tnDot1agCfmMepSlmTWIntrvlUnits
TN-IEEE8021-CFM-MIB ·
.1.3.6.1.4.1.7483.6.1.2.52.7.5.1.10
Object
column
r/w
Enumeration
The value of tnDot1agCfmMepSlmTWIntrvlUnits, in conjuction with
tnDot1agCfmMepSlmTWInterval, specifies the interval between Synthetic
Loss Measurement (SLM) messages sent by the two-way SLM test. For
example, if tnDot1agCfmMepSlmTWInterval has the value 90, and
tnDot1agCfmMepSlmTWIntrvlUnits has the value 'centiseconds(2)', the
interval between SLM messages is 0.9 seconds.
For example, if tnDot1agCfmMepSlmTWInterval has the value 33, and
tnDot1agCfmMepSlmTWIntrvlUnits has the value 'decimilliseconds (3)',
the interval between SLM messages is 3.3 milliseconds.
The intervals supported are shown in the tnDot1agCfmMepSlmTWInterval
DESCRIPTION clause.
Context
- MIB
- TN-IEEE8021-CFM-MIB
- OID
.1.3.6.1.4.1.7483.6.1.2.52.7.5.1.10- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tnDot1agCfmMepSlmTWTestEntry
- Table
- tnDot1agCfmMepSlmTWTestTable
- Siblings
- 9
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | seconds |
2 | centiseconds |
3 | decimilliseconds |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tnDot1agCfmMepSlmTWTestStatus The value of tnDot1agCfmMepSlmTWTestStatus specifies the operational
state of the two-way Synthetic Loss Measurement (SLM) test.
To issue a two-way SLM test the use… | column | TN-TC-MIBTmnxEnabledDisabled | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.1 |
| tnDot1agCfmMepSlmTWTestId The value of tnDot1agCfmMepSlmTWTestId indicates the test identifier
used to initiate the two-way Synthetic Loss Measurement (SLM) test. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.2 |
| tnDot1agCfmMepSlmTWMacAddress The value of tnDot1agCfmMepSlmTWMacAddress specifies the MAC address
used as a target for the two-way Synthetic Loss Measurement (SLM) test.
This object MUST be set… | column | SNMPv2-TCMacAddress | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.3 |
| tnDot1agCfmMepSlmTWPriority The value of tnDot1agCfmMepSlmTWPriority specifies the priority used
in the generated test frame for the two-way Synthetic Loss Measurement
(SLM) test. | column | Unsigned32 | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.4 |
| tnDot1agCfmMepSlmTWInterval The value of tnDot1agCfmMepSlmTWInterval specifies the delay, in
seconds, between Synthetic Loss Measurement (SLM) messages for the
two-way SLM test.
Following ar… | column | seconds Unsigned32 | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.5 |
| tnDot1agCfmMepSlmTWTimeout The value of tnDot1agCfmMepSlmTWTimeout specifies the time-out value,
in seconds, to wait for a Synthetic Loss Measurement (SLM) message to
reply for the two-way SLM test. Upon ex… | column | seconds Unsigned32 | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.6 |
| tnDot1agCfmMepSlmTWDataSize The value of tnDot1agCfmMepSlmTWDataSize specifies the data size,
in bytes, contained in the padding TLV for the two-way Synthetic Loss
Measurement (SLM) test. A value of zero (0)… | column | bytes Unsigned32 | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.7 |
| tnDot1agCfmMepSlmTWSendCount The value of tnDot1agCfmMepSlmTWSendCount specifies the number of
Synthetic Loss Measurement (SLM) packets to send during the two-way
SLM test. | column | packets Unsigned32 | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.8 |
| tnDot1agCfmMepSlmTWIntervalRedef The value of tnDot1agCfmMepSlmTWIntervalRedef specifies the interval
of SLM frames transmitted.
The permitted values are 100ms(0),1s (1),10s(2),1m(3),10(4). | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.7483.6.1.2.52.7.5.1.9 |