of tnDot1agCfmMepSlmTWDataSize specifies the data size,
in bytes, contained in the padding TLV for the two-way Synthetic Loss
Measurement (SLM) test. A value of zero (0)… | column | bytes Unsigned32 | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.7 |
| tnDot1agCfmMepSlmTWSendCount The value of tnDot1agCfmMepSlmTWSendCount specifies the number of
Synthetic Loss Measurement (SLM) packets to send during the two-way
SLM test. | column | packets Unsigned32 | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.8 |
| tnDot1agCfmMepSlmTWIntervalRedef The value of tnDot1agCfmMepSlmTWIntervalRedef specifies the interval
of SLM frames transmitted.
The permitted values are 100ms(0),1s (1),10s(2),1m(3),10(4). | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.9 |